首页 | 官方网站   微博 | 高级检索  
     


MOS hydrogen sensor with very fast response based on ultra-thin thermal SiO2 film
Authors:Chi Lu  Zhi Chen
Affiliation:1. Department of Electrical and Computer Engineering and Center for Nanoscale Science and Engineering, University of Kentucky, Lexington, KY 40506, USA;2. National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
Abstract:An MOS capacitor-type hydrogen gas sensor was fabricated with the structure of Ni/SiO2/Si by using conventional silicon wafer technologies. Grown by dry oxidation at 900°C, the thickness of the SiO2 film was only 24 Å. At 150°C, comparing to another MOS capacitor with 148 Å-thick oxide and otherwise identical configurations, this sensor showed much faster response speed (the time interval to reach half of the magnitude of the steady-state signal, or t50%, was only 4 s in response to 1% H2 without deduction of the delay from the gas delivery system), as well as enhanced signal magnitude (about two times of the former for 1% H2). Based on the hydrogen-binding to the traps in the bulk SiO2, a mechanism was proposed to explain the very short response time on the device with the ultra-thin SiO2. The gate leakage in the device is also discussed. The presented sensor demonstrates a promising step in designing low-cost H2 detectors with very fast responses.
Keywords:MOS capacitor   H2 sensor   Ultra-thin thermal SiO2 film   Response time   SiO2 bulk trap