彩色多普勒超声心动图在先天性心脏病封堵术中的应用研究
引用本文:何小梅,张源祥,樊文峰,张立建.彩色多普勒超声心动图在先天性心脏病封堵术中的应用研究[J].临床荟萃,2006,21(11):778-780.
作者姓名:何小梅  张源祥  樊文峰  张立建
作者单位:河北医科大学第一医院,超声科,河北,石家庄,050031
基金项目:本项目为2005年河北省政府十项民心工程之一,是与省妇联和省儿基会共同开展救助贫困儿童先心病的爱心工程.
摘    要:目的 评价彩色多普勒超声心动图在先天性心脏病封堵术的应用价值.方法 510例先天性心脏病,均采用Amplatzer封堵器封堵.术前、术中及术后第2天、3个月及半年复查超声心动图,观察房、室及动脉水平有无分流,各瓣膜的活动,上、下腔静脉和肺静脉、冠状静脉窦、左肺动脉及主动脉弓血流是否通畅,心脏大小及肺动脉内径的变化.结果 510例成功封堵,其中279例室间隔缺损,111例房间隔缺损,120例动脉导管未闭.封堵术后观察分流已消失,封堵器均位置正常,固定良好,左肺动脉及主动脉弓降部无明显狭窄.上、下腔静脉及右肺上静脉血流通畅,对各瓣膜活动均无影响;半年后,均无残余分流,心腔内径及肺动脉内径接近正常.结论 彩色多普勒超声心动图在先天性心脏病封堵术后,检测有无残余分流,左肺动脉和主动脉弓降部血流是否受阻,是否影响各瓣膜活动及腔静脉回流是否通畅,从而验证封堵器的大小选择是否合适,起到重要的作用.

关 键 词:超声心动描记术  房间隔缺损  室间隔缺损  动脉导管未闭  封堵术
文章编号:1004-583X(2006)11-0778-03
收稿时间:2005-11-08
修稿时间:2005-11-082006-04-12

Color Doppler ultrasonographic assessment of transcatheter closure of congenital heart disease
HE Xiao-mei,ZHANG Yuan-xiang,FAN Wen-feng,ZHANG Li-jian.Color Doppler ultrasonographic assessment of transcatheter closure of congenital heart disease[J].Clinical Focus,2006,21(11):778-780.
Authors:HE Xiao-mei  ZHANG Yuan-xiang  FAN Wen-feng  ZHANG Li-jian
Affiliation:Department of Ultrasound ,the First Hospital of Hebei Medical University ,Shijiazhuang 050031 ,China
Abstract:Objective To report our experience in transcatheter closure of congenital heart disease using echocardiography.Methods Five hundred and ten patients underwent transcatheter closure using the Amplatzer occluder.Echocardiography was performed 2 days,3 months and half a year after operation in order to find whether there were shunts in ventricular septum,atrial septum and ductus arterious and in order to observe all valves movement and the blood flowing in superior vena cava(SVC),inferior vena cava(IVC),pulmonary veins(PV),coronary sinus(CS),aorta arch and left pulmonary arteries(LPA),and in order to meature the size of the atrial and ventricular chambers and the pulmonary arteries.Results Successful transcatherer closure was shown in all 510 cases of congenital heart disease,among which ventricular septal defect(VSD) was 279 cases,atrial septal defect(ASD) 111 cases,patent ductus arterious(PDA) 120 cases respectively.Shunts dispeared immediately after the operation.The size and position of occluders suited 510 cases.Aorta arch showed no and LPA was not stenosis.The blood flowing was unblocked in SVC,IVC,PV and CS,and all valves movement was not affected.Half a year after operation,the size of the atrial and ventricular chambers and pulmonary arteries returned to normal,the residual shunts were not detected in 510 cases.Conclusion Echocardiography is of great use in choosing patients,detecting whether there are residual shunts after operation and flow of aorta and LPA,and flow return of vein and valves move after transcatheter closure of 510 cases with congenital heart,proving the size of occluders selected.
Keywords:ecocardiograpghy  atrial septal defect  ventricular septal defect  patent ductus arteriosus  occlusion