首页 | 官方网站   微博 | 高级检索  
     


Internal-corrosion inhibitors for pipelines in heat-supply systems carrying water with a high oxygen content
Authors:Yu V Balaban-Irmenin  N G Fokina
Affiliation:(1) Moscow, Russia
Abstract:The reliability of heat-supply systems is determined primarily by internal corrosion of the pipelines. The concentration of oxygen in the water exerts a major influence on the corrosion. In systems with a standard oxygen content, OéDF-Zn is a highly effective corrosion inhibitor. However, there are systems in which the quality of deaeration of the make-up water of the heat-supply system is low (or deaeration is nonexistent), and the concentration of oxygen is considerably above the standard value. Classed among these systems, for example, are the HWS systems, which are incorporated into closed heat-supply systems. The oxygen concentration in these systems is analyzed to assess the situation. __________ Translated from élektricheskie Stantsii, No. 6, June 2007, pp. 35–39.
Keywords:heat-supply systems  internal corrosion  oxygen concentration  corrosion inhibitors  phosphate adsorption
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23