岩石中痕量铅的催化极谱测定—乙醇-碘化钾-钒(Ⅳ)-抗坏血酸-盐酸体系 |
| |
引用本文: | 俞德先. 岩石中痕量铅的催化极谱测定—乙醇-碘化钾-钒(Ⅳ)-抗坏血酸-盐酸体系[J]. 岩石矿物学杂志, 1984, 3(2): 165-168 |
| |
作者姓名: | 俞德先 |
| |
作者单位: | 冶金部中南冶金勘探地质研究所 |
| |
摘 要: | 本文根据前人的经验研究了乙醇—碘化钾—钒(Ⅳ)—抗坏血酸中铅的极谱催化波特性,乙醇的存在,使底液的背景电流大大降低,而ppb级铅仍有明晰的波形。铅的检出限达0.0005微克/毫升(2.5 ×10~(-9)M),催化电流与铅浓度在0~2微克/毫升较宽的范围内成直线关系。本文试验了各种
|
Determination of Lead at ppb Levers by a Catalytic Polarographic Method |
| |
Abstract: | In the presence of ethyl alcohol, there exists a sensitive polarographic ca-talytic wave of the complex formed by Pb-Kl- V (IV)-ascorbic acid. The waveis available for the determination of lead within the range of 1-2ug/ml. Thedetection limit of lead is 0.0005ug/ml, the wave peak appears at -0.30v in003M hydrochoric acid medium. |
| |
Keywords: | |
本文献已被 CNKI 等数据库收录! |
| 点击此处可从《岩石矿物学杂志》浏览原始摘要信息 |
|
点击此处可从《岩石矿物学杂志》下载全文 |
|