摘    要:总结了塘寨电厂超临界“w”火焰锅炉冷灰斗水冷壁泄漏情况,并对泄漏原因进行研究分析,为下一步研究制定解决措施提供依据,对超临界“w”火焰锅炉的安全运行具有重要的现实意义。

关 键 词:超临界“w”火焰锅炉  冷灰斗水冷壁  大面积泄漏  热疲劳

Analysis on the causes of water-cooled hopper bottom and water wall large area leakage in 600 MW supercritical W-flame boiler
Wu Zhi,Wang Tingqin. Analysis on the causes of water-cooled hopper bottom and water wall large area leakage in 600 MW supercritical W-flame boiler[J]. Guizhou Electric Power Technology, 2013, 0(11): 7-9,3
Authors:Wu Zhi  Wang Tingqin
Affiliation:(Guizhou Wujiangdu Hydropower Development Co. , Ltd,Guiyang 550002 Guizhou,China)
Abstract:This paper summarized the leakage situation of supercritical W boiler water-flame cooled hopper bottom and water wall in Tangzhai Power Plant, and studied and analyzed the cause of leakage, which provided the basis to formulate countermeasures for next research, and had important practical significance to safe operation of superefitieal W flame boiler.
Keywords:supercritical W flame boiler  water-cooled hopper bottom and water wall  large area leakage  thermal fatigue