首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   60篇
  免费   15篇
生物科学   75篇
  2023年   3篇
  2021年   11篇
  2020年   10篇
  2019年   3篇
  2018年   4篇
  2017年   10篇
  2016年   7篇
  2015年   2篇
  2014年   4篇
  2013年   5篇
  2012年   3篇
  2011年   2篇
  2010年   1篇
  2008年   2篇
  2007年   2篇
  2005年   3篇
  2002年   3篇
排序方式: 共有75条查询结果,搜索用时 15 毫秒
1.
Conversion factors used to estimate effective (E) and organ doses (HT) from air Kerma area product (KAP) are required to estimate population doses in percutaneous transhepatic biliary drainage (PTBD) and trans arterial chemoembolization (TACE) interventional procedures.In this study, E and HT for ten critical organs/tissues, were derived in 64 PTBD and 48 TACE procedures and in 14,540 irradiation events from dosimetric, technical and geometrical information included in the radiation dose structured report using the PCXMC Monte Carlo model, and the ICRP 103 organ weighting factors. Conversion factors of: 0.13; 0.19; 0.26 and 0.32 mSv Gy−1 cm−2 were established for irradiation events characterized by a Cu filtration of 0.0; 0.1; 0.4 and 0.9 mm, respectively. While a single coefficient of conversion is not able to provide estimates of E with enough accuracy, a high agreement is obtained between E estimated through Monte Carlo methods and E estimated through E/KAP conversion factors accounting separately for the different modes of fluoroscopy and the fluorography component of the procedures.An algorithm for the estimation of effective and organ doses from KAP has been established in biliary procedures which considers the Cu filtration in the X-ray irradiation events. A similar algorithm could be easily extended to other interventional procedures and incorporated in radiation dose monitoring systems to provide dosimetric estimates automatically with enough accuracy to assess population doses.  相似文献   
2.
Optimization of imaging examinations is a key requirement of both the International and European Basic Safety Standards, and the focus of much international activity. Although methodologies are well established in principle, there continues to be a variety of practical issues both in collecting and interpreting dose and image quality data and in making successful interventions to optimize exposures.A Coordinated Research Project, involving institutes from ten different countries, was established by the IAEA to assess the efficacy of recommended optimization methodologies in the field of paediatric radiology and to derive practical guidance on their implementation. The steps followed in this process were identification of the imaging process to be investigated (abdomen and chest x-rays, micturating cysto-urethrograms, and brain & thorax CT scans); collection of dose and image quality data; evaluation and comparison of the data between institutes and to standards; identification and implementation of interventions for optimization; and re-evaluation of dose and image quality parameters.The project succeeded both in achieving effective interventions for optimization of specific imaging tasks in individual institutes and in identifying key issues with potential to handicap this process. The main area in which problems were encountered was in the collation of reliable dose and image quality data. The reasons for this were explored and a series of recommendations have been made, summarized into ‘ten practical tips’ for optimization to assist institutes, particularly those in the early stages of addressing optimization issues.  相似文献   
3.
The effect of a dietary phosphorus regime in freshwater on vertebra bone mineralization was assessed in diploid and triploid Atlantic salmon, Salmo salar. Fish were fed either a low phosphorus (LP) diet containing 10.5 g kg−1 total phosphorus or a normal phosphorus (NP) diet containing 17.4 g kg−1 total phosphorus from ∼3 to ∼65 g (day 126) in body weight. Two further groups were fed the NP diet from ∼3 g in body weight, but were then switched to the LP diet after 38 (∼10 g in body weight) or 77 (∼30 g in body weight) days. Growth, vertebral ash content (% ash) and radiologically detectable vertebra pathologies were assessed. Triploids were initially smaller than diploids, and again on day 77, but there was no ploidy effect on days 38 or 126. Vertebral ash content increased with increasing body size and those fish fed the NP diet had higher vertebral ash content than those groups fed the LP diet during the intervening time period, but this diet effect became less apparent as fish grew, with all groups having relatively equal vertebral ash content at termination. In general, triploids had lower vertebral ash content than diploids on day 38 and this was most evident in the group fed the LP diet. On day 77, those triploids fed the LP diet during the intervening time period had lower vertebral ash content than diploids. At termination on day 126, the triploids had the same vertebral ash content as diploids, irrespective of diet. There was a ploidy × diet interaction on vertebral deformities, with triploids having higher prevalences of fish with ≥1 deformed vertebra in all dietary groups except continuous NP. In conclusion, between days 0 and 77 (3–30 g body size), triploids required more dietary phosphorus than diploids in order to maintain similar vertebral ash content. A possible link between phosphorus feeding history and phosphorus demand is also discussed.  相似文献   
4.
In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters.  相似文献   
5.
PurposeThe feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries.MethodsGafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka,r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2 Gy and 5 Gy. The uncertainties of alert levels in terms of DAP and Ka,r, and uncertainty of MSD were calculated.ResultsAbout 20–30% of all MSD values exceeded 2 Gy while only 2–6% exceeded 5 Gy. The correlations suggest that both DAP and Ka,r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly >0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2 Gy and 5 Gy (for 5 Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10–15% and of hospital-specific skin dose alert levels about 20–30% (with coverage factor k = 1).ConclusionsThe generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.  相似文献   
6.
目的:探讨介入治疗股骨头缺血坏死的临床应用价值。方法:采用Seldinger技术对28例患者行超选择股骨头供血动脉插管,动脉造影、溶通治疗。结果:28例患者治疗后髋部疼痛及关节功能障碍均有不同程度的减轻及改善,有效率96.4%;治疗后病变区血管分支增多、增粗;影像随访显示股骨头骨质不同程度修复。结论:介入治疗具有创伤小、并发症低、血管再通率高、临床症状改善明显的优势,能有效的改善股骨头的局部血液循环和髋关节的疼痛、活动功能,应大力推广。  相似文献   
7.
Conventional non-invasive imaging modalities of atherosclerosis such as coronary artery calcium (CAC) and carotid intimal medial thickness (C-IMT) provide information about the burden of disease. However, despite multiple validation studies of CAC, and C-IMT, these modalities do not accurately assess plaque characteristics, and the composition and inflammatory state of the plaque determine its stability and, therefore, the risk of clinical events. [(18)F]-2-fluoro-2-deoxy-D-glucose (FDG) imaging using positron-emission tomography (PET)/computed tomography (CT) has been extensively studied in oncologic metabolism. Studies using animal models and immunohistochemistry in humans show that FDG-PET/CT is exquisitely sensitive for detecting macrophage activity, an important source of cellular inflammation in vessel walls. More recently, we and others have shown that FDG-PET/CT enables highly precise, novel measurements of inflammatory activity of activity of atherosclerotic plaques in large and medium-sized arteries. FDG-PET/CT studies have many advantages over other imaging modalities: 1) high contrast resolution; 2) quantification of plaque volume and metabolic activity allowing for multi-modal atherosclerotic plaque quantification; 3) dynamic, real-time, in vivo imaging; 4) minimal operator dependence. Finally, vascular inflammation detected by FDG-PET/CT has been shown to predict cardiovascular (CV) events independent of traditional risk factors and is also highly associated with overall burden of atherosclerosis. Plaque activity by FDG-PET/CT is modulated by known beneficial CV interventions such as short term (12 week) statin therapy as well as longer term therapeutic lifestyle changes (16 months). The current methodology for quantification of FDG uptake in atherosclerotic plaque involves measurement of the standardized uptake value (SUV) of an artery of interest and of the venous blood pool in order to calculate a target to background ratio (TBR), which is calculated by dividing the arterial SUV by the venous blood pool SUV. This method has shown to represent a stable, reproducible phenotype over time, has a high sensitivity for detection of vascular inflammation, and also has high inter-and intra-reader reliability. Here we present our methodology for patient preparation, image acquisition, and quantification of atherosclerotic plaque activity and vascular inflammation using SUV, TBR, and a global parameter called the metabolic volumetric product (MVP). These approaches may be applied to assess vascular inflammation in various study samples of interest in a consistent fashion as we have shown in several prior publications.  相似文献   
8.
PurposeTo analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose.MethodsThe eye lens dose was estimated in terms of Hp(0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The Hp(0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (PKA) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions.ResultsThe annual eye lens doses estimated on goggles were 4.13 ± 0.93 and 4.98 ± 1.28 mSv. Over the aprons, the doses obtained were 10.83 ± 0.99 and 11.97 ± 1.44 mSv. The correlation between the goggles and the apron dose was R2 = 0.89, with a ratio of 0.38. The correlation with the patient dose was R2 = 0.40, with a ratio of 1.79 μSv Gy−1 cm−2. The dose per procedure obtained over the aprons was 102 ± 16 μSv, and on goggles 40 ± 9 μSv. The eye lens dose normalized to PKA was 2.21 ± 0.58 μSv Gy−1 cm−2.ConclusionsMeasurements of personal dose equivalent over the paediatric cardiologist’s apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used.  相似文献   
9.
目的:探讨介入手术远程演示教学系统的应用及效果。方法:采取多机组、多屏幕实况转播,将导管室的高清血管造影图像、术野图像、全景图像传输到会场。结果:学员对介入手术远程转播满意度为100%,其中最满意的是转播交互环节。本次共进行10台手术远程转播,无一例转播相关并发症发生,患者对治疗评价均及保护隐私情况非常满意。基本实现了导管室与会场的双向音视频互动,学员同术者在手术过程中的直接交流起到了较好的教学效果。结论:介入手术演示已经成为继续医学教育必不可少的手段,数字化介入手术转播是将来介入手术转播的发展方向。  相似文献   
10.
目的:探讨宝石能谱CT用于冠状动脉支架内成像质量评估的应用价值。方法:回顾分析56例冠状动脉支架植入后患者,按照支架厚度及直径分成四组。采用宝石能谱CT对冠状动脉成像及同时进行冠状动脉造影患者的影像学资料,通过分析宝石能谱CT的冠状动脉的成像质量,与冠状动脉造影进行对比,得出宝石能谱CT用于冠状动脉介入治疗术后支架内成像质量评估的价值。结果:宝石能谱CT显示支架内再狭窄的敏感度为100%,特异度为98.6%,阴性预测值为100%。直径≥3 mm的支架内成像质量优于直径3 mm的支架。但支架直径和厚度对宝石能谱CT支架内成像质量的可评估率没有差异。结论:宝石能谱CT均能提供优秀的冠状动脉支架内成像质量,采用宝石能谱CT替代冠状动脉造影术可对冠脉支架术后支架内影像进行评估。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号