1. To investigate Genkwa Flos hepatotoxicity, a cell metabolomics strategy combined with serum pharmacology was performed on human HL-7702 liver cells in this study.
2. Firstly, cell viability and biochemical indicators were determined and the cell morphology was observed to confirm the cell injury and develop a cell hepatotoxicity model. Then, with the help of cell metabolomics based on UPLC-MS, the Genkwa Flos group samples were completely separated from the blank group samples in the score plots and seven upregulated as well as two down-regulated putative biomarkers in the loading plot were identified and confirmed. Besides, two signal molecules and four enzymes involved in biosynthesis pathway of lysophosphatidylcholine and the sphingosine kinase/sphingosine-1-phosphate pathway were determined to investigate the relationship between Genkwa Flos hepatotoxicity and these two classic pathways. Finally, the metabolic pathways related to specific biomarkers and two classic metabolic pathways were analyzed to explain the possible mechanism of Genkwa Flos hepatotoxicity.
3. Based on the results, lipid peroxidation and oxidative stress, phospholipase A2/lysophosphatidylcholine pathway, the disturbance of sphingosine-1-phosphate metabolic profile centered on sphingosine kinase/sphingosine-1-phosphate pathway and fatty acid metabolism might be critical participators in the progression of liver injury induced by Genkwa Flos. 相似文献
Summary During pacemaker implantation in a patient with permanent atrial fibrillation, it remained impossible to advance a passive
fixation lead with fins through the right atrium. However, a lead with a retractable screw easily passed the right atrium
and was positioned in the right ventricle. Transesophageal echocardiography revealed an extensive net–like perforated Eustachian
valve within the right atrium that had caused entrapment of the anchor fins during lead implantation. Remnants of embryonal
structures within the right atrium should be considered a rare possible barrier during pacemaker implantation. 相似文献
The Department of Health has funded a national diabetes network to support clinical research. The network will facilitate recruitment into clinical trials and has been widely welcomed by clinicians. However, if the network is to reach its full potential, all those involved will need to advocate a change in attitude towards clinical trials and research, encouraging participation and contribution of data. Clinicians need to be willing to take a proactive view about research studies, and to encourage patients to adopt a positive and altruistic attitude towards trial participation. The future of trials and other important clinical research in the UK may depend on it. 相似文献
Background The skin microdiallysis technique makes it possible to measure histamine release in intact human skin in vivo directly. In this study we have used the microdialysis technique to characterize histamine release by codeine after intracutaneous injectioin and following skin challenge by a novel atraumatic delivery technique. Objective The purpose of the study was to compare histamine release in human skin by codeine. delivered by an intraprobe drug delivery system (IPD) and intracutaneous injections (ICT), with respect to dose-response relations, kinetics of histamine appearance and decay, corelations between histamine release and skin respones, and reproducibility. Methods Hollow dialysis fibres were inserted intradermally in 12 healthy subjects. Twelve fibres were inserted in each subjects, six fibres in each arm. Each fibre was perfused at a rate of 3 μL/min, and samples were collected in 2 min fractions. By the IPD technique, codeine was administrered to the skin by adding codeine to the perfusion medium. Sequential IPD challenges were performed in one arm. and ICTs were done on the other arm. Results Sixfold serial dilutions of codeine (0.01-3 mg/mL) caused a significant doserelated histamine release by ICT and IPD. Peak histamine release was found within the first 4 min after skin challenge by ICT and IPD, followed by a fast decline with a dialysate histamine half life of approximately 2-3 min. Peak hisamine release was linearly correlates with cumulative release of the 20 min sampling period, and histamine release correlated with weal soze. The coefficient of variation on peak histamine releae was 18.9% and 4.8% for codeine ICT and IPD, respectively. Conclusioin We have described in detail codeine-induced histamine release in intact human skin in vivo by the microdialysis technique. It was possible to administer codeine atraumaticallyl to the skin by intraprobe delivery. The skin microdialysis codeine atraumaticallly to the skin by intraprobe delivery. The skin microdialysis technique opens up possibilities for measurement of infllammatory mediators release in normal and diseases skin, and it will be possible to deliver immunopharmacologically active drugsto the skin by intraprobe delivery. 相似文献
The known effects of drugs from a variety of pharmacologic/therapeutic classes on the respiratory system and worldwide regulatory requirements support the need for conducting respiratory evaluations in safety pharmacology. The objective of these studies is to evaluate the potential for drugs to cause secondary pharmacologic or toxicologic effects that influence respiratory function. Changes in respiratory function can result either from alterations in the pumping apparatus that controls the pattern of pulmonary ventilation or from changes in the mechanical properties of the lung that determine the transpulmonary pressures (work) required for lung inflation and deflation. Defects in the pumping apparatus are classified as hypo- or hyperventilation syndromes and are evaluated by examining ventilatory parameters in a conscious animal model. The ventilatory parameters include respiratory rate, tidal volume, minute volume, peak (or mean) inspiratory flow, peak (or mean) expiratory flow, and fractional inspiratory time. Defects in mechanical properties of the lung are classified as obstructive or restrictive disorders and can be evaluated in animal models by performing flow-volume and pressure-volume maneuvers, respectively. The parameters used to detect airway obstruction include peak expiratory flow, forced expiratory flow at 25 and 75% of forced vital capacity, and a timed forced expiratory volume, while the parameters used to detect lung restriction include total lung capacity, inspiratory capacity, functional residual capacity, and compliance. Measurement of dynamic lung resistance and compliance, obtained continuously during tidal breathing, is an alternative method for evaluating obstructive and restrictive disorders, respectively, and is used when the response to drug treatment is expected to be immediate (within minutes post-dose). The species used in the safety pharmacology studies conducted in our laboratory are the same as those used in toxicology studies since pharmacokinetic and toxicologic/pathologic data are available in these species. These data can be used to help select test measurement intervals and doses and to aid in the interpretation of functional change. The techniques and procedures for measuring respiratory function parameters are well established in guinea pigs, rats, and dogs. 相似文献
Omeprazole is a substituted benzimidazole that causes dose-dependent intracellular inhibition of gastric acid secretion in humans. This double-blind study examined the effect of omeprazole in decreasing gastric acidity and gastric residual volume in outpatient adults. Unpremedicated outpatients, ASA I-III, 18 years or older (n = 17), were randomly assigned to receive omeprazole 80 mg, or placebo by mouth the night before scheduled elective outpatient surgery. The patients were fasted for 8 h prior to surgery. After the patient was anesthetized, an orogastric tube was inserted with proper placement verified by auscultation for gastric sounds. Gastric residual contents were withdrawn into a Luken's trap, and pH was then determined and gastric volume indexed to weight (ml.kg-1). Data were analyzed by a t-test, with P less than 0.05 considered statistically significant. Patient characteristics of both groups were similar. There was a statistically significant difference between the two groups for pH (P = 0.02), but not between the two groups for gastric volume indexed to weight (P = 0.07). 相似文献