首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   11篇
政治法律   50篇
  2024年   1篇
  2021年   1篇
  2020年   5篇
  2019年   1篇
  2018年   2篇
  2017年   3篇
  2016年   4篇
  2015年   4篇
  2014年   3篇
  2013年   1篇
  2012年   5篇
  2011年   3篇
  2010年   4篇
  2009年   4篇
  2008年   2篇
  2007年   4篇
  2006年   2篇
  2004年   1篇
排序方式: 共有50条查询结果,搜索用时 15 毫秒
1.
The elemental composition and postfiring residues of several "lead-free" or "nontoxic" centerfire handgun ammunition types currently available to the general public were examined. Offerings from Winchester, Remington/UMC, Federal and Speer were obtained from retail sources in both .45 ACP and 9 mm when possible. A total of 112 postfiring residue samples (SEM pins) were collected at varying distances from the muzzle, at two distances from target and from the shooter's hands. An additional 20 samples were collected by direct ignition of primers. Qualitative determinations were carried out using scanning electron microscopy (SEM)/electron dispersive spectrometry (EDS) analysis. All types tested contained aluminum (Al), silicon (Si), copper (Cu), and zinc (Zn). Most contain traces of sulfur and calcium. Winchester WinClean and Remington LeadLess contained potassium as the principle ingredient. Federal BallistClean contained barium, while Speer Lawman CleanFire contained strontium. In the main, these compared favorably with manufacturers' MSDS publications and patents granted. The characterizations undertaken here will be of use to the forensic electron microscopist as these formulations gain popularity.  相似文献   
2.
The estimation of bloodstain volume using fractal analysis of digital images of passive blood stains is presented. Binary digital photos of bloodstains of known volumes (ranging from 1 to 7 mL), dispersed in a defined area, were subjected to image analysis using FracLac V. 2.0 for ImageJ. The box-counting method was used to generate a fractal dimension for each trial. A positive correlation between the generated fractal number and the volume of blood was found (R(2) = 0.99). Regression equations were produced to estimate the volume of blood in blind trials. An error rate ranging from 78% for 1 mL to 7% for 6 mL demonstrated that as the volume increases so does the accuracy of the volume estimation. This method used in the preliminary study proved that bloodstain patterns may be deconstructed into mathematical parameters, thus removing the subjective element inherent in other methods of volume estimation.  相似文献   
3.
Car key burglary has recently become the focus of empirical investigation as offenders, no longer able to steal vehicles without first obtaining their keys, resort to "burgling" target properties. Research surrounding the modus operandi of these offenses is beginning to emerge; however, little attention has been paid to investigating the characteristics of car key burglary offenders. Challenging the assumption that car key burglary offenses are perpetrated by regular burglars, this study aims to differentiate between offenders. Logistic regression analysis of 110 car key and 110 regular burglary offenders revealed that car key burglars are more likely to have previous vehicle theft convictions and are also more likely to be detected on information supplied to the police than regular burglars. Regular burglars are more likely to have previous shoplifting convictions. It was concluded that car key burglars are a distinct sample of offenders and the implications of these findings are discussed.  相似文献   
4.
Bismuth oxychloride (BiOCl) was the first viable synthetic pearl pigment developed 50 years ago. It was only used for a limited time period in automotive paint (model years 1998–2000), serving to produce luster for a single Chrysler black metallic color. Identification of this pigment in an unknown automotive paint can thus facilitate determination of the vehicle of origin. Bismuth oxychloride imparts effects similar to those produced by silver/white mica pearlescent pigments, and such a pigment was used together with bismuth oxychloride in at least one original equipment manufacturer (OEM) basecoat. Silver/white micas are now used primarily in white pearl tricoat systems. This article describes the identification of bismuth oxychloride and silver/white mica pearlescent pigments in automotive finishes using FT‐IR spectroscopy, X‐ray fluorescence (XRF) spectrometry, and SEM/EDS analysis. Data for some cadmium pigments, which were used in automotive paint several decades ago, are also presented as they produce infrared absorptions similar to that of bismuth oxychloride.  相似文献   
5.
Chrome Yellow (PbCrO4·xPbSO4) was a common pigment in U.S. automobile OEM finishes for more than three decades, but in the early 1990s its use was discontinued. One of its main replacements was Bismuth Vanadate (BiVO4·nBi2MoO6, = 0–2), which was commercially introduced in 1985, as this inorganic pigment also produces a very bright hue and has excellent outdoor durability. This paper describes the in situ identification of Bismuth Vanadate in automotive finishes using FT‐IR and dispersive Raman spectroscopy and XRF spectrometry. Some differentiation of commercial formulations of this pigment is possible based on far‐infrared absorptions, Raman data, and elemental analysis. The spectral differences arise from the presence or absence of molybdenum, the use of two crystal polymorphs of BiVO4, and differences in pigment stabilizers. Bismuth Vanadate is usually not used alone, and it is typically found with Isoindoline Yellow, hydrous ferric oxide, rutile, Isoindolinone Yellow 3R, or various combinations of these.  相似文献   
6.
The occurrence of secondary DNA transfer has been previously established. However, the transfer of DNA through an intermediary has not been revisited with more sensitive current technologies implemented to increase the likelihood of obtaining results from low‐template/low‐quality samples. This study evaluated whether this increased sensitivity could lead to the detection of interpretable secondary DNA transfer profiles. After two minutes of hand to hand contact, participants immediately handled assigned knives. Swabbings of the knives with detectable amounts of DNA were amplified with the Identifiler® Plus Amplification Kit and injected on a 3130xl. DNA typing results indicated that secondary DNA transfer was detected in 85% of the samples. In five samples, the secondary contributor was either the only contributor or the major contributor identified despite never coming into direct contact with the knife. This study demonstrates the risk of assuming that DNA recovered from an object resulted from direct contact.  相似文献   
7.
现代科技对侦查的影响是全面而深刻的。对侦查的对象——刑事犯罪的影响体现为:在手段方面进行科技化改造,在领域方面促使其进一步增大;对侦查能力的影响体现为对侦查技术的进一步提升及对侦查理念的进一步拓展;对侦查法治的影响体现为侦查法治的文明化程度不断提升与现代科技为侦查法治带来了一些争议性问题;对侦查学的影响体现在侦查学和刑事技术学的融合和分化的发展过程。在现代科技的语境下,刑事侦查要辩证地对待现代科技的影响,促进侦查能力、侦查法治和侦查学的发展。  相似文献   
8.
Marc Bischoff received his PhD from the University of Lausanne, Institute of Police Science and Criminology, and later became the head of the Institute. His final examination paper for his doctorate degree constitutes a toolmark analysis and comparison between a suspected axe and questioned cuttings of wood trunks. Bischoff uses the scientific method to test the hypothesis he formulated. Dated 1916, this report includes his notes, measurements, photomicrographs of the questioned toolmarks and the test impressions, detailed sketches, technical discussion, results, and conclusions. Recognizing the historical value of Bischoff's work, it seemed important to get it translated. Photocopies of Bischoff's original work were obtained. The case report, translated from French, is presented here along with a brief history of the Firearm and Toolmark Identification field and Bischoff's role in the beginning of this field. Bischoff's work stands as testimony to the long tradition of the field of forensic toolmark analysis.  相似文献   
9.
Previous research has shown that as crime scene location deprivation increases (lower socioeconomic status), the recovery of forensic material, principally DNA and fingerprints, also increases. However, this increase does not result in more crimes being solved by forensic means. In this study, we analyze stolen vehicle data and find a statistically significant positive association between deprivation and the amount of forensic material that matched either the victim or an associate of the victim on a criminal database. The nature of this association was investigated further by inspecting recovered stolen vehicles to establish whether the condition of a stolen vehicle and the tidiness of its interior influenced the recovery of forensic material that was attributed to the victim or an associate. Contradictory results suggest that other factors may contribute to understanding the association between the recovery of victim- or associate-attributable forensic material and crime scene location deprivation.  相似文献   
10.
Abstract: The design and preliminary characterization of a novel sensor for drugs of abuse, DETECHIP®, is described in this proof‐of‐concept note. Combining both colorimetric and fluorimetric assays, DETECHIP® is suitable for lab and field use. More than a conventional spot test which provides a single “yes or no” answer, DETECHIP® provides twenty responses for a more complete characterization of suspect material. This is accomplished by visually noting colorimetric and fluorescent changes of carefully selected dyes upon the addition of test analytes, including drugs of abuse, with respect to controls. Color and fluorescence changes are recorded numerically so that a 20 digit identification code can be constructed for comparison of test analytes and known compounds. DETECHIP® is applicable to a variety of drugs, both plant‐derived and synthetic, addressing the need to use several different spot tests simultaneously for a single sample.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号