排序方式: 共有73条查询结果,搜索用时 2 毫秒
1.
Bowden L Faulkner R Clancy C Gallagher A Devine M Gorman D O'Reilly G Dowling A 《Radiation protection dosimetry》2011,147(1-2):210-214
Current guidelines quote tolerances for automatic exposure control (AEC) device performance for X-ray systems as 'Baseline ± X %'. However, in the situation where a baseline figure has not yet been achieved, as in the case of commissioning assessments, this tolerance is not relevant. The purpose of this work is to provide mean doses for direct digital radiography (DDR) X-ray system, operating in AEC, against which comparisons can be made. Dose measurements have been recorded under AEC operation on 29 DDR detectors from three different manufacturers. Two different testing protocols were examined: (1) water equivalent phantoms in front of the DDR detector and (2) aluminium block at the tube head. The average patient exit dose, using the aluminium block was 4.6 μGy with the antiscatter grid in place and 4.0 μGy with the grid removed. Using the water phantoms, the average dose was measured at 17.1 μGy with the antiscatter grid in place and 5.4 μGy with grid removed. Based on these results, it is clear that different testing configurations significantly impact on the measured dose. 相似文献
2.
Laura Gonzalez-Macia Malcolm R. Smyth Aoife Morrin Anthony J. Killard 《Electrochimica acta》2011,(11):562
The modification of silver paste electrodes with a combination of dodecylbenzenesulfonic acid and KCl has been shown to lead to significant enhancements of the electrochemical reduction of hydrogen peroxide. The catalytic enhancement was shown to be dependent on the concentration of the surfactant/salt solution, which resulted in increases of some 80-fold in amperometric response to hydrogen peroxide at −0.1 V vs Ag/AgCl, pH 6.8 over unmodified silver paste. Physical analysis showed modifications to both the surface morphology and chemical composition of the silver paste electrode surface. However, BET and electrochemical analysis revealed no significant change in surface area. It is suggested that the enhanced catalysis may result from the formation of stabilised surfactant/salt structures at the metal electrode surface. The electrode was also shown to be suitable for the amperometric detection of hydrogen peroxide with a limit of detection of 1.1 × 10−6 M (S/N = 3). 相似文献
3.
4.
Richard M. Gunner Rory P. Wilson Mark D. Holton Phil Hopkins Stephen H. Bell Nikki J. Marks Nigel C. Bennett Sam Ferreira Danny Govender Pauli Viljoen Angela Bruns O. Louis van Schalkwyk Mads F. Bertelsen Carlos M. Duarte Martin C. van Rooyen Craig J. Tambling Aoife Gppert Delmar Diesel D. Michael Scantlebury 《Journal of the Royal Society Interface》2022,19(186)
The combined use of global positioning system (GPS) technology and motion sensors within the discipline of movement ecology has increased over recent years. This is particularly the case for instrumented wildlife, with many studies now opting to record parameters at high (infra-second) sampling frequencies. However, the detail with which GPS loggers can elucidate fine-scale movement depends on the precision and accuracy of fixes, with accuracy being affected by signal reception. We hypothesized that animal behaviour was the main factor affecting fix inaccuracy, with inherent GPS positional noise (jitter) being most apparent during GPS fixes for non-moving locations, thereby producing disproportionate error during rest periods. A movement-verified filtering (MVF) protocol was constructed to compare GPS-derived speed data with dynamic body acceleration, to provide a computationally quick method for identifying genuine travelling movement. This method was tested on 11 free-ranging lions (Panthera leo) fitted with collar-mounted GPS units and tri-axial motion sensors recording at 1 and 40 Hz, respectively. The findings support the hypothesis and show that distance moved estimates were, on average, overestimated by greater than 80% prior to GPS screening. We present the conceptual and mathematical protocols for screening fix inaccuracy within high-resolution GPS datasets and demonstrate the importance that MVF has for avoiding inaccurate and biased estimates of movement. 相似文献
5.
6.
7.
Background concentrations of nitrogen dioxide (NO2) are not constant but vary temporally and spatially. The current paper presents a powerful tool for the quantification of the effects of wind direction and wind speed on background NO2 concentrations, particularly in cases where monitoring data are limited. In contrast to previous studies which applied similar methods to sites directly affected by local pollution sources, the current study focuses on background sites with the aim of improving methods for predicting background concentrations adopted in air quality modelling studies. The relationship between measured NO2 concentration in air at three such sites in Ireland and locally measured wind direction has been quantified using nonparametric regression methods. The major aim was to analyse a method for quantifying the effects of local wind direction on background levels of NO2 in Ireland. The method was expanded to include wind speed as an added predictor variable. A Gaussian kernel function is used in the analysis and circular statistics employed for the wind direction variable. Wind direction and wind speed were both found to have a statistically significant effect on background levels of NO2 at all three sites. Frequently environmental impact assessments are based on short term baseline monitoring producing a limited dataset. The presented non-parametric regression methods, in contrast to the frequently used methods such as binning of the data, allow concentrations for missing data pairs to be estimated and distinction between spurious and true peaks in concentrations to be made. The methods were found to provide a realistic estimation of long term concentration variation with wind direction and speed, even for cases where the data set is limited. Accurate identification of the actual variation at each location and causative factors could be made, thus supporting the improved definition of background concentrations for use in air quality modelling studies. 相似文献
8.
Laurent Georges Matthias Haase Aoife Houlihan Wiberg Torhildur Kristjansdottir Birgit Risholt 《Building Research & Information》2015,43(1):82-93
The net-zero emissions building (nZEB) performance is investigated for building operation (EO) and embodied emissions in materials (EE) for Norway's cold climate. nZEB concepts for new residential and office buildings are conceived in order to understand the balance and implications between operational and embodied emissions over the building's life. The main drivers for the CO2 equivalent (CO2e) emissions are revealed for both building concepts through a detailed emissions calculation. The influence of the CO2e factor for electricity is emphasized and it is shown to have significant impact on the temporal evolution of the overall CO2e emissions balance. The results show that the criterion for zero emissions in operation is easily reached for both nZEB concepts (independent of the CO2e factor considered). Embodied emissions are significant compared to operational emissions. It was found that an overall emissions balance including both operational and embodied energy is difficult to reach and would be unobtainable in a scenario of low carbon electricity from the grid. In this particular scenario, the net balance of emissions alone is nonetheless not a sufficient performance indicator for nZEB. 相似文献
9.
Kailong Liu Qiao Peng Remus Teodorescu Aoife M.Foley 《IEEE/CAA Journal of Automatica Sinica》2023,10(1):272-274
<正>Dear Editor, Lithium-ion(Li-ion) battery has become a promising source to supply and absorb energy/power for many energy-transportation applications. However, Li-ion battery capacity would inevitably degrade over time, making its related ageing prediction necessary. 相似文献
10.
O'Leary AM Whyte P Madden RH Cormican M Moore JE Mc Namara E Mc Gill K Kelly L Cowley D Moran L Scates P Collins JD Carroll CV 《Food microbiology》2011,28(3):426-433
Campylobacter enteritis is a zoonosis, an infectious disease transmissible under normal conditions from vertebrate animals to man, presenting a major global public health burden. In this study, Pulsed Field Gel Electrophoresis (PFGE) was employed to identify common genotypes in a collection of 600 Campylobacter isolates in order to investigate if profiles obtained from retail samples of foodstuffs matched genotypes causing illness in the community in Ireland. The Campylobacters were isolated from retail foodstuffs, and cases of gastroenteritis, over the same 20-month period in three population centres in Ireland. The major observation made was of a high level of PFGE-genotype heterogeneity; 236 SmaI discrete genotypes were found in 507 strains successfully analysed. Analysis of the PFGE profiles revealed 22 common profiles amongst food isolates and those causing enteritis in humans. These cojoint PFGE genotypes indicate that 56 (38%) of the human clinical isolates are genetically related to 129 (36%) of the food isolates. The identification of these recurrent PFGE types, in the sampled Campylobacter coli and Campylobacter jejuni populations, indicates that a high proportion of Campylobacter isolates found in foods of animal origin also occur in patients with symptoms of enteritis. This data adds weight to the epidemiological hypothesis that a high proportion of human Campylobacter cases are contracted via the handling and consumption of contaminated foodstuffs, in particular poultry. 相似文献