Introduction: Major Depressive Disorder (MDD) and General Anxiety Disorder (GAD) significantly contribute to the global burden of disease. Vilazodone, a combined serotonin reuptake inhibitor and 5-HT1A partial agonist, is an approved therapy for the treatment of MDD and which has been further investigated for GAD.
Areas covered: This article covers the pharmacokinetics and pharmacodynamics of vilazodone and provides an evaluation of the clinical usefulness of vilazodone for the treatment of MDD and anxiety disorders. A literature search was performed using PubMed/MEDLINE, Web of Science and the Cochrane Library.
Expert opinion: Studies have shown that vilazodone is significantly superior to placebo. However, vilazodone cannot as yet be recommended as a first-line treatment option for MDD as it is unclear whether the drug’s dual mechanism of action provides greater efficacy than prevailing treatment options. Moreover, more phase IV studies are needed to establish its efficacy and long-term safety in larger and more diverse populations. Although vilazodone may have an additional advantage for the treatment of anxiety symptoms in MDD, here also additional studies are required to confirm its efficacy over and above SSRI alternatives and other antidepressant treatments. Therefore, presently, vilazodone should be considered as a second- or third-line treatment option for MDD and GAD. 相似文献
BACKGROUND: Presently, complementary and alternative medicine, including both therapies and herbal/oral supplements, is used globally. Few studies have examined the use of specific therapies, separate from herbal/oral supplements, in cardiac rehabilitation. This paper presents a systematic evaluation of current research evidence related to use of specific complementary and alternative medicine therapies in secondary prevention of cardiovascular disease, with a view to making recommendations for cardiac rehabilitation. DESIGN AND METHODS: A literature search was conducted using complementary and alternative medicine websites, Medline, Allied and Complementary Medicine, CINAHL, Cochrane databases, EMBASE, SportDiscus, Clinical Evidence, and Evidence-Based Practice to locate research-based scientific evidence related to the use of complementary and alternative medicine in cardiac rehabilitation. Search keywords included heart, cardiac, cardiovascular, coronary, myocardial and rehabilitation, combined with particular therapies. Herbal/oral supplements were not included in this evaluation. RESULTS: Some complementary and alternative medicine therapies may be useful to patients by themselves or coupled with traditional cardiac rehabilitation. Tai chi, as a complement to existing exercise interventions, can be utilized for low and intermediate risk patients. transcendental meditation may be used as a stress reduction technique. There was insufficient evidence found for the use of acupuncture or chelation therapy in cardiac rehabilitation or secondary prevention. CONCLUSIONS: Some complementary and alternative medicine therapies hold promise for patients in cardiac rehabilitation. Further research is essential, however, in all areas of complementary and alternative medicine to confirm its usefulness as an adjunct to cardiac rehabilitation. 相似文献
The carpal regions of ten cadaver extremities were imaged by CT. The images were combined into a 3-dimensional model of the
carpus using a technique based on a dynamic programming algorithm to find an optimal estimate of the location of the bone
boundaries in the CT images. The resulting set of surface points on each bone was used to compute volumes and principal and
antipodal axes for the bones. A spatial coordinate system was established based on the positions of the centroids of three
bones in the distal carpal row. The angular orientations of all carpal bones were determined with respect to this system.
The principal axes for the same bone among ten wrist specimens proved to be more widely dispersed than the antipodal axes
for the same bones. The antipodal axes also correspond more closely to an intuitive notion of the “longest axis” of the bones.
We conclude that the antipodal axis is a more reliable and useful measure of bone orientation than the principal axis. 相似文献
The purpose of this study was to assess 7 methods of fixation for a midtarsal osteotomy. Polyurethane foam models (N = 6) and cadaver specimens (N = 4-7) were used to examine the force generated by the different constructs of fixation. A midtarsal osteotomy was performed on each specimen in the test groups. The osteotomies were fixated either with 2 parallel 0.062-in Kirschner wires and 40-mm-long, 4-mm partially threaded, cancellous, cannulated titanium screws, an external ring fixator (frame), a frame with wires tensioned (tension), a frame with wires tensioned and compressed toward the osteotomy (tension and compression), a frame with tension, compression, and parallel Kirschner wires, or a frame with tension, compression, and two 4.0 cannulated parallel screws, respectively. Each model was fixated, and the force generated by the construct across the osteotomy was recorded via the use of pressure-sensitive film. Statistical analysis of the data in the polyurethane foam group determined that the use of frame with tension, compression, and two 4.0 parallel cannulated screws was statistically superior to 1) frame, 2) frame with tension, 3) 2 parallel Kirschner wires, 4) two 4.0 cannulated parallel screws, and 5) frame with tension and compression. A cadaver study determined that the frame with tension, compression, and 2 parallel Kirschner wires was statistically superior to 1) frame and 2) two parallel Kirschner wires. These findings suggest that there is a difference in the force generated by the type of fixation construct across a midtarsal osteotomy. 相似文献
We have used 29Si solid-state nuclear magnetic resonance (NMR) spectroscopy to study the chemical structure of the silicone gels in virgin and explanted breast prostheses. Despite evidences of alteration in the morphological appearance of the silicone gel inside the breast prosthesis, our results do not reveal changes in the chemical nature and structure of the silicone gels after implantation. In addition to the main 29Si resonance peak at ?22.26 ppm that corresponds to the resonance frequency of the D repeat unit of the polysiloxane chains, the high sensitivity of our NMR technique allows the detection of very low concentrations of silicone compounds. Within our experimental detection limit of 0.2%, no signal between ?90 ppm and ?150 ppm are observed. This indicates that no silica products are present inside the gel of the prostheses. Furthermore, our 29Si NMR spectra indicate differences in the chemical compositions of the silicone gels from different manufacturers. 相似文献
The significance of life stress, coping, and social support was examined in relation to depressive symptomatology in a sample of 160 asymptomatic and mildly symptomatic HIV-antibody-positive (HIV+) men. The participants (mean age = 32 years) were interviewed about the life stress that they had experienced in the previous 6 相似文献
In this new colorimetric assay for Factor XIII in plasma, 5-(biotinamido)pentylamine is used as the amine substrate. Factor XIII, a zymogen, is transformed by thrombin and Ca2+ to active Factor XIIIa, and the incorporation of 5-(biotinamido)pentylamine into N,N-dimethylcasein is used to measure catalytically active Factor XIIIa. The biotinylated enzymatic product is immobilized onto 96-well microtiter plates, complexed with streptavidin-beta-galactosidase, and the absorbance at 405 nm is monitored for production of p-nitrophenol from p-nitrophenyl-beta-D-galactopyranoside. Concentrations of N,N-dimethylcasein, 5-(biotinamido)pentylamine, Ca2+, and thrombin were chosen to allow near-maximum velocity of amine incorporation. A linear relationship was obtained between assay product and plasma volume, from 0.5 to 50 microL of plasma. Results correlated well (r greater than 0.924) with those from the most frequently utilized radiometric filter-paper assay for Factor XIII. The method appears to be ideal for routine diagnostic estimation of Factor XIII in plasma because of its simplicity, its lack of use of radioisotopes, and its potential for assay of large numbers of samples by use of microtiter plates and automated plate readers. 相似文献