Amphotericin B (AMB) was often used in intra-articular injection administration for fungal arthritis, because it could often bring a satisfactory therapeutic efficacy and a minimum systemic toxic side effect. However, because of the multiple operations and the frequent injections, the compliance of the patients was bad. Therefore, to develop a long-term sustained-released preparation of AMB for mycotic arthritis intra-articular administration is of great significance. The purpose of present study was to develop a long-term sustained-released in situ gel of a water-insoluble drug AMB for mycotic arthritis intra-articular administration. Based on the evaluations of the in vitro properties of the formulations, the formulation containing 10% (w/w) ethanol, 15% (w/w) PG, 0.75% (w/w) HA, 5% (w/w) purified soybean oil, 0.03% (w/w) α-tocopherol, 15% (w/w) water and 55% (w/w) glyceryl monooleate was selected as a suitable intra-articular injectable in situ gel drug delivery system for water-insoluble drug AMB. Furthermore, the results of the in vivo study on rabbits showed that the selected formulation was a safe and effective long-term sustained-released intra-articular injectable AMB preparation. Therefore, the presented in situ AMB gel could reduce the frequency of the administration in the AMB treatment of fungal arthritis, and then would get a good patient compliance. 相似文献
We present a new scheme for visibly-opaque but near-infrared-transmitting filters involving 7 layers based on one-dimensional ternary photonic crystals, with capabilities in reaching nearly 100% transmission efficiency in the near-infrared region. Different decorative reflection colors can be created by adding additional three layers while maintaining the near-infrared transmission performance. In addition, our proposed structural colors show great angular insensitivity up to ±60° for both transverse electric and transverse magnetic polarizations, which are highly desired in various fields. The facile strategy described here involves a simple deposition method for the fabrication, thereby having great potential in diverse applications such as image sensors, anti-counterfeit tag, and optical measurement systems.
Mobile software applications have to cope with a particular environment that involves small size, limited resources, high autonomy requirements, competitive business models and many other challenges. To provide development guidelines that respond to these needs, several practices have been introduced; however, it is not clear how these guidelines may contribute to solve the issues present in the mobile domain. Furthermore, the rapid evolution of the mobile ecosystem challenges many of the premises upon which the proposed practices were designed. In this paper, we present a survey of the literature on software assurance practices for mobile applications, with the objective of describing them and assessing their contribution and success. We identified, organized and reviewed a body of research that spans in three levels: software development processes, software product assurance practices, and software implementation practices. By carrying out this literature survey, we reviewed the different approaches that researchers on Software Engineering have provided to address the needs that raise in the mobile software development arena. Moreover, we review the evolution of these practices, identifying how the constant changes and modernization of the mobile execution environment has impacted the methods proposed in the literature. Finally, we introduced discussion on the application of these practices in a real productive setting, opening an area for further research that may determine if practitioners have followed the proposed assurance paradigms. 相似文献
The purpose of present study was to develop and evaluate methods to assess stimulation responses of the lumbar extensors, as part of a longer‐term goal of detecting fatigue during prolonged sitting. Three stimulation frequencies (2, 5, and 8 Hz) were tested in separate stages, which include 3 stimulation trains and 4 sampling blocks. Repeated measures analyses of variance were used to determine whether any significant differences in mean stimulation responses occurred with respect to stimulation frequency, sampling block, and stimulation train. Reliability of measured stimulation responses was assessed within and between sampling blocks using intraclass correlation coefficients. Stimulation frequencies significantly affected the stimulation responses and time‐to‐potentiation differed between the 3 stimulation frequencies; it was highest for 2 Hz stimulation. All 3 stimulation frequencies resulted in excellent reliability within and between sampling blocks. Use of the current protocol at 2 Hz is recommended as appropriate to measure the lumbar extensors status during prolonged sitting. 相似文献