排序方式: 共有11条查询结果,搜索用时 0 毫秒
1.
After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber, a full system covering all the channels of high voltage was installed. The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber. The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported. The full system of high voltage power supply works stably and reliably. 相似文献
2.
Based on the first ionization chamber (IC) prototype, the structure, working gas component and electrode material of the IC are improved. The test of the improved IC shows that the plateau length is about 2000 V, the plateau slope is less than 0.2%/100 V, the sensitivity is 19.6 pA/rad·h-1, the up-limitation of the linearity can be up to 3.6×105 rad/h, and the applied voltage can be operated to 3500 V. The test results show that the performance of the improved IC meets the requirements of the beam loss monitor. 相似文献
3.
4.
吴智 刘建北 秦中华 伍灵慧 陈昌 陈元柏 陈玛丽 陈锡辉 董明义 关北菊 黄杰 江晓山 金艳 李飞 李仁英 李小男 雷广坤 刘荣光 罗小兰 马骁妍 盛华义 孙汉生 唐晓 王岚 王靓 徐美杭 张建 章红宇 张银鸿 赵豫斌 赵平平 朱科军 朱启明 庄保安 《中国物理 C》2010,34(7):983-987
The BESⅢ drift chamber and its subsystems need a cosmic-ray test after the chamber construction to check the chamber construction quality,testing the joint operation of the whole system and the performance of the chamber.The noise performance,drift time and charge measurements,and the scanning of channels were examined specifically.The preliminary results of the test indicate that the whole system works well. 相似文献
5.
利用宇宙线分别研究了一个小单元漂移室在He/C3H8(60/40)和He/CH4(60/40)两种氦基混合气下的性能.作为比较还测试了在Ar/CO2/CH4(89/10/1)混合气下的性能.研究表明上述氦基混合气的空间分辨和dE/dx分辨好于Ar/CO2/CH4(89/10/1)混合气.使用He/C8H8(60/40)可以获得110μm的空间分辨,在30—40次取样下dE/dx分辨可以达到6%—7%. 相似文献
6.
7.
8.
Design and construction of the first prototype ionization chamber for CSNS and Proton Accelerator (PA) beam loss monitor (BLM) system is reported. The low leakage current (〈0.1 pA), good plateau (≈800 V) and linearity range up to 200 Roentgen/h are obtained in the first prototype. All of these give us good experience for further improving the ionization chamber construction. 相似文献
9.
10.
小单元漂移室用放射源模拟老化的实验研究 总被引:2,自引:0,他引:2
BESⅢ 漂移室(DC)模型用1.85X109 Bq 55Fe 5.9keV X射线放射源作加速老化实验研究.测量了阳极丝电流I和55Fe 5.9keV X射线全能光电峰位随累积电荷量Q的变化,由此得到累积相当BESⅢ DC 5年全天候运行的电荷量(0.07 C/cm)后,漂移室小单元的阳极电流降为初始值的87%;老化率为R=-0.19%/(mC/cm) 相似文献