首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   134篇
  免费   7篇
  国内免费   1篇
数理化   142篇
  2022年   1篇
  2021年   1篇
  2019年   1篇
  2018年   4篇
  2017年   4篇
  2016年   8篇
  2015年   6篇
  2014年   6篇
  2013年   9篇
  2012年   9篇
  2011年   15篇
  2010年   10篇
  2009年   7篇
  2008年   9篇
  2007年   12篇
  2006年   7篇
  2005年   6篇
  2004年   7篇
  2003年   7篇
  2002年   2篇
  2001年   2篇
  1999年   1篇
  1996年   4篇
  1991年   1篇
  1989年   1篇
  1987年   1篇
  1985年   1篇
排序方式: 共有142条查询结果,搜索用时 296 毫秒
1.
2.
3.
The sorption behavior of 235U fission fission products 99Mo and 132Te was studied through batch and dynamic experiments when they were dissolved in 1 to 7M HNO3 solutions. It was found that 99Mo is always totally adsorbed on hydrated SnO2, while 132Te is rather weakly adsorbed, therefore they can be separated from each other although 132Te in the solution still remains contaminated with other radionuclides as well as 99Mo does in the solid.  相似文献   
4.
Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75±10mV per decade) over the concentration range of 1×10–1 to 7×10–6M of Ag+ ion and a detection limit of 3×10–6M, at a wide range of pH (pH 4–7). The response time of the electrode was fast (less than 10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution.  相似文献   
5.
Establishment of a quality system for nuclear analytical laboratories   总被引:1,自引:0,他引:1  
Comprehensive Quality Control (QC) and Quality Assurance (QA) Program is stated on the quality policy, organization, methods and records for nuclear analytical laboratories which are necessary for improvement of productivity, to upgrade the performance, credibility and reputation. The proper and complete identification of quality elements for management and technical requirements are being written in Quality Manual as well as analytical and organizational procedures and working instructions according to ISO 17025 standard. Technical ability of gamma, X-ray and a/b laboratories in the Center has been checked by participation in proficiency test, critical technical variables, and quality results. Performance of quality system has been controlled by external audit inspection, progress reports and service to clients. The present study is a framework of the model project of IAEA, coded RER/2/004, which has resulted self-sustainable accreditation from the national body, TURKAK. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   
6.
We consider supplier development decisions for prime manufacturers with extensive supply bases producing complex, highly engineered products. We propose a novel modelling approach to support supply chain managers decide the optimal level of investment to improve quality performance under uncertainty. We develop a Poisson–Gamma model within a Bayesian framework, representing both the epistemic and aleatory uncertainties in non-conformance rates. Estimates are obtained to value a supplier quality improvement activity and assess if it is worth gaining more information to reduce epistemic uncertainty. The theoretical properties of our model provide new insights about the relationship between the degree of epistemic uncertainty, the effectiveness of development programmes, and the levels of investment. We find that the optimal level of investment does not have a monotonic relationship with the rate of effectiveness. If investment is deferred until epistemic uncertainty is removed then the expected optimal investment monotonically decreases as prior variance increases but only if the prior mean is above a critical threshold. We develop methods to facilitate practical application of the model to industrial decisions by a) enabling use of the model with typical data available to major companies and b) developing computationally efficient approximations that can be implemented easily. Application to a real industry context illustrates the use of the model to support practical planning decisions to learn more about supplier quality and to invest in improving supplier capability.  相似文献   
7.
8.
In this study, the solid-state reaction mechanism and kinetics were investigated for production of anhydrous sodium metaborate (NaBO2), an industrially and technologically important boron compound. To assess the kinetics of solid-state production of NaBO2, the chemical reaction between borax (Na2B4O7) and sodium hydroxide (NaOH) was investigated by use of the thermal analysis techniques thermogravimetry (TG) and differential thermal analysis (DTA). DTA curves obtained under non-isothermal conditions at different heating rates (5, 10 and 20 °C/min), revealed five endothermic peaks corresponding to five solid-state reactions occurring at 70, 130, 295, 463, and 595 °C. The stages of the solid-state reaction used for production NaBO2 were also analyzed by XRD, which showed that at 70 and 130 °C, Na2B4O7 and NaOH particles contacted between the grains, and diffusion was initiated at the interface. However, there was not yet any observable formation of NaBO2. Formation of NaBO2 was initiated and sustained from 295 to 463 °C, and then completed at 595 °C; the product was anhydrous NaBO2. Activation energies (E a) of the solid-state reactions were calculated from the weight loss based on the Arrhenius model; it was found that in the initial stages of the solid-state reaction E a values were lower than in the last three steps.  相似文献   
9.
Traditional criterions are not sufficient to predict accurately the recurrence of transitional cell carcinoma of the urinary bladder. Therefore, we aimed to evaluate the AgNORs via total AgNOR area/nucleus area (TAA/NA) for each cell as a prognostic parameter, in TCC of urinary bladder. Tumor tissues of 20 consecutive cases of male bladder cancer patients were divided into two groups as middle differentiated (LG) and high grade (HG). The extra-tumoral tissue (ETT) samples of 10 males served as control group. A second control group (HC) consisted of five healthy and normal bladder tissue samples. The 3 microm of sections from each paraffin embedded tumoral, extra-tumoral and normal tissue samples served as patient and control groups. After deparaffinization and rehydratation steps, silver (AgNO(3)) staining of nucleolar organizer regions-associated proteins (AgNORs) was performed. Instead of Giemsa stain, we used Hematoxylin for contra staining. The images of the 100 analyzable nuclei from each tissue sample, transferred by means of a video camera and video capture card from microscope and recorded onto a computer. Software was prepared in Delphi language for analysis. Mean (E+02) TAA/NA values of HC, ETT, LG and HG groups were 6.97+2.80, 5.70+1.82, 7.80+3.22 and 9.24+3.88, respectively. Statistical comparisons have shown significant differences between all groups.In conclusion, mean TAA/NA per cell has a potential to be a prognostic parameter. Therefore, further evaluation of big patient series will be useful.  相似文献   
10.
In this study, the thermal behavior in terms of glass transition (T g), degradation, and thermal stability of four commercial new-generation posterior bulk fill composites (Surefill SDR, Dentsply; Quixfill, Dentsply; Xtrabase, Voco; and Xtrafill, Voco) activated by light-emitting diodes (LEDs) was analyzed by thermogravimetric analysis (TG), differential scanning calorimetry (DSC), and dynamic mechanical analysis (DMA). The activation energies (E a) for the decomposition of the dental resins were calculated based on the Kissinger and Doyle kinetic models from the peaks of the endothermic curves obtained when the specimens were heated at four different temperatures (5, 10, 15, and 20 °C min?1) during DSC. The results show that the Xtrabase composite displayed the highest T g (120 °C at a 5 °C min?1 heating rate) and E a (157.64 kJ mol?1) values associated with thermal degradation from the main chain of the polymer.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号