A range of potentially bioactive ceramic coatings, based on combinations of either hydroxyapatite (HA) or titanium oxide nanoparticles with carbon nanotubes (CNTs), have been deposited on metallic substrates, using electrophoretic deposition (EPD). Sol–gel derived, ultrafine HA powders (10–70 nm) were dispersed in multi-wall nanotube-containing ethanol suspensions maintained at pH = ∼3.5 and successfully coated onto Ti alloy wires at 20 V for 1–3 min For TiO2/CNT coatings, commercially available titania nanopowders and surface-treated CNTs in aqueous suspensions were co-deposited on stainless steel planar substrates. A field strength of 20 V/cm and deposition time of 4 min were used working at pH = 5. Although the co-deposition mechanism was not investigated in detail, the evidence suggests that co-deposition occurs due to the opposite signs of the surface charges (zeta potentials) of the particles, at the working pH. Electrostatic attraction between CNTs and TiO2 particles leads to the creation of composite particles in suspension, consisting of TiO2 particles homogenously attached onto the surface of individual CNTs. Under the applied electric field, these net negatively charged “composite TiO2/CNT” elements migrate to and deposit on the anode (working electrode). The process of EPD at constant voltage conditions was optimised in both systems to achieve homogeneous and reasonably adhered deposits of varying thicknesses on the metallic substrates.相似文献
Unprecedented levels of internal order are obtained in multiwalled carbon nanotubes grown by chemical vapor deposition with a nitrogen‐doping level of 3% in work reported by Windle and co‐workers on p. 760. Not only is each of the tubular layers of the same orientation (chirality), but they also appear to be in three‐dimensional crystallographic register with one another as shown by the hkl reflections on the cover. The tubes are also straighter and thicker than pure carbon equivalents. The layers are either pure zigzag or pure armchair with spacings close to that of graphite. 相似文献
We have investigated the application of an electronic feedback technique recently reported by Repasky et al. [Appl. Opt. 45, 9013 (2006)] to an injection-locked semiconductor diode laser. We find that without electronic feedback, the injection-locked slave laser will only follow the master for less than 1 GHz, but once the electronic feedback is applied, the slave laser is capable of following for more than 20 GHz, corresponding to the full scan range of the master laser. 相似文献
Clinical and immunocytochemical analysis of twenty eight cases of giant cell tumour of bone was performed in this study. The results revealed that nine of the cases were benign, while the other nineteen were malignant. The female to male ratio was 2.5:1. The average age incidence was 28.18 years. The most common site of occurrence was the femur. anti endothelial antibody revealed negative immunocytochemical reaction of the stromal cells and giant cells for both benign and malignant cases; While using anti-HLA-DR antibody demonstrated positive immune reaction of some of the strumal and giant cells of all the cases examined. 相似文献
OBJECT: The authors studied the reliability of a new method for noninvasive assessment of cerebral perfusion pressure (CPP) in head-injured patients in which mean arterial blood pressure (ABP) and transcranial Doppler middle cerebral artery mean and diastolic flow velocities are measured. METHODS: Cerebral perfusion pressure was estimated (eCPP) over periods of continuous monitoring (20 minutes-2 hours, 421 daily examinations) in 96 head-injured patients (Glasgow Coma Scale score < 13) who were admitted to the intensive care unit. All patients were sedated, paralyzed, and ventilated. The eCPP and the measured CPP (ABP minus intracranial pressure, measured using an intraparenchymal microsensor) were compared. The correlation between eCPP and measured CPP was r=0.73; p < 10(-6). In 71% of the examinations, the estimation error was less than 10 mm Hg and in 84% of the examinations, the error was less than 15 mm Hg. The method had a high positive predictive power (94%) for detecting low CPP (< 60 mm Hg). The eCPP also accurately reflected changes in measured CPP over time (r > 0.8; p < 0.001) in situations such as plateau and B waves of intracranial pressure, arterial hypotension, and refractory intracranial hypertension. A good correlation was found between the average measured CPP and eCPP when day-by-day variability was assessed in a group of 41 patients (r=0.71). CONCLUSIONS: Noninvasive estimation of CPP by using transcranial Doppler ultrasonography may be of value in situations in which monitoring relative changes in CPP is required without invasive measurement of intracranial pressure. 相似文献
Combinatorial chemistry has proven to be a valuable tool for the development of new compounds. In the pharmaceutical industry, where combinatorial chemistry began, the approach has been instrumental in the high-speed development of new drugs. Due to the overwhelming success of the combinatorial methodology in the pharmaceutical industry, it has been recently applied to materials development. We have recently developed a combinatorial factory capable of preparing and evaluating on the order of 100 organic clear coatings in a day.
One of the most challenging aspects of the creation of the combinatorial factory was the development of the high throughput screening (HTS) methods for the primary coating properties of interest such as optical clarity, abrasion resistance, adhesion, and weatherability. For each property, an entirely new method was developed that allowed for rapid measurement of these properties on very small samples. This paper describes various aspects of the development of these novel measurement systems including the correlation of the HTS methods with conventional, industry standard measurement methods. 相似文献
Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near‐infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9 pmol cm?2 of the transition‐metal‐based ICI agent. As a proof of concept, we use ICI for the in vivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal‐to‐noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. 相似文献
Alternating layer, carbon nanotubes-nanocrystal composite films, comprising multi-walled carbon nanotubes (MWCNTs) and iron oxide (Fe(3)O(4)) nanocrystals, have been fabricated via electrophoretic deposition (EPD) on stainless steel and gold substrates. Low field-high current and high field-low current EPD schemes were integrated to produce the composite films. The low field-high current EPD approach produced porous mats from an aqueous suspension of the MWCNTs, while the high field-low current EPD approach produced tightly packed nanocrystal films from a dispersion of the nanocrystals in hexane. Large electric fields applied during the nanocrystal EPD and strong van der Waals interactions among the nanocrystals facilitated the formation of tightly packed nanocrystal films atop the MWCNT mats to create CNT mat-nanocrystal film composites. The surface coverage and homogeneity of the nanocrystal films improved with repeated deposition of the nanocrystals on the same mat. The assembly of nanotube mats on top of the CNT mat-nanocrystal film composite confirmed the feasibility of multilayered CNT mat-nanocrystal film heterostructures suitable for a range of devices. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) techniques were employed to characterize the surface coverage, homogeneity, and topology of these composite films. 相似文献
The SIR-C/X-SAR imaging radar took its first flight on the Space Shuttle Endeavour in April 1994 and flew for a second time in October 1994. This multifrequency radar has fully polarimetric capability at L- and C-band, and a single polarization at X-band (X-SAR). The Endeavour missions were designated the Space Radar Laboratory-1 (SRL-1) and -2 (SRL-2). Calibration of polarimetric L- and C-band data for all the different modes SIR-C offers is an especially complicated problem. The solution involves extensive analysis of pre-flight test data to come up with a model of the system, analysis of in-flight test data to determine the antenna pattern and gains of the system during operation, and analysis of data from over fourteen calibration sites distributed around the SIR-C/X-SAR orbit track. The SRL missions were the first time a multifrequency polarimetric imaging radar employing a phased array antenna has been flown in space. Calibration of SIR-C data products involved some unique technical problems given the complexity of the radar system. In this paper, the approach adopted for calibration of SIR-C data is described and the calibration performance of the data products is presented 相似文献