Emerging soft ionotronics better match the human body mechanically and electrically compared to conventional rigid electronics. They hold great potential for human-machine interfaces, wearable and implantable devices, and soft machines. Among various ionotronic devices, ionic junctions play critical roles in rectifying currents as electrical p–n junctions. Existing ionic junctions, however, are limited in electrical and mechanical performance, and are difficult to fabricate and degrade. Herein, the design, fabrication, and characterization of tough transient ionic junctions fabricated via 3D ionic microgel printing is reported. The 3D printing method demonstrates excellent printability and allows one to fabricate ionic junctions of various configurations with high fidelity. By combining ionic microgels, degradable networks, and highly charged biopolymers, the ionic junctions feature high stretchability (stretch limit 27), high fracture energy (>1000 Jm−2), excellent electrical performance (current rectification ratio >100), and transient stability (degrade in 1 week). A variety of ionotronic devices, including ionic diodes, ionic bipolar junction transistors, ionic full-wave rectifiers, and ionic touchpads are further demonstrated. This study merges ionotronics, 3D printing, and degradable hydrogels, and will motivate the future development of high-performance transient ionotronics. 相似文献
This paper introduces a Transimpedance Amplifier (TIA) design capable of producing an incremental input resistance in the ohmic range, for input signals in the microampere range, such as are encountered in the design of instrumentation for electrochemical ampero-metric sensors, optical-sensing and current-mode circuits. This low input-resistance is achieved using an input stage incorporating negative feedback. In a Cadence simulation of an exemplary design using a 180 nm CMOS process and operating with?±?1.8 V supply rails, the input resistance is 1.05 ohms and the power dissipation is 93.6 µW. The bandwidth, for a gain of 100 dBohm, exceeded 9 MHz. For a 1µA, 1 MHz sinusoidal input signal the Total Harmonic Distortion, with this gain, is less than 1%. The input referred noise current with zero photodiode capacitance is 2.09 pA/√Hz and with a photodiode capacitance of 2pF is 8.52 pA/√Hz. Graphical data is presented to show the effect of a photodiode capacitance varying from 0.5 to 2 pF, when the TIA is used in optical sensing. In summary, the required very low input resistance, at a low input current level (µA) is achieved and furthermore a Table is included comparing the characteristics and a widely used Figure of Merit (FOM) for the proposed TIA and similar published low-power TIAs. It is apparent from the Table that the FOM of the proposed TIA is better than the FOMs of the other TIAs mentioned.
We propose methodology for estimation of sparse precision matrices and statistical inference for their low-dimensional parameters in a high-dimensional setting where the number of parameters p can be much larger than the sample size. We show that the novel estimator achieves minimax rates in supremum norm and the low-dimensional components of the estimator have a Gaussian limiting distribution. These results hold uniformly over the class of precision matrices with row sparsity of small order \(\sqrt{n}/\log p\) and spectrum uniformly bounded, under a sub-Gaussian tail assumption on the margins of the true underlying distribution. Consequently, our results lead to uniformly valid confidence regions for low-dimensional parameters of the precision matrix. Thresholding the estimator leads to variable selection without imposing irrepresentability conditions. The performance of the method is demonstrated in a simulation study and on real data. 相似文献
Films of indium selenide was deposited onto glass and indium tin oxide coated glass substrates in acidic medium using chemical bath deposition at room temperature. Indium sulphate and sodium selenosulphate were used as precursors of In3+ and Se2?, respectively. The structural, surface morphological and optical properties of the deposited films were studied. Diffractograms in structural study revealed the deposited material is In2Se3 films. Controlled bath conditions resulted in the evolution of the In2Se3 microrod-like morphology. The optical band gap of the film was found to be 1.7 eV. 相似文献
Social media plays an increasingly prominent role in the interaction between impact assessments and society. Impact assessment is thus becoming part of social networks that are claimed to be able to improve interaction between actors in impact assessment processes. By investigating the use of social media in impact assessment and planning processes of national linear infrastructure development, we explore how social media impinge on participatory practices and how the potential of social media is realized in the current use related to public participation processes. The study focuses on experiences among national developers working in road, rail, electricity, gas, and metro infrastructures in Denmark. The article shows that the current use of social media in public participatory practices is limited to branding and on-way communication and that the increasing use of social media in linear infrastructure planning gives rise to a variety of concerns among developers that are related to especially organizational cultures, perception of the target groups, and prioritization of resources. 相似文献
Carbon quantum dots (CQDs) have emerged as potential alternatives to classical metal-based semiconductor quantum dots (QDs) due to the abundance of their precursors, their ease of synthesis, high biocompatibility, low cost, and particularly their strong photoresponsiveness, tunability, and stability. Light is a versatile, tunable stimulus that can provide spatiotemporal control. Its interaction with CQDs elicits interesting responses such as wavelength-dependent optical emissions, charge/electron transfer, and heat generation, processes that are suitable for a range of photomediated bioapplications. The carbogenic core and surface characteristics of CQDs can be tuned through versatile engineering strategies to endow specific optical and physicochemical properties, while conjugation with specific moieties can enable the design of targeted probes. Fundamental approaches to tune the responses of CQDs to photo-interactions and the design of bionanoprobes are presented, which enable biomedical applications involving diagnostics and therapeutics. These strategies represent comprehensive platforms for engineering multifunctional probes for nanomedicine, and the design of QD probes with a range of metal-free and emerging 2D materials. 相似文献
Single-mode optical waveguides of 1 mm width are fabricated by thermal indiffusion so that Na+ is replaced by K+ in a simple soda-lime glass substrate. PbCl2 is selectively vacuum evaporated on to the waveguide surface as a sensitive layer (cladding). The thickness of the cladding is varied from 170 nm to 480 nm, with clad length from 2 mm to 6 mm. The prism-film coupling method with an He-Ne laser ( = 632.8 nm) is used for characterization. The output light intensity of a TM-mode is detected by a silicon photovoltaic detector. The waveguides are tested for different gases (O2, H2, CO2, N2, Cl2, H2O), in an airtight glass chamber. The presence of only Cl2 in the surrounding air ambient reduces the output, even at a few p.p.m.. The Cl2 gas concentration is varied from 3 p.p.m. to 1.5%.There are slight changes in sensitivity with variation in the cladding thickness and length. A drastic change in sensitivity for different concentration ranges is observed as three distinct regions. The response time over a few p.p.m. to hundreds of p.p.m. is around 5 s and beyond 500 p.p.m. is around 2 s. 相似文献
We present practical algorithms for accelerating distance queries on models made of trimmed NURBS surfaces using programmable Graphics Processing Units (GPUs). We provide a generalized framework for using GPUs as coprocessors in accelerating CAD operations. By supplementing surface data with a surface bounding-box hierarchy on the GPU, we answer distance queries such as finding the closest point on a curved NURBS surface given any point in space and evaluating the clearance between two solid models constructed using multiple NURBS surfaces. We simultaneously output the parameter values corresponding to the solution of these queries along with the model space values. Though our algorithms make use of the programmable fragment processor, the accuracy is based on the model space precision, unlike earlier graphics algorithms that were based only on image space precision. In addition, we provide theoretical bounds for both the computed minimum distance values as well as the location of the closest point. Our algorithms are at least an order of magnitude faster and about two orders of magnitude more accurate than the commercial solid modeling kernel ACIS. 相似文献