全文获取类型
收费全文 | 85篇 |
免费 | 8篇 |
学科分类
工业技术 | 93篇 |
出版年
2023年 | 1篇 |
2022年 | 8篇 |
2021年 | 7篇 |
2020年 | 2篇 |
2019年 | 2篇 |
2018年 | 9篇 |
2017年 | 1篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 1篇 |
2013年 | 2篇 |
2012年 | 2篇 |
2011年 | 4篇 |
2010年 | 1篇 |
2009年 | 1篇 |
2008年 | 4篇 |
2007年 | 6篇 |
2006年 | 5篇 |
2005年 | 1篇 |
2004年 | 5篇 |
2003年 | 3篇 |
2002年 | 2篇 |
2001年 | 1篇 |
1999年 | 2篇 |
1998年 | 5篇 |
1997年 | 3篇 |
1996年 | 2篇 |
1995年 | 2篇 |
1993年 | 3篇 |
1992年 | 2篇 |
1989年 | 1篇 |
排序方式: 共有93条查询结果,搜索用时 15 毫秒
61.
Tohru Shiga Takashi Ohta Yoshiharu Hirose Akane Okada Toshio Kurauchi 《Journal of Materials Science》1993,28(5):1293-1299
The dynamic viscoelasticity of polymeric composites consisting of silicone gel and polymethacrylic acid cobalt(II) salt (PMACo) particles was studied in d.c. electric fields. It was measured by applying sinusoidally varying shear strain or compressive strain to the composites. It was found that the electric fields enhanced the storage and loss moduli of the composites, and changed the loss tangent (electroviscoelastic effect). The amount of the electroviscoelastic effect was influenced by the content of absorbed water in the PMACo particle, the fraction of PMACo particles, and the intensity of the electric field. It also depended on the amplitude and frequency of the applied strain. The increments of the compressive moduli due to the electroviscoelastic effect were much larger than those of the shear moduli. 相似文献
62.
Mitsunobu Kawamura Yusuke Sunada Hidetomo Kai Nobuyuki Koike Akane Hamada Hitoshi Hayakawa Ren‐Hua Jin Hideo Nagashima 《Advanced Synthesis \u0026amp; Catalysis》2009,351(13):2086-2090
Mononuclear cordinatively unsaturated iron(II) complexes having a triazacyclononane ligand were developed as highly efficient and environmentally friendly catalysts for the atom‐transfer radical polymerization (ATRP). These iron catalysts showed high performance in the well‐controlled ATRP of styrene, methacrylates, and acrylates. The high reactivity of these catalysts led to well‐controlled polymerization and block copolymerization even with lower catalyst concentrations. 相似文献
63.
Shenyan Huang Ke An Yan Gao Akane Suzuki 《Metallurgical and Materials Transactions A》2018,49(3):740-751
Constrained γ/γ′ lattice misfit as a function of temperature (room temperature, 871 °C, 982 °C, 1093 °C, and 1204 °C) is measured by neutron diffraction on the first-generation Ni-based single-crystal superalloy René N4 and second-generation superalloys René N5, CMSX4, and PWA1484. All the alloys studied show negative misfit at temperatures above 871 °C. For René N4, René N5, and PWA1484, the misfit becomes less negative at temperatures above 1093 °C, possibly due to either the chemistry effect or internal stress relaxation. The magnitude of the misfit shows a qualitative agreement with Caron’s misfit model based on Vegard’s coefficients. The Re-free alloy René N4 was found to have a larger γ lattice parameter and γ/γ′ misfit due to higher fractions of Cr, Ti, and Mo. After 100 hours of annealing at high temperatures, René N5 shows a more negative misfit than the misfit after the standard heat treatment. 相似文献
64.
A study on pesticide runoff from paddy fields to a river in rural region--1: field survey of pesticide runoff in the Kozakura River, Japan 总被引:2,自引:0,他引:2
Runoff characteristics of nine kinds of herbicides from paddy fields were surveyed in the Kozakura River, that is one of the tributaries flowing into the Lake of Kasumigaura, over a period of 23 April to 30 June (before and after rice transplantation) of year. The flow rates of river water and the concentrations of herbicides in the river water were measured every day in May and every 2 days in April and June at six survey sites along the river. The runoff characteristics of herbicides were elucidated by taking account of the rainfall data, the detailed application data (application date and quantities of herbicides applied to each paddy field in a region), and their physico-chemical properties. The runoff rates (the runoff/application amounts ratio) were calculated for each herbicide, resulting in the range of 8.2-22.4%. The runoff rates were correlated fairly well with octanol-water partition coefficient, logP(ow), rather than with water solubility of herbicides. 相似文献
65.
Motonaga A Akazawa K Takahashi S Yamamoto Y Tsukada H Inagawa K Yamakawa T Hashiba M 《Computer methods and programs in biomedicine》2004,73(3):183-188
This article describes a method for simultaneously displaying several images on a screen during an online multimedia presentation. Users with 'REALPLAYER' software and Web browsers can view images with synchronous audio on their personal computers via the Internet. Medical researchers and physicians often find it useful to compare images after treatment with those before treatment, by displaying several arranged images simultaneously. Medical care providers can browse this type of multimedia content in their offices and universities at their convenience. There presently exist two methods for creating multimedia content with voice and images using RealSystem technology. Electronic lectures of otorhinolaryngology explaining new surgical procedures for patients with chronic otitis media were created with this method and made available to otorhinolaryngologists through the Internet. 相似文献
66.
Extraction of thiamylal in serum using hydrophilic acetonitrile with subzero-temperature and salting-out methods 总被引:1,自引:0,他引:1
For high-performance liquid chromatography (HPLC) of thiamylal, one of the barbiturates, the drug in serum samples was extracted by two alternative liquid-liquid extraction techniques using hydrophilic acetonitrile as a solvent and subzero-temperature and salting-out methods. Acetonitrile was mixed with the sample, separated by cooling at -20 degrees C or addition of sodium chloride, and injected directly into the HPLC apparatus. In both the methods, thiamylal was extracted effectively in the acetonitrile phase and pH adjustment of the sample was not required. The salting-out extraction method is rapid and would be suitable for quantitation of drugs in many samples. To avoid coextraction of added salt, the subzero-temperature extraction method was applied to identification of thiamylal by gas chromatography/mass spectrometry and liquid chromatography-tandem mass spectrometry. 相似文献
67.
Dynamic viscoelasticity of silicone gels having many lines of dispersed iron particles under the influence of external magnetic fields was studied. The particulate composite enhanced its elastic modulus by action of magnetic fields. The magnetroviscoelastic behavior was caused by the cohesive forces between magnetically polarized particles and was analyzed using a simple model of induced dipole-induced dipole interactions. The presented results provide insight into the relationship between macroscopic viscoelastic behavior of the composite gels and the microscopic bondings between dispersed particles. © 1995 John Wiley & Sons, Inc. 相似文献
68.
69.
On the basis of the phenomenon that hydrophilic acetonitrile is separated from the aqueous phase at -20 degrees C, we employed a novel extraction method, "subzero-temperature liquid-liquid extraction", to extract benzodiazepines (estazolam and triazolam) from serum or aqueous solution for liquid chromatography. A 1:1 mixture of acetonitrile and the specimen was cooled at -20 degrees C for 20 min to separate the acetonitrile and aqueous phases. The acetonitrile phase was directly injected into a high-performance liquid chromatograph. Recovery rates of the drugs following the first subzero-temperature liquid-liquid extraction were 50.3 +/- 0.6-54.0 +/- 0.9%, which were lower than those (73.9 +/- 3.3-80.6 +/- 0.6% and 81.6 +/- 4.7-96.1 +/- 2.6%) of the first conventional liquid-liquid extraction using diethyl ether and solid-phase extraction using a Sep-Pak C18 column, respectively. However, three to four repeated subzero-temperature liquid-liquid extractions and conventional liquid-liquid extractions resulted in recovery of almost 100% of the drugs. In the chromatogram of the benzodiazepines recovered from serum by the subzero-temperature extraction, no coextracted component interfered with determination of the drugs. Detection limits of the drugs were 0.02-0.08 microgram/mL, and coefficients of variance were 1.14-2.17% suggesting high reproducibility. 相似文献
70.
The authors have compared the results of scalp reductions with extenders with their earlier results of scalp reductions without extenders. The extenders seem to prevent "stretch-back" and provide 30 to 86% more effectiveness when a second reduction is performed 4 weeks later. 相似文献