首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   181篇
  免费   2篇
  国内免费   1篇
环境安全   184篇
  2023年   1篇
  2022年   1篇
  2019年   1篇
  2018年   2篇
  2017年   1篇
  2016年   3篇
  2015年   6篇
  2014年   6篇
  2013年   12篇
  2012年   15篇
  2011年   25篇
  2010年   6篇
  2009年   9篇
  2008年   22篇
  2007年   19篇
  2006年   16篇
  2005年   7篇
  2004年   4篇
  2003年   8篇
  2002年   11篇
  2001年   4篇
  2000年   1篇
  1995年   1篇
  1988年   1篇
  1955年   1篇
  1954年   1篇
排序方式: 共有184条查询结果,搜索用时 15 毫秒
51.
This study was performed to elucidate the distribution, concentration trend and possible source of polycyclic aromatic hydrocarbons (PAHs) in surface water and bed sediments of the Hungarian upper section of the Danube River and the Moson Danube branch. A total of 217 samples (water and sediments) were collected from four different sampling sites in the period of 2001–2010 and analysed for the 16 priority US Environmental Protection Agency PAHs. Concentrations of total 16 PAHs (∑PAHs) in water samples ranged from 25 to 1,208 ng/L, which were predominated by two- and three-ring PAHs. The ∑PAH concentrations in sediments ranged from 8.3 to 1,202.5 ng/g dry weight. Four-ring PAHs including fluoranthene and pyrene were the dominant species in sediment samples. A selected number of concentration ratios of specific PAH compounds were calculated to evaluate the possible sources of PAH contamination. The ratios reflected a pattern of pyrogenic input as a major source of PAHs. The levels of PAHs determined were compared with other sections of the Danube and other regions of the world.  相似文献   
52.
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods ofat least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0+/-1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.  相似文献   
53.
The automatic real-time environmental radiation surveillance network of Catalonia (Spain) comprises two subnetworks; one with 9 aerosol monitors and the other with 8 Geiger monitors together with 2 water monitors located in the Ebre river. Since September 2006, several improvements were implemented in order to get better quality and quantity of data, allowing a more accurate data analysis. However, several causes (natural causes, equipment failure, artificial external causes and incidents in nuclear power plants) may produce radiological measured values mismatched with the own station background, whether spurious without significance or true radiological values. Thus, data analysis for a 50-month period was made and allowed to establish an easily implementable statistical criterion to find those values that require special attention. This criterion proved a very useful tool for creating a properly debugged database and to give a quick response to equipment failures or possible radiological incidents. This paper presents the results obtained from the criterion application, including the figures for the expected, raw and debugged data, percentages of missing data grouped by causes and radiological measurements from the networks. Finally, based on the discussed information, recommendations for the improvement of the network are identified to obtain better radiological information and analysis capabilities.  相似文献   
54.
Font R  Moltó J  Egea S  Conesa JA 《Chemosphere》2011,85(3):516-524
The increase in electronic waste, including cellular telephones, worldwide is a worrying reality. For this reason, urgent action on the management of these wastes is necessary within a framework that respects the environment and human health. Mobile phone components can be physically segregated through grinding at the dismantling sites, in order to reuse or reprocess (via chemical or physical recycling) the recovered plastics and valuable metals. A kinetic study of the thermal decomposition of a mobile phone case has been carried out under different conditions by thermogravimetry. Several experiments were performed in a nitrogen atmosphere (pyrolysis runs) and also in an oxidative atmosphere with two different oxygen concentrations (10% and 20% oxygen in nitrogen). Dynamic runs and dynamic+isothermal runs have been carried out to obtain much decomposition data under different operating conditions. Moreover some TG-MS runs were performed in order to better understand the thermal decomposition of a mobile phone case and identify some compounds emitted during the controlled heating of this material. A scheme of two independent reactions for pseudocomponents has been proposed for the pyrolysis process. For the combustion runs, the scheme proposed includes two pyrolytic reactions competing with other two reactions with formation of an intermediate residue, and finally the reaction of oxidation/burning of the intermediate residue. Furthermore, pyrolysis and combustion runs at 500 °C in a horizontal laboratory furnace were carried out. More than 50 compounds, including carbon oxides, light hydrocarbons, and polycyclic aromatic hydrocarbons (PAHs) have been identified and quantified. The main semivolatile compounds detected were phenol and styrene. Furthermore, polychlorodibenzo-p-dioxin and polychlorodibenzofurans (PCDD/Fs) and dioxin-like PCBs produced were analyzed. In the combustion run, PCDDs were obtained in higher amounts than PCDFs and HxCDD was the most emitted homologue.  相似文献   
55.
Plants of one evergreen oak (Quercus ilex) and three deciduous oaks (Q. faginea, with small leaves; Q. pyrenaica and Q. robur, with large leaves) were exposed both to filtered air and to enhanced ozone levels in Open-Top Chambers. Q. faginea and Q. pyrenaica were studied for the first time. Based on visible injury, gas exchange, chlorophyll content and biomass responses, Q. pyrenaica was the most sensitive species, and Q. ilex was the most tolerant, followed by Q. faginea. Functional leaf traits of the species were related to differences in sensitivity, while accumulated ozone flux via stomata (POD1.6) partly contributed to the observed differences. For risk assessment of Mediterranean vegetation, the diversity of responses detected in this study should be taken into account, applying appropriate critical levels.  相似文献   
56.
Foliage dust contains heavy metal that may have harmful effects on human health. The elemental contents of tree leaves and foliage dust are especially useful to assess air environmental pollution. We studied the elemental concentrations in foliage dust and leaves of Acer pseudoplatanus along an urbanization gradient in Vienna, Austria. Samples were collected from urban, suburban and rural areas. We analysed 19 elements in both kind of samples: aluminium, barium, calcium, copper, iron, potassium, magnesium, sodium, phosphor, sulphur, strontium and zinc. We found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for aluminium, barium, iron, lead, phosphor and selenium. Elemental concentrations of leaves were significantly higher in urban than in rural area for manganese and strontium. Urbanization changed significantly the elemental concentrations of foliage dust and leaves and the applied method can be useful for monitoring the environmental load.  相似文献   
57.
Pyrolysis and combustion runs at 850°C in a horizontal laboratory furnace were carried out on different parts of a mobile phone (printed circuit board, mobile case and a mixture of both materials). The analyses of the carbon oxides, light hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), polychlorodibenzo-p-dioxin, polychlorodibenzofurans (PCDD/Fs), and dioxin-like PCBs are shown. Regarding semivolatile compounds, phenol, styrene, and its derivatives had the highest yields. In nearly all the runs the same PAHs were identified, naphthalene being the most common component obtained. Combustion of the printed circuit board produced the highest emission factor of PCDD/Fs, possibly due to the high copper content.  相似文献   
58.
The chronologies and sediment accumulation rates for a lake sediment sequence from Lough Carra (Co. Mayo, western Ireland) were established by applying the constant initial concentration (CIC) and constant rate of supply (CRS) hypotheses to the measured 210Pbexcess profile. The resulting chronologies were validated using the artificial fallout radionuclides 137Cs and 241Am, which provide independent chronostratigraphic markers for the second half of the 20th century. The validity of extrapolating the derived CIC and CRS dates below the 210Pb dating horizon using average sedimentation rates was investigated using supplementary paleolimnological information and historical data. Our data confirm that such an extrapolation is well justified at sites characterised by relatively stable sedimentation conditions.  相似文献   
59.
This work describes the development, optimization and validation of an analytical method for the simultaneous detection and identification of 74 pharmaceutically active compounds (PhACs), from various therapeutic groups, in both environmental (ground and surface water) and wastewaters (WW). The method is based on the simultaneous extraction of all target compounds by solid phase extraction (SPE), using a hydrophilic-lipophilic balanced polymer followed by ultra high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS). Two selected reaction monitoring (SRM) transitions have been monitored per compound in order to fulfil the EC guidelines, as well as to ensure an accurate identification of target compounds in the samples. Quantification is performed by internal standard approach, applying 24 specific isotopically labeled compounds. The main advantages of the developed method, besides the selectivity and reliability of the results, is its high throughput. All compounds are extracted in a single step and the instrumental analysis lasts 5 min (NI mode) + 8 min (PI mode), allowing fast throughput of samples. The limits of detection range from 0.01 to 50 ng L−1, depending on the matrix, for most of the compounds. Finally, the method developed has been applied to the analysis of pharmaceuticals in the Ebro river basin (NE Spain).  相似文献   
60.
Fish oils are one of the main sources of ω-3 fatty acids. However, they can present elevated levels of some lipophilic pollutants, such as hexabromocyclododecanes (HBCDs). Since data about HBCDs in fish oil samples are very limited, in this study, 25 samples of fish oil for feed and food have been analyzed. Total HBCDs, as well as, α-, β- and γ-diastereoisomers have been determined. Total HBCDs ranged from 0.09 to 26.8 ng g−1, with higher concentrations in fish oil for feed (average value of 9.69 ng g−1) than those for food (1.14 ng g−1). Concentrations of α-HBCD (average value of 4.12 ng g−1 in feed samples and 0.48 ng g−1 in food samples) and γ-HBCD (5.05 and 0.43 ng g−1 respectively) were higher than that of β-HBCD (0.52 and 0.19 ng g−1 respectively) in most of the samples. However, none of them was predominant in the samples. Concentrations of HBCDs were compared to concentrations of other pollutants and correlation between dioxin and dioxin-like PCBs levels and HBCDs levels were observed. Intake of HBCDs was calculated for fish oil with human consumption purposes and it ranged from 0.08 to 5.38 ng HBCDs d−1, which could contribute significantly to HBCDs total intake. Enantiomeric fractions were also determined. No clear enrichment was observed for γ-HBCD, while (−)-α-HBCD enrichment was detected in some samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号