首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   62篇
  免费   0篇
环境安全   62篇
  2019年   1篇
  2018年   2篇
  2014年   6篇
  2013年   11篇
  2012年   3篇
  2011年   1篇
  2009年   1篇
  2008年   4篇
  2007年   10篇
  2006年   4篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2002年   3篇
  2001年   1篇
  2000年   2篇
  1999年   1篇
  1995年   1篇
  1990年   1篇
  1984年   1篇
  1982年   2篇
  1981年   1篇
  1978年   1篇
排序方式: 共有62条查询结果,搜索用时 15 毫秒
21.
Biodiesel fuel is gradually replacing petroleum-based diesel oil use. Despite the biodiesel being considered friendlier to the environment, little is known about its effects in aquatic organisms. In this work we evaluated whether biodiesel exposure can affect oxidative stress parameters and biotransformation enzymes in armored catfish (Pterygoplichthys anisitsi, Loricariidae), a South American endemic species. Thus, fish were exposed for 2 and 7 d to 0.01 mL L−1 and 0.1 mL L−1 of pure diesel, pure biodiesel (B100) and blends of diesel with 5% (B5) and 20% (B20) biodiesel. Lipid peroxidation (malondialdehyde) levels and the activities of the enzymes glutathione S-transferase, superoxide dismutase, catalase and glutathione peroxidase were measured in liver and gills. Also, DNA damage (8-oxo-7, 8-dihydro-2′-deoxyguanosine) levels in gills and 7-ethoxyresorufin-O-deethylase activity in liver were assessed. Pure diesel, B5 and B20 blends changed most of the enzymes tested and in some cases, B5 and B20 induced a higher enzyme activity than pure diesel. Antioxidant system activation in P. anisitsi was effective to counteract reactive oxygen species effects, since DNA damage and lipid peroxidation levels were maintained at basal levels after all treatments. However, fish gills exposed to B20 and B100 presented increased lipid peroxidation. Despite biodiesel being more biodegradable fuel that emits less greenhouse gases, the increased lipid peroxidation showed that biofuel and its blends also represent hazards to aquatic biota.  相似文献   
22.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in a sediment core and in samples of surface sediment and paddy soil collected from the Toyano lagoon and Kameda basin in Niigata, Japan, were analyzed to elucidate the temporal trends of their concentrations in the lagoon sediment and the relationship between the sediment and the paddy soil. The mass balance of these pollutants was also estimated to determine their long-term fate in surface waters. An analysis by chemical mass balance identified the agrochemicals pentachlorophenol and 2,4,6-trichlorophenyl 4-nitrophenyl ether as the major sources of PCDD/Fs. On the basis of the findings regarding the mass balance in the Kameda basin over the last 40 years, we estimate that more than half the input of PCDD/Fs to the Kameda basin has disappeared. We suggest that the PCDD/Fs that flowed out from the paddy fields have been transferred to the lower basin.  相似文献   
23.
24.
Microbial fuel cells (MFCs) have gained a lot of attention recently as a mode of converting organic matter into electricity. In this study, a compost-based microbial fuel cell that generates bioelectricity by biodegradation of organic matter is developed. Grass cuttings, along with leaf mold, rice bran, oil cake (from mustard plants) and chicken droppings (waste from chickens) were used as organic waste. The electric properties of the MFC under anaerobic fermentation condition were investigated along with the influence of different types of membranes, the mixing of fly ash, and different types of electrode materials. It is observed that the maximum voltage was increased by mixing fly ash. Cellophane showed the highest value of voltage (around 350 mV). Bamboo charcoal is good for anode material; however carbon fiber is better for the cathode material in terms of optimization of power generated. This developed MFC is a simple cell to generate electricity from organic waste.  相似文献   
25.
Japanese medaka (Oryzias latipes) has been widely used for the evaluation of the toxicity of endocrine active chemicals (EACs) and other chemicals as well as for monitoring the adverse effects of effluent discharges in relation to sexual development and function. It is useful for these evaluations for many reasons including the following: 1) it has a short life cycle facilitating studies extending over long phases of development and over multigenerations, 2) it is easy to rear, 3) male and female phenotypes can easily be distinguished on the basis of secondary sex characteristics, and 4) a genetic marker (DMY) is available for identifying the true genotypic sex. Several biomarkers have been found to be useful for identifying the effects of exposure to estrogenic and androgenic chemicals in medaka and they include increased levels of hepatic vitellogenin (VTG) and testis-ova induction in males for exposure to estrogenic chemicals, and decreased levels of hepatic VTG in females and an altered morphology of dorsal and anal fins and formation of papillae for androgenic chemicals. In this paper, we present a critical analysis of the use of medaka as a test species for studies of endocrine disruption and report on the use of sex-related genetic markers and alterations in gonadal development, including the induction of testis-ova formation, for assessing the disruptive effects of EACs. In this paper, we focus on some of the more recent studies and findings.  相似文献   
26.
Some invasive ants form large networks of mutually non-aggressive nests, i.e., supercolonies. The Argentine ant Linepithema humile forms much larger supercolonies in introduced ranges than in its native range. In both cases, it has been shown that little gene flow occurs between supercolonies of this species, though the mechanism of gene flow restriction is unknown. In this species, queens do not undertake nuptial flight, and males have to travel to foreign nests and cope with workers before gaining access to alien queens. In this study, we hypothesized that male Argentine ants receive interference from workers of alien supercolonies. To test this hypothesis, we conducted behavioral and chemical experiments using ants from two supercolonies in Japan. Workers attacked males from alien supercolonies but not those from their own supercolonies. The level of aggression against alien males was similar to that against alien workers. The frequency of severe aggression against alien males increased as the number of recipient workers increased. Cuticular hydrocarbon profiles, which serve as cues for nestmate recognition, of workers and males from the same supercolony were very similar. Workers are likely to distinguish alien males from males of their own supercolony using the profiles. It is predicted that males are subject to considerable aggression from workers when they intrude into the nests of alien supercolonies. This may be a mechanism underlying the restricted gene flow between supercolonies of Argentine ants. The Argentine ant may possess a distinctive reproductive system, where workers participate in selecting mates for their queens. We argue that the aggression of workers against alien males is a novel form of reproductive interference.  相似文献   
27.
Appropriate treatment of asbestos waste is a significant problem. In Japan, inertization of asbestos-containing waste by novel techniques approved by the Ministry of the Environment is now promoted. A quantitative method of testing with high sensitivity to the asbestos levels present in the inertization products is required for the approval process, but many testing methods are only qualitative. Thus, we have developed an evaluation method for asbestos in inertized products, consisting of the extraction of fibers from inertized products and determination of fiber number concentration by transmission electron microscopy. We adopted this testing method to evaluate thermally treated asbestos. It was found that fiber number concentrations of thermally treated asbestos decreased with increased treatment temperature, and were below the environmental level (102 Mf/g) at more than 1000 °C for chrysotile and crocidolite and more than 1400 °C for amosite and other amphibole forms of asbestos.  相似文献   
28.
Congener profiles of PCB and a proposed new set of indicator congeners   总被引:2,自引:0,他引:2  
Ishikawa Y  Noma Y  Mori Y  Sakai S 《Chemosphere》2007,67(9):1838-1851
In this study, a new method for calculating total PCB and toxic equivalents (TEQ) of coplanar PCB (Co-PCB) was proposed, called the 'PCB dual method'. This method analysed various kinds of technical PCB, samples contaminated by technical PCB and byproduct PCB. In the PCB dual method, a data set of 15 indicator congeners was utilized for the calculations, having IUPAC nos. #3, #8, #28, #52, #77, #101, #105, #118, #126, #138, #153, #180, #194, #206 and #209. The 15 congener set was chosen from the major congeners, determined by HRGC/HRMS analysis, in 18 technical PCB, Kanechlor, Aroclor, Clophen and Chlorofen, and 20 other samples, such as indoor air, flue gases, emission gases, municipal solid waste (MSW), ash and sealant. To obtain total PCB and TEQ of Co-PCB, the intermediate sum for the concentration of the 15 congeners was multiplied by each multiplication factor. As a result, we obtained the average factor used to calculate total PCB in technical PCB and other samples. For technical PCB, the factor was 3.01, while for indoor air samples, flue and emission gases, MSW, ash and sealants, the factors were 3.92, 4.16, 3.68, 4.52 and 4.77, respectively. Moreover, the factor used to calculate the TEQ of Co-PCB in Kanechlor and other source samples were also obtained. The factors for Kanechlor, indoor air samples and emission gases from a cement plant were in the order of 10(-5), while the factor for flue gases in a MSW incinerator was in the order of 10(-3). These data were valuable for the rough estimation of the TEQ of Co-PCB without separation from other PCB before individual measurements.  相似文献   
29.
The hydrothermal degradation pathways of decabromodiphenyl ether during hydrothermal treatment were investigated. After an initial "Heating time", the reaction runs were carried out at constant temperature (heating to 300 degrees C and keeping temperature) and pressure (8MPa) in a SUS316 stainless steel micro autoclave filled with water. Some decomposition of decabromodiphenyl ether was observed over 200 degrees C, and it was decomposed by more than 99% after 10 min at 300 degrees C. The reactivities of bromine on para and meta substituents were relatively high, while its reactivity on ortho bromine was extremely low. The formations of polybrominated dibenzo-p-dioxins and furans (PBDD/DFs) were observed in the early stages of the reactions at around 300 degrees C. The TCDD toxicity equivalency (TCDD-EQs) of the by-products was determined based on relative potencies (REPs EC(5TCDD)) with the Dioxin-Responsive-Chemical Activated Luciferase gene eXpression (DR-CALUX) bioassays technology. These results indicated that the risk of formation of PBDD/DFs in the hydrothermal degradation of deca-BDE was low, and it would be possible to reduce the TCDD-EQs value by adding some catalyst or alkali, or extending processing time.  相似文献   
30.
Nine polychlorinated biphenyl (PCB) congeners (2-chlorobiphenyl, 3-chlorobiphenyl, 4-chlorobiphenyl, 2,3,4-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl, 2,3',4,4',5-pentachlorobiphenyl, 3,3',4,4',5-pentachlorobiphenyl, 2,2',4,4',5,5'-hexachlorobiphenyl, and decachlorobiphenyl) were dechlorinated by the sodium dispersion method (SD) at low temperature (60 degrees C). The dechlorination of 4-chlorobiphenyl was the fastest among the three monochlorobiphenyls. As for the other six congeners, we investigated the major dechlorination pathways. Although reaction selectivity was not very sensitive to the position of the chlorine substituent, the chlorines at the para position were slightly easier to dechlorinate than those at the ortho or meta positions. The decomposition rate increased with the total numbers of chlorine substituents. A chlorine situated between two other chlorines showed a high reactivity. When the numbers of chlorines on each of the phenyl rings were different, the reactions occurred on the more substituted ring. In the degradation of 4-chlorobiphenyl at elevated temperature (160 degrees C), we investigated the structures of the polymerized products and whether all the organic chlorinated compounds degraded finally or not. As for the dimers, p-quarterphenyl (QP) and m,p-QP were detected but not o-QP, m-QP, o,p-QP, o,m-QP, or the mono- to tetra-chlorinated QPs. Compounds with a molecular weight of 534.4183 or 758.6713 were detected. They were considered to have C40H54 or C56H86 as their molecular formula. The compounds were most probably the polymerized products resulting from coupling of hexadecane or two hexadecanes and two phenylcyclohexadienes. It was thought the dechlorination and the polymerization were the main reactions. All of many detected compounds were hydrocarbons without chlorines, and no peaks originating from organic chlorinated compounds were observed by mass spectroscopic (MS) methods.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号