首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   315篇
  免费   4篇
  国内免费   3篇
环境安全   322篇
  2023年   7篇
  2022年   7篇
  2021年   8篇
  2019年   3篇
  2018年   5篇
  2017年   7篇
  2016年   8篇
  2015年   14篇
  2014年   13篇
  2013年   20篇
  2012年   19篇
  2011年   37篇
  2010年   22篇
  2009年   17篇
  2008年   31篇
  2007年   26篇
  2006年   25篇
  2005年   13篇
  2004年   8篇
  2003年   10篇
  2002年   11篇
  2001年   4篇
  2000年   1篇
  1995年   1篇
  1988年   2篇
  1959年   1篇
  1955年   1篇
  1954年   1篇
排序方式: 共有322条查询结果,搜索用时 15 毫秒
91.
The UV (254 nm) and UV/VUV (254/185 nm) photolysis of two anti-inflammatory drugs, ibuprofen and ketoprofen, have been studied in aqueous solutions as a possible process for the removal of non-biodegradable compounds.We have examined the effects of dissolved oxygen and initial target concentration. Upon irradiation at 254 nm, the decomposition rate of ketoprofen is almost forty times higher as it of ibuprofen whilst VUV irradiation only increased the ibuprofen decomposition rate. The presence of dissolved oxygen accelerated the photodegradation of ibuprofen, whereas no effect was observed on the degradation of ketoprofen. The maximum quantum yield for the phototransformation was 0.2. The rate of mineralization in both cases was ∼60%, even after 1 h of treatment and this suggests the formation of stable by-products which were identified using GC-MS and HPLC-MS, respectively.  相似文献   
92.
This work describes the development, optimization and validation of an analytical method for the simultaneous detection and identification of 74 pharmaceutically active compounds (PhACs), from various therapeutic groups, in both environmental (ground and surface water) and wastewaters (WW). The method is based on the simultaneous extraction of all target compounds by solid phase extraction (SPE), using a hydrophilic-lipophilic balanced polymer followed by ultra high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS). Two selected reaction monitoring (SRM) transitions have been monitored per compound in order to fulfil the EC guidelines, as well as to ensure an accurate identification of target compounds in the samples. Quantification is performed by internal standard approach, applying 24 specific isotopically labeled compounds. The main advantages of the developed method, besides the selectivity and reliability of the results, is its high throughput. All compounds are extracted in a single step and the instrumental analysis lasts 5 min (NI mode) + 8 min (PI mode), allowing fast throughput of samples. The limits of detection range from 0.01 to 50 ng L−1, depending on the matrix, for most of the compounds. Finally, the method developed has been applied to the analysis of pharmaceuticals in the Ebro river basin (NE Spain).  相似文献   
93.
Font R  Moltó J  Egea S  Conesa JA 《Chemosphere》2011,85(3):516-524
The increase in electronic waste, including cellular telephones, worldwide is a worrying reality. For this reason, urgent action on the management of these wastes is necessary within a framework that respects the environment and human health. Mobile phone components can be physically segregated through grinding at the dismantling sites, in order to reuse or reprocess (via chemical or physical recycling) the recovered plastics and valuable metals. A kinetic study of the thermal decomposition of a mobile phone case has been carried out under different conditions by thermogravimetry. Several experiments were performed in a nitrogen atmosphere (pyrolysis runs) and also in an oxidative atmosphere with two different oxygen concentrations (10% and 20% oxygen in nitrogen). Dynamic runs and dynamic+isothermal runs have been carried out to obtain much decomposition data under different operating conditions. Moreover some TG-MS runs were performed in order to better understand the thermal decomposition of a mobile phone case and identify some compounds emitted during the controlled heating of this material. A scheme of two independent reactions for pseudocomponents has been proposed for the pyrolysis process. For the combustion runs, the scheme proposed includes two pyrolytic reactions competing with other two reactions with formation of an intermediate residue, and finally the reaction of oxidation/burning of the intermediate residue. Furthermore, pyrolysis and combustion runs at 500 °C in a horizontal laboratory furnace were carried out. More than 50 compounds, including carbon oxides, light hydrocarbons, and polycyclic aromatic hydrocarbons (PAHs) have been identified and quantified. The main semivolatile compounds detected were phenol and styrene. Furthermore, polychlorodibenzo-p-dioxin and polychlorodibenzofurans (PCDD/Fs) and dioxin-like PCBs produced were analyzed. In the combustion run, PCDDs were obtained in higher amounts than PCDFs and HxCDD was the most emitted homologue.  相似文献   
94.
Foliage dust contains heavy metal that may have harmful effects on human health. The elemental contents of tree leaves and foliage dust are especially useful to assess air environmental pollution. We studied the elemental concentrations in foliage dust and leaves of Acer pseudoplatanus along an urbanization gradient in Vienna, Austria. Samples were collected from urban, suburban and rural areas. We analysed 19 elements in both kind of samples: aluminium, barium, calcium, copper, iron, potassium, magnesium, sodium, phosphor, sulphur, strontium and zinc. We found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for aluminium, barium, iron, lead, phosphor and selenium. Elemental concentrations of leaves were significantly higher in urban than in rural area for manganese and strontium. Urbanization changed significantly the elemental concentrations of foliage dust and leaves and the applied method can be useful for monitoring the environmental load.  相似文献   
95.
Pyrolysis and combustion runs at 850°C in a horizontal laboratory furnace were carried out on different parts of a mobile phone (printed circuit board, mobile case and a mixture of both materials). The analyses of the carbon oxides, light hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), polychlorodibenzo-p-dioxin, polychlorodibenzofurans (PCDD/Fs), and dioxin-like PCBs are shown. Regarding semivolatile compounds, phenol, styrene, and its derivatives had the highest yields. In nearly all the runs the same PAHs were identified, naphthalene being the most common component obtained. Combustion of the printed circuit board produced the highest emission factor of PCDD/Fs, possibly due to the high copper content.  相似文献   
96.
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods ofat least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0+/-1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.  相似文献   
97.
98.
The short wavelength UV-induced photocrosslinking of vinylbenzylthymine (VBT) based photoresist polymers was investigated in a polymer-dye water soluble system. The goal of the study was to determine whether the presence of UV-absorbing dye additives would prevent the photocrosslinking from occurring. It was found that the photoreactivity of the VBT polymer was not hindered significantly even when the amount of dye additive was comparable to the amount of thymine. Further, adding dyes to the photoresist allowed obtaining good quality images in one step. This study may provide a basis for testing VBT-containing polymers for use in controlled release applications.  相似文献   
99.
Following the detection of 236U in depleted uranium (DU) ammunition used during the Balkans conflict in the 1990s, concern has been expressed about the possibility that other nuclides from the nuclear fuel cycle and, in particular, transuranium nuclides, might be present in this type of ammunition. In this paper, we report the results of uranium and plutonium analyses carried out on a depleted uranium penetrator recovered from a target site in southern Serbia. Our data show the depleted nature of the uranium and confirm the presence of trace amounts of plutonium in the penetrator. The activity concentration of (239+240)PU, at 45.4+/-0.7 Bq kg(-1), is the highest reported to date for any penetrator recovered from the Balkans. This concentration, however, is comparable to that expected to be present naturally in uranium ores and, from a radiological perspective, would only give rise to a very small increase in dose to exposed persons compared to that from the DU itself.  相似文献   
100.
As representatives of primary producers, algae and cyanobacteria play an important role in assessing the risk of chemicals. However, the list of standard algal species commonly used for toxicity testing comprises very few species so that there is an urgent demand to identify further non-standard species which can be used for higher-tier risk assessment in general and the analysis of species sensitivity distributions in particular. In this study, four measuring techniques to assess growth inhibition were compared using five non-standard and two standard algal species and 3,5-dichlorophenol as reference substance. Regarding sensitivity and suitability, the measuring techniques were ranked in the following descending order: delayed fluorescence, prompt fluorescence, photometric absorbance, and microscopic cell count. All five non-standard species fulfilled the validity criteria if tested with delayed fluorescence.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号