首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
用滴涂法和电化学聚合法制备了聚中性红/纳米二氧化硅修饰电极(PNR/nano-SiO2/GCE),并用循环伏安法和交流阻抗法研究了修饰电极表面的电化学行为。实验表明,该修饰电极对抗坏血酸(AA)表现出良好的电催化氧化性能,探讨了复合修饰电极协同增效作用的机理。用线性扫描伏安法研究了AA浓度与峰电流之间线性关系,在pH2.0的磷酸盐缓冲溶液中,AA氧化峰电流在1.8×10-6~5.0×10-3mol/L浓度范围内呈良好的线性关系,检出限为5.4×10-7mol/L(S/N=3)。该修饰电极制备简单,可用于药品及果蔬食品中抗坏血酸的直接测定。  相似文献   

2.
Ye D  Luo L  Ding Y  Chen Q  Liu X 《The Analyst》2011,136(21):4563-4569
A novel nitrite sensor was fabricated based on a graphene/polypyrrole/chitosan nanocomposite film modified glassy carbon electrode. The nanocomposite film was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The electron transfer behaviour of the modified electrodes was investigated in [Fe(CN)(6)](3-)/(4-) redox probe using cyclic voltammetry and electrochemical impedance spectroscopy. Differential pulse voltammetry and amperometry were used to study the electrochemical properties of the proposed sensor. Under optimum conditions, the sensor exhibited good reproducibility and stability for nitrite determination. Linear response was obtained in the range of 0.5-722 μM with a detection limit of 0.1 μM (S/N = 3) for nitrite determination.  相似文献   

3.
An electrochemical sensor was fabricated by construction of nickel nanowires on the surface of poly(p‐aminophenol) (PPAP) modified glassy carbon electrode. The electrochemical response of dicofol, a known pesticide and used for agricultural activities such as cyclic voltammetry and differential pulse voltammetry, were investigated and the results were compared with those obtained unmodified electrodes. Following the optimization of NaOH concentration, polymerization cycle number, Ni nanowire amount, the linear range for the dicofol was studied and found as 0.83–30.7 μmol L?1 (R2=0.9981) at Ni/PPAP/GCE with a 0.08 μmol L?1 detection limit according to S/N=3. Finally, the proposed Ni/PPAP/GCE sensor was successfully applied for the dicofol analysis in soil samples. The characterization of the developed surface was carried out by scanning electron microscopy and X‐Ray photoelectron spectroscopy.  相似文献   

4.
《Electroanalysis》2006,18(8):748-756
Amperometric biosensors based on the corresponding oxidase enzyme with poly(neutral red) redox mediator have been developed for the determination of glucose and pyruvate. The enzymes have been immobilized on top of poly(neutral red) modified carbon film electrodes with glutaraldehyde as the cross‐linking agent. The biosensors were characterized by cyclic voltammetry and by electrochemical impedance spectroscopy. The glucose biosensor exhibited a linear response in the range 90 μM to 1.8 mM with a detection limit of 22 μM and the pyruvate biosensor in the range 90 to 600 μM with a detection limit of 34 μM. The relative standard deviations were found to be 2.1% (n=3) and 2.8% (n=4) respectively. The interference effects of various compounds were also studied. The glucose content of several types of wine and the amount of pyruvate in onion and garlic were determined and the results were compared with those obtained by standard spectrophotometric methods.  相似文献   

5.
Here we investigate the use of 3D printed graphene/poly(lactic acid) (PLA) electrodes for quantifying trace amounts of Hg, Pb, and Cd. We prepared cylindrical electrodes by sealing a 600 μm diameter graphene/PLA filament in a pipette tip filled with epoxy. We characterized the electrodes using scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry in ferrocene methanol. The physical characterization showed a significant amount of disorder in the carbon structure and the electrochemical characterization showed quasi‐reversible behavior without any electrode pretreatment. We then used unmodified graphene/PLA electrode to quantify Hg, and Pb and Cd in 0.01 M HCl and 0.1 M acetate buffer using square wave anodic stripping voltammetry. We were able to quantify Hg with a limit of detection (LOD) of 6.1 nM (1.2 ppb), but Pb and Cd did not present measurable peaks at concentrations below ~400 nM. We improved the LODs for Pb and Cd by depositing Bi microparticles on the graphene/PLA and, after optimization, achieved clear stripping peaks at the 20 nM level for both ions (4.1 and 2.2 ppb for Pb2+ and Cd2+, respectively). The results obtained for all three metals allowed quantification below the US Environmental Protection Agency action limits in drinking water.  相似文献   

6.
A nano-composite of DNA/poly(p-aminobenzensulfonic acid) bi-layer modified glassy carbon electrode as a biosensor was fabricated by electro-deposition method. The DNA layer was electrochemically deposited on the top of electropolymerized layer of poly(p-aminobenzensulfonic acid) (Pp-ABSA). Scanning electron microscopy, X-ray photoelectron spectroscopy and electrochemical impedance spectrum were used for characterization. It demonstrated that the deposited Pp-ABSA formed a 2-D fractal patterned nano-structure on the electrode surface, and which was further covered by a uniform thin DNA layer. Cyclic voltammetry and electrochemical impedance spectrum were used to characterize the deposition, and demonstrated the conductivity of the Pp-ABSA layer. The biosensor was applied to the detection of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). In comparison with DNA and Pp-ABSA single layer modified electrodes, the composite bi-layer modification provided superior electrocatalytic actively towards the oxidation of DA, UA and AA, and separated the originally overlapped differential pulse voltammetric signals of UA, DA and AA oxidation at the bare electrode into three well-defined peaks at pH 7 solution. The peak separation between AA and DA, AA and UA was 176 mV and 312 mV, respectively. In the presence of 1.0 mM AA, the anodic peak current was a linear function of the concentration of DA in the range 0.19-13 microM. The detection limit was 88 nM DA (s/n=3). The anodic peak current of UA was also a linear function of concentration in the range 0.4-23 microM with a detection limit of 0.19 microM in the presence of 0.5 mM AA. The superior sensing ability was attributed to the composite nano-structure. An interaction mechanism was proposed.  相似文献   

7.
In this study, the electrochemical reduction of nitrite was investigated on poly(4‐aminoacetanilide) (PPAA) forming by cyclic voltammetry at the surface of carbon paste electrode. The electrochemical properties of the modified electrode have been studied by cyclic voltammetry and double potential step chronoamperometry. Results showed that in the optimum condition (pH = 0.00) the reduction of nitrite occurred at a potential about 667 mV more positive than that unmodified carbon paste electrode. This amount of electrocatalytic ability is high compared with other electrocatalysts. Using a chronoamperometric method, the catalytic rate constant (k) was calculated 8.4 × 104 cm3 mol‐1 s‐1. Also, the electrocatalytic reduction peak currents was found to be linear with the nitrite concentration in the ranges of 5 × 10‐4 M to 2.5 × 10‐2 M and 2 × 10‐5 M to 7 × 10‐3 M with detection limits (2σ) were determined as 4.5 × 10‐4 M and 1 × 10‐5 M by cyclic voltammetry (CV) and hydrodynamic amperometry methods respectively. Recovery experiments exhibit the satisfactory results.  相似文献   

8.
Shahrokhian S  Rastgar S 《The Analyst》2012,137(11):2706-2715
Mixtures of gold-platinum nanoparticles (Au-PtNPs) are fabricated consecutively on a multi-walled carbon nanotubes (MWNT) coated glassy carbon electrode (GCE) by the electrodeposition method. The surface morphology and nature of the hybrid film (Au-PtNPs/MWCNT) deposited on glassy carbon electrodes is characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. The modified electrode is used as a new and sensitive electrochemical sensor for the voltammetric determination of cefotaxime (CFX). The electrochemical behavior of CFX is investigated on the surface of the modified electrode using linear sweep voltammetry (LSV). The results of voltammetric studies exhibited a considerable improvement in the oxidation peak current of CFX compared to glassy carbon electrodes individually coated with MWCNT or Au-PtNPs. Under the optimized conditions, the modified electrode showed a wide linear dynamic range of 0.004-10.0 μM with a detection limit of 1.0 nM for the voltammetric determination of CFX. The modified electrode was successfully applied for the accurate determination of trace amounts of CFX in pharmaceutical and clinical preparations.  相似文献   

9.
Poly 1,8-Diaminonaphtahlene/cysteine (poly 1,8-DAN/Cys) combined with carbon black (CB) nanoparticles are proposed as an excellent sensor for the detection of nitrite ions. To design the electrocatalyst, a simple approach consisting on drop-casting method was applied to disperse carbon black on the surface of glassy carbon electrode, followed by the immobilization of cysteine on the surface of CB nanoparticles. The electrochemical polymerization of 1,8-Diaminonaphthalene was conducted in acidic medium by using cyclic voltammetry. The prepared hybrid material was denoted poly 1,8-DAN /Cys/CB. Several methods were used to characterize the structural and electrochemical behavior of the reported hybrid material including Fourier transform infrared spectroscopy (FTIR), Scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), amperometry and differential pulse voltammetry (DPV). The prepared electrode displayed an outstanding electroactivity towards nitrite ions reflected by an enhancement in the intensity of the current and a decrease of the charge transfer resistance. Poly 1,8-DAN/Cys/CB displayed an excellent sensing performance towards the detection of nitrite with a very low detection limit of 0.25 µM. Two linear ranges of 1–40 µM and 20–210 µM when using amperometry and differential pulse voltammetry (DPV) were obtained respectively. This work highlights the simple preparation of a polymeric film rich in amine and thiol groups for nitrite detection.  相似文献   

10.
Qi Wang  Yanbin Yun 《Mikrochimica acta》2012,177(3-4):411-418
We have investigated the oxidative electrochemistry of nitrite on glassy carbon electrodes modified with cobalt nanoparticles, poly(3,4-ethylenedioxythiophene) (PEDOT), and graphene. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. The results suggest that this new type of electrode combines the advantages of PEDOT-graphene films and cobalt nanoparticles and exhibits excellent electrocatalytic activity towards the oxidation of nitrite. There is a linear relationship between the peak current and the nitrite concentration in the range from 0.5?μM to 240?μM, and the detection limit is 0.15?μM. The modified electrodes also enable the determination of nitrite at low potentials where the noise level and interferences by other electro-oxidizable compounds are weak.
Figure
The present work describes the design of a Co NPs-PEDOT-GE nanocomposite- modified GCE and its electrocatalytic properties toward the oxidation of nitrite. Compared with the Co NPs-GE/GCE (b) or PEDOT-GE/GCE (c), the as-prepared Co NPs-PEDOT-GE/GCE (d) exhibits remarkably enhanced electrocatalytic activity towards nitrite  相似文献   

11.
Here, Pd nanoparticles and poly(taurine) film was prepared on the glassy carbon electrode surface (Pd/Poly(TAU)/GCE) by the rapid electrochemical technique. The proposed composite surface was characterized by scanning electron microscopy(SEM), X‐ray photoelectron spectroscopy(XPS) and electrochemical impedance spectroscopy(EIS). Enhanced electron transfer ability and higher electroactive surface area were achieved at Pd/Poly(TAU)/GCE as compared to the bare GCE and polymer film electrode. The new and highly stable Pd/Poly(TAU)/GCE was employed for the individual and simultaneous determination of hydroquinone and catechol which were environmentally toxic. Under the optimized conditions, HQ and CC were individually determined by using the differantial pulse voltammetry in the linear ranges of 0.008–100 μM and 0.001–100 μM with the detection limits of (LOD) 2.1 nM and 0.68 nM, respectively. In case of simultaneous determination, LODs were found as 10 nM and 0.88 nM for HQ and CC, respectively. The content of both analytes in the real sample analysis was evaluated in the river water and tap water successfully.  相似文献   

12.
《Electroanalysis》2005,17(21):1952-1958
The performance of a poly(1,8‐diaminonaphthalene)‐modified electrode for the determination of the Se(IV) ion in an aqueous medium was investigated with anodic stripping voltammetry without the pretreating of the sample. The experimental parameters for the analysis of Se(IV) were optimized and the characteristics of this polymer‐modified electrode were investigated by using cyclic voltammetry. The Se(IV) ions were chemically deposited onto the surface of the pDAN‐Au electrode in an acidic medium. The detection limit employing the anodic stripping differential pulse voltammetry was 9.0×10?9 M for Se(IV) with 4.4 % of RSD. Satisfactory result for the determination of Se(IV) was acquired employing a certified standard urine reference material, SRM's 2670 (trace element in urine) with 4.1 ppb of SD.  相似文献   

13.
The polymer, poly(vinylferrocenium) (PVF+) modified electrode was developed as the first time herein for the improved electrochemical sensing of DNA based on the oxidation signals of polymer and guanine. The morphologies of polymer film and DNA immobilized polymer film were examined using scanning electron microscope (SEM). The electrochemical behavior of polymer modified electrode was investigated by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the absence/presence of DNA. Experimental parameters, such as the polymeric film thickness, the DNA immobilization time, the concentration of buffer solution, pH and DNA concentration were examined in order to obtain more sensitive and selective electrochemical signals. After optimization studies, DNA hybridization was also investigated.  相似文献   

14.
Gold nanoparticle modified indium tin oxide (ITO) film coated glass electrodes were prepared for the first time through direct electrochemical deposition from 0.5 M H2SO4 containing 0.1 mM HAuCl4. The resulting electrode surfaces were characterized with AFM. Cyclic voltammetry and linear sweep voltammetry (LSV) of arsenic(III) on the modified electrodes were performed. After optimization, a LOD of 5 +/- 0.2 ppb was obtained with 60 s deposition at -0.6 V (vs. SCE) in 1 M HNO3 using LSV.  相似文献   

15.
In this work, a poly(alizarin red)/Graphene composite film modified glassy carbon electrode (PAR/Graphene/GCE) was prepared for simultaneous determination of four DNA bases (guanine, adenine, thymine and cytosine) without any pretreatment. The morphology and interface property of PAR/Graphene films were examined by scanning electron microscopy and electrochemical impedance spectroscopy. The PAR/Graphene/GCE exhibited excellent electrocatalytic activity toward purine (guanine and adenine) and pyrimidine (thymine and cytosine) in 0.1 M phosphate buffer solution (pH 7.4). Under optimum conditions, differential pulse voltammetry was used to detect the oxidation of purine and pyrimidine. The results showed that PAR/Graphene/GCE exhibited well-separated peaks, low detection limit, high sensitivity and wide linear range for simultaneous detection of purine and pyrimidine. The proposed sensor also has good stability and reproducibility. Furthermore, the modified electrode was applied for the detection of DNA bases in a fish sperm DNA sample with satisfactory results.  相似文献   

16.
《Electroanalysis》2017,29(2):609-615
In this work a method for sensitive anodic stripping voltammetric determination of Pb(II) ions using a poly xylenol orange film modified electrode (PXOFME) has been proposed. Poly xylenol orange film (PXOF) was formed on a paraffin impegrenated graphite electrode (PIGE) using electro polymerization method by scanning the potential between −0.5 V to 1.3 V, at a scan rate of 50 mV/s for 30 segments in 0.1 M phosphate buffer solution (PBS) of pH 7. The PXOFME was characterized by scanning electron microscopy (SEM), ATR‐IR spectroscopy, cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The modified electrode has been used to develop a sensitive method for the determination of Pb(II) ions by anodic stripping voltmmetry (ASV). The PXOFME was used to preconcentrate Pb(II) ions through complexation, the complexed metal ions were reduced electrochemically and then stripped anodically from the surface of the electrode. A linear range of 5 μg/L to 413 μg/L with a limit of detection (S/N=3) of 1.6 μg/L was observed for the determination of Pb(II) ions. The method was applied to lead determination in sea water and tap water samples and the results were found to be satisfactory.  相似文献   

17.
Contamination of natural water by mercury (Hg2+) and bismuth (Bi3+) metal ions have been extensively studied due to their toxic effects. A validated square-wave anodic stripping voltammetry (SW-ASV) method for determining Bi3+ and Hg2+ ions individually and simultaneously is described. A new electrochemical sensor was constructed using a gold (Au) electrode that has been modified with poly(1,2-diaminoanthraquinone) (p-1,2-DAAQ). Scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy were used to characterize the p-1,2-DAAQ/Au modified electrode. Factors such as the polymer film thickness, electrolyte, square wave parameters and preconcentration conditions were optimized to improve the performance of the modified Au electrode. Good linear responses were achieved in the concentration ranges of 1–200 μg L−1 and 1–50 μg L−1 forBi3+ and Hg2+, respectively, and the limits of detection were 0.27 μg L−1 (Bi3+) and 0.29 μg L−1 (Hg2+). The interference study results illustrated the high selectivity of the modified electrode for detection of Bi3+ and Hg2+. The proposed SW-ASV method was successfully applied for Bi3+ and Hg2+analyses in different real water samples.  相似文献   

18.
《Electroanalysis》2018,30(2):238-249
A copper nano particles and cerium (IV) oxide modified carbon nanotube based composite on glassy carbon electrode (Cu−CeO2/MWCNT/GCE) was fabricated for simultaneous determination of guanine and adenine. The surface morphology, chemistry and conductance of the prepared electrodes were characterized by scanning electron microscopy (SEM), energy dispersion X‐ray (EDX), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The Cu−CeO2/MWCNT/GCE improved electrochemical behaviour of guanine and adenine compared to other electrodes. The modified electrode was also used for individual and simultaneous determination of guanine and adenine. Under optimized conditions, the calibration curves were obtained linearly in the range of 0.20 to 6.00 μM for the guanine and 0.10 to 8.0 μM for the adenine by differential pulse voltammetry. The limits of detection of guanine and adenine were calculated as 0.128 and 0.062 μM, respectively. Interferences studies were also performed in the presence of inorganic and organic compounds. Moreover, the determination of guanine and adenine contents were carried out in a calf thymus DNA sample by the developed method with satisfactory results.  相似文献   

19.
The electrocatalytic reduction of nitrite has been studied by poly(ortho‐toluidine) films modified carbon paste electrode (P‐OT/MCPE). Cyclic voltammetry and chronoamperometry techniques were used to investigate the suitability of poly(ortho‐toluidine) as a mediator for the electrocatalytic nitrite reduction in aqueous solution with various pH. Results showed that pH 0.00 is the most suitable for this purpose. In the optimum pH, the reduction of nitrite occurs at a potential about 600 mV more positive than unmodified carbon paste electrode. The catalytic reaction rate constant, (kh), was calculated 8.68×102 M?1 s?1 by the data of chronoamperometry. The catalytic reduction peak current was linearly dependent on the nitrite concentration and the linearity range obtained was 5.00×10?4 M–1.90×10?2 M. Detection limit has been found to be 3.38×10?4 M (2σ). This method has been successfully employed for quantification of nitrite in real sample.  相似文献   

20.
In this study, simultaneous determination of toxic hydrazine and nitrite was performed on composite electrodes of poly(Nile blue)(NB), carbon nanotube(CNT) and gold nanoparticles(AuNPs). The prepared AuNPs/CNT/poly(NB)/GCE was used for as a sensor platform for individual and simultaneous determination of hydrazine and nitrite. Electrodes were characterized by HRTEM, SEM, XPS, EIS. The LOD for nitrite and hydrazine was 5.0 μM and 3.1 μM at AuNP/CNT/poly(NB)/GCE, respectively. Also, sensitive amperometric determinations of hydrazine and nitrite were performed and LOD were calculated as 0.33 μM and 0.68 μM, respectively. The method was applied to sausage and river water samples and recovery results were obtained in the range 85–115 %.  相似文献   