首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
刘振华  廖亮 《太阳能学报》2007,28(2):146-150
提出了一种新型紧凑式顺排光滑管束组成的满液式蒸发换热器。在低压条件下对水平光滑顺排管束的小空间内沸腾强化换热特性进行了实验研究,确认了管距、管位置和运行压力对强化换热性能的影响。实验表明存在一个能得到最大强化换热效果的最佳管距,这一最佳管距接近沸腾气泡的脱离直径。压力对强化换热效果也有重要影响:随着压力降低,强化换热效果也逐步减弱。实验结果对高效节能型蒸发换热器设计提供了设计基础。  相似文献   

2.
《Applied Thermal Engineering》2002,22(17):1931-1941
In flooded-type tube bundle evaporators with smooth tubes and general tube gaps, both wall superheat and heat flux are generally quite low and boiling cannot occur on the heated tubes. But when the tube gap is quite small or the enhanced heat transfer tubes are employed, the incipient boiling can occur at low heat flux levels and results in a significant heat transfer enhancement effect. This study investigates experimentally enhancement effects by the restricted space comprising the compact tube bundle and the enhanced tubes for boiling heat transfer of pure water and salt-water mixtures under atmospheric pressure. The experimental results show that the small tube gaps can greatly enhance boiling heat transfer for the compact enhanced tube bundle.  相似文献   

3.
Heat transfer and pressure drop characteristics are investigated here using experimental and analytical techniques for a dimple plate heat exchanger. The analysis uses the log mean temperature difference method (LMTD) in all its calculations. Whilest the shell side flow highly resembles the flow over a rough or wavy plate, the tube side passage in these represents the flow over short hexagonal tube banks with the flowing across the sectional areas between the hexagons having the shape of a benzene ring. Local and global experimental measurements are carried out around the heat exchanger. Furthermore, analytical models for both sides of the heat exchanger were obtained from the literature. Reasonable cross match between experimental and analytical results could be obtained. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
An experimental investigation was carried out on the boiling heat transfer enhancement of water on plain tubes in compact staggered tube-bundle evaporators under atmospheric and sub-atmospheric pressures. The experiment investigated the effects of the tube spacing and positioning and the test pressure on the boiling heat transfer characteristics in restricted spaces of compact tube bundles. The experimental results indicated that for compact tube bundles, the effect of the tube spacing is very significant on the boiling heat transfer. The boiling heat transfer has a maximum enhancement when the tube spacing is so selected as to take an optimum value. The enhanced heat transfer efficiency for the compact bundles would gradually decrease as the test pressure was reduced.  相似文献   

5.
The effectiveness and cost are two important parameters in heat exchanger design. The total cost includes the capital investment for equipment (heat exchanger surface area) and operating cost (for energy expenditures related to pumping). Tube arrangement, tube diameter, tube pitch ratio, tube length, tube number, baffle spacing ratio as well as baffle cut ratio were considered as seven design parameters. For optimal design of a shell and tube heat exchanger, it was first thermally modeled using εNTU method while Bell–Delaware procedure was applied to estimate its shell side heat transfer coefficient and pressure drop. Fast and elitist non-dominated sorting genetic algorithm (NSGA-II) with continuous and discrete variables were applied to obtain the maximum effectiveness (heat recovery) and the minimum total cost as two objective functions. The results of optimal designs were a set of multiple optimum solutions, called ‘Pareto optimal solutions’. The sensitivity analysis of change in optimum effectiveness and total cost with change in design parameters of the shell and tube heat exchanger was also performed and the results are reported.  相似文献   

6.
To determine the combined effects of the heat exchanger tube geometries of advanced light water reactors (ALWRs) passive residual heat removal system (PRHRS) on the nucleate pool boiling heat transfer in a scaled in-containment refueling water storage tank (IRWST), a total of 1,966 data (1,076 with horizontal tubes and 890 with vertical tubes) for q″ versus ΔT has been obtained using various combinations of tube diameters, surface roughness, and tube orientation. The experimental results show that (1) for both horizontal and vertical tubes, increased surface roughness enhances heat transfer whereas increased tube diameter decreases heat transfer, (2) both effects of the surface roughness and the tube diameter on the nucleate pool boiling heat transfer are significantly greater for vertical tubes than horizontal tubes, (3) the effectiveness of two heat transfer mechanisms, i.e., enhanced heat transfer dur to liquid agitation by bubbles generated and reduced heat transfer by the formation of large vapor slugs and bubble coalescence, depends on the combined effects of the heat flux, surface roughness, and the tube orientation. In addition, two different forms of empirical heat transfer correlations are obtained that fit present experimental data within +35 and −20%.  相似文献   

7.
为实现节能降耗,开发了多种强化沸腾传热的高效换热管。以水为工质,在0.1MPa下对垂直光管、烧结多孔管和T槽管进行了池沸腾传热实验研究,并分析了沿管子轴向的温度分布。实验结果表明,烧结多孔管与T槽管能显著降低起始沸腾过热度、强化沸腾传热:烧结多孔管和T槽管的起始沸腾过热度比光管的低1.5K左右;烧结多孔管和T槽管的核态沸腾传热系数分别为光管的2.4~3.2倍和1.6~2.0倍。此外,烧结多孔管和T槽管能降低相同热流密度下的壁面温度,且有利于降低管子轴向的温差。  相似文献   

8.
Flooded evaporators are widely used as compact cooling units to cool liquids. They consist of a shell-and-tube heat exchanger, with the fluid to cool flowing inside the tubes of the bundle and a refrigerant that evaporates over those tubes. Pool boiling on the external surface of the tubes is a very complex process, and therefore the boiling heat transfer coefficients (HTCs) should be determined experimentally. Copper and copper alloys tubes are commonly employed in such heat exchangers, due to their high thermal conductivity and relative low cost. On the other hand, refrigeration and air conditioning sectors are undergoing significant changes caused mainly by the necessity of replacing existing refrigerants with more environmentally friendly ones. This paper reports the experimental determination of the pool boiling HTCs of R-134a and R-417A blend on a smooth copper tube of 18.87 mm diameter, at two saturation temperatures of 10°C and 7°C. Although smooth tubes are not commonly used in shell-and-tube evaporators nowadays, it is a first approach to pool boiling of drop-in refrigerants. The experimental setup and data acquisition are described, the experimental procedure is explained, the data reduction methodology is detailed, and the results are presented and discussed.  相似文献   

9.
R. SMYTH 《传热工程》2013,34(3-4):90-94
The shell-and-tube heat exchanger (SBE), with its tubes held in plate baffles to produce cross flow of the shell-side fluid, has recently been modified to produce a RODbaffle heat exchanger (RBE) free from tube failure due to vibration. The results showed slightly enhanced heat transfer coefficients with significant reductions in pressure loss, leading to reduced cost of exchangers and in some instances smaller exchangers.  相似文献   

10.
Pool boiling heat transfer experiments were carried out on a conventional smooth tube and four enhanced tubes with reentrant surfaces using propane, isobutane and their mixtures as working fluids for six saturation temperatures. The heat transfer performance is very different for different surface-fluid combinations. Compared to the smooth tube, the mixture boiling heat transfer degradation is more significant for the enhanced tubes. The current data are compared with available literature data for the same fluids and also with data for R12 and R134a. Experimental results of boiling hysteresis and for twin-tube bundles are also provided. Further explanations for the different heat transfer performances is provided by means of visualization in an accompanying paper [Y. Chen, M. Groll, R. Mertz, R. Kulenovic, Visualization and mechanisms of pool boiling of propane, isobutane and their mixtures on enhanced tubes with reentrant channels, submitted to Int. J. Heat Mass Transfer (H/S 04016)].  相似文献   

11.
ln desalinization devices and some heat exchangers making use of low‐quality heat energy, both wall temperatures and heat fluxes of heated tubes are quite low and generally cannot cause boiling in flooded‐type tube bundle evaporators with a large tube spacing. But when the tube spacing is very small, boiling in restricted spaces can occur and induce a higher heat transfer than that of a falling film or pool boiling at the same heat flux. This study investigated experimentally the effects of tube spacing, positions of tubes, and heating status of tubes as well as surface status (smooth and roll‐worked) on boiling in restricted spaces in compact horizontal tube bundle evaporators under atmospheric pressure. The experimental results provide a restricted space boiling database for water in smooth and enhanced surface tube bundles. Of particular importance is information concerning the influence of tube spacing of flooded‐type tube bundle evaporators, especially for the case of zero pitch, when the neighboring tubes are contacting each other. © 2001 Scripta Technica, Heat Trans Asian Res, 30(5): 394–401, 2001  相似文献   

12.
Experiments on pool boiling heat transfer from a circumference-interrupted T-finned (CIT) tube and a Thermoexcel-E tube are conducted at system pressures ranging from 1 to 6 bars, with ethyl alcohol and R-113 as the working media. The strong effects of system pressure on the excellent boiling heat transfer performance of the two enhanced boiling tubes are presented. Based on the analyses of boiling vapor-liquid two-phase flow and heat transfer within the microchannels of the two mechanically fabricated porous layers, and by synthesizing experimental data, semiempirical correlations are established for predicting the boiling heat transfer performance of CIT and Thermoexcel-E tubes separately at atmospheric and superatmospheric pressures.© 1999 Scripta Technica, Heat Trans Asian Res, 28(8): 640-648, 1999  相似文献   

13.
Steady heat transfer enhancement has been studied in helically coiled-tube heat exchangers. The outer side of the wall of the heat exchanger contains a helical corrugation which makes a helical rib on the inner side of the tube wall to induce additional swirling motion of fluid particles. Numerical calculations have been carried out to examine different geometrical parameters and the impact of flow and thermal boundary conditions for the heat transfer rate in laminar and transitional flow regimes. Calculated results have been compared to existing empirical formulas and experimental tests to investigate the validity of the numerical results in case of common helical tube heat exchanger and additionally results of the numerical computation of corrugated straight tubes for laminar and transition flow have been validated with experimental tests available in the literature. Comparison of the flow and temperature fields in case of common helical tube and the coil with spirally corrugated wall configuration are discussed. Heat exchanger coils with helically corrugated wall configuration show 80–100% increase for the inner side heat transfer rate due to the additionally developed swirling motion while the relative pressure drop is 10–600% larger compared to the common helically coiled heat exchangers. New empirical correlation has been proposed for the fully developed inner side heat transfer prediction in case of helically corrugated wall configuration.  相似文献   

14.
Experimental investigations of tube side condensation and evaporation in two 3-D enhanced heat transfer (2EHT) tubes were compared to the performance of a smooth surface copper tube. The equivalent outer diameter of all the tubes was 12.7 mm with an inner diameter of 11.5 mm. Both the inner and outer surfaces of the 2EHT tubes are enhanced by longitudinal grooves with a background pattern made up by an array of dimples/embossments. Experimental runs were performed using R410A as the working fluid, over the quality range of 0.2–0.9. For evaporation, the heat transfer coefficient ratio (compares the heat transfer coefficient of the enhanced tube to that of a smooth tube) of the 2EHT tubes is 1.11–1.43 (with an enhanced surface area ratio of 1.03) for mass flux rate that ranges from 80 to 200 kg/m2 s. For condensation, the heat transfer coefficient ratio range is 1.1–1.16 (with an enhanced surface area ratio of 1.03) for mass flux that ranges from 80 to 260 kg/m2 s. Frictional pressure drop values for the 2EHT tubes are very similar to each other. Heat transfer enhancement in the 2EHT tubes is mainly due to the dimples and grooves in the inner surface that create an increased surface area and interfacial turbulence; producing higher heat flux from wall to working fluid, flow separation, and secondary flows. A comparison was performed to evaluate the enhancement effect of the 2EHT tubes using a defined performance factor and this indicates that the 2EHT tubes provides a better heat transfer coefficient under evaporation conditions.  相似文献   

15.
Boiling heat transfer of R-134a on a porous, plasma-coated tube bundle was investigated experimentally to determine the effects of the number of tube rows and the total tube number. The bundle consists of up to four tubes with a pitch-to-diameter-ratio of 1.33. Heat transfer coefficients for a single tube with a porous copper coating were up to four times higher than for a smooth tube. Observations showed that the plasma coating enhanced the heat transfer coefficient in tube bundles as well. The bundle factor of the coated tube bundle showed a similar, slightly increased trend as the smooth tube bundles. The enhancement effect of the coated tubes decreases to a certain extent with an increasing heat flux and decreasing saturation temperature. However, it is significantly less pronounced than trends that have been reported from other investigations. The aim of a stable enhanced coating was confirmed by long-term experiments with steady results.  相似文献   

16.
脉动流体能够使管壳式换热器换热系数得到提高,而自激振荡腔在一定的结构参数和运行参数下能够使流体产生脉动。在管壳式换热器前安装自激振荡腔,使流体流经自激振荡腔产生脉动流动,从而实现管壳式换热器的强化传热。分析了将自激振荡腔用于管壳式换热器强化传热可行性。  相似文献   

17.
Four different semi-empirical models of heat transfer and pressure drop for helically segmented finned tubes in staggered layout were analyzed. The performance of a Helically Segmented Finned Tubes Heat Exchanger on an industrial scale was obtained and the predictions were compared with experimental data. The method used for thermal analysis is the Logarithmic Mean Temperature Difference (LMTD). Comparisons between predictions and experimental data show a precision greater than 95% in heat transfer for a combination between the Kawaguchi and Gnielinski models at a flue gas Reynolds number, based on the outside bare tube, of about 10,000. In the case of pressure drop, there is a precision of approximately 90% for the Weierman model at a Reynolds number, based on the outside bare tube, of about 10,000. And so, the results show that the best flow regime in which heat transfer and pressure drop are optimum, is for a Reynolds number (based on the outside bare tube) of about 10,000.  相似文献   

18.
In this article, experimental analysis is done on shell‐and‐tube heat exchanger of a marine vessel for removal of fouling using optimum surface‐cleaning techniques. The main objective is to compare the performance of the heat exchanger before and after maintenance. Two identical deteriorated systems of heat exchangers are taken and real‐time analysis is conducted. The log data are taken before and after undergoing maintenance for the two systems. Two different cleaning techniques are used, namely, chemical cleaning and mechanical cleaning. Detailed calculations are made for the shell‐and‐tube heat exchanger. From the obtained data, comparisons are made for different parameters on the tube side such as friction factor, heat transfer coefficient and pressure drop, as well as total heat transfer rate on the shell side. From the analysis and comparison, it was found that greater heat transfer takes place for the tubes cleaned using the chemical cleaning method than for tubes cleaned by the mechanical cleaning method. Pressure drop is found to be less for chemical cleaning method than mechanical cleaning method. This indicates that the fouling effect is reduced for tubes cleaned by the chemical cleaning method, and furthermore these tubes remain corrosion‐resistant for longer periods of time.  相似文献   

19.
In the present study, experiments were performed to examine the characteristics of flow boiling heat transfer and pressure drop of a refrigerant R410A flowing vertically upward in small copper rectangular and triangular tubes with hydraulic diameters of 1.04 and 0.88 mm, respectively, for the development of a high-performance heat exchanger using small tubes or minichannels for air-conditioning systems. Their characteristics were clarified by comparing the previous experimental data of the small circular tube (1.00 mm internal diameter). In the rectangular and triangular tubes, the pressure drop was found to be slightly lower and the heat transfer was much better than in the circular tube.  相似文献   

20.
This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号