Many countries in Europe are investing in fuel cell bus technology with the expected mobilization of more than 1200 buses across Europe in the following years. The scaling-up will make indispensable a more effective design and management of hydrogen refueling stations to improve the refueling phase in terms of refueling time and dispensed quantity while containing the investment and operation costs. In the present study, a previously developed dynamic lumped model of a hydrogen refueling process, developed in MATLAB, is used to analyze tank-to-tank fuel cell buses (30–40 kgH2 at 350 bar) refueling operations comparing a single-tank storage with a multi-tank cascade system. The new-built Aalborg (DK) hydrogen refueling station serves as a case study for the cascade design. In general, a cascading refueling approach from multiple storage tanks at different pressure levels provides the opportunity for a more optimized management of the station storage, reducing the pressure differential between the refueling and refueled tanks throughout the whole refueling process, thus reducing compression energy. This study demonstrates the validity of these aspects for heavy-duty applications through the technical evaluation of the refueling time, gas heating, compression energy consumption and hydrogen utilization, filling the literature gap on cascade versus single tank refueling comparison. Furthermore, a simplified calculation of the capital and operating expenditures is conducted, denoting the cost-effectiveness of the cascade configuration under study. Finally, the effect of different pressure switching points between the storage tanks is investigated, showing that a lower medium pressure usage reduces the compression energy consumption and increases the station flexibility.  相似文献   

2.
The foreseen uptake of hydrogen mobility is a fundamental step towards the decarbonization of the transport sector. Under such premises, both refueling infrastructure and vehicles should be deployed together with improved refueling protocols. Several studies focus on refueling the light-duty vehicles with 10 kgH2 up to 700 bar, however less known effort is reported for refueling heavy-duty vehicles with 30–40 kgH2 at 350 bar. The present study illustrates the application of a lumped model to a fuel cell bus tank-to-tank refueling event, tailored upon the real data acquired in the 3Emotion Project. The evolution of the main refueling quantities, such as pressure, temperature, and mass flow, are predicted dynamically throughout the refueling process, as a function of the operating parameters, within the safety limits imposed by SAE J2601/2 technical standard. The results show to refuel the vehicle tank from half to full capacity with an Average Pressure Ramp Rate (APRR) equal to 0.03 MPa/s are needed about 10 min. Furthermore, it is found that the effect of varying the initial vehicle tank pressure is more significant than changing the ambient temperature on the refueling performances. In conclusion, the analysis of the effect of different APRR, from 0.03 to 0.1 MPa/s, indicate that is possible to safely reduce the duration of half-to-full refueling by 62% increasing the APRR value from 0.03 to 0.08 MPa/s.  相似文献   

3.
Since 2003, the National Fuel Cell Research Center at the University of California, Irvine (UCI) has operated the first U.S. publicly accessible hydrogen refueling station (HRS). During this period, the UCI HRS supported all manufacturers in the early, pre-commercialization years of the fuel cell electric vehicle (FCEV). This paper describes and analyzes the performance of the UCI HRS during the first five years of FCEV commercialization, over which time the station has dispensed the most hydrogen daily in the California network. The station performance is compared to aggregate data published by NREL for all U.S. HRSs. Using the Hydrogen Delivery Scenario Analysis Model, typical daily refueling profiles are analyzed to determine the effect on HRS design. The results show different daily refueling profiles could substantially affect HRS design and ultimately the cost of hydrogen. While technical issues have been reduced, the compressor, dispenser, and fueling rate are areas for improvement.  相似文献   

4.
Fuel cell electric vehicles (FCEVs) have now entered the market as zero-emission vehicles. Original equipment manufacturers such as Toyota, Honda, and Hyundai have released commercial cars in parallel with efforts focusing on the development of hydrogen refueling infrastructure to support new FCEV fleets. Persistent challenges for FCEVs include high initial vehicle cost and the availability of hydrogen stations to support FCEV fleets. This study sheds light on the factors that drive manufacturing competitiveness of the principal systems in hydrogen refueling stations, including compressors, storage tanks, precoolers, and dispensers. To explore major cost drivers and investigate possible cost reduction areas, bottom-up manufacturing cost models were developed for these systems. Results from these manufacturing cost models show there is substantial room for cost reductions through economies of scale, as fixed costs can be spread over more units. Results also show that purchasing larger quantities of commodity and purchased parts can drive significant cost reductions. Intuitively, these cost reductions will be reflected in lower hydrogen fuel prices. A simple cost analysis shows there is some room for cost reduction in the manufacturing cost of the hydrogen refueling station systems, which could reach 35% or more when achieving production rates of more than 100 units per year. We estimated the potential cost reduction in hydrogen compression, storage and dispensing as a result of capital cost reduction to reach 5% or more when hydrogen refueling station systems are produced at scale.  相似文献   

5.
Hydrogen as compressed gas is a promising option for zero-emission fuel cell vehicle. The fast and efficient refueling of high pressure hydrogen can provide a convenient platform for fuel cell vehicles to compete with conventional gasoline vehicles. This paper reports the finding of adiabatic simulation of the refueling process for Type IV tank at nominal working pressure of 70 MPa with considering the station refueling conditions. The overall heat transfer involved in refueling process was investigated by heat capacity model based on MC method defined by SAE J2601. The simulation results are validated against experimental data of European Commission's Gas Tank Testing Facility at Joint Research Centre (GasTef JRC), Netherlands. The results confirmed that end temperature and state of charge significantly depends on refueling parameters mainly supply hydrogen temperature and filling rate.  相似文献   

6.
This paper examines the deviation of refueling a hydrogen fuel cell vehicle with limited opportunity provided by the 68 proposed stations in California. A refueling trip is inserted to reported travel patterns in early hydrogen adoption community clusters and the best and worst case insertions are analyzed. Based on these results, the 68 refueling stations provide an average of 2.5 and 9.6 min deviation for the best and the worst cases. These numbers are comparable to currently observed gasoline station deviation, and we conclude that these stations provide sufficient accessibility to residents in the target areas.  相似文献   

7.
Hydrogen refueling stations require high capital investment, with compression and storage comprising more than half of the installed cost of refueling equipment. Refueling station configurations and operation strategies can reduce capital investment while improving equipment utilization. Argonne National Laboratory developed a refueling model to evaluate the impact of various refueling compression and storage configurations and tube trailer operating strategies on the cost of hydrogen refueling. The modeling results revealed that a number of strategies can be employed to reduce fueling costs. Proper sizing of the high-pressure buffer storage reduces the compression requirement considerably, thus reducing refueling costs. Employing a tube trailer to initially fill the vehicle's tank also reduces the compression and storage requirements, further reducing refueling costs. Reducing the cut-off pressure of the tube trailer for initial vehicle fills can also significantly reduce the refueling costs. Finally, increasing the trailer's return pressure can cut refueling costs, especially for delivery distances less than 100 km, and in early markets, when refueling stations will be grossly underutilized.  相似文献   

8.
The literature lacks a systematic analysis of HRS equipment and operating standards. Researchers, policymakers, and HRS operators could find this information relevant for planning the network's future expansion. This study is intended to address this information need by providing a comprehensive strategic overview of the regulations currently in place for the construction and maintenance of hydrogen fueling stations.A quick introduction to fundamental hydrogen precautions and hydrogen design is offered. The paper, therefore, provides a quick overview of hydrogen's safety to emphasize HRS standards, rules, and regulations. Both gaseous and liquid safety issues are detailed, including possible threats and installation and operating expertise.After the safety evaluation, layouts, equipment, and operating strategies for HRSs are presented, followed by a review of in-force regulations: internationally, by presenting ISO, IEC, and SAE standards, and Europeanly, by reviewing the CEN/CENELEC standards. A brief and concise analysis of Italy's HRS regulations is conducted, with the goal of identifying potential insights for strategic development and more convenient technology deployment.  相似文献   

9.
Dispenser allocation to hydrogen refueling stations aims at minimizing the number of dispensers while ensuring satisfactory performance of vehicle queues during the peak hour of a peak day. A queuing model is developed in this study to evaluate the queuing performance at such stations by incorporating the statistical and thermodynamic characteristics of refueling. An optimization framework is proposed to determine the minimal number of dispensers required to meet the upper limits imposed on two important performance measures: mean waiting time and mean queue length. Reasonable upper limits are provided for 70 MPa stations according to the effects of dispenser allocation and station capacity on queuing performance. Server (dispenser nozzle) utilization under the optimal dispenser allocation generally increases with an increase in station size and tends to exceed 50% for large stations. The proposed approach can offer significant performance improvements for small stations and considerable savings in the number of dispensers for large ones.  相似文献   

10.
Development of efficient hydrogen refueling station (HRS) is highly desirable to reduce the hydrogen cost and hence the life cycle expense of fuel cell vehicles (FCVs), which is hindering the large scale application of hydrogen mobility. In this work, we demonstrate the optimization of gaseous HRS process and control method to perform fast and efficient refueling, with reduced energy consumption and increased daily fueling capacity. The HRS was modeled with thermodynamics using a numerical integration method and the accuracy for hydrogen refueling simulation was confirmed by experimental data, showing only 2 °C of temperature rise deviation. The refueling protocols for heavy duty FCVs were first optimized, demonstrating an average fueling rate of 2 kg/min and pre-cooling demand of less than 7 kW for 35 MPa type III tanks. Fast refueling of type IV tanks results in more significant temperature rise, and the required pre-cooling temperature is lowered by 20 K to achieve comparable fueling rate. The station process was also optimized to improve the daily fueling capacity. It is revealed that the hydrogen storage amount is cost-effective to be 25–30% that of the nominal daily refueling capacity, to enhance the refueling performance at peak time and minimize the start and stop cycles of compressor. A novel control method for cascade replenishment was developed by switching among the three banks in the order of decreased pressure, and results show that the daily refueling capacity of HRS is increased by 5%. Therefore, the refueling and station process optimization is effective to promote the efficiency of gaseous HRS.  相似文献   

11.
Hydrogen used in proton exchange membrane-based fuel cell applications is subject to very high quality requirements. While the influences of contaminations in hydrogen on long-term stability have been intensively studied, the purity of hydrogen for mobile applications provided at hydrogen refueling stations (HRS) is rarely analyzed. Hence, in this study, we present sampling of hydrogen at HRS with a specially designed mobile tank for up to 70 MPa. These samples are precisely analyzed with a sophisticated ion molecule reaction mass spectrometer (IMR-MS), able to determine concentrations of contaminants down to the ppb-level. Sampling and analysis of hydrogen at an HRS supplied by electrolysis revealed a high purity, but likewise considerable contaminations above the threshold of the international standard ISO 14687:2019. In this study, a state-of-the-art analysis coupled with a developed methodology for fuel cell electric vehicle-independent sampling of hydrogen with a mobile tank system is demonstrated and applied for comprehensive studies of hydrogen purity.  相似文献   

12.
Fuel cell hybrid vehicles' sustained development and commercialization are contingent on the reliability and durability of the fuel cell engines. In August 2008, official trial of the three proton-exchange membrane (PEM) fuel cell hybrid city buses commenced in a commercial-operation urban-route in Beijing for one year. In this paper, data from the performance analysis of the automotive fuel cells used in those city buses are presented and analyzed. The durability and reliability of the fuel cell engines under realistic conditions were evaluated by analyzing the standard deviation of the single-cell fuel cell voltages and by estimating the voltage vs. current characteristics obtained using the recursive least squares fitting method. After studying the degradation status by analyzing fitted results from the measured data, it is concluded that the fuel cell engines' performance meets the standard imposed by the driving conditions of the Beijing urban-routes, but that their performance degradation necessitates maintenance in order to ensure normal operation.  相似文献   

13.
This paper presents the economic assessment of novel refueling stations, in which through advanced and high efficiency technologies, the polygeneration of more energy services like hydrogen, electricity and heat is carried out on-site.The architecture of these polygeneration plants is realized with a modular structure, organized in more sections.The primary energy source is ammonia that represents an interesting fuel for producing more energy streams. The ammonia feeds directly the SOFC that is able to co-generate simultaneously electricity and hydrogen by coupling a high efficiency energy system with hydrogen chemical storage.Two system configurations have been proposed considering different design concepts: in the first case (Concept_1) the plant is sized for producing 100 kg/day of hydrogen and the power section is sized also for self-sustaining the plant electric power consumption, while in the second one (Concept_2) the plant is sized for producing 100 kg/day of hydrogen and the power section is sized for self-sustaining the plant electric power consumption and for generating 50 kW for the DC fast charging.The economic analysis has been carried out in the current and target scenarios, by evaluating, the levelized cost of hydrogen (LCOH), the levelized cost of electricity (LCOE), the Profitability Index (PI), Internal rate of Return (IRR) and the Discounted Payback Period (DPP).Results have highlighted that the values of the LCOH, for the proposed configurations and economic scenarios, are in the range 6–10 €/kg and the values of the LCOE range from 0.447 €/kWh to 0.242 €/kWh.In terms of PI and IRR, the best performance is achieved in the Concept_1 for the current scenario (1.89 and 8.0%, respectively). On the contrary, in the target scenario, thanks to a drastic costs reduction the co-production of hydrogen and electricity as useful outputs, becomes the best choice from all economic indexes and parameters considered.  相似文献   

14.
Piston ring sealing and valve design play an important role in high-pressure oil-free reciprocating compressors for hydrogen refueling stations. The severe non-uniformity of the pressure distribution was suggested to be the root cause of the premature failure of the sealing rings, and therefore a mathematical model was established to simulate the unsteady flow within the gaps of piston rings, based on which the pressure distribution was obtained and the mechanism of the non-uniform abrasion of the rings was disclosed. The method to equalize the pressure difference through each ring was proposed by re-distributing the cut size of each ring, and it was validated experimentally. Aiming at the problem that the self-acting valves in hydrogen compressors could be easily destroyed by severe impact, this paper investigated the motion and impact of valves theoretically and experimentally, based on which the methodology was explored to design the parameters of valves for hydrogen compressors.  相似文献   

15.
Fuel cell vehicles are a possible alternative for allowing a replacement of fossil-fuel based transportation. Thereby, this work's methodology proposes a Hydrogen Refueling Station (HRS) design powered by a photovoltaic plant for supplying the taxi fleet in a Brazilian city considering different scenarios and assuming that hydrogen-powered vehicles replace the current fleet. Results show that in order to supply 100% of the taxi fleet with hydrogen, 185.4 kgH2/day are necessary, while only 19.8 kgH2/day are enough to supply just 10% of it. Results also reveal slight variations in energy intensity. Hydrogen production costs are inversely proportional to the HRS's production capacity. Hydrogen costs about US$ 8.96/kg for larger HRSs and US$ 13.55/kg for smaller ones. Finally, the proposed system is an attractive alternative in the future nationwide, due to the fact that the cost of electricity has been escalating year after year above inflation rates.  相似文献   

16.
We have demonstrated a hydrogen (H2) refueling solution capable of delivering precooled, compressed gaseous hydrogen for heavy duty vehicle (HDV) refueling applications by refueling transit buses over a three-month period under real-world conditions. The system uses a submerged pump to deliver pressurized liquid H2 from a cryogenic storage tank to a dispensing control loop that vaporizes the liquid and adjusts the pressure and temperature of the resulting gas to enable refueling at 35 MPa and temperatures as low as −40 °C, consistent with the SAE J2601 standard. Using our full-scale mobile refueler, we completed 118 individual bus filling events using 13 different vehicles, involving a total of 3,700 kg of H2 dispensed. We report filling statistics from the entire campaign, details on individual fills (including fill times, final state of charge, benefits of pre-cooled fills, and back-to-back filling capabilities), and discuss transit agency feedback on technology performance. In our final test, the system successfully completed an endurance test using a single dispenser involving 52 consecutive individual fills over an 11.5-h period, dispensing 1,322 kg of H2 with an average fill rate of 3.4 kg/min and peak rate of 7.1 kg/min, and reaching an average SOC of 97.6% across all fills.  相似文献   

17.
A well-designed control system with a high utilization ratio of hydrogen and a fast filling speed are two critical objectives to ensure the reduction of cost and time required in the refueling process. In this paper, the popular three-stage refueling process is modeled with the aim to address both objectives. Using the real gas law of hydrogen, the utilization ratio of hydrogen filling is analyzed and the filling flowrate and time of each stage are evaluated. A multi-objective iterative optimization model is established and an optimization algorithm for the filling process is proposed to achieve both fast refueling and high utilization. Numerical results can be applied to the optimization of an actual hydrogen filling process. Besides, the tests show that an optimized control method can significantly improve the utilization ratio and allow refueling in a widely acceptable time.  相似文献   

18.
To place hydrogen energy usage into proper perspective, International Center for Hydrogen Energy Technologies (ICHET) has been implementing measures to demonstrate potential benefits of the “hydrogen and fuel cell systems” in developing countries. Demonstration of technologies is the most important aspect of ICHET vision for the formation of an industry in the developing world. ICHET has embarked on a series of educational and laboratory activities designed to increase the knowledge and awareness of students and advanced researchers concerning hydrogen energy technologies. The state of the art fuel cell laboratory is available for joint technology development and demonstration activities. Internship activities facilitate knowledge transfer, exchange of information at regional, national and international levels and involve academics, researchers, experts and service providers. Collaboration is a key part of the organizational strategy for joint projects, funding and trainings in the field of hydrogen and fuel cells.  相似文献   

19.
Last three decades, costumers and manufacturers of automotive sector have been influenced positively by Hydrogen and fuel cells (FCs). The main goal of automakers can be pointed as minimizing the fuel consumption and exhaust emissions while improving the range limits, energy efficiency and latest technology adaptation. Therewithal, electric assisted propulsion systems added to vehicles and are called as electric vehicles (EVs). For that matter, Battery Electric Vehicles (BEVs) and hydrogen Fuel Cell Electric Vehicles (FCEVs) have become the focus of researchers and producers. In this mini foreseen review, overview of the next quarter century vision of FCEVs are expressed and discussed by the helped of previous researches and with future forecast reports. The introduction part is summarized the general approach and future expectations of FCs in detailed. Technical overview is represented for FCs and FCEVs in terms of current state of technology to foreseen expectancy. Infrastructure analysis and future aspects overview part is also discussed for sector's perspective on FCEVs. The near future perspective of the FCEVs, which is seen as the next step in EVs, is discussed in detail in the next quarter century vision. Authors concluded that, between the 2030s-2050s, hydrogen FCEVs will continue their rising demand scale under the circumstances of decreasing expensive technology; enhanced energy optimization; extended range limits and increasing hydrogen refueling stations.  相似文献   

20.
Hydrogen refueling is an essential infrastructure for fuel cell vehicles, and currently, it appears to be a critical service needed to initiate the highly anticipated hydrogen economy in China. A practical selecting procedure of adding hydrogen refueling service to existing natural gas (NG) stations is proposed in this study. A case study in Wuhan, China, is established to assess the feasibility and future planning. The demand for hydrogen fuel and initial supply chain of hydrogen in Wuhan are estimated based on the deployment objective of fuel cell buses. The existing NG stations are evaluated based on 300 kg/day to determine whether they meet the hydrogen safety requirement using Google map or field investigation. The safety space requirement of the hydrogen refueling area on existing NG station is determined as 25.9 × 27.1 m2. The optimal hydrogen refueling plan for fuel cell buses is calculated with multi‐objective analysis in economic, environmental, and safety aspects from the view of the hydrogen refueling supply chain. It is shown that adding hydrogen refueling stations to existing NG stations is feasible in technology, economics, regulation, and operation considerations. This study provides guidelines for building the hydrogen infrastructure for fuel cell buses at their early stage of commercial operation.  相似文献   