首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了甘蓝和蘑菇中甲氨基阿维菌素苯甲酸盐的固相萃取-高效液相色谱荧光分析方法。蔬菜样品用乙酸乙酯提取,提取液旋转浓缩近干后用少量乙酸乙酯溶解,再经PRS固相萃取(SPE)柱净化,洗脱液经氮气吹干后用氮甲基咪唑和三氟乙酸酐衍生,衍生物用高效液相色谱分析,采用外标法定量。在添加浓度1.0~20.0 μg/kg范围内,平均添加回收率为78.6%~84.9%,日内相对标准偏差(RSD)为2.7%~6.0%,日间RSD为3.1%~8.9%,检出限为0.10 μg/kg。甲氨基阿维菌素苯甲酸盐衍生物在0.002~0.10 mg/L范围内呈良好的线性关系,相关系数为0.9999。  相似文献   

2.
Currently, gas chromatography (GC) is the most widely used analytical technique to verify the quality of biodiesel in relation to its glyceride and fatty acid methyl ester (FAME) contents, even though its use has some disadvantages, such as damage to the injector and column caused by the presence of trace levels of triacylglycerols in biodiesel, which means the column has to be replaced every 3 months; the need for the sample to be derivatized, which, while improving chromatographic separation, also increases analysis time; and the use of several imported standard solutions. The main aim of this work was to use high-performance liquid chromatography with refractive index detection (HPLC-RI) to simultaneously quantify the glyceride (mono, di, and triacylglycerol) and FAME contents of biodiesel. The proposed method showed satisfactory results when compared with those obtained by the reference method (GC), particularly when these results were within the working ranges of the reference method. The proposed method using HPLC-RI is therefore promising and could potentially be used instead of the reference method, since the results it yielded were statistically equivalent, with 95% confidence, to the results obtained by the reference method (GC) for the nine samples of commercial biodiesel analyzed in this study.  相似文献   

3.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

4.
超高效液相色谱法测定护手霜中5种不同的雌激素   总被引:5,自引:0,他引:5  
建立了超声波萃取.超高效液相色谱快速测定护手霜中5种雌激素(雌酮,雌二醇,苯甲酸雌二醇,美雌醇,炔雌醇环戊醚)的分析方法,研究了萃取溶剂、萃取时间对萃取效率的影响,确立了流动相流速及色谱柱柱温等检测条件.化妆品以乙腈和水(20:80,V:V)为提取溶剂进行超声波萃取后用C18色谱柱分离,乙腈和水溶液为流动相,梯度洗脱,10min内完成5种雌激素的分离与检测.方法的检出限为0.016—0.031μg/mL,相对标准偏差均小于5.0%m=3),5种雌激素的工作曲线的相关系数均高于0.992.化妆品的加标回收率在85%~95%之间.方法简单快速、灵敏度高、分离效果好,满足化妆品中雌激素分析的需要.  相似文献   

5.
A novel method was developed for the determination of amiodarone and desethylamiodarone by high-performance liquid chromatography (HPLC) coupled with chemiluminescent (CL) detection. The procedure is based on the post-column photolysis of the analytes into photoproducts which are active in the tris(2,2′-bipyridyl)ruthenium(III) [Ru(bpy)33+] CL system. Ru(bpy)33+ was on-line generated by photo-oxidation of the Ru(II) complex in the presence of peroxydisulfate. The separation was carried out on a Mediterranea C18 column with isocratic elution using a mixture of methanol and 0.017 mol L−1 ammonium sulfate buffer of pH 6.8. Under the optimum conditions, analytical curves, based on standard solutions, were linear over the range 0.1-50 μg mL−1 for amiodarone and 0.5-25 μg mL−1 for desethylamiodarone. The detection limits of amiodarone and desethylamiodarone were 0.02 and 0.11 μg mL−1, respectively. Intra- and inter-day precision values of 0.9% relative standard deviation (R.S.D.) (n = 10) and 1.6% R.S.D. (n = 15), respectively, were obtained. The method was applied successfully to the determination of these compounds in serum and pharmaceutical formulations.  相似文献   

6.
A simple and rapid detection method of oligosaccharides using high-performance liquid chromatography with a charged aerosol detection (HPLC-CAD) was studied. The direct detection of a sialylglycopeptide (SGP) derived from egg yolk was accomplished by HPLC-CAD using an amido-silica column, and its limit of detection was 0.40 pmol [signal-to-noise ratio (S/N) = 3]. The sensitivity of this method was lower than that of the fluorescence detection; however, the method showed approximately 5 times higher sensitivity than that using the conventional UV absorbance detection. Furthermore, this method was used for the analysis of the acid hydrolysis products of SGP. Monosialo- and asialo-oligosaccharides as well as free sialic acid were detected without using fluorescent derivatization. These results indicate that the present method is a new tool for the analysis of oligosaccharides.  相似文献   

7.
A simple and rapid high-performance liquid chromatographic (HPLC) method with ultraviolet detection has been developed and validated for the simultaneous determination of rifampicin and sulbactam in mouse plasma. Plasma samples were deproteinized with acetonitrile and separated by HPLC on a RP-18 (125 x 4 mm, 5 microm) column and gradient elution with potassium dihydrogen phosphate solution (pH 4.5; 50 mm) and acetonitrile at a flow-rate of 1.0 mL/min. Rifampicin and sulbactam were monitored at 230 nm and confirmed by means of their UV spectra using a diode-array detector. The method was linear at plasma levels from 1 to 100 microg/mL for rifampicin and from 5 to 200 microg/mL for sulbactam. The limits of quantification were 0.6 microg/mL for rifampicin and 4.2 microg/mL for sulbactam. The intra- and inter-day precisions of the method (RSD) were lower than 5% for both compounds. Average recoveries of rifampicin and sulbactam from mice plasma were 98.2 and 89.3%, respectively. The developed method was successfully applied to the determination of the pharmacokinetic profile of both compounds in mice.  相似文献   

8.
赵燕燕  刘丽艳  韩媛媛  白洁  杜光玲  高茜 《色谱》2011,29(2):146-151
采用高效液相色谱-荧光检测法同时测定了大鼠不同脑区中的左旋多巴、去甲肾上腺素、肾上腺素、多巴胺、二羟基苯乙酸、5-羟色胺、5-羟基吲哚乙酸及高香草酸8种单胺类神经递质的含量。样品经组织裂解液(0.60 mol/L高氯酸、0.50 mmol/L Na2EDTA、0.1 g/L L-半胱氨酸的混合水溶液)处理后,冷冻离心得到上清液;上清液中加入高氯酸沉淀剂(1.20 mol/L K2HPO4、2.00 mmol/L Na2EDTA的混合水溶液)处理后,冷冻离心、过滤。在该优化的色谱条件下,8种单胺类神经递质在1.25~5000 μg/L范围内线性关系良好(r>0.9999),最低检出限在0.20~5.00 μg/L之间,平均回收率在94.83%~99.19%之间,相对标准偏差在0.08%~2.51%之间。该方法具有操作简便、快捷、回收率高、检出限低、分离度好、结果准确可靠等优点,可以用于体内8种单胺类神经递质的同时检测与分析。  相似文献   

9.
An innovative two-dimensional high-performance liquid chromatography system was developed for the simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero. A C8 reversed-phase chromatographic column with ultraviolet detection was used as the first dimension for the determination of aspartame, and a ligand-exchange chromatographic column with on-line postcolumn derivation fluorescence detection was employed as the second dimension for the analysis of amino acid enantiomers. The fluorimetric derivative reagent of amino acid enantiomers was o-phthaldialdehyde. The hydrolysis of aspartame in Coca-Cola Zero was induced by electric-heating or microwave heating. Aspartame was quantified by the matrix matched external standard calibration curve with a linear concentration range of 0-50 μg mL(-1) (r(2)=0.9984). The limit of detection (LOD) and the limit of quantification (LOQ) were 1.3 μg mL(-1) and 4.3 μg mL(-1), respectively. The amino acid enantiomers was analyzed by the matrix matched internal standard calibration method (D-leucine as the internal standard) with a linear concentration range of 0-10 μg mL(-1) (r(2)=0.9988-0.9997). The LODs and LOQs for L- and D-aspartic acid and L- and D-phenylalanine were 0.16-0.17 μg mL(-1) and 0.52-0.55 μg mL(-1), respectively, that was 12-13 times more sensitive than ultraviolet detection. The overall analysis accuracy for aspartame and amino acid enantiomers was 90.2-99.2% and 90.4-96.2%, respectively. The overall analysis precision for aspartame and amino acid enantiomers was 0.1-1.7% and 0.5-6.7%, respectively. Generally, the extent of aspartame hydrolysis increases with the increase of electro-thermal temperature, microwave power, and the duration of hydrolysis time. D-aspartic acid and D-phenylalanine can be observed with the electro-thermal racemization at the hydrolysis temperature 120°C for 1 day and only D-aspartic acid can be observed at the hydrolysis temperature 90°C for 2 and 3 days. For the microwave induced hydrolysis, only L-aspartic acid was detected at the power 560 W for 1 min and 320 W for 3 min.  相似文献   

10.
唐秀芳  甄乾娜  樊子勉  冯成亚  丁敏 《色谱》2012,30(6):613-617
建立了一种柱前衍生高效液相色谱-荧光检测法用于测定血浆中同型半胱氨酸(Hcy)。使用三(2-羧乙基)膦盐酸盐(TCEP)为还原剂,N-(1-芘)马来酰亚胺(NPM)为衍生剂进行样品预处理,Agilent Hypersil C-18柱(250 mm×4.0 mm, 5 μm)进行分离,流动相为15 mmol/L醋酸钠-乙腈-混合酸(300 mL水中含1 mL醋酸和1 mL磷酸)混合溶液,采用梯度洗脱,荧光检测激发波长为330 nm,发射波长为380 nm。Hcy的回收率为(102.08±4.94)%。线性范围为0.500~100 μmol/L,检出限(以信噪比为3计)为0.016 μmol/L。日内与日间相对标准偏差均小于5%。利用该方法对7例高血压患者和7例健康志愿者的血浆进行了测定,结果表明两组间的Hcy含量存在显著的差异(p<0.05)。本方法简单、快速、灵敏、特异,适用于血浆Hcy的临床定量测定。  相似文献   

11.
Summary The present paper describes the development of a method for the differentiation of hydroxycinnamic acid derivatives by HPLC with photodiode-array detection. Furthermore spectral data of the compounds under investigation are given. Whereas p-coumaric acid derivatives are distinguishable from caffeic and ferulic acid derivatives by the positions of their spectrum maxima and their convexity interval value, it is not possible to distinguish between caffeic and ferulic acid derivatives because of overlapping spectrum maxima and convexity interval values.  相似文献   

12.
Summary A new sensitive HPLC-FLD method has been developed and validated for the determination of cisapride in human plasma for a bioequivalence study. A gradient method was used to remove late-eluting plasma components of no interest. The separation was performed on a Li-ChroCART 250-4 Purospher RP-18 (5 μm particle) analytical column fitted with a LiChroCART 4-4 Purospher RP-18 endcapped (5 μm particle) guard column. The excitation and emission wavelengths were 295 and 350 nm during fluorescence detection. The calibration plot was linear in the range of 5–200 ng mL−1. A demethoxy analogue of cisapride was used as internal standard.  相似文献   

13.
Cefpiramide is frequently used to treat biliary infections. However, no bioanalytical method has been validated to quantitate cefpiramide in human samples, particularly in bile. Therefore, this study was conducted to develop a simple, selective and validated high-performance liquid chromatographic method to determine cefpiramide in human plasma and bile. A protein precipitation procedure was used to extract cefpiramide and cefoperazone (internal standard, IS) from 200 μl of plasma and bile. Utilizing a Capcell Pak C18 column (4.6 × 250 mm), cefpiramide and IS were separated using the timed-gradient mobile phase consisting of 0.1 m sodium acetate (pH 5.2) and acetonitrile at a flow rate of 1 ml/min with photodiode array detector (wavelength set at 273 nm). The calibration curves showed linearity at concentrations ranging from 1 to 150 μg/ml in both plasma and bile (r2 > 0.999). The within- and between-run coefficients of variation (CVs) for plasma samples were 0.570–4.43 and 1.10–2.76%, respectively; for bile samples, the within- and between-day precision (CV) was 0.814–6.34 and 2.05–4.00%, respectively. Our newly developed bioanalytical method was successfully employed to quantify cefpiramide concentrations in both plasma and bile at multiple time points in patients with acute cholangitis.  相似文献   

14.
石芳  寿旦  金米聪  王宏伟  陈旭光  朱岩 《色谱》2022,40(2):139-147
随着麻醉剂广泛用于渔业生产过程和水产品运输等领域,建立水产品中麻醉剂残留的检测方法具有重要意义.由于水产品基质复杂且麻醉剂残留水平低,因此需要合适的前处理方法以提高检测灵敏度.该研究基于分散固相萃取-高效液相色谱,建立了一种同时检测水产品中普鲁卡因、丁氧卡因、三卡因、丁香酚、甲基丁香酚、异丁香酚、甲基异丁香酚7种麻醉剂...  相似文献   

15.
The isomerism of glucaric acids and the complexity of the composition of Leonurus japonicus Houtt. increased the difficulty of the separation of glucaric acids from the herb. In the present study, three glucaric acids were isolated from Leonurus japonicus Houtt. by using high-speed countercurrent chromatography combined with semi-preparative high-performance liquid chromatography. Cation exchange resin chromatography was applied to remove the alkaloids and enrich the glucaric acid fractions. Preliminary separation of the glucaric acid extract by high-speed countercurrent chromatography was carried out at 45℃ by using an optimized solvent system of ethyl acetate/n-butanol/formic acid/water (1:1:0.01:2, v/v/v/v) with satisfied stationary phase retention and separation factor. The semi-preparative high-performance liquid chromatography was used for further separation and purification of the target fractions, and three monomeric compounds were obtained with purities of 90.0, 91.0, and 95.3%. UV spectroscopy, NMR spectroscopy, and mass spectrometry were employed to identify their structures, which were assigned as 2-syringyl glucaric acid, 2,4-disyringyl glucaric acid, and 3,4-disyringyl glucaric acid, respectively, and 2,4-disyringyl glucaric acid was reported for the first time.  相似文献   

16.
Accumulating evidence has suggested the potential health-promoting effects of 5-hydroxy polymethoxyflavones (5-OH-PMFs) naturally existing in citrus genus. However, research efforts are hampered by the lack of reliable and sensitive methods for their determination in plant materials and biological samples. Using reversed-phase high performance liquid chromatography (HPLC) equipped with electrochemical (EC) detection, we have developed a fast and highly sensitive method for quantification of four 5-OH-PMFs, namely 5-hydroxy-6,7,8,3′,4′-pentamethoxyflavone, 5-hydroxy-3,6,7,8,3′,4′-hexamethoxyflavone, 5-hydroxy-6,7,4′-trimethoxyflavone, and 5-hydroxy-6,7,8,4′-tetramethoxyflavone. The method was fully validated in terms of linearity, accuracy and precision. The limit of detection (LOD) was determined as being between 0.65 and 1.8 ng/mL (ppb), demonstrating an over 160 times higher sensitivity in comparison with the previously reported method using UV detection. The recovery rate of the method was between 96.17% and 110.82%, and the precision for the retention times and peak areas was all below 13%. The method was successfully used to quantify 5-OH-PMFs with a wide range of abundance in the citrus products and preparations, such as orange juice, citrus peel, and dried tangerine peel. The quantification method for 5-OH-PMFs developed herein could be useful for the nutritional and pharmacological studies of these compounds in future.  相似文献   

17.
A method was developed for the determination of polyamines (PA) by high-performance liquid chromatography with chemiluminescence detection. It is based on the unsaturated complex of PA with Cu(II) which had a strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The separation of PA was carried out on a reveres phase C18 column using methanol/water (25/75, v/v) as a mobile phase. The method was applied to the analysis of putrescine and the total amount of spermine and spermidine in apple leaves and strawberry fruit. The results indicated that the method is practical and useful.  相似文献   

18.
鸡肉中11种喹诺酮类药物多残留的高效液相色谱检测   总被引:4,自引:0,他引:4  
林保银 《色谱》2009,27(2):206-210
建立了用荧光检测器同时测定11种喹诺酮类药物(包括诺氟沙星、培氟沙星、环丙沙星、恩诺沙星、氧氟沙星、达氟沙星、洛美沙星、二氟沙星、沙拉沙星、恶喹酸和氟甲喹)在鸡肉中的多残留的高效液相色谱检测方法。鸡肉样品用10%三氯乙酸-乙腈(体积比为7∶3)提取两次并稀释,随后用反相固相萃取柱净化。采用Hypersil BDS-C18色谱柱分离,以乙腈和水为流动相梯度洗脱,荧光检测器用程序编程检测波长检测。11种喹诺酮类药物标准曲线的线性范围为5~1200 μg/L,相关系数大于0.998。在高、中、低三个添加水平下的回收率为56%~119%,批内相对标准偏差为0.4%~16.1%,批间相对标准偏差为1.4%~23.0%。检出限和定量限分别为1~23 μg/kg和4~40 μg/kg。该方法快速、灵敏,达到了兽药残留检测的要求。  相似文献   

19.
We have developed a reversed-phase high-performance liquid chromatography-pulsed amperometric detection (RP-HPLC-PAD) method for the detection of albiflorin and paeoniflorin in Paeoniae Radix and Wu-ji-san. Albiflorin and paeoniflorin were completely separated using 10% acetonitrile in 5 mM sodium phosphate buffer (pH 3.0) as an eluent and detected by PAD under alkaline conditions after using a post-column delivery system. The limit of detection (S/N = 3) and the limit of quantification (S/N = 10) were 0.10 and 0.35 ng for albiflorin, and 0.20 and 0.50 ng for paeoniflorin, respectively. The coefficients of linear regression were 0.9995 and 0.9999 for concentrations between 0.035 and 100 μg/mL. The intra- and inter-day precision (RSDs) was less than 3.56% in Paeoniae Radix and Wu-ji-san. The average recoveries from Paeoniae Radix and Wu-ji-san were 99.01–100.94% and 99.46–100.64%. This method shows higher selectivity than HPLC–UV method for analyzing albiflorin and paeoniflorin in Chinese medicinal preparation.  相似文献   

20.
With polyamide( PA)as an efficient sorbent for solid phase extraction( SPE)of Sudan dyes II,III and Red 7B from saffron and urine,their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water( 1:9,v/v,pH 7)as the washing solvent and 3 mL tetrahydrofu-ran for elution. Good clean-up and high( above 90%)recoveries were observed for all the analytes. The opti-mized mobile phase composition for HPLC analysis of these compounds was methanol-water( 70:30,v/v). The SPE parameters,such as the maximum loading capacity and breakthrough volume,were also determined for each analyte. The limits of detection( LODs),limits of quantification( LOQs),linear ranges and recoveries for the analytes were 4. 6-6. 6 μg/L,13. 0-19. 8 μg/L,13. 0-5 000 μg/L( r2> 0. 99)and 92. 5% -113. 4%,respec-tively. The precisions( RSDs)of the overall analytical procedure,estimated by five replicate measurements for Sudan II,III and Red 7B in saffron and urine samples were 2. 3%,1. 8% and 3. 6%,respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine sam-ples with HPLC coupled with UV detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号