首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 46 毫秒
1.
多级厌氧缺氧好氧活性污泥法是由若干个厌氧缺氧好氧串联的形式组成,利用分段厌氧进水,形成多级厌氧-缺氧和多级缺氧-好氧同时交替运行,具有反硝化除磷和高效脱氮功能,采用无内回流技术,通过调节流量比值实现强化除磷与强化脱氮的控制目标,并具有污泥浓度高、抗冲击能力强、污泥减量、优化利用碳源、节省运行能耗和曝气量等特点,是节能型高效除磷脱氮新工艺,为城市污水高效除磷脱氮提供新的思路及途径。  相似文献   

2.
生物脱氮除磷工艺好氧区硝化功能的强化试验   总被引:5,自引:0,他引:5  
在活性污泥法脱氮除磷工艺系统的好氧段投放高硬度聚乙烯悬浮小球作为生物载体,可以强化系统的硝肥功能,提高处理系统的脱氮除磷效率,同时避免产生填料间污泥结团。经两套试验装置的5种工况条件下平行对照试验结果表明:好氧区全池投放聚乙烯悬浮小球,装填密度在10% ̄15%,TKN去除率达98.2%,TN去除率达到86%,TP去除率达到91%。  相似文献   

3.
厌氧-好氧-缺氧短程硝化同步反硝化除磷工艺研究   总被引:4,自引:0,他引:4  
构建了主要由厌氧-好氧-缺氧构成的短程硝化同步反硝化除磷工艺,并在常温条件下用于生活污水的处理.研究发现,通过调节反应器内好氧区的pH(8.2~8.7)和溶解氧(DO为3~5mg·L-1)能实现该工艺的快速启动,在好氧区内实现亚硝酸盐的累积.在稳定运行期内,DO是影响短程硝化的主要影响因素,好氧1区DO控制在1.5~2.0mg·L-1,好氧2区DO控制在0.5~1.0mg·L-1,好氧区内亚硝酸盐氮累积浓度稳定在5~10mg·L-1,氨氮去除率达到90%以上.各反应单元内碳源、硝酸盐和亚硝酸盐对除磷贡献的研究表明,该工艺的缺氧段实现了在不外加碳源的情况下以亚硝酸盐和硝酸盐共同作为电子受体的反硝化除磷,反硝化除磷量占系统总除磷量的80%以上.  相似文献   

4.
针对好氧颗粒污泥颗粒化时间慢等问题,进行了同步硝化内源反硝化除磷好氧颗粒污泥常温储存及活性恢复实验研究.结果表明,好氧颗粒污泥经过60d的常温储存后,颗粒的结构基本能保持稳定,但是颗粒污泥的活性大幅度降低,污染物去除率仅有储存前的30%~40%.将常温储存的颗粒污泥接种到反应器中,经过一定的调控手段,可以在60d内恢复好氧颗粒污泥的功能及活性.此外,经过储存与恢复,好氧颗粒污泥的群落结构也发生了明显变化.大部分的微生物的相对丰度变化可逆,经过储存和恢复可以恢复至储存前的状态(包括Defluviicoccus (GAOs)和Flavobacterium (PAOs)),重构同步脱氮除磷的微生物群落结构.  相似文献   

5.
探究ABR-MBR耦合工艺在无污泥回流及在ABR各隔室接种高浓度(25g·L-1,以MLSS计)活性污泥条件下启动反硝化除磷性能的可行性以及反硝化除磷隔室内微生物群落特征.结果表明,通过逐步提升硝化液回流比(R)由0%至200%成功启动反硝化除磷性能.稳定运行过程中,系统对COD、 PO3-4-P和TN的平均去除率分别为88.28%、 54.45%和61.93%.在ABR进水容积负荷(以COD计,下同)为0.8 kg·(m3·d)-1、R为150%、 ABR和MBR的水力停留时间(HRT)分别为9h和3.3 h时,VFA平均产量为80.58mg·L-1、回流硝化液的ρ(NO-2-N)/ρ(NO-3-N)平均为1.68,PO3-4-P和TN的平均去除率分别为64.94%和62.95%,实现短程硝化和反硝化除磷耦合.批次实验证明反...  相似文献   

6.
强化生物除磷体系中的反硝化除磷   总被引:20,自引:0,他引:20  
 采用SBR反应器,研究了以硝酸盐作为电子受体的反硝化除磷过程.结果表明,反硝化聚磷菌存在于传统的强化生物除磷体系中.厌氧段磷的释放和COD的消耗成线性关系.通过厌氧/好氧交替运行方式,反硝化聚磷菌在聚磷菌中的比例从13.3%上升到69.4%.稳定运行的厌氧/缺氧SBR反应器具有良好的强化生物除磷和反硝化脱氮性能,缺氧结束时体系中磷浓度小于1mg/L,除磷效率大于89%.  相似文献   

7.
反硝化除磷作为一种新型可持续发展技术受到广泛关注. 前期在多级缺氧-好氧工艺的基础上开发了一种新型反硝化除磷工艺(DPR-MAO). 为探明内循环系统对DPR-MAO工艺脱氮除磷效能的影响,考察了不同内循环比条件下的氮磷去除效果,分析了各反应池的脱氮除磷过程以及微生物群落特征. 结果表明:当内循环比由100%提至200%时,总氮和总磷的平均去除率由76.05%和86.39%分别提至87.46%和93.42%. 通过氮磷质量平衡分析发现,提高内循环比可以使工艺表现出优良的反硝化除磷性能. 高通量测序结果表明,DPR-MAO工艺中具有反硝化除磷功能的菌属主要有Thiothrix、Dokdonella、Candidatus accumulibacter、Thauera、Comamonas、Dechloromonas和Pseudomonas. 当内循环比由100%提至200%时,具有反硝化除磷功能的菌属的相对丰度总和增加了约4倍,其中Thiothrix的相对丰度由0.36%~0.52%增至53.58%~56.64%. 研究显示,提高内循环比可以强化DPR-MAO工艺的反硝化除磷效果以及反硝化聚磷菌在微生物群落中的优势地位.   相似文献   

8.
采用反硝化除磷工艺进行生产性试验处理城市污水,结果表明:该工艺处理城市污水可以达到GB18918--2002一级标准,DPB污泥沉降性能良好,污泥浓度控制在4500-5500mg/L时确定的污泥回流比为20—35%,最佳水力停留时间为:厌氧段0.5~1h,缺氧段1.5~2h;缺氧段后面的再曝气段有利于污泥沉降并可保证除磷效果。  相似文献   

9.
采用反硝化除磷工艺进行生产性试验处理城市污水,结果表明:该工艺处理城市污水可以达到GB18918-2002一级标准,DPB污泥沉降性能良好,污泥浓度控制在4500~5500mg/L时确定的污泥回流比为20~35%,最佳水力停留时间为:厌氧段0.5~1h,缺氧段1.5~2h;缺氧段后面的再曝气段有利于污泥沉降并可保证除磷效果.  相似文献   

10.
李冬  刘博  王文琪  张杰 《环境科学》2020,41(2):867-875
以低C/N比生活污水为研究对象,接种成熟除磷颗粒污泥,通过联合调控好氧时间及曝气强度成功将其诱导成具有同步短程硝化反硝化除磷功能的颗粒污泥,并分析了此过程中系统脱氮除磷特性变化.结果表明,好氧段曝气强度为5L·(h·L)-1,在较短曝气时间下(140 min)可实现AOB的富集,但同步硝化反硝化能力难以提高;降低曝气强度为3. 5L·(h·L)-1,延长曝气时间(200 min),好氧段氮损增加.根据pH及DO曲线进一步优化曝气时长抑制NO2-向NO3-转化,优化后系统出水TP <0. 5 mg·L-1和TN <15 mg·L-1,可实现氮磷的同步去除.在系统功能由单纯的除磷向同步脱氮除磷转化的过程中,释磷量下降,PAOs在内碳源储存过程中的贡献比例有所下降,但仍占主体地位(60%).批次实验表明,颗粒中可利用NO2-为电子受体的DPAOs占绝大部分达52....  相似文献   

11.
为促进反硝化除磷与厌氧氨氧化工艺的耦合,实现污水氮、磷的同步高效去除,构建序批式反应器(Sequencing batch reactor,SBR),优化了反硝化除磷工艺实现亚硝酸盐积累的工艺参数.SBR在厌氧-缺氧-微好氧运行条件下,缺氧段投加模拟硝酸盐工业废水逐步实现了反硝化除磷过程的亚硝酸盐积累.结果表明,经过142d的培养驯化,在进水C/P比为55时,缺氧段引入NO3--N浓度为23mg/L时,亚硝酸盐积累率为51.01%,NO3--N→NO2--N转化率为40.22%,硝酸盐去除率为72.14%,PO43--P去除率最高达88.17%.出水COD浓度低于25mg/L,COD去除率维持在90%以上.微生物群落结构分析表明,拟杆菌门(Bacteroidetes)、变形菌门(Proteobacteria)、绿弯菌门(Chloroflexi)、酸杆菌门(Acidobacteria)为系统内优势菌门.通过参数优化实现了聚磷菌的驯化,Candidatus Accumulibacter为代表的反硝化聚磷菌丰度增加(累积丰度由1.49%增加到5.08%),以Candidatus Competibacter为代表的反硝化聚糖菌丰度增加更为明显(累积丰度由1.02%增加到15.49%),聚磷菌与聚糖菌的共同作用有利于实现除磷过程的亚硝酸盐累积.  相似文献   

12.
To supply the valuable operating parameters for the popular usage of the new denitrifying phosphors removal process, it is essential to study the dominant biochemical reactions and the characteristics of denitrifying phosphorus removing bacteria (DPB). Thus, parallel batch experiments using DPB sludge were carried out to assess the effect of substrates (sewage, HAc, and endogenous carbon source) on denitrifying dephosphorus removal efficiency in this study. The results showed that the initial specific phosphorus release rate increased with the high concentration of the short-chain volatile fatty acids ratio in the influent, and sufficient phosphorus was released by DPB. This improved the subsequent denitrification and phosphorus uptake efficiency. The specific endogenous denitrification mainly relies on the internal carbon source (PHB) stored by poly-P bacteria. Denitrifying phosphorus removing bacteria were very hungry when the internal PHB was consumed. Consequently, the specific endogenous denitrification rate was low and the phosphorus uptake did not happen. On the other hand, in the experiment, the denitrifying phosphorus removal performance under two temperature conditions (8–10°C and 25–26°C) was also investigated and analyzed. It was found that the lower temperature decreased the specific phosphorus release and uptake rate, but did not inhibit the denitrifying phosphorus removal completely. Therefore, the negative influence of the low temperature on the overall phosphorus removal was not significant. Translated from Acta Scientiae Circumstantiae, 2006, 26 (2): 186–192 [译自: 环境科学学报]  相似文献   

13.
亚硝酸盐为电子受体反硝化除磷工艺的可行性   总被引:26,自引:0,他引:26       下载免费PDF全文
采用序批式反应器(SBR),以亚硝酸盐为电子受体,探讨了厌氧/缺氧条件下反硝化除磷工艺的可行性,并通过间歇实验考察了亚硝酸盐浓度、进水COD浓度和进水pH值对反硝化除磷工艺的影响.结果表明,亚硝酸盐作为电子受体的同步脱氮除磷过程是完全可以实现的,控制NO2--N浓度为35±5mg/L、厌氧段进水pH值为8.0±0.1,缺氧段进水pH值为7.2±0.1、COD浓度为400mg/L时,反硝化除磷效果最佳.  相似文献   

14.
采用厌氧/缺氧/好氧和生物接触氧化反应器(A2/O-BCO)组成的反硝化除磷系统处理模拟生活污水,通过调节进水乙酸钠、丙酸钠的配比(乙酸钠:丙酸钠分别为1:0,2:1,1:1,1:2和0:1),考察了系统对有机物的去除以及同步脱氮除磷的影响,同时通过高通量测序对比了不同配比下微生物菌群结构的变化.结果表明:乙酸钠丙酸钠配比对有机物和NH4+-N的去除影响较小,对厌氧段有机物的消耗和TN的去除率以及磷的释放和吸收影响较为明显;TP去除率仅为50.3%~56.8%,需进一步优化系统的运行参数.当乙酸钠:丙酸钠=1:1时,厌氧段有机物消耗量最大,占有机物流入量的61.2%,厌氧释磷量最大(23.2mg/L)且缺氧吸磷率最高(71.4%),而TN的去除效果则随丙酸钠含量的增加而增加.高通量测序结果表明:A2/O反应器中微生物多样性降低,混合碳源污泥中微生物多样性比单一碳源更丰富;驯化后的污泥中绿弯菌(Chloroflexi)和螺旋菌(Saccharibacteria)减少,变形菌(Proteobacteria)和拟杆菌(Bacteroidetes)增加.BCO反应器中Nitrospira和Nitrosomonas总占比为2.1%~31.4%,且抑制亚硝酸盐氧化菌(NOB)的活性,有利于短程硝化的实现.  相似文献   

15.
电子受体亚硝酸氮在反硝化除磷过程中的作用   总被引:5,自引:0,他引:5  
针对先前文献提到的亚硝酸氮在反硝化除磷中存在着一定的抑制作用,以亚硝酸氮作为电子受体,对其在缺氧反硝化吸磷过程中的抑制影响进行了大量的静态烧杯试验.结果表明,在亚硝酸氮浓度大于30mg·L-1的时候,确实存在严重的抑制作用,而且该临界抑制浓度与污泥的特性和运行操作条件等因素有关;但是在亚硝酸氮浓度低于25mg·L-1的情况下不会对反硝化条件下磷的吸收产生毒害作用,相反地,它可以取代氧气、硝酸氮做为良好的电子受体用来进行缺氧段磷的生物摄取,在反硝化除磷中表现一定的积极作用.  相似文献   

16.
硝化液回流比对A2/O-BCO工艺反硝化除磷特性的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
以低C/N城市生活污水为处理对象,重点考察了硝化液回流比对A2/O - BCO(生物接触氧化)工艺脱氮除磷特性的影响.在A2/O反应池水力停留时间(HRT)为8h,污泥回流比为100% 条件下,将硝化液回流比分别设定为100%、200%、300%和400%进行试验.结果表明, 系统在A2/O中实现了反硝化除磷,具有很好的同步氮磷的去除效果,出水COD浓度均在50mg/L以下.上述不同硝化液回流比下总氮(TN)去除率分别为48.8%、66.5%、75.6%和62.5%,总磷(TP)去除率分别为86.0%、90.3%、91.0%和95.0%.在硝化液回流比为300%时,系统平均出水TN和TP浓度分别为14.96mg/L和0.49mg/L.系统反硝化除磷量随着硝化液回流比的增大略有增加,在硝化液回流比为400%时,反硝化除磷量高达磷总去除量的98%.  相似文献   

17.
两级生物选择同步除磷脱氮新工艺   总被引:2,自引:0,他引:2       下载免费PDF全文
针对现有市政污水处理工艺难以兼顾同时生物脱氮除磷的矛盾,结合生活污水低碳氮比的特点,通过在传统的A/O工艺的基础上增设了1个厌氧选择器以提供生物释磷最适宜环境,1个缺氧选择器以避免回流污泥中硝酸盐对厌氧释磷影响以及防止污泥膨胀,开发了一种新型的2级生物选择同步除磷脱氮新工艺.研究表明,应用2级生物选择反硝化除磷脱氮工艺处理生活污水,当进水COD/TN=4.4, COD/TP=33的情况下,稳定期的COD、氨氮、总磷的去除效率分别可达到88%、90%和97%,出水水质达到了国家《城镇污水处理厂污染物排放标准》的一级A标准,反硝化除磷量占总除磷量的35%,并且缺氧段硝酸盐量和缺氧吸磷量成明显的线性关系,平均每消耗1mgNO3--N约吸收1.8mgTP,此线性关系可作为本工艺反硝化除磷的一个重要控制参数.  相似文献   

18.
为了提高系统的反硝化除磷脱氮效率,采用静态试验考察了厌氧反应时间和厌氧段COD对A2O-BAF工艺反硝化聚磷效果的影响,同时对缺氧阶段反硝化聚磷量与脱氮量之间的关系进行了探讨.试验结果发现,在试验范围内,随着厌氧反应时间和厌氧段COD的增加,厌氧释磷量均增加,反硝化聚磷量,净聚磷量和硝氮去除量亦都随之增加,但是反硝化聚磷量与释磷量的比值基本维持不变.在2组8个不同的试验条件下,缺氧段反硝化聚磷量和脱氮量之间均呈现出良好的线性关系,系数为1.007~1.053,R2为0.992~0.997,反映了A2O-BAF系统中污泥的固有特性.  相似文献   

19.
SBR双颗粒污泥系统脱氮除磷性能研究   总被引:2,自引:0,他引:2  
以模拟废水为研究对象,对SBR双颗粒污泥系统的脱氮除磷性能进行了考察.试验结果表明,A2N双颗粒污泥系统能使硝化菌和聚磷菌分别在各自最佳的环境中生长,有利于系统脱氮除磷的稳定和高效运行,可控制性也得到了提高.在COD为300 mg·L-1条件下,系统对COD的平均去除率达到78.8%,大部分COD被聚磷菌用来合成PHA;当溶解氧控制在3.55~4.90 mg·L-1和5.60~6.60 mg·L-1之间时,硝化SBR对氨氮的去除率分别为87.0%和94.5%.除磷SBR仅设置缺氧段时,磷去除率为72%;增设后曝气段后,磷去除率增至85%.NOx--N(NO2--N+ NO3--N)的去除主要发生在缺氧段,在反硝化除磷时作为电子受体被去除,平均去除率为90.6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号