It has long been understood that streambed hydraulic conductivity plays an important role in surface-subsurface solute exchange. Using a portable falling head permeameter in situ, we estimated the horizontal hydraulic conductivity, K, of the near-surface streambed sediments at a total of 85 locations encompassing two depth intervals: 7.5–10 and 10–12.5 cm. The measurements were conducted in an 80 m reach of Indian Creek, a small urban stream in Philadelphia, PA, USA. We found that the ln K data within each sediment layer were Gaussian, but the combined data set was not. The results indicated that while the mean hydraulic conductivity decreased with depth, horizontal heterogeneity (e.g. the variance) increased with depth. This strong contrast between layers suggests that they should be treated as separated entities in modeling studies. Variogram analyses across the stream suggested symmetry with respect to the thalweg in the upper layer and fractality in the lower layer. The variograms along the streams suggested that the K data are random.  相似文献   

2.
The constant‐head permeameter test (CHPT) is widely used in sandy samples as a standard method in the laboratory to investigate hydraulic conductivity (K). However, it neither can be used to consistently determine directional hydraulic conductivity (DHC) nor guarantee the comparability of measured K values of samples with different sizes. Therefore, this paper proposes an integrated laboratory method, called modified CHPT (MCHPT), for the efficient determination and verification of consistent DHC values in fine‐to‐medium sandy sediments, based on a new methodological framework. A precise and standardized procedure for preparing the experimental setup of MCHPT was conducted, based on the integrated experimental setup of CHPT and tracer tests. Moreover, a formula was yielded for the time‐optimized sample saturation control. In comparison with grain size‐based methods, the validity of consistent Kh and Kv values determined by MCHPT was convincing.  相似文献   

3.
The characterization of heterogeneity in hydraulic conductivity (K) is a major challenge for subsurface remediation projects. There are a number of field studies that compare the K estimates obtained using various techniques, but to our knowledge, no field‐based studies exists that compare the performance of estimated K heterogeneity fields or the associated characterization costs. In this paper, we compare the costs of characterizing the three‐dimensional K heterogeneity and its uncertainty estimates of a glaciofluvial aquifer‐aquitard sequence at a 15 m × 15 m × 18 m field site situated on the University of Waterloo campus. We compare geostatistical analysis of high resolution permeameter K data obtained from repacked core samples in five boreholes and hydraulic tomography analysis of four pumping tests consisting of up to 41 monitoring points per test. Aside from the comparison of costs, we also assess the performance of each method by predicting several pumping tests. Our analysis reveals that hydraulic tomography is somewhat more costly than the geostatistical analysis of high resolution permeameter K data due to the higher capital costs associated with the method. However, the equipment may be reused at other sites; hence these costs may be recovered over the life of the equipment. More significantly, hydraulic tomography is able to capture the most important features of the aquifer‐aquitard sequence leading to more accurate predictions of independent pumping tests. This suggests that more robust remediation systems may be designed if site characterization is performed with hydraulic tomography.  相似文献   

4.
Accurate estimation of streambed vertical hydraulic conductivity (Kv) is of great importance in the analysis of water quantity exchange and solute transfer between a stream and its sediments. The paper analyzed the inaccuracy of hydraulic conductivity values of sediments derived from grain-size distribution (Kg), which were determined from eight empirical grain-size methods to represent streambed Kv. In this study, the values of Kv for a streambed were derived using falling-head standpipe permeameter tests conducted at eight study sites in the Elkhorn River, Nebraska, and the tested streambed columns were then collected for grain-size analysis by sieving. These empirical methods were used to calculate the Kg values of the streambed from grain-size distribution data of sediments. Unlike many other studies, this study verifies Kg from grain-size distribution with Kv from permeameter tests on the basis of the same samples of streambed sediments. The Kg values derived from the eight empirical methods were larger than the Kv from permeameter tests; there are five methods that give Kg values of about 3–6 times larger than these Kv. The Kg values from the Kozeny formula followed by the Hazen formula give the largest overestimation error if they are used to represent the Kv of the streambed. The USBR and Shepherd formulas generated Kg values close to Kv, but these Kg values are still larger in general than the Kv values. Moreover, the new values of coefficient C for the empirical formulas were revised so that they can be used to calculate the approximate Kv of a streambed. Among the eight methods, the ratios of the original C values to the average new C range from 1.3 to 5.9. It can be hypothesized that smaller C values must be used in the estimation of Kv for general soil samples if these empirical formulas are used to calculate Kv.  相似文献   

5.
Testing infiltrometer techniques to determine soil hydraulic properties is necessary for specific soils. For a loam soil, the water retention and hydraulic conductivity predicted by the BEST (Beerkan Estimation of Soil Transfer parameters) procedure of soil hydraulic characterization was compared with data collected by more standard laboratory and field techniques. Six infiltrometer techniques were also compared in terms of saturated soil hydraulic conductivity, Ks. BEST yielded water retention values statistically similar to those obtained in the laboratory and Ks values practically coinciding with those determined in the field with the pressure infiltrometer (PI). The unsaturated soil hydraulic conductivity measured with the tension infiltrometer (TI) was reproduced satisfactorily by BEST only close to saturation. BEST, the PI, one‐potential experiments with both the TI and the mini disk infiltrometer (MDI), the simplified falling head (SFH) technique and the bottomless bucket (BB) method yielded statistically similar estimates of Ks, differing at the most by a factor of three. Smaller values were obtained with longer and more soil‐disturbing infiltration runs. Any of the tested infiltration techniques appears usable to obtain the order of magnitude of Ks at the field site, but the BEST, BB and PI data appear more appropriate to characterize the soil at some stage during a rainfall event. Additional investigations on both similar and different soils would allow development of more general procedures to apply infiltrometer techniques for soil hydraulic characterization. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Streambed hydraulic conductivity is one of the main factors controlling variability in surface water‐groundwater interactions, but only few studies aim at quantifying its spatial and temporal variability in different stream morphologies. Streambed horizontal hydraulic conductivities (Kh) were therefore determined from in‐stream slug tests, vertical hydraulic conductivities (Kv) were calculated with in‐stream permeameter tests and hydraulic heads were measured to obtain vertical head gradients at eight transects, each comprising five test locations, in a groundwater‐dominated stream. Seasonal small‐scale measurements were taken in December 2011 and August 2012, both in a straight stream channel with homogeneous elevation and downstream of a channel meander with heterogeneous elevation. All streambed attributes showed large spatial variability. Kh values were the highest at the depositional inner bend of the stream, whereas high Kv values were observed at the erosional outer bend and near the middle of the channel. Calculated Kv values were related to the thickness of the organic streambed sediment layer and also showed higher temporal variability than Kh because of sedimentation and scouring processes affecting the upper layers of the streambed. Test locations at the channel bend showed a more heterogeneous distribution of streambed properties than test locations in the straight channel, whereas within the channel bend, higher spatial variability in streambed attributes was observed across the stream than along the stream channel. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
The vertical hydraulic conductivity (Kv), elastic (Sske), and inelastic (Sskv) skeletal specific storage of aquitards are three of the most critical parameters in land subsidence investigations. Two new analytic methods are proposed to estimate the three parameters. The first analytic method is based on a new concept of delay time ratio for estimating Kv and Sske of an aquitard subject to long‐term stable, cyclic hydraulic head changes at boundaries. The second analytic method estimates the Sskv of the aquitard subject to linearly declining hydraulic heads at boundaries. Both methods are based on analytical solutions for flow within the aquitard, and they are jointly employed to obtain the three parameter estimates. This joint analytic method is applied to estimate the Kv, Sske, and Sskv of a 34.54‐m thick aquitard for which the deformation progress has been recorded by an extensometer located in Shanghai, China. The estimated results are then calibrated by PEST (Doherty 2005), a parameter estimation code coupled with a one‐dimensional aquitard‐drainage model. The Kv and Sske estimated by the joint analytic method are quite close to those estimated via inverse modeling and performed much better in simulating elastic deformation than the estimates obtained from the stress‐strain diagram method of Ye and Xue (2005). The newly proposed joint analytic method is an effective tool that provides reasonable initial values for calibrating land subsidence models.  相似文献   

8.
Saturated hydraulic conductivity (K) is one of the most important parameters determining groundwater flow and contaminant transport in both unsaturated and saturated porous media. Although several well‐established laboratory methods exist for determining K, in situ measurements of this parameter remain very complex and scale dependent. Often, the limited accessibility of subsurface sediments for sampling means an additional impediment to our ability to quantify subsurface K heterogeneity. One potential solution is the use of outcrops as analogues for subsurface sediments. This paper investigates the use of air permeameter measurements on outcrops of unconsolidated sediments to quantify K and its spatial heterogeneity on a broad range of sediment types. The Neogene aquifer in northern Belgium is used as a case study for this purpose. To characterize the variability in K, 511 small‐scale air permeability measurements were performed on outcrop sediments representative over five of the aquifer's lithostratigraphic units. From these measurements, outcrop‐scale equivalent K tensors were calculated using numerical upscaling techniques. Validation of the air permeameter‐based K values by comparison with laboratory constant head K measurements reveals a correlation of 0.93. Overall, the results indicate that hand‐held air permeameters are very efficient and accurate tools to characterize saturated K, as well as its small‐scale variability and anisotropy on a broad range of unconsolidated sediments. The studied outcrops further provided a qualitative understanding of aquifer hydrostratigraphy and quantitative estimates about K variability at the centimetre‐scale to metre‐scale. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
J. Lewis 《Ground water》2016,54(5):740-744
This technical note describes an effective and inexpensive field technique for measuring the saturated hydraulic conductivity of both undisturbed cores and repacked soil samples. The method requires no specialized equipment; everything that is required can be obtained in a hardware store. The method is a straightforward field implementation of the widely used falling‐head laboratory analysis directly derived from Darcy's law. As such, it sidesteps the need for empirical assumptions about soil texture and the relationship between saturated and unsaturated flow components which many permeameter‐based methods rely upon. The method is shown to produce results that are consistent with K values obtained elsewhere in the same homogeneous sand formation. Furthermore, the proposed method is useful for measuring hydraulic conductivity in drill cuttings obtained from direct push or auguring drill techniques, which cannot be done with any other field method. The range of hydraulic conductivity values that this test is appropriate for is on the order of 1E ? 7 m/s to 1E ? 3 m/s.  相似文献   

10.
The saturated hydraulic conductivity, Ks, is a soil property that has a key role in the partitioning of rainfall into surface runoff and infiltration. The commonly used instruments and methods for in situ measurements of Ks have frequently provided conflicting results. Comparison of Ks estimates obtained by three classical devices—namely, the double ring infiltrometer (DRI), the Guelph version of the constant‐head well permeameter (GUELPH‐CHP) and the CSIRO version of the tension permeameter (CSIRO‐TP) is presented. A distinguishing feature in this study is the use of steady deep flow rates, obtained from controlled rainfall–runoff experiments, as benchmark values of Ks at local and field‐plot scales, thereby enabling an assessment of these methods in reliably reproducing repeatable values and in their capability of determining plot‐scale variation of Ks. We find that the DRI grossly overestimates Ks, the GUELPH‐CHP gives conflicting estimates of Ks with substantial overestimation in laboratory experiments and underestimation at the plot scale, whereas the CSIRO‐TP yields average Ks values with significant errors of 24% in the plot scale experiment and 66% in laboratory experiments. Although the DRI would likely yield a better estimate of the nature of variability than the GUELPH‐CHP and CSIRO‐TP, a separate calibration may be warranted to correct for the overestimation of Ks values. The reasons for such discrepancies within and between the measurement methods are not yet fully understood and serve as motivation for future work to better characterize the uncertainty associated with individual measurements of Ks using these methods and the characterization of field scale variability from multiple local measurements.  相似文献   

11.
The forest floor plays an important role in runoff rate, soil erosion and soil infiltration capacity by protecting mineral soils from the direct impact of falling raindrops. Forest floor consists of different kinds of litter with different hydraulic properties. In this study, the inverse method was used to estimate the hydraulic properties of three kinds of forest floor (broad‐leaved, needle‐leaved and mixed‐stand) at three replications in a completely random design. Forest floor samples were collected from the Gilan Province, Iran. The samples were piled up to make long columns 40.88 cm high with an inner diameter of 18.1 cm. Artificial rainfall experiments were conducted on top of the columns, and free drainage from the bottom of the columns was measured in the laboratory. Saturated hydraulic conductivity (Ks), saturated water content and water retention curve parameters (van Genuchten equation) were estimated by the inverse method. The results showed that the Ks of needle‐leaved samples differed significantly (p < 0.05) from those of broad‐leaved and mixed‐stand samples, whereas the latter two did not differ in this regard. No significant differences emerged in the water retention function parameters of van Genuchten (θr, β and α) in the three forest floor samples. The saturated water content of mixed‐stand samples was significantly different (p < 0.05) from that of broad‐leaved and needle‐leaved treatments with the latter two samples showing no significant difference. The good agreement between simulated and observed free drainage for all forest floor samples in the validation period indicates that the estimated hydraulic properties efficiently characterize the unsaturated water flow in the forest floor. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Streambed horizontal hydraulic conductivity (Kh) has a substantial role in controlling exchanges between stream water and groundwater. We propose a new approach for determining Kh of the shallow streambed sediments. Undisturbed sediment samples were collected using tubes that were horizontally driven into streambeds. The sediment columns were analysed using a permeameter test (PT) on site. This new test approach minimizes uncertainties due to vertical flow in the vicinity of test tube and stream stage fluctuations in the computation of the Kh values. Ninety‐eight PTs using the new approach were conducted at eight sites in four tributaries of the Platte River, east‐central Nebraska, USA. The Kh values were compared with the nondirectional hydraulic conductivity values (Kg) determined from 12 empirical grain‐size analysis methods. The grain‐size analysis methods used the same sediment samples as Kh tests. Only two methods, the Terzaghi and Shepherd methods, yielded Kg values close to the Kh values. Although the Sauerbrei method produced a value relatively closer to Kh than other nine grain‐size analysis methods, the values from this method were not as reliable as the methods of Terzaghi and Shepherd due to the inconsistent fluctuation of the average estimates at each of the test sites. The Zunker, Zamarin, Hazen, Beyer, and Kozeny methods overestimated Kh, while the Slichter, US Bureau of Reclamation (USBR), Harleman, and Alyamani and Sen methods underestimated Kh. Any of these specific grain‐size methods might yield good estimates of streambed Kh at some sites, but give poor estimates at other sites, indicating that the relationship between Kg and Kh is significantly site dependent in our study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
The correct use of the tension disc infiltrometer requires the membrane of the disc base to be completely in contact with the soil surface. To achieve this contact, a thick layer of sand is commonly placed between the soil surface and the disc base. This paper presents an alternative disc (MDB), which, by incorporating a malleable membrane, allows direct infiltration measurements without using a contact sand layer. Infiltration curves obtained with this new design in a soil under three different tillage management treatments were compared with the corresponding curves obtained with a conventional disc (CDB) that uses a contact sand layer. The cumulative infiltration curves measured with CDB were analysed by the differentiated linearization (DL) method, and the corresponding curves obtained with MDB were analysed using both the DL and the cumulative linearization (CL) models. The values of hydraulic conductivity (K0) and sorptivity (S0) estimated with CDB were also compared with those obtained with MDB. Finally, the cumulative infiltration curves measured with CDB and MDB were compared with the corresponding modelled function for the respective K0 and S0 values calculated with the CL and DL models. The results show that, compared with CDB without a contact sand layer, MDB allows complete soil surface wetting even when non‐smoothed soil surfaces are used. The CDB, which yielded average K0 values 18% lower than those estimated with MDB, gave the highest values of standard error for the hydraulic parameters calculated. Furthermore, the subjective method employed in the CDB‐DL technique, which requires the first points of the differential infiltration line corresponding to the sand layer to be manually removed, introduces additional uncertainties in estimating S0 and K0. Comparison between the modelled and measured infiltration curves demonstrates that the DL or CL methods applied to MDB gave excellent estimates of S0 and K0. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Over the past several decades, different groundwater modeling approaches of various complexities and data use have been developed. A recently developed approach for mapping hydraulic conductivity (K) and specific storage (Ss) heterogeneity is hydraulic tomography, the performance of which has not been compared to other more “traditional” methods that have been utilized over the past several decades. In this study, we compare seven methods of modeling heterogeneity which are (1) kriging, (2) effective parameter models, (3) transition probability/Markov Chain geostatistics models, (4) geological models, (5) stochastic inverse models conditioned to local K data, (6) hydraulic tomography, and (7) hydraulic tomography conditioned to local K data using data collected in five boreholes at a field site on the University of Waterloo (UW) campus, in Waterloo, Ontario, Canada. The performance of each heterogeneity model is first assessed during model calibration. In particular, the correspondence between simulated and observed drawdowns is assessed using the mean absolute error norm, (L1), mean square error norm (L2), and correlation coefficient (R) as well as through scatterplots. We also assess the various models on their ability to predict drawdown data not used in the calibration effort from nine pumping tests. Results reveal that hydraulic tomography is best able to reproduce these tests in terms of the smallest discrepancy and highest correlation between simulated and observed drawdowns. However, conditioning of hydraulic tomography results with permeameter K data caused a slight deterioration in accuracy of drawdown predictions which suggests that data integration may need to be conducted carefully.  相似文献   

15.
River confluences and their associated tributaries are key morphodynamic nodes that play important roles in controlling hydraulic geometry and hyporheic water exchange in fluvial networks. However, the existing knowledge regarding hyporheic water exchange associated with river confluence morphology is relatively scarce. On January 14 and 15, 2016, the general hydraulic and morphological characteristics of the confluent meander bend (CMB) between the Juehe River and the Haohe River in the southern region of Xi'an City, Shaanxi Province, China, were investigated. The patterns and magnitudes of vertical hyporheic water exchange (VHWE) were estimated based on a one‐dimensional heat steady‐state model, whereas the sediment vertical hydraulic conductivity (Kv) was calculated via in situ permeameter tests. The results demonstrated that 6 hydrodynamic zones and their extensions were observed at the CMB during the test period. These zones were likely controlled by the obtuse junction angle and low momentum flux ratio, influencing the sediment grain size distribution of the CMB. The VHWE patterns at the test site during the test period mostly showed upwelling flow dominated by regional groundwater discharging into the river. The occurrence of longitudinal downwelling and upwelling patterns along the meander bend at the CMB was likely subjected to the comprehensive influences of the local sinuosity of the meander bend and regional groundwater discharge and finally formed regional and local flow paths. Additionally, in dominated upwelling areas, the change in VHWE magnitudes was nearly consistent with that in Kv values, and higher values of both variables generally occurred in erosional zones near the thalweg paths of the CMB, which were mostly made up of sand and gravel. This was potentially caused by the erosional and depositional processes subjected to confluence morphology. Furthermore, lower Kv values observed in downwelling areas at the CMB were attributed to sediment clogging caused by local downwelling flow. The confluence morphology and sediment Kv are thus likely the driving factors that cause local variations in the VHWE of fluvial systems.  相似文献   

16.
Testing the relative performances of the single ring pressure infiltrometer (PI) and simplified falling head (SFH) techniques to determine the field saturated soil hydraulic conductivity, Kfs, at the near point scale may help to better establish the usability of these techniques for interpreting and simulating hydrological processes. A sampling of 10 Sicilian sites showed that the measured Kfs was generally higher with the SFH technique than the PI one, with statistically significant differences by a factor varying from 3 to 192, depending on the site. A short experiment with the SFH technique yielded higher Kfs values because a longer experiment with the PI probably promoted short‐term swelling phenomena reducing macroporosity. Moreover, the PI device likely altered the infiltration surface at the beginning of the run, particularly in the less stable soils, where soil particle arrangement may be expected to vary upon wetting. This interpretation was supported by a soil structure stability index, SSI, and also by the hydraulic conductivity data obtained with the tension infiltrometer, i.e. with a practically negligible disturbance of the sampled soil surface. In particular, a statistically significant, increasing relationship with SSI and an unsaturated conductivity greater than the saturated one were only detected for the Kfs data obtained with the PI. The SFH and PI techniques should be expected to yield more similar results in relatively rigid porous media (low percentages of fine particles and structurally stable soils) than in soils that modify appreciably their particle arrangement upon wetting. The simultaneous use of the two techniques may allow to improve Kfs determination in soils that change their hydrodynamic behaviour during a runoff producing rainfall event. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
Potentiomanometers (PMs) are commonly used to determine flux directions across interfaces between surface waters and aquifers. We describe a complementary function: estimating small‐scale hydraulic conductivity (K) in a lakebed, using the constant‐head injection test (CHIT) by Cardenas and Zlotnik (2003) with the PM designed by Winter et al. (1988). A piezometer with a small screen is inserted into the lakebed. Local head potential is obtained by measuring the head difference between the test point and the aquifer interface. The piezometer is then used for water injection. This technique is illustrated by measurements taken from Alkali Lake in the Sand Hills, Nebraska, United States. Lakebed K and seepage fluxes ranged from 0.037 to 0.090 m/d and Darcy velocities ranged from 0.004 to 0.027 m/d. Results were consistent with the supplementary data gathered using a modified CHIT and a cone penetrometer. The compact size of the device and the small volumes used for injection enable this method to estimate lakebed K values as low as 0.01 to 0.1 m/d, a range seldom explored in lake‐aquifer interface systems.  相似文献   

18.
Relationship between different geomechanical and acoustic properties measured from seven laboratory-tested unconsolidated natural sands with different mineralogical compositions and textures were presented. The samples were compacted in the uniaxial strain configuration from 0.5 to 30 MPa effective stress. Each sand sample was subjected to three loading–unloading cycles to study the influence of stress reduction. Geomechanical, elastic and acoustic parameters are different between normal compaction and overconsolidation (unloaded and reloaded). Stress path (K0) data differ between normal consolidated and overconsolidated sediments. The K0 value of approximately 0.5 is founded for most of the normal consolidated sands, but varies during unloading depending on mineral compositions and textural differences. The K0 and overconsolidation ratio relation can be further simplified and can be influenced by the material compositions. K0 can be used to estimate horizontal stress for drilling applications. The relationship between acoustic velocity and geomechanical is also found to be different between loading and unloading conditions. The static moduli of the overconsolidated sands are much higher than normal consolidated sands as the deformation is small (small strain). The correlation between dynamic and static elastic moduli is stronger for an overconsolidation stage than for a normal consolidation stage. The results of this study can contribute to geomechanical and acoustic dataset which can be applied for many seismic-geomechanics applications in shallow sands where mechanical compaction is the dominant mechanism.  相似文献   

19.
This study evaluated the spatial variability of streambed vertical hydraulic conductivity (Kv) in different stream morphologies in the Frenchman Creek Watershed, Western Nebraska, using different variogram models. Streambed Kv values were determined in situ using permeameter tests at 10 sites in Frenchman, Stinking Water and Spring Creeks during the dry season at baseflow conditions. Measurements were taken both in straight and meandering stream channels during a 5 day period at similar flow conditions. Each test site comprised of at least three transects and each transect comprised of at least three Kv measurements. Linear, Gaussian, exponential and spherical variogram models were used with Kriging gridding method for the 10 sites. As a goodness-of-fit statistic for the variogram models, cross-validation results showed differences in the median absolute deviation and the standard deviation of the cross-validation residuals. Results show that using the geometric means of the 10 sites for gridding performs better than using either all the Kv values from the 93 permeameter tests or 10 Kv values from the middle transects and centre permeameters. Incorporating both the spatial variability and the uncertainty involved in the measurement at a reach segment can yield more accurate grid results that can be useful in calibrating Kv at watershed or sub-watershed scales in distributed hydrological models.  相似文献   

20.
The estimation of recharge through groundwater model calibration is hampered by the nonuniqueness of recharge and aquifer parameter values. It has been shown recently that the estimability of spatially distributed recharge through calibration of steady‐state models for practical situations (i.e., real‐world, field‐scale aquifer settings) is limited by the need for excessive amounts of hydraulic‐parameter and groundwater‐level data. However, the extent to which temporal recharge variability can be informed through transient model calibration, which involves larger water‐level datasets, but requires the additional consideration of storage parameters, is presently unknown for practical situations. In this study, time‐varying recharge estimates, inferred through calibration of a field‐scale highly parameterized groundwater model, are systematically investigated subject to changes in (1) the degree to which hydraulic parameters including hydraulic conductivity (K) and specific yield (Sy) are constrained, (2) the number of water‐level calibration targets, and (3) the temporal resolution (up to monthly time steps) at which recharge is estimated. The analysis involves the use of a synthetic reality (a reference model) based on a groundwater model of Uley South Basin, South Australia. Identifiability statistics are used to evaluate the ability of recharge and hydraulic parameters to be estimated uniquely. Results show that reasonable estimates of monthly recharge (<30% recharge root‐mean‐squared error) require a considerable amount of transient water‐level data, and that the spatial distribution of K is known. Joint estimation of recharge, Sy and K, however, precludes reasonable inference of recharge and hydraulic parameter values. We conclude that the estimation of temporal recharge variability through calibration may be impractical for real‐world settings.  相似文献   