首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
This study was performed to examine exposure to typical carcinogenic traffic air pollutants in the city center of an urban area. In all, 123 apartments and 74 nursery schools were analyzed with and without tobacco smoke interference and the households in two measuring periods. Simultaneously, the air outside 61 apartment windows as well as the average daily traffic volume were measured. Elemental carbon (EC), the marker for particulate diesel exhaust and respirable particulate matter (RPM) were determined. The thermographic EC analysis was conducted with and without prior solvent extraction of the soluble carbon fraction. Comparison of these two thermographic EC measurements clearly showed that method-related differences in the results, especially for indoor measurements, when high background loads of organic material were present (e.g. tobacco smoke), existed. Solvent extraction prior to EC determination was therefore appropriate. For the first winter measuring period, the EC concentration levels without solvent extraction in the indoor air were about 50% higher than those measured in the spring/summer period. In the second measuring period (i.e. spring/summer), the median EC concentrations after solvent extraction were 1.9 microg/m3 for smokers' apartments and 2.1 microg/m3 for non-smokers' apartments, with RPM concentrations of 57 and 27 microg/m3, respectively. Nursery schools showed high concentrations with median values of 53 microg/m3 for RPM and 2.9 microg/m3 for EC after solvent extraction. A significant correlation between the fine dust and EC concentrations (after solvent extraction) in the indoor and ambient air was determined. Outdoor EC values were also correlated with the average daily traffic volume. The EC ratios between indoor and ambient concentration showed a median of 0.8 (range: 0.3-4.2) in non-smoker households and 0.9 (range: 0.4-1.5) in smoker apartments. Furthermore, the EC/RPM ratio in indoor and ambient air was 0.01-0.15 (median 0.06) and 0.04-0.37 (median 0.09), respectively. PRACTICAL IMPLICATIONS: In the absence of indoor sources a significant correlation with regard to respirable particulate matter (RPM) and elemental carbon concentrations between the indoor and ambient air of apartments was observed. The high degree of certainty resulting from this correlation underscores the importance of ambient air concentrations for indoor air quality. In nursery schools we found higher concentrations of RPM. An explanation of these results could be the high number of occupants in the room, their activity and the cleaning intensity.  相似文献   

2.
3.
4.
A single-blinded study was performed to analyze whether indoor environments with and without mold infestation differ significantly in microbial volatile organic compounds (MVOC) concentrations. Air sampling for MVOC was performed in 40 dwellings with evident mold damage and in 44 dwellings, where mold damage was excluded after a thorough investigation. The characteristics of the dwellings, climatic parameters, airborne particles and air exchange rates (AER) were recorded. The parameters mold status, characteristics of the interiors and measured climatic parameters were included in the multiple regression model. The results show no significant association between most of the analyzed MVOC and the mold status. Only the compounds 2-methyl-1-butanol and 1-octen-3-ol indicated a statistically significant, but weak association with the mold status. However, the concentrations of the so-called MVOC were mainly influenced by other indoor factors. 2-Methylfuran and 3-methylfuran, often used as main indicators for mold damage, had a highly significant correlation with the smoking status. These compounds were also significantly correlated with the humidity and the AER. The compounds 3-methyl-1-butanol, 2-hexanone, 3-heptanone and dimethyl disulfide were weakly correlated with the recorded parameters, the humidity being the strongest influencing factor. Only 2-methyl-1-butanol and 1-octen-3-ol showed a statistically significant association with the mold status; however, only a small portion (10% in this case) of the total variability could be explained by the predictor mold status; they do not qualify as indicator compounds, because such minor correlations lead to a too excessive part of incorrect classifications, meaning that the diagnostic sensitivity and specificity of these compounds are too low. PRACTICAL IMPLICATIONS: The assumption that mold infestations might be detected by microbial VOC emissions must be considered with great reservation. The major part of the total variability of the measured MVOC concentrations originates from not known influencing factors and/or from factors not directly associated with the mold status of the dwellings (confounders). More specific and sensitive markers for the assessment of the mold status should be found, if the screening for mold infestations should be performed by volatile organic compounds.  相似文献   

5.
6.
7.
H. Zhao  B. Stephens 《Indoor air》2017,27(1):218-229
Much of human exposure to particulate matter of outdoor origin occurs inside buildings, particularly in residences. The particle penetration factor through leaks in a building's exterior enclosure assembly is a key parameter that governs the infiltration of outdoor particles. However, experimental data for size‐resolved particle penetration factors in real buildings, as well as penetration factors for fine particles less than 2.5 μm (PM2.5) and ultrafine particles less than 100 nm (UFPs), remain limited, in part because of previous limitations in instrumentation and experimental methods. Here, we report on the development and application of a modified test method that utilizes portable particle sizing instrumentation to measure size‐resolved infiltration factors and envelope penetration factors for 0.01–2.5 μm particles, which are then used to estimate penetration factors for integral measures of UFPs and PM2.5. Eleven replicate measurements were made in an unoccupied apartment unit in Chicago, IL to evaluate the accuracy and repeatability of the test procedure and solution methods. Mean estimates of size‐resolved penetration factors ranged from 0.41 ± 0.14 to 0.73 ± 0.05 across the range of measured particle sizes, while mean estimates of penetration factors for integral measures of UFPs and PM2.5 were 0.67 ± 0.05 and 0.73 ± 0.05, respectively. Average relative uncertainties for all particle sizes/classes were less than 20%.  相似文献   

8.
Inadequate ventilation of classrooms may lead to increased concentrations of pollutants generated indoors in schools. The FRESH study, on the effects of increased classroom ventilation on indoor air quality, was performed in 18 naturally ventilated classrooms of 17 primary schools in the Netherlands during the heating seasons of 2010–2012. In 12 classrooms, ventilation was increased to targeted CO2 concentrations of 800 or 1200 ppm, using a temporary CO2 controlled mechanical ventilation system. Six classrooms were included as controls. In each classroom, data on endotoxin, β(1,3)‐glucans, and particles with diameters of <10 μm (PM10) and <2.5 μm (PM2.5) and nitrogen dioxide (NO2) were collected during three consecutive weeks. Associations between the intervention and these measured indoor air pollution levels were assessed using mixed models, with random classroom effects. The intervention lowered endotoxin and β(1,3)‐glucan levels and PM10 concentrations significantly. PM10 for instance was reduced by 25 μg/m³ (95% confidence interval 13–38 μg/m³) from 54 μg/m³ at maximum ventilation rate. No significant differences were found between the two ventilation settings. Concentrations of PM2.5 and NO2 were not affected by the intervention. Our results provide evidence that increasing classroom ventilation is effective in decreasing the concentrations of some indoor‐generated pollutants.  相似文献   

9.
Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well‐mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single‐zone AER (AER1z). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two‐zone AER estimate (AER2z). In total, 287 daily pairs of AER2z and AER1z estimates were made from 35 homes across three cities. In 87% of the cases, AER2z was higher than AER1z. Overall, the AER1z estimates underestimated AER2z by approximately 16% (IQR: 5–32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well‐mixed air zone very likely results in an under prediction of the AER.  相似文献   

10.
Uptake kinetics of semi‐volatile organic compounds (SVOCs) present indoors, namely phthalates and halogenated flame retardants (HFRs), were characterized for cellulose‐based cotton and rayon fabrics. Cotton and rayon showed similar accumulation of gas‐ and particle‐phase SVOCs, when normalized to planar surface area. Accumulation was 3–10 times greater by rayon than cotton, when normalized to Brunauer–Emmett–Teller (BET) specific surface area which suggests that cotton could have a longer linear uptake phase than rayon. Linear uptake rates of eight consistently detected HFRs over 56 days of 0.35–0.92 m3/day.dm2 planar surface area and mass transfer coefficients of 1.5–3.8 m/h were statistically similar for cotton and rayon and similar to those for uptake to passive air sampling media. These results suggest air‐side controlled uptake and that, on average, 2 m2 of clothing typically worn by a person would sequester the equivalent of the chemical content in 100 m3 of air per day. Distribution coefficients between fabric and air (K′) ranged from 6.5 to 7.7 (log K′) and were within the range of partition coefficients measured for selected phthalates as reported in the literature. The distribution coefficients were similar for low molecular weight HFRs, and up to two orders of magnitude lower than the equilibrium partition coefficients estimated using the COSMO‐RS model. Based on the COSMO‐RS model, time to reach 95% of equilibrium for PBDEs between fabric and gas‐phase compounds ranged from 0.1 to >10 years for low to high molecular weight HFRs.  相似文献   

11.

Introduction

Owing to their small size, fine particles, i.e., those having a diameter ≤ 2.5 μm (PM2.5), have a high alveolar penetration capacity, thereby triggering a local inflammatory process with circulatory repercussion. Despite being linked to respiratory and cardiovascular morbidities, there is limited evidence of an association between this type of particulate matter and short-term increases in mortality.

Objective

The aim of this study was to analyse and quantify the short-term impact of PM2.5 on daily mortality due to diseases of the circulatory system, registered in Madrid from 1 January 2003 to 31 December 2005.

Methods

An ecological longitudinal time-series study was conducted, with risks being quantified by means of Poisson regression models. As a dependent variable, we took daily mortality registered in Madrid from 1 January 2003 to 31 December 2005, attributed to all diseases of the circulatory system as classified under heads I00-I99 of the International Classification of Diseases-10th revision (ICD-10) and broken down as follows: I21, acute myocardial infarction (AMI); I20, I22-I25, other ischemic heart diseases; and I60-I69, cerebrovascular diseases. The independent variable was daily mean PM2.5 concentration. The other variables controlled for were: chemical pollution (PM10, O3, SO2, NO2 and NOx); acoustic and biotic pollution; influenza; minimum and maximum temperatures; seasonalities; trend; and autocorrelation of the series.

Results

A linear relationship was observed between PM2.5 levels and mortality due to diseases of the circulatory system. For every increase of 10 μg/m3 in daily mean PM2.5 concentration, the relative risks (RR) were as follows: for overall circulatory mortality, associations were established at lags 2 and 6, with RR of 1.022 (1.005-1.039) and 1.025 (1.007-1.043) respectively; and for AMI mortality, there was an association at lag 6, with an RR of 1.066 (1.032-1.100). The corresponding attributable risks percent (AR%) were 2.16%, 2.47% and 6.21% respectively. No statistically significant association was found with other ischemic heart diseases or with cerebrovascular diseases.

Conclusion

PM2.5 concentrations are an important risk factor for daily circulatory-cause mortality in Madrid. From a public health point of view, the planning and implementation of specific measures targeted at reducing these levels constitute a pressing need.  相似文献   

12.
Low-cost airborne particle sensors are gaining attention for monitoring human exposure to indoor particulate matter. This study aimed to establish the concentrations at which these commercially available sensors can be expected to report accurate concentrations. We exposed five types of commercial integrated devices and three types of “bare” low-cost particle sensors to a range of concentrations generated by three different sources. We propose definitions of upper and lower bounds of functional range based on the relationship between a given sensor's output and that of a reference instrument during a laboratory experiment. Experiments show that the lower bound can range from approximately 3 to 15 μg/m3. At greater concentrations, sensor output deviates from linearity at approximately 300-3000 μg/m3. We also conducted a simulation campaign to analyze the effect of this limitation on functional range on the accuracy of exposure readings given by these devices. We estimate that the upper bound results in minimal inaccuracy in exposure quantification, and the lower bound can result in as much as a 50% error in approximately 10% of US homes.  相似文献   

13.
Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneumonia in infants and children in The Gambia. We conducted co-located simultaneous area measurement of carbon monoxide (CO) and particles with aerodynamic diameter <2.5 microm (PM(2.5)) in 13 households for 48 h each. CO was measured using a passive integrated monitor and PM(2.5) using a continuous monitor. In three of the 13 households, we also measured continuous PM(2.5) concentration for 2 weeks in the cooking, sleeping, and playing areas. We used gravimetric PM(2.5) samples as the reference to correct the continuous PM(2.5) for instrument measurement error. Forty-eight hour CO and PM(2.5) concentrations in the cooking area had a correlation coefficient of 0.80. Average 48-h CO and PM(2.5) concentrations in the cooking area were 3.8 +/- 3.9 ppm and 361 +/- 312 microg/m3, respectively. The average 48-h CO exposure was 1.5 +/- 1.6 ppm for children and 2.4 +/- 1.9 ppm for mothers. PM(2.5) exposure was an estimated 219 microg/m3 for children and 275 microg/m3 for their mothers. The continuous PM(2.5) concentration had peaks in all households representing the morning, midday, and evening cooking periods, with the largest peak corresponding to midday. The results are used to provide specific recommendations for measuring the exposure of infants and children in an epidemiological study. PRACTICAL IMPLICATIONS: Measuring personal particulate matter (PM) exposure of young children in epidemiological studies is hindered by the absence of small personal monitors. Simultaneous measurement of PM and carbon monoxide suggests that a combination of methods may be needed for measuring children's PM exposure in areas where household biomass combustion is the primary source of indoor air pollution. Children's PM exposure in biomass burning homes in The Gambia is substantially higher than concentrations in the world's most polluted cities.  相似文献   

14.
A simple method for the collection and analysis of the four brominated and chlorinated trihalomethanes (THMs) in air samples is described. Ambient air samples were collected in pre‐prepared glass vials, with THM analysis performed using solid‐phase microextraction gas chromatography‐mass spectrometry, where the need for chemical reagents is minimized. Analytical parameters, including oven temperature program, solvent volume, incubation time, vial agitation, extraction time and temperature, as well as desorption time and temperature, were evaluated to ensure optimal method performance. The developed method allows for point‐in‐time quantification (compared to an average concentration measured over extended periods of time), with detection limits between 0.7 to 2.6 µg/m3. Excellent linearity (r> 0.99), repeatability (3% to 11% RSD), and reproducibility (3% to 16% RSD) were demonstrated over a concentration range from 2 to 5000 µg/m3. The method was validated for the analysis of THMs in indoor swimming pool air and was used to investigate the occurrence of THMs in the air above 15 indoor swimming pools. This is the first study to report the occurrence of THMs in swimming pool air in Australia, and concentrations higher than those previously reported in other countries were measured.  相似文献   

15.
High‐efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost‐effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP‐HEPA filtration has not been examined. We conducted an intervention study in 89 volunteers. At baseline, the air‐handling units of offices and residences for all subjects were comprised of coarse, ESP, and HEPA filtration. During the 5‐week long intervention, the subjects were split into 2 groups, 1 with just the ESP removed and the other with both the ESP and HEPA removed. Each subject was measured for cardiopulmonary risk indicators once at baseline, twice during the intervention, and once 2 weeks after baseline conditions were restored. Measured indoor and outdoor PM2.5 and ozone concentrations, coupled with time‐activity data, were used to calculate exposures. Removal of HEPA filters increased 24‐hour mean PM2.5 exposure by 38 (95% CI: 31, 45) μg/m3. Removal of ESPs decreased 24‐hour mean ozone exposure by 2.2 (2.0, 2.5) ppb. No biomarkers were significantly associated with HEPA filter removal. In contrast, ESP removal was associated with a ?16.1% (?21.5%, ?10.4%) change in plasma‐soluble P‐selectin and a ?3.0% (?5.1%, ?0.8%) change in systolic blood pressure, suggesting reduced cardiovascular risks.  相似文献   

16.
One of the most notable Indoor Air Quality problems is odor emission. This study investigated the potential contribution of skin squames to the production of ammonia (NH3) and volatile organic acids (VFAs) by 7 bacteria isolated from air‐cooling (AC) units with complaints of urine and body odors. Our previous study showed that keratinolytic activity is higher in AC units with odor complaints than those without. In the offices where these units are located, the most likely source of keratins is from human skin squames. Most bacteria can produce NH3 and VFAs in the skin squame culture. Some correlations between the levels of NH3, , VFAs, and keratinolytic activity were found. The odor production pathway with skin squames was proposed. Staphylococcus haemolyticus was abundant in the AC units with odor problems and had a high level of keratinolytic activity in addition to odor production. For long‐term odor control, it is important to reduce the level of skin squames entering the AC units.  相似文献   

17.
Abstract  We performed 124 measurements of particulate matter (PM2.5) in 95 hospitality venues such as restaurants, bars, cafés, and a disco, which had differing smoking regulations. We evaluated the impact of spatial separation between smoking and non-smoking areas on mean PM2.5 concentration, taking relevant characteristics of the venue, such as the type of ventilation or the presence of additional PM2.5 sources, into account. We differentiated five smoking environments: (i) completely smoke-free location, (ii) non-smoking room spatially separated from a smoking room, (iii) non-smoking area with a smoking area located in the same room, (iv) smoking area with a non-smoking area located in the same room, and (v) smoking location which could be either a room where smoking was allowed that was spatially separated from non-smoking room or a hospitality venue without smoking restriction. In these five groups, the geometric mean PM2.5 levels were (i) 20.4, (ii) 43.9, (iii) 71.9, (iv) 110.4, and (v) 110.3 μg/m³, respectively. This study showed that even if non-smoking and smoking areas were spatially separated into two rooms, geometric mean PM2.5 levels in non-smoking rooms were considerably higher than in completely smoke-free hospitality venues.  

Practical Implications


PM2.5 levels are considerably increased in the non-smoking area if smoking is allowed anywhere in the same location. Even locating the smoking area in another room resulted in a more than doubling of the PM2.5 levels in the non-smoking room compared with venues where smoking was not allowed at all. In practice, spatial separation of rooms where smoking is allowed does not prevent exposure to environmental tobacco smoke in nearby non-smoking areas.  相似文献   

18.
W. Dong  L. Pan  H. Li  M. R. Miller  M. Loh  S. Wu  J. Xu  X. Yang  J. Shan  Y. Chen  F. Deng  X. Guo 《Indoor air》2018,28(3):373-382
Associations between size‐fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty‐nine healthy elderly women were measured for 24‐hour HRV/HR indices. Real‐time size‐fractionated indoor PM and BC were monitored on the same day and on the preceding day. Mixed‐effects models were applied to investigate the associations between pollutants and HRV/HR indices. Increases in size‐fractionated indoor PM were significantly associated with declines in power in the high‐frequency band (HF), power in the low‐frequency band (LF), and standard deviation of all NN intervals (SDNN). The largest decline in HF was 19% at 5‐minute moving average for an interquartile range (IQR) increase (24 μg/m3) in PM0.5. The results showed that smaller particles could lead to greater reductions in HRV indices. The reported associations were modified by body mass index (BMI): Declines in HF at 5‐minute average for an IQR increase in PM0.5 were 34.5% and 1.0% for overweight (BMI ≥25 kg/m2) and normal‐weight (BMI <25 kg/m2) participants, respectively. Moreover, negative associations between BC and HRV indices were found to be significant in overweight participants. Increases in size‐fractionated indoor PM and BC were associated with compromised cardiac autonomic function in healthy elderly women, especially overweight ones.  相似文献   

19.
Few studies have examined indoor air quality in First Nations communities and its impact on cardiorespiratory health. To address this need, we conducted a crossover study on a First Nations reserve in Manitoba, Canada, including 37 residents in 20 homes. Each home received an electrostatic air filter and a placebo filter for 1 week in random order, and lung function, blood pressure, and endothelial function measures were collected at the beginning and end of each week. Indoor air pollutants were monitored throughout the study period. Indoor PM2.5 decreased substantially during air filter weeks relative to placebo (mean difference: 37 μg/m3, 95% CI: 10, 64) but remained approximately five times greater than outdoor concentrations owing to a high prevalence of indoor smoking. On average, air filter use was associated with a 217‐ml (95% CI: 23, 410) increase in forced expiratory volume in 1 s, a 7.9‐mm Hg (95% CI: ?17, 0.82) decrease in systolic blood pressure, and a 4.5‐mm Hg (95% CI: ?11, 2.4) decrease in diastolic blood pressure. Consistent inverse associations were also observed between indoor PM2.5 and lung function. In general, our findings suggest that reducing indoor PM2.5 may contribute to improved lung function in First Nations communities.  相似文献   

20.
Research was conducted to study the effect of heat pipe heat exchangers on the existing air conditioning system of a hospital ward located in Malaysia, a tropical region. The present research employs the transient system simulation software (TRNSYS) to study the hour-by-hour performance of the system in terms of supply duct air and indoor air conditions in the ward space. Fieldwork study showed that the existing air conditioning system operating in the Orthopaedic Ward, University of Malaya, Malaysia is not capable of providing the desired supply duct air and indoor air to the space. Therefore, the possibility of improving the air conditioning system by adding heat pipe heat exchangers was investigated. The impact on energy consumption, power savings, supply duct air and indoor air with heat pipe heat exchangers incorporated in the air conditioning system were simulated and the results were compared with the existing system.Based on the present research, the system with the added eight-row heat pipe heat exchangers is recommended to provide convenient and healthy air into the ward space according to the ASHRAE recommendations. Moreover, it was found that by applying the new design, a considerable amount of energy and power could be saved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号