首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rapid, simple and reliable HPLC/DAD and LC‐ESI‐MS methods for the simultaneous determination of baicalin and forsythin in the traditional Chinese medicinal preparation Shuanghuanglian oral liquid were described and validated. The separation condition for HPLC/DAD was optimized using a BDS hypersil C18 column (Thermo, 2.1 × 150 mm, particle size 5 μm) by gradient elution using methanol‐0.2 % ammonium acetate as the mobile phase. The suitable detection wavelength was set at 277 nm for the quantitative analysis of baicalin and forsythin in this method. Some operational parameters of the ESI interface were optimized, negative m/z 445[M?H]? for baicalin and negative m/z 593[M+CH3COO]? for forsythin, positive m/z 447[M+H]+ for baicalin and positive m/z 552[M+NH 4]+ for forsythin, respectively. These HPLC/DAD and LC‐ESI‐MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). These methods can be used as a complementary method for the commercial quality control of Shuanghuanglian oral liquid and its pharmaceutical preparations.  相似文献   

2.
The use of blood spot collection cards is a simple way to obtain specimens for therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in a clinical setting. A high‐throughput liquid chromatography–electrospray ionization mass spectrometric (LC‐ESI‐MS) method for determination of rifaximin on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase LC on a monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI‐MS. Rifampicin was used as an internal standard (IS). The run time was within 5.0 min with a very low back‐pressure at a flow rate of 0.5 mL/min. The assay was linear from 0.1 to 10 ng/mL. The mean recovery was 98.42%. The developed method is very simple, rapid and useful for clinical applications. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
A quantitative analysis of polyamines in lung cancer patient fingernails by the combination of 4‐(N,N‐dimethylaminosulfonyl)‐7‐fluoro‐2,1,3‐benzoxadiazole derivatives and liquid chromatography–electrospray ionization tandem mass spectrometry is described. The reaction of the reagent with eight kinds of polyamines, that is, N1‐acetylputrescine (N1‐actPUT), N8‐acetylspermidine, N1‐acetylspermine, 1,3‐diaminopropane, putrescine (PUT), cadaverine, spermidine and spermine (SPM) effectively occurs at 60 °C for 30 min. The detection limits (signal‐to‐noise ratio 5) were 5–100 fmol. A good linearity was achieved from the calibration curves, which was obtained by plotting the peak area ratios of the analytes relative to the internal standard (IS), that is, 1,6‐diaminohexane, vs the injected amounts of polyamines (r2 > 0.996), and the intra‐day and inter‐day assay precisions were <9.84%. Furthermore, the recoveries (%) of the polyamines spiked in the human fingernails were 89.14–110.64. The present method was applied to human fingernail samples from 17 lung cancer patients and 39 healthy volunteers. The polyamine concentration was different based on the gender, that is, the N1‐actPUT and PUT contents were 3.10 times and 2.56 times higher in healthy men than in women, respectively. Additionally, in the lung cancer patient group, as compared with the healthy volunteers, the concentrations of SPM had a statistically significant (p < 0.05) correlation. Therefore, because the proposed method provides a good mass accuracy and the trace detection of the polyamines in human fingernails, this analytical technique could be a noninvasive technique to assist in the diagnosis and assessment of disease activity in lung cancer patients. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A simple and reliable LC‐ESI‐MS method for the determination of peimine and peiminine in rat plasma was developed for the first time. The method was proven to be specific and sensitive by carrying out validation. The analytes were extracted from rat plasma via solid‐phase extraction on Waters Oasis MCX cartridges. Chromatography separation was achieved on a C18 column using 10 mM ammonium acetate (adjusted to pH 3.0 with glacial acetic acid)–acetonitrile (85:15, v/v) as mobile phase. The linear range was 1–100 ng/mL for peimine and peiminine. Intra‐ and inter‐day precisiond were less than 10%. Accuracies were within 85–115% of their nominal concentrations. The limit of quantification was 1 ng/mL for both analytes. The developed assay was successfully applied to pharmacokinetic study of peimine and peiminine in rats orally administered the alkaloids extracts from Bulbus Fritillariae, demonstrating a possible broader spectrum of applications of this method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A sensitive and efficient liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of piperaquine (PQ) and its N ‐oxidated metabolite (PQ‐M) in plasma. A simple protein precipitation procedure was used for sample preparation. Adequate chromatographic retention was achieved on a C18 column under gradient elution with acetonitrile and 2 mm aqueous ammonium acetate containing 0.15% formic acid and 0.05% trifluoroacetic acid. A triple‐quadrupole mass spectrometer equipped with an electrospray source was set up in the positive ion mode and multiple reaction monitoring mode. The method was linear in the range of 2.0–400.0 ng/mL for PQ and 1.0–50.0 ng/mL for PQ‐M with suitable accuracy, precision and extraction recovery. The lower limits of detection (LLOD) were established at 0.4 and 0.2 ng/mL for PQ and PQ‐M, respectively, using 40 μL of plasma sample. The matrix effect was negligible under the current conditions. No effect was found for co‐administrated artemisinin drugs or hemolysis on the quantification of PQ and PQ‐M. Stability testing showed that two analytes remained stable under all relevant analytical conditions. The validated method was successfully applied to a pharmacokinetic study performed in rats after a single oral administration of PQ (60 mg/kg).  相似文献   

6.
An HPLC method permitting the simultaneous determination of fourteen analytes (phenylalkanoids and monoterpenoids) from the roots of Rhodiola rosea was developed. A separation was achieved within 35 min using C18 column material and a water–acetonitrile mobile phase, both containing a 0.05% phosphoric acid gradient system and a temperature of 53°C. The method was validated for linearity, repeatability, limits of detection and limits of quantification. The limits of detection and limits of quantification of 14 phenylalkanoids and monoterpenoids were found to be 0.20–1.0 and 0.5–3.5 µg/mL, respectively. The wavelengths used for quantification of phenylalkanoids and monoterpenoids with a diode array detector were 205, 220 and 251 nm. The method was used to analyze the roots of two species of Rhodiola and commercial extracts of R. rosea and provides preliminary evidence of phytochemical differences between North American and Eurasian populations of R. rosea. LC–mass spectrometry coupled with electrospray ionization (ESI) interface method is described for the identification of phenylalkanoids and monoterpenoids in various Rhodiola samples. This method involved the use of the [M + H]+, [M + NH4]+ and [M + Na]+ ions in the positive ion mode with extractive ion monitoring (EIM). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A method employing ultra‐high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) for determination of eight components including ferulic acid, senkyunolide A, butylphthalide, ligustilide, butylidenephalide, senkyunolide I, senkyunolide H and levistolide A in Angelica sinensis was established. The separation was carried out using a Waters ACQUITY UHPLC BEH C18 column with gradient elution with 0.1% formic acid aqueous and acetonitrile at a flow rate of 0.4 mL/min. Good linearity was attained with R2 of 0.9983–0.9998 in wide concentration ranges. The method had limit of detection (LOD) and quantitation (LOQ) in the range of 0.42–6.98 ng/mL and 1.39–23.28 ng/mL, respectively. Intra‐ and inter‐day precisions varied with relative standard deviations (RSDs) from 0.33% to 0.88% and 0.37% to 1.04%, respectively. Moreover, the average recoveries were in a satisfactory range of 92.7%–102.1% with RSDs of less than 3.60%. Finally, the method was successfully applied to analyze 19 batches of A. sinensis samples grown in Min County, Gansu province, China, as well as that collected in other regions. The findings indicated that the established method is reliable and may thus be applied as a powerful tool for qualitative and quantitative analysis of components in A. sinensis, which has its implications in quality control of A. sinensis.  相似文献   

8.
Radix Scutellariae (RS) is a herbal medicine with various pharmacological activities to treat inflammation, respiratory and gastrointestinal infections, etc. In this study, a rapid, sensitive and selective UPLC‐ESI‐MS/MS method was developed for simultaneous determination of 10 flavonoids – scutellarin, scutellarein, chrysin, wogonin, baicalein, apigenin, wogonoside, oroxylin A‐7‐O‐glucuronide, oroxylin A and baicalin – from RS aqueous extracts in rat plasma with propyl paraben as internal standard (IS). Chromatographic separation was achieved on a C18 column using gradient elution with the mobile phase consisting of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min. The detection was performed in multiple reaction monitoring mode using electrospray ionization in negative mode. The validated method showed good linearity over a wide concentration range (r >0.9935). The intra‐ and interday assay variabilities were <9.5% and <12.4% for all analytes, respectively. The extraction recovery ranged from 71.2 to 89.7% for each analyte and IS. This method was successfully applied to pharmacokinetic comparision after oral administration of crude and wine‐processed RS aqueous extracts. There were significant differences in some pharmacokinetic parameters of most analytes between crude and wine‐processed RS. This suggested that wine‐processing exerted effects absorption of most flavonoids. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Structural modification of a polypeptide hormone, glucagon, by a hydroxyl radical in vitro was investigated by reversed‐phase high‐performance liquid chromatography (RP‐HPLC), and the oxidized site of glucagon was detected by electrospray ionization tandem mass spectrometry (ESI‐MS/MS). It was shown that 27methionine (Met) was oxidized to 27Met sulfoxide by hydroxyl radical, and the production rate of 27Met sulfoxide was faster than that by hydrogen peroxide. In addition, production of 27Met sulfoxide enantiomer was confirmed by RP‐HPLC analysis. cAMP production in a HepG2 cell induced by 27Met sulfoxide glucagon was reduced to approximately 75% as compared with that induced by the native form of glucagon. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A simple and sensitive method was developed and validated for the simultaneous determination of 103 pesticide residues in tea by LC‐MS/MS. For the analysis of the pesticide with polarity, thermal lability or low volatility, this LC‐MS/MS method has an advantage over GC. In this work, residual pesticides were extracted from the tea sample with ACN and then purified using Carb‐NH2 SPE cartridges. Using the multiple reaction monitoring mode, the pesticides were quantified and identified by the most abundant and characteristic fragment ions. The recoveries obtained for each pesticide ranged between 65 and 114% at three spiked concentration levels. The intra‐day precisions were lower than 19.6%. Good linear relationships were observed with the correlation coefficients r2 >0.996 for all analytes. The established method was successfully applied to the determination of pesticide residues in real tea samples.  相似文献   

13.
LC‐ ESI‐ MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin‐d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid–liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin‐d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis‐RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025–753.217 ng/mL for acitretin and 0.394–289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra‐day and inter‐day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Acorus tatarinowii Schott (ATS) is a well‐known traditional Chinese medicine (TCM) for the treatment of epilepsy, amnesia and insomnia. In this study, a methodology utilizing high‐performance liquid chromatography (HPLC) coupled with electrospray ionization quadrupole time‐of‐flight mass spectrometry (ESI‐QTOF‐MS/MS) was established for the separation and structural identification of the major chemical constituents in ATS for the first time. Overall, 46 major constituents including flavonoid glycosides, phenylpropane derivatives, amides and lignans were identified or tentatively characterized. Seven major constituents, including four phenylpropane derivatives and three lignans, were further quantified as marker substances, which showed good linearity within the test ranges. These results indicated that the developed quantitative method was linear, sensitive, and precise for quality control of ATS. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
The levels of urinary catecholamine metabolites, such as homovanillic acid (HVA) and vanillylmandelic acid, are routinely used as a clinical tool in the diagnosis and follow‐up of neuroblastoma (NB) patients. Recently, in the Clinical Pathology Laboratory Unit of G. Gaslini Children Hospital, a commercial method that employs liquid chromatography coupled to electrochemical detection (LC‐EC) has been introduced for the measurement of these metabolites in the routine laboratory practice. Using this LC‐EC method, an unknown peak could be observed only in samples derived from NB patients. To investigate the nature of this peak, we used a combination of liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS) and liquid chromatography‐ion trap tandem mass spectrometry (LC‐IT‐MS). The first approach was used to obtain the elemental composition of the ions present in this new signal. To get additional structural information useful for the elucidation of unknown compounds, the ion trap analyzer was exploited. We were able to identify not just one, but three unknown signals in urine samples from NB patients which corresponded to three conjugated products of HVA: HVA sulfate and two glucuronoconjugate isomers. The enzymatic hydrolysis with β‐glucuronidase confirmed the proposed structures, while the selective alkaline hydrolysis allowed us to distinguish the difference between phenol‐ and acyl‐glucuronide of HVA. The latter was the unknown peak observed in LC‐EC separations of urine samples from NB patients. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A sensitive and accurate LC–MS/MS method was established for quantifying bisabolangelone in rat plasma and tissues. Bisabolangelone was isolated and purified from Angelicae Pubescentis Radix. The pharmacokinetic and tissue distribution of bisabolangelone after administration to rat was performed by LC–MS/MS. Separation was carried out on a C8 (4.6 × 100 mm, 1.8 μm) column. The MS/MS transitions of bisabolangelone and tussilagone (internal standard) were set at m/z 249.1 → 109.1 and m/z 391.4 → 217.4, respectively. The lower limit of quantification in plasma and other tissues ranged from 1 to 4 ng/mL. The biosamples were prepared using protein precipitation method with acetonitrile. The recovery was >92%. The results showed that values of maximum concentrations and area under the curve depended linearly on the studied doses (2.5, 5 and 7.5 mg/kg body weight). The other ingredients in Angelicae Pubescentis Radix extract possibly reduce the absorption of bisabolangelone in rat. Tissue distribution revealed that bisabolangelone was widely distributed in vivo. The highest and lowest concentrations of bisabolangelone were found in the stomach and in the brain, respectively. It was concluded that the newly established HPLC–MS/MS method was suitable to describe the pharmacokinetic characteristics of bisabolangelone in rat after administration.  相似文献   

17.
A new analytical technique for the structural elucidation of four representative phenidate analogues possessing a secondary amine residue, which leads to a major/single amine‐representative fragment/product ion at m/z 84 both in their GC‐EI‐MS and LC‐ESI‐MS/MS spectra, making their identification ambiguous, was developed. The method is based on “in vial” chemical derivatization with isobutyl chloroformate in both aqueous and organic solutions, followed by liquid chromatography‐electrospray ionization mass spectrometry (LC‐ESI‐MS/MS). The resulting carbamate derivatives promote rich fragmentation patterns with full coverage of all substructures of the molecule, enabling detailed structural elucidation and unambiguous identification of the original compounds at low ng/mL levels.  相似文献   

18.
Lipopeptide biosurfactants produced by the Bacillus licheniformis V9T14 strain showed an interesting anti‐adhesion activity against biofilm formation of human pathogenic bacterial strains. The chemical characterisation of the crude extract of V9T14 strain was first developed through electrospray ionisation mass spectrometry (ESI‐MS) and ESI‐MS/MS direct infusions: two sets of molecular ion species belonging to the fengycin and surfactin families were revealed and their structures defined, interpreting their product ion spectra. The LC/ESI‐MS analysis of the crude extract allowed to separate in different chromatogram ranges the homologues and the isoforms of the two lipopeptide families. The extract was then fractionated by silica gel chromatography in two main fractions, I and II. The purified biosurfactants were analysed through a new, rapid and suitable LC/ESI‐MS/MS method, which allowed characterising the composition and the structures of the produced lipopeptides. LC/ESI‐MS/MS analysis of fraction I showed the presence of C13, C14 and C15 surfactin homologues, whose structures were confirmed by the product ion spectra of the sodiated molecules [M + Na]+ at m/z 1030, 1044 and 1058. LC/ESI‐MS/MS analysis of fraction II confirmed the presence of two main fengycin isoforms, with the protonated molecules [M + H]+ at m/z 1478 and 1506 corresponding to C17 fengycin A and C17 fengycin B, respectively. Other homologues (C14 to C16) were revealed and confirmed as belonging to fengycin A or B according to the retention times and the product ions generated, although with the same nominal mass. Finally, a relative percentage content of each homologue for both lipopeptides families in the whole extract was proposed. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
In this study, a new LC‐ESI‐MS/MS‐based method was validated for the quantitation of hemslecin A in rhesus monkey plasma using otophylloside A as internal standard (IS). Hemslecin A and the IS were extracted from rhesus monkey plasma using liquid–liquid extraction as the sample clean‐up procedure, and were subjected to chromatography on a Phenomenex Luna CN column (150 × 2.0 mm, 3.0 µm) with the mobile phase consisting of methanol and 0.02 mol/mL ammonium acetate (55:45, v/v) at a flow rate of 0.2 mL/min. Detection was performed on an Agilent G6410B tandem mass spectrometer by positive ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 580.5 [M + NH4]+ → 503.4 and m/z 518.2 [M + NH4]+ → 345.0 for hemslecin A and IS, respectively. The assay was linear over the concentration range of 0.5–200 ng/mL and was successfully applied to a pharmacokinetic study in rhesus monkeys. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
Ilaprazole is a new proton pump inhibitor designed for the treatment of gastric ulcers, and limited data is available on the metabolism of the drug. In this article, the structural elucidation of urinary metabolites of ilaprazole in human was described by HPLC‐ESI‐MS/MS and stopped‐flow HPLC‐NMR experiments. Urinary samples were precipitated by sodium carbonate solution, and then extracted by liquid–liquid extraction after adding ammonium acetate buffer solution. The enriched sample was separated using a C18 reversed‐phase column with the mobile phase composed of acetonitrile and 0.05 mol/L ammonium acetate buffer solution in a gradient solution, and then directly coupled to ESI‐MS/MS detection in an on‐line mode or 1H‐NMR (500 MHz) spectroscopic detection in a stopped‐flow mode. As a result, four sulfide metabolites, ilaprazole sulfide (M1), 12‐hydroxy‐ilaprazole sulfide (M2), 11,12‐dihydroxy‐ilaprazole sulfide (M3) and ilaprazole sulfide A (M4), were identified by comparing their MS/MS and NMR data with those of the parent drug and available standard compounds. The main biotransformation reactions of ilaprazole were reduction and the aromatic hydroxylation of the parent drug and its relative metabolites. The result testified that HPLC‐ESI‐MS/MS and HPLC‐NMR could be widely applied in detection and identification of novel metabolites. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号