首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
The present study investigates the performance of a multi-generation plant by integrating a parabolic dish solar collector to a steam turbine and absorption chiller producing electricity and process heat and cooling. Thermodynamic modeling of the proposed solar dish integrated multi-generation plant is conducted using engineering equation solver to investigate the effect of certain operating parameters on the performance of the integrated system. The performance of the solar integrated plant is evaluated and compared using three different heat transfer fluids, namely, supercritical carbon dioxide, pressurized water, and Therminol-VPI. The useful heat gain by collector is utilized to drive a Rankine cycle to evaluate the network output, rate of process heat, cooling capacity, overall energetic, and exergetic efficiencies as well as coefficient of performance. The results show that water is an efficient working fluid up to a temperature of 550 K, while Therminol-VPI performs better at elevated temperatures (630 K and above). Higher integrated efficiencies are linked with the lower inlet temperature and higher mass flow rates. The integrated system using pressurized water as a heat transfer fluid is capable of producing 1278 and 832 kW of power output and process heat, respectively, from input source of almost 6121 kW indicating overall energy and exergy efficiencies of 34.5% and 37.10%, respectively. Furthermore, multi-generation plant is evaluated to assess the exergy destruction rate and steam boiler is witnessed to have the major contribution of this loss followed by the turbine. The exergo-environmental analysis is carried out to evaluate the impact of the system on its surroundings. Exergo-environmental impact index, impact factor, impact coefficient, and impact improvement are evaluated against increase in the inlet temperature of the collector. The single-effect absorption cycle is observed to have the energetic and exergetic coefficient of performances of 0.86 and 0.422, for sCO2 operating system, respectively, with a cooling load of 228 kW.  相似文献   

2.
In this study, a new solar power assisted multigeneration system designed and thermodynamically analyzed. In this system, it is designed to perform heating, cooling, drying, hydrogen and power generation with a single energy input. The proposed study consists of seven sub-parts which are namely parabolic dish solar collector, Rankine cycle, organic Rankine cycle, PEM-electrolyzer, double effect absorption cooling, dryer and heat pump. The effects of varying reference temperature, solar irradiation, input and output pressure of high-pressure turbine and pinch point temperature heat recovery steam generator are investigated on the energetic and exergetic performance of integration system. Thermodynamic analysis result outputs show that the energy and exergy performance of overall study are computed as 48.19% and 43.57%, respectively. Moreover, the highest rate of irreversibility has the parabolic dish collector with 24,750 kW, while the lowest rate of irreversibility is calculated as 5745 kW in dryer. In addition, the main contribution of this study is that the solar-assisted multi-generation systems have good potential in terms of energy and exergy efficiency.  相似文献   

3.
In the present study, a new solar-based energy system for a self-sustained community is presented and analysed via the principles of thermodynamics. The presented system can meet the electricity demand, cooling load, and hydrogen (for the refueling of the vehicles) in a community by using a solar heliostat system (based on molten salt) in remote areas. Steam Rankine cycle is used to feed the electricity demand while some of the steam is bled out to operate the two-stage ammonia water-based absorption system for the cooling application. The result of the present study shows that with a heliostat area of 6000 m2, 372 kW of electricity, 610 kW of cooling capacity, and 7.2 kg/h of hydrogen is generated. Furthermore, exergy analysis results reveal that the maximum exergy destruction takes place in the central receiver (1170 kW) followed by heliostat (980 kW). The performance assessment of the overall presented system is made via exergy and energy efficiencies and estimated as 17.7%, and 38.9% respectively. Effects of some crucial parameters such as direct normal irradiance, evaporator temperature, the bleeding ratio, etc. have been studied on the overall system performance.  相似文献   

4.
In this article, a thermodynamic investigation of solar power tower assisted multigeneration system with hydrogen production and liquefaction is presented for more environmentally-benign multigenerational outputs. The proposed multigeneration system is consisted of mainly eight sub-systems, such as a solar power tower, a high temperature solid oxide steam electrolyzer, a steam Rankine cycle with two turbines, a hydrogen generation and liquefaction cycle, a quadruple effect absorption cooling process, a drying process, a membrane distillation unit and a domestic hot water tank to supply hydrogen, electrical power, heating, cooling, dry products, fresh and hot water generation for a community. The energetic and exergetic efficiencies for the performance of the present multigeneration system are found as 65.17% and 62.35%, respectively. Also, numerous operating conditions and parameters of the systems and their effects on the respective energy and exergy efficiencies are investigated, evaluated and discussed in this study. A parametric study is carried out to analyze the impact of various system design indicators on the sub-systems, exergy destruction rates and exergetic efficiencies and COPs. In addition, the impacts of varying the ambient temperature and solar radiation intensity on the irreversibility and exergetic performance for the present multigeneration system and its components are investigated and evaluated comparatively. According to the modeling results, the solar irradiation intensity is found to be the most influential parameter among other conditions and factors on system performance.  相似文献   

5.
Renewable energy-based hydrogen production plants can offer potential solutions to both ensuring sustainability in energy generation systems and designing environmentally friendly systems. In this combined work, a novel solar energy supported plant is proposed that can generate hydrogen, electricity, heating, cooling and hot water. With the suggested integrated plant, the potential of solar energy usage is increased for energy generation systems. The modeled integrated system generally consists of the solar power cycle, solid oxide fuel cell plant, gas turbine process, supercritical power plant, organic Rankine cycle, cooling cycle, hydrogen production and liquefaction plant, and hot water production sub-system. To conduct a comprehensive thermodynamic performance analysis of the suggested plant, the combined plant is modeled according to thermodynamic equilibrium equations. A performance assessment is also conducted to evaluate the impact of several plant indicators on performance characteristics of integrated system and its sub-parts. Hydrogen production rate in the suggested plant according to the performance analysis performed is realized as 0.0642 kg/s. While maximum exergy destruction rate is seen in the solar power plant with 8279 kW, the cooling plant has the lowest exergy destruction rate as 1098 kW. Also, the highest power generation is obtained from gas turbine cycle with 7053 kW. In addition, energetic and exergetic efficiencies of solar power based combined cycle are found as 56.48% and 54.06%, respectively.  相似文献   

6.
Fossil fuel-powered thermal desalination processes have many harmful environmental effects including greenhouse gas (GHG) emissions and high-salinity brine discharge resulting in biological damages, in addition to energy losses because of the high temperatures of the streams leaving the desalination unit. In this study, a solar energy-based polygeneration approach has been proposed to address these issues. In the proposed system, concentrated solar parabolic trough technology is used to drive a multi-stage flash (MSF) desalination unit for production of fresh water. To recover the waste heat carried by the produced clean water, an organic Rankine cycle is integrated to produce electricity. In addition, to recover the waste heat carried by brine, an absorption cooling system is employed to provide cooling. In order to mitigate the effects of high-salinity brine, a pressure retarded osmosis (PRO) unit is installed, which reduces the salinity of the discharge and produces additional electrical energy. To ensure stable nighttime operations, a thermal energy storage (TES) system is also added to the system. A comprehensive thermodynamic analysis is conducted through mass, energy, and entropy, as well as exergy balances along with energetic and exergetic efficiencies to assess the overall performance of the system. The attained results show that at reference conditions with an overall parabolic trough collectors (PTCs) area of 100 000 m2, the system produces 583.3 kW of electricity, approximately 4284 kW of cooling, and 1140 m3 of freshwater daily. Furthermore, the effects of changing operational conditions on the overall performance of the system are investigated. At design conditions, the overall energetic and exergetic efficiencies of the system are found to be 34.54% and 14.55%, respectively.  相似文献   

7.
In this paper, a combined power plant based on the dish collector and biomass gasifier has been designed to produce liquefied hydrogen and beneficial outputs. The proposed solar and biomass energy based combined power system consists of seven different subplants, such as solar power process, biomass gasification plant, gas turbine cycle, hydrogen generation and liquefaction system, Kalina cycle, organic Rankine cycle, and single-effect absorption plant with ejector. The main useful outputs from the combined plant include power, liquid hydrogen, heating-cooling, and hot water. To evaluate the efficiency of integrated solar energy plant, energetic and exergetic effectiveness of both the whole plant and the sub-plants are performed. For this solar and biomass gasification based combined plant, the generation rates for useful outputs covering the total electricity, cooling, heating and hydrogen, and hot water are obtained as nearly 3.9 MW, 6584 kW, 4206 kW, and 0.087 kg/s in the base design situations. The energy and exergy performances of the whole system are calculated as 51.93% and 47.14%. Also, the functional exergy of the whole system is calculated as 9.18% for the base working parameters. In addition to calculating thermodynamic efficiencies, a parametric plant is conducted to examine the impacts of reference temperature, solar radiation intensity, gasifier temperature, combustion temperature, compression ratio of Brayton cycle, inlet temperature of separator 2, organic Rankine cycle turbine and pump input temperature, and gas turbine input temperature on the combined plant performance.  相似文献   

8.
Parabolic dish solar collector system has capability to gain higher efficiency by converting solar radiations to thermal heat due to its higher concentration ratio. This paper examines the exergo-economic analysis, net work and hydrogen production rate by integrating the parabolic dish solar collector with two high temperature supercritical carbon dioxide (s-CO2) recompression Brayton cycles. Pressurized water (H2O) is used as a working fluid in the solar collector loop. The various input parameters (direct normal irradiance, ambient temperature, inlet temperature, turbine inlet temperature and minimum cycle temperature) are varied to analyze the effect on net power output, hydrogen production rate, integrated system energetic and exergetic efficiencies. The simulations has been carried out using engineering equation solver (EES). The outputs demonstrate that the net power output of the integrated reheat recompression s-CO2 Brayton system is 3177 kW, whereas, without reheat integrated system has almost 1800 kW net work output. The overall energetic and exergetic efficiencies of former system is 30.37% and 32.7%, respectively and almost 11.6% higher than the later system. The hydrogen production rate of the solarized reheat and without reheat integrated systems is 0.0125 g/sec and 0.007 g/sec, accordingly and it increases with rise in direct normal irradiance and ambient temperature. The receiver has the highest exergy destruction rate (nearly 44%) among the system components. The levelized electricity cost (LEC) of 0.2831 $/kWh with payback period of 9.5 years has proved the economic feasibility of the system design. The increase in plant life from 10 to 32 years with 8% interest rate will decrease the LEC from (0.434-0.266) $/kWh. Recuperators have more potential for improvement and their cost rate of exergy is higher as compared to the other components.  相似文献   

9.
In this paper we study an integrated PV/T absorption system for cooling and hydrogen production based on U.A.E weather data. Effect of average solar radiation for different months, operating time of the electrolyzer, air inlet temperature and area of the PV module on power and rate of heat production, energy and exergy efficiencies, hydrogen production and energetic and exergetic COPs are studied. It is found that the overall energy and exergy efficiency varies greatly from month to month because of the variation of solar radiation and the time for which it is available. The highest energy and exergy efficiencies are obtained for the month of March and their value is 15.6% and 7.9%, respectively. However, the hydrogen production is maximum for the month of August and its value is 9.7 kg because in august, the solar radiation is high and is available for almost 13 h daily. The maximum energetic and exergetic COPs are calculated to be 2.28 and 2.145, respectively and they are obtained in the month of June when solar radiation is high for the specified cooling load of 15 kW.  相似文献   

10.
In the present study, an innovative multigeneration plant for hydrogen and ammonia generation based on solar and biomass power sources is suggested. The proposed integrated system is designed with the integration of different subsystems that enable different useful products such as power and hydrogen to be obtained. Performance evaluation of designed plant is carried out using different techniques. The energetic and exergetic analyses are applied to investigate and model the integrated plant. The plant consists of the parabolic dish collector, biomass gasifier, PEM electrolyzer and hydrogen compressor unit, ammonia reactor and ammonia storage tank unit, Rankine cycle, ORC cycle, ejector cooling unit, dryer unit and hot water production unit. The biomass gasifier unit is operated to convert biomass to synthesis gaseous, and the concentrating solar power plant is utilized to harness the free solar power. In the proposed plant, the electricity is obtained by using the gas, Rankine and ORC turbines. Additionally, the plant generates compressed hydrogen, ammonia, cooling effect and hot water with a PEM electrolyzer and compressed plant, ammonia reactor, ejector process and clean-water heater, respectively. The plant total electrical energy output is calculated as 20,125 kW, while the plant energetic and exergetic effectiveness are 58.76% and 55.64%. Furthermore, the hydrogen and ammonia generation are found to be 0.0855 kg/s and 0.3336 kg/s.  相似文献   

11.
The present study develops a new solar and geothermal based integrated system, comprising absorption cooling system, organic Rankine cycle (ORC), a solar-driven system and hydrogen production units. The system is designed to generate six outputs namely, power, cooling, heating, drying air, hydrogen and domestic hot water. Geothermal power plants emit high amount of hydrogen sulfide (H2S). The presence of H2S in the air, water, soils and vegetation is one of the main environmental concerns for geothermal fields. In this paper, AMIS(AMIS® - acronym for “Abatement of Mercury and Hydrogen Sulphide” in Italian language) technology is used for abatement of mercury and producing of hydrogen from H2S. The present system is assessed both energetically and exergetically. In addition, the energetic and exergetic efficiencies and exergy destruction rates for the whole system and its parts are defined. The highest overall energy and exergy efficiencies are calculated to be 78.37% and 58.40% in the storing period, respectively. Furthermore, the effects of changing various system parameters on the energy and exergy efficiencies of the overall system and its subsystems are examined accordingly.  相似文献   

12.
This study deals with energy and exergy analysis of the experimental solar-assisted Rankine cycle working with an environmentally friendly working fluid transcritical CO2. The experimental system consists of evacuated solar collectors, a heat recovery system, condenser, a pump, and an expansion valve to simulate the realistic turbine operation. The system was designed for electricity production and the heat supply for various applications. The experiments were made funder typical winter and summer days to evaluate seasonal system performance in Kyoto, Japan. According to the obtained results, the turbine capacity was calculated as 0.118 kW and 0.177 kW for winter and summer seasons. From the exergetic point of view, solar collectors were found to be the major contributor to the total exergy destruction with 96.32% for summer and 93.58% for the winter season. Therefore, the efforts should be focused on the collectors. Thus, any attempt for improving the system performance should be focused on solar collectors first. Furthermore, the exergetic efficiency of the overall system was calculated as 7.63% for the winter season and 4.08% for the summer season. As a result, the utilization of CO2 in the energy conversion cycle can be sustainably developed and extended by providing a glimpse into the carbon-free clean energy future.  相似文献   

13.
In this paper, a solar power-based combined plant for power, hydrogen, methane, ammonia and urea production is proposed. A parabolic trough collector is utilized for the system prime mover. Moreover, steam Rankine cycle, organic Rankine cycle, hydrogen production and compression subsystem, ammonia, methane and urea production units, single-effect absorption cooling unit, and freshwater production plant are integrated together to develop the present system for better system performance and cost-effectiveness and reduced environmental impact. In order to analyze and evaluate the proposed multigeneration plant, thermodynamic, parametric and economic studies are performed. According to the assessment results, it is found that energetic and exergetic efficiencies of the present multigeneration plant are 66.12% and 61.56%, respectively. The comparisons of the subsystem and overall plant efficiencies show that the highest energetic and energetic efficiencies belong to freshwater production plant by 79.24% and 75.62%, respectively. In addition, the present parametric analysis indicates that an increase in the reference temperature, solar radiation intensity and working pressure of the solar process has a positive effect on the plant's performance. The cost analysis reveals that as the solar radiation intensity and the working pressure of the solar process increase, the hydrogen generation cost decreases. Furthermore, the hydrogen generation cost is achieved to be 1.94 $/kgH2 at 650 W/m2 of the solar radiation intensity, with other parameters remaining constant.  相似文献   

14.
Renewable energy based multi-generation systems can help solving energy-related environmental problems. For this purpose, a novel solar tower-based multi-generation system is proposed for the green hydrogen production as the main product. A solar-driven open Brayton cycle with intercooling, regeneration and reheat is coupled with a regenerative Rankine cycle and a Kalina cycle-11 as a unique series of power cycles. Significant portion of the produced electricity is utilized to produce green hydrogen in an electrolyzer. A thermal energy storage, a single-effect absorption refrigeration cycle and two domestic hot water heaters are also integrated. Energy, exergy and economic analyses are performed to examine the performance of the proposed system, and a detailed parametric analysis is conducted. Multiobjective optimization is carried out to determine the optimum performance. Optimum energy and exergy efficiencies, unit exergy product cost and total cost rate are calculated as 39.81%, 34.44%, 0.0798 $/kWh and 182.16 $/h, respectively. Products are 22.48 kg/h hydrogen, 1478 kW power, 225.5 kW cooling and 7.63 kg/s domestic hot water. Electrolyzer power size is found as one of the most critical decision variables. Solar subsystem has the largest exergy destruction. Regenerative Rankine cycle operates at the highest energy and exergy efficiencies among power cycles.  相似文献   

15.
In the examined paper, a solar and wind energy supported integrated cycle is designed to produce clean power and hydrogen with the basis of a sustainable and environmentally benign. The modeled study mainly comprises of four subsystems; a solar collector cycle which operates with Therminol VP1 working fluid, an organic Rankine cycle which runs with R744 fluid, a wind turbine as well as hydrogen generation and compression unit. The main target of this work is to investigate a thermodynamic evaluation of the integrated system based on the 1st and 2 nd laws of thermodynamics. Energetic and exergetic efficiencies, hydrogen and electricity generation rates, and irreversibility for the planned cycle and subsystems are investigated according to different parameters, for example, solar radiation flux, reference temperature, and wind speed. The obtained results demonstration that the whole energy and exergy performances of the modeled plant are 0.21 and 0.16. Additionally, the hydrogen generation rate is found as 0.001457 kg/s, and the highest irreversibility rate is shown in the heat exchanger subcomponents. Also, the net power production rate found to be 195.9 kW and 326.5 kW, respectively, with organic Rankine cycle and wind turbine. The final consequences obtained from this work show that the examined plant is an environmentally friendly option, which in terms of the system's performance and viable, for electrical power and hydrogen production using renewable energy sources.  相似文献   

16.
This paper investigates the performance of a high temperature Polymer Electrolyte Membrane (PEM) electrolyzer integrated with concentrating solar power (CSP) plant and thermal energy storage (TES) to produce hydrogen and electricity, concurrently. A finite-time-thermodynamic analysis is conducted to evaluate the performance of a PEM system integrated with a Rankine cycle based on the concept of exergy. The effects of solar intensity, electrolyzer current density and working temperature on the performance of the overall system are identified. A TES subsystem is utilized to facilitate continuous generation of hydrogen and electricity. The hydrogen and electricity generation efficiency and the exergy efficiency of the integrated system are 20.1% and 41.25%, respectively. When TES system supplies the required energy, the overall energy and exergy efficiencies decrease to 23.1% and 45%, respectively. The integration of PEM electrolyzer enhances the exergy efficiency of the Rankine cycle, considerably. However, it causes almost 5% exergy destruction in the integrated system due to conversion of electrical energy to hydrogen energy. Also, it is concluded that increase of working pressure and membrane thickness leads to higher cell voltage and lower electrolyzer efficiency. The results indicate that the integrated system is a promising technology to enhance the performance of concentrating solar power plants.  相似文献   

17.
In this article, an extensive thermodynamic performance assessment for the useful products from the solar tower and high-temperature steam electrolyzer assisted multigeneration system is performed, and also its sustainability index is also investigated. The system under study is considered for multi-purposes such as power, heating, cooling, drying productions, and also hydrogen generation and liquefaction. In this combined plant occurs of seven sub-systems; the solar tower, gas turbine cycle, high temperature steam electrolyzer, dryer process, heat pump, and absorption cooling system with single effect. In addition, the energy and exergy performance, irreversibility and sustainability index of multigeneration system are examined according to several factors, such as environment temperature, gas turbine input pressure, solar radiation and pinch point temperature of HRSG. Results of thermodynamic and sustainability assessments show that the total energetic and exergetic efficiency of suggested paper are calculated as 60.14%, 58.37%, respectively. The solar tower sub-system has the highest irreversibility with 18775 kW among the multigeneration system constituents. Solar radiation and pinch point temperature of HRSG are the most critical determinants affecting the system energetic and exergetic performances, and also hydrogen production rate. In addition, it has been concluded that, the sustainability index of multigeneration suggested study has changed between 2.2 and 3.05.  相似文献   

18.
A renewable energy based integrated system is developed to meet the total energy demands of a house located off-grid, and a thermodynamic analysis through energy and exergy methodologies is conducted for analysis, evaluation, and performance assessment. The present novel multigeneration system is mainly driven through the animal residues produced at the farm house. The proposed novel system is composed of nine main units namely, a biomass combustor, photovoltaic (PV) panels, parabolic solar trough collectors, thermoelectric generators, organic Rankine cycle, electrolyzer, homogeneous charged compression ignition (HCCI) engine, absorption chiller, and reverse osmosis (RO) unit. Biomass combustor runs an organic Rankine turbine for additional power during peak loads. The exhaust of gas turbine generates cooling to meet the cooling demand of the residential area of the farm house. PV panels are incorporated to generate hydrogen through electrolyzer. A HCCI engine generates power to compensate peak load as well as charging the farming vehicles of the farm house. The RO unit with energy recovery Pelton turbine produces fresh water for farming and residential use. The advanced integration of subsystems, thermoelectric generators and efficient utilization of waste, improves significant amount of energetic and exergetic efficiencies of overall multigenerational system. The energy and exergy efficiencies are enhanced in the order of 4.8% and 6.3%, respectively, after incorporating innovative cooling system to the PV modules. The overall energy and exergy efficiencies of the proposed multigeneration system with and without thermoelectric are found to be 67.6% and 57.1%, and 68.9% and 58.4%, respectively.  相似文献   

19.
In this study, an integrated multigeneration system that can produce hydrogen, electricity, heat, and methanol simultaneously is thermodynamically investigated. This integrated multigeneration system consists of three subsystems, namely: (i) electrolyzer, (ii) thermal power plant; and (iii) methanol production reactor. Energy and exergy analyses of all system components, as well as the sustainability analysis of the whole system, is performed thoroughly. The integrated system's thermodynamic performance is thoroughly investigated by changing some critical operational and environmental parameters in parametric studies. Based on the results of this study, recommendations for better energetic, exergetic, and environmental performance are presented for better sustainability. The results of this study show that the integrated multigeneration system is capable of producing hydrogen, heat, electricity, and methanol with overall energetic and exergetic efficiencies about 68% and 47%, respectively.  相似文献   

20.
This article presents the analytical evaluation of a central tower receiver solar thermal power plant with air‐cooled volumetric receiver using exergy analysis. The energetic and exergetic losses as well as the efficiencies of a typical central tower receiver‐based solar thermal power plant have been carried out under the specific operating conditions. The enhancement in efficiency of the plant from the variation in power input to constant power input achieved by thermal storage backup condition has been determined. It is found that the year round average energetic efficiency can be increased from 24.15% to 25.08% and year round average exergetic efficiency can be increased, from 26.10% to 27.10% for the selected location Jodhpur. The unit cost of electric energy generation (kWhe) is found to be INR 10.09 considering 30‐year lifespan of the solar plant along with a 10% interest rate. The present study provides a base for the development of future solar thermal power plants in India. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号