首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到3条相似文献,搜索用时 0 毫秒
1.
2.
The increasing popularity of multi‐player online games is leading to the widespread use of large‐scale Distributed Virtual Environments (DVEs) nowadays. In these systems, peer‐to‐peer (P2P) architectures have been proposed as an efficient and scalable solution for supporting massively multi‐player applications. However, the main challenge for P2P architectures consists of providing each avatar with updated information about which other avatars are its neighbors. This problem is known as the awareness problem. In this paper, we propose a comparative study of the performance provided by those awareness methods that are supposed to fully solve the awareness problem. This study is performed using well‐known performance metrics in distributed systems. Moreover, while the evaluations shown in the literature are performed by executing P2P simulations on a single (sequential) computer, this paper evaluates the performance of the considered methods on actually distributed systems. The evaluation results show that only a single method actually provides full awareness to avatars. This method also provides the best performance results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
Abstract— Two key metrics of image quality for high‐fidelity displays, including medical displays, are resolution and noise. Until now, these properties have been primarily measured in laboratory settings. For the first time, a system consisting of a CCD camera and analysis software has been made commercially available for measuring the resolution and noise of medical displays in a clinical setting. This study aimed at evaluating this new product in terms of accuracy and precision. In particular, the project involved the measurement of the modulation transfer function (MTF) and the signal‐to‐noise ratio (SNR) of two medical imaging displays, one cathode‐ray tube (CRT) display and one liquid‐crystal display (LCD) using this camera/software system. To assess the system's precision, measurements were made multiple times at the same setting. To check for accuracy, the results were compared with published values of the MTF and noise for the same displays. The performance of the system was also ascertained as a function of the focus setting of the camera. The results indicated that for the LCD, when the camera is focused within ±0.6 mm of the optimum focus setting, the MTF values lie within approximately 14% of the best focus MTF at the Nyquist frequency and 11% of the optimum overall sharpness (∫ MTF2 df). Similar results were obtained in the horizontal and vertical directions. For the CRT, this focus produced vertical and horizontal MTF values at the Nyquist frequency within 15.2% and 61.2% of the optimum focus MTF, respectively. The figures in terms of overall sharpness were 3.0% and 0.7%. The results for the noise measurements showed a repeatability of 3% for the LCD and 13% for the CRT and a relative (but not absolute) magnitude of the noise between the two displays reflective of prior measurements. Overall, the measurement system yielded reasonably precise resolution and noise results for both display devices. The accuracy was traceable to published results only for the MTF and for relative level of display noise with differences in the absolute magnitude of noise between current and prior measurements attributed to variations in the non‐standard techniques applied for display noise measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号