1.
制备了3种基于不同电活性物质(十二烷基二甲基苄基铵-四苯硼、十六烷基三甲基铵-四苯硼、十八烷基三甲基铵-四苯硼)的阳离子表面活性剂离子选择电极,并对其性能做了测定,结果显示该类电极对阳离子表面活性剂十二烷基二甲基苄基氯化铵、十六烷基三甲基溴化铵、十八烷基三甲基氯化铵均有能斯特响应。以此类电极作为指示电极,四苯硼钠溶液作为滴定剂,对阳离子表面活性剂(十二烷基二甲基苄基氯化铵、十八烷基三甲基氯化铵、海明1622)进行了活性物含量的测定,与两相滴定法测定结果进行了比较。  相似文献   

2.
This paper is aiming to give a brief overview of recent research in the field of all‐solid‐state, internal solution free, ion‐selective electrodes and reference electrodes, employing conducting polymers or nano‐/microstructures as solid contacts beneath the polymeric, ion‐selective or reference membranes. The emphasis is on papers published in the last five years (after 2006). According to the papers published, poly(3‐octylthiophene) conducting polymer transducers offer highly reliable sensors for various applications, involving demanding analytical approaches and miniature sensors. On the other hand, the search for alternative materials continues: the sensors obtained by placing nano‐/microstructures (conducting polymers but also other materials, like, e.g., carbon nanotubes) underneath the receptor membrane are intensively tested. The recent years have also shown how useful the application of advanced instrumental methods is for the investigation of processes occurring within all‐solid‐state ion‐selective electrodes.  相似文献   

3.
Ion‐selective electrodes play an important role in pharmaceutical analysis due to their simplicity, rapidity and accuracy over some other analytical methods. This research introduces the design of an ion‐pair of imipramine‐tetraphenyl borate (IMP‐TPB) based PVC membrane sensor for IMP hydrochloride determination. Effect of the membrane composition, the pH influence and the effect of lipophilic anionic additives on the response characteristics of the electrode were investigated. After a series of experiments, the best electrode performance was accomplished with a membrane composition of 30% PVC, 63% DBP, 5% (IMP‐TPB) and 2% (NaTPB). This electrode illustrated a fast (15 s), stable and Nernstian response across a relatively wide IMP hydrochloride concentration range (10?5 to 10?5 M), in the pH range of (3.0–8.0), and it can be used for at least two months without any measurable change in sensitivity. Additionally, the interference between IMP and several drugs and common inorganic anions was negligible as shown by the potentiometric selectivity coefficient data. The membrane sensor was successfully applied to the determination of IMP in tablets and human urine samples, and very good recovery results were obtained.  相似文献   

4.
《Electroanalysis》2006,18(1):7-18
Conducting polymers, i.e., electroactive conjugated polymers, are useful both as ion‐to‐electron transducers and as sensing membranes in solid‐state ion‐selective electrodes. Recent achievements over the last few years have resulted in significant improvements of the analytical performance of solid‐contact ion‐selective electrodes (solid‐contact ISEs) based on conducting polymers as ion‐to‐electron transducer combined with polymeric ion‐selective membranes. A significant amount of research has also been devoted to solid‐state ISEs based on conducting polymers as the sensing membrane. This review gives a brief summary of the progress in the area in recent years.  相似文献   

5.
《Electroanalysis》2006,18(8):763-771
A novel concept of tailoring potentiometric responses of all‐solid‐state ion‐selective electrodes was introduced. The effect of composition and resulting properties of the conjugated polymer transducer, placed between the electrode support and ion‐selective membrane, on analytical characteristic of obtained sensors was studied.  相似文献   

6.
7.
《Electroanalysis》2003,15(20):1598-1605
It is well known that non‐ionic surfactants (NIS) influence remarkably the potentiometric measurements with liquid membrane ion selective electrodes (ISEs), interfering particularly on performance of ISEs for earth‐alkali metals, for which the loss of selectivity with regard to alkali metals has been documented. These studies indicate that such interferences are due to the extraction of surfactants within the membrane, where a competition takes place between the originally present ionophore and the surfactant which also acts as a ligand for alkali metals. The interpretation of such phenomena enabled one to exploit this interference for analytical purposes by membrane/solution extraction experiment monitored by UV measurements and by impedance FRA analysis on coated wire electrodes. Using Ca/Mg ISEs based on the neutral ionophore ETH 4030, it has been established that the logarithm of the Ca/Mg over Na potentiometric selectivity constant is linearly correlated with the concentration of NIS like Tegopren 5863 and Triton X‐100. The proposed method has been applied for the development of a new potentiometric analytical procedure for the determination of Tegopren 5863 in synthetic seawater (SSW), ranging from 0.25 to 5 ppm. Our procedure consists in the exposure of the electrode to stirred SSW containing the surfactant; the progressive extraction of Tegopren 5863 causes a growth in electrode's sensitivity to Na+ and K+, losing selectivity for Ca2+ and Mg2+. In turn this induces an increase of EMF, as all these ions are present in the studied matrix. The potential drift was monitored for 15 hours, showing that the process reaches thermodynamic equilibrium after about 12 hours of exposure. This method presents a value of 210 ppb of Tegopren 5863 as detection limit.  相似文献   

8.
A potentiometric sensor for studying charge based adsorption of proteins was created using a single‐piece polyaniline‐PVC ion‐selective electrode (ISE). Three different ISEs, two for Na+ and one for Cl? ion determination, were studied. The Na+‐ISEs consisted of a neutral calixarene‐based ionophore and one with a charged carrier dinonylnapthalenesulfonic acid (DNNSA) whereas for the Cl? ISE, an anion exchanger tridodecylmethylammonium chloride (TDDMA+Cl?), was used. The Na+ ISE with DNNSA as the charged carrier was successfully able to discriminate the binding of two different proteins (bovine serum albumin and lysozyme) based on their intrinsic charge.  相似文献   

9.
Preliminary studies on the two Schiff bases N2‐((3H‐indol‐3‐yl)methylene)‐6‐phenyl‐1,3,5‐triazine‐2,4‐diamine (L1) and N2,N4‐bis((3H‐indol‐3‐yl)methylene)‐6‐phenyl‐1,3,5‐triazine‐2,4‐diamine (L2) have shown that they can act as Sm3+ selective electrodes. The performances of a polymeric membrane electrode and a coated graphite electrode based on L2 were compared and the CGE proved to be better, as it shows a low detection limit of 1.8×10?8 mol L?1, a Nernstian slope of 19.6±0.4 mV decade?1 of activity with a response time of 11 s in the pH range of 3.0–9.0. The CGE was used to determine Sm3+ in medicinal plants and soil samples. It was also used to determine fluoride ions in mouthwash samples and in toothpaste.  相似文献   

10.
Pankaj Kumar 《Electroanalysis》2012,24(10):2005-2012
A new ionophore, i.e. p‐(2‐thiazolazo)calix[4]arene ( I ) has been explored for its selective behavior towards Ni(II) ions. A poly(vinyl chloride) based membrane containing ( I ) as an electroactive material along with sodiumtetraphenylborate (NaTPB), and nitrophenyloctyl ether in the ratio 10 : 100 : 3 : 150 (I:PVC:NaTPB:NPOE) (w/w) was used to fabricate an all solid state nickel(II)‐selective sensor. The developed sensor exhibited a working concentration range of 1.0×10?6–1.0×10?1 M, with a Nernstian slope of 28.9±1.0 mV/decade of activity and a response time of 10–15 s. This sensor shows a detection limit of 9.0×10?7 M. Its potential response remains unaffected of pH in the range 3.0–7.6, and the cell assembly could be used successfully in partially nonaqueous medium (up to 10 % v/v) without any significant change in the slope value or the working concentration range. The sensor worked satisfactorily for about ten weeks and exhibited excellent selectivity over a number of mono‐, bi‐, and tri‐valent cations including alkali, alkaline earth metal, and transition metal ions. It could be used as an indicator electrode for the end point determination in the potentiometric titration of nickel ions against ethylenediaminetetraacetic acid (EDTA) as well as for the determination of nickel ion concentration in real samples.  相似文献   

11.
Three types of ion‐selective electrodes: PVC membrane, modified carbon paste (CPE), and coated graphite electrodes (CGE) have been constructed for determining paroxetine hydrochloride (Prx). The electrodes are based on the ion pair of paroxetine with sodium tetraphenylborate (NaTPB) using dibutyl phthalate as plasticizing solvent. Fast, stable and potentiometric response was obtained over the concentration range of 1.1×10?5–1×10?2 mol L?1 with low detection limit of 6.9×10?6 mol L?1 and slope of a 56.7±0.3mV decade?1 for PVC membrane electrode, the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 1.2×10?5 mol L?1 and slope of a 57.7±0.6 mV decade?1 for CPE, and the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 8.9×10?6 mol L?1 and slope of a 56.1±0.1 mV decade?1 for CGE. The proposed electrodes display good selectivity for paroxetine with respect to a number of common inorganic and organic species. The electrodes were successfully applied to the potentiometric determination of paroxetine hydrochloride in its pure state, its pharmaceutical preparation, human urine and plasma.  相似文献   

12.
A new podand of 1,1′‐thia‐bis‐[1‐(chloroethan‐2‐acetamid‐α‐oxy)] naphtol was synthesized and used as a suitable carrier for Ag+ PVC membrane electrode. The electrode exhibited linear response with a Nernstian slope of (59.5±0.8 mV/decade) within a wide concentration range of 1.0×10?7 to 1.5×10?2 mol L?1 silver ions. The electrode had a fast response time of <10 s and detection limit of 8.6×10?8 mol L?1 with a working pH range from 3.7 to 9.0. The electrode was highly selective for Ag(I) ions over a large number of cations such as alkali, alkaline earth, and heavy metal ions. The proposed sensor has been applied as an indicator electrode for indirect determination of vitamin B1 in tablets by determination of Cl? ions in this compound with a standard solution of Ag(NO3).  相似文献   

13.
《Electroanalysis》2005,17(4):348-355
An array of eight nonspecific potentiometric sensors was used in combination with multivariate calibration for the simultaneous determination of NH , K+ and Na+ ions. The sensors were of the all‐solid‐state type and employed a PVC polymer membrane. Signals were processed by using a multilayer artificial neural network (ANN). The ANN configuration used was optimized by using 8 neurons in the input layer, 5 in the hidden layer and 3 in the output layer. Use of the Bayesian Regularization algorithm allowed a quick building of an accurate model, as confirmed by random multi‐starting of network weights. The system was used to analyze synthetic and river water, waste water and fertilizer samples. Correct results were obtained for the three ions in synthetic and real water samples; in fertilizers, ammonium ion can be determined, while sodium and potassium show biased results.  相似文献   

14.
A novel potentiometric sensor based on screen‐printed carbon electrode covered with electropolymerized polyaniline (PANI) and unsubstituted pillar[5]arene as ionophore has been developed and tested in potentiometric measurements of pH and metal ions. The introduction of pillar[5]arene improved the reversibility of the pH response in the range from 2.0 to 9.0 with the slope of 45 mV/pH. Among metal cations, the response to Fe3+ and Ag+ ions was referred to PANI redox conversion whereas the signal toward Cu2+ in the range from 1.0×10?6 to 1.0×10?2 M (limit of detection (LOD) 3.0×10?7 M) to specific interaction with the macrocycle.  相似文献   

15.
The design and properties of novel type of solid‐contact ionophore‐based ion‐selective microelectrodes are reported. The microelectrode is based on an insulated needle‐shaped metallic wire with an exposed apex. The ion‐to‐electron transducer is made of poly(3‐octylthiophene‐2,5‐diyl) and placed between an ion‐selective membrane and the metallic tip. The ion‐selective polyvinyl chloride‐based membrane is deposited atop the layer of conductive polymer. The length of the ion‐sensitive part of the electrode is less than 10 μm. pH and Mg2+‐selective microelectrodes were constructed and tested showing stable potential and fast response that are essential properties for the practical application of microelectrodes for localized scanning measurements.  相似文献   

16.
The increase use of ion sensors in the fields of environmental, agricultural, and medical analysis is stimulating analytical chemists to develop new sensors for fast, accurate, reproducible, and selective determination of various ions. In this study a new samarium membrane sensor was constructed and for the first time, it was applied as a probe in indirect determination of hyoscine, homatropine, and tramadol drugs in their pharmaceutical formulation. The proposed membrane sensor was constructed based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 63% dibutyl phthalate (DBP) as solvent mediator, 5% ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Sm(III) electrode exhibits a Nernstian response of 19.35±0.2 mV per decade of samarium concentration, and has a lower detection limit of 1.0×10?7 M. The linear range of the sensors was 1.0×10?7–1.0×10?1 M. It works well in the pH range of 3.0–8.0.  相似文献   

17.
Multi‐walled carbon nanotubes (MWCNTs) were compared with poly(3‐octylthiophene) (POT) as ion‐to‐electron transducer in all‐solid‐state potassium ion‐selective electrodes with valinomycin‐based ion‐selective membranes. MWCNTs and POT were mixed with the other components of the potassium ion‐selective membrane cocktail (valinomycin, KTpClPB, o‐NPOE, PVC, THF) which was then applied on a glassy carbon (GC) substrate to prepare single‐piece ion‐selective electrodes (SPISEs). Results from potentiometric and impedance measurements showed that the MWCNT‐based electrodes have a more reproducuible standard potential and a lower overall impedance than the electrodes based on POT. Both types of electrodes showed similar sensitivity to potassium ions and no redox sensitivity.  相似文献   

18.
A single‐piece solid‐contact Pb2+‐selective electrode was prepared by adding a thiophene oligomer into the ion‐selective cocktail directly. The one‐step fabrication yielded an electrode with Nernstian response spanning a wide concentration range of 10?3–10?8 mol L?1, and detection limit as low as 5.6×10?9 mol L?1. The electrode had a quick response time of approximately 10–15 s and showed excellent selectivity over the most common univalent and divalent cations. The practical application of the proposed electrode has been tested by determining Pb2+ in real water samples.  相似文献   

19.
A new chemically modified carbon paste electrode based on a mixture of two ion‐exchangers namely chlorpheniramine‐silicotungstate (CPM‐ST) and chlorpheniramine‐tetraphenylborate (CPM‐TPB) as ion‐exchange site for determination of chlorpheniramine maleate (CPM) was described. The best performance was exhibited by the electrode having the paste containing 3.0 wt% ion‐exchangers (CPM‐ST&CPM‐TPB), 48.5 wt% graphite, 47.5 wt% DOPh and 1.0 wt% NaTPB. The proposed chemically modified carbon paste electrode exhibited a Nernstian response for CPM over a wide concentration range of 1.2×10?6 to 1.0×10?2 M with a detection limit of 5.1×10?7 M between pH 4.5 and 7.7 with fast response ≤10 s. The sensor showed good selectivity for CPM with respect to a large number of inorganic cations, organic cations, sugars, amino acids and some common drug excipients. The modified electrode was applied to potentiometric determination of CPM in its pharmaceutical preparations and biological fluids (serum and urine) with average recoveries of 97.5–102% and relative standard deviations of 0.32–1.97%.  相似文献   

20.
New polymeric membrane cadmium‐ion selective sensors have been prepared by incorporating nitrogen and sulfur containing tridentate ligands as the ionophores into the plasticized PVC membranes. Poly(vinyl chloride) (PVC) based membranes of potassium hydrotris[N‐(2,6‐xylyl)thioimdazolyl) borate] (KTt2,6‐xylyl) and potassium hydrotris(3‐phenyl‐5‐methylpyrazolyl) borate (KTpPh,Me) with sodium tetraphenyl borate (NaTPB) as an anionic excluder and dibutylphthalate (DBP), tributylphthalate (TBP), dioctylsebacate (DOS), and o‐nitrophenyloctyl ether (o‐NPOE) as plasticizing solvent mediators were investigated in different compositions. KTt2,6‐xylyl was found to be a selective and sensitive ion carrier for Cd(II) membrane sensor. A membrane composed of KTt2,6‐xylyl:NaTPB:PVC:DBP with the % mole ratio 2.3 : 1.1 : 34.8 : 61.8 (w/w) works well over a very wide concentration range (7.8×10?8–1.0×10?2 M) with a Nernstian slope of 29.4±0.2 mV/decades of activity between pH values of 3.5 to 9.0 with a detection limit of 4.37×10?8 M. The sensor displays very good discrimination toward Cd(II) ions with regard to most common cations. The proposed sensor shows a short response time for whole concentration range (ca. 8 s). The effects of the cationic (tetrabutylammonium chloride, TBC), anionic (sodium dodecyl sulfate, SDS) and nonionic (Triton X‐100) surfactants were investigated on the potentiometric properties of proposed cadmium‐selective sensor. The proposed sensor based on KTt2,6‐xylyl ionophore has also been used for the direct determination of cadmium ions in different water samples and human urine samples.  相似文献   