首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents a simultaneous optimization procedure for both viscoelastic dampers (VEDs) and supporting braces installed in a structure. The effect of supporting braces on the control efficiency of VEDs is also investigated. To apply a general gradient‐based optimization algorithm, closed‐form expressions for the gradients of objective function and constraints are derived. Also, the constraint on the dynamic behavior of a structure is embedded in the gradient computation procedure to reduce the number of variables in the optimization. From numerical analysis of an example structure, it was found that when sufficient stiffness cannot be provided for the supporting braces, the flexibility of the brace should be taken into account in the design of the VED to achieve the desired performance of the structure. It was also observed that, as a result of the proposed optimization process, the size of the supporting brace could be reduced while the additional VED size (to compensate for the loss of the control effect) was insignificant. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
The effectiveness of viscous and viscoelastic dampers for seismic response reduction of structures is quite well known in the earthquake engineering community. This paper deals with the optimal utilization of these dampers in a structure to achieve a desired performance under earthquake‐induced ground excitations. Frequency‐dependent and ‐independent viscous dampers and viscoelastic dampers have been considered as the devices of choice. To determine the optimal size and location of these dampers in the structure, a genetic algorithm is used. The desired performance is defined in terms of several different forms of performance functions. The use of the genetic approach is not limited to any particular form of performance function as long as it can be calculated numerically. For illustration, numerical examples for different building structures are presented showing the distribution and size of different dampers required to achieve a desired level of reduction in the response or a performance index. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

3.
The insertion of steel braces equipped with viscoelastic dampers (VEDs) (‘dissipative braces’) is a very effective technique to improve the seismic or wind behaviour of framed buildings. The main purpose of this work is to compare the earthquake and wind dynamic response of steel‐framed buildings with VEDs and achieve optimal properties of dampers and supporting braces. To this end, a numerical investigation is carried out with reference to the steel K‐braced framed structure of a 15‐storey office building, which is designed according to the provisions of Eurocodes 1 and 3, and to four structures derived from the first one by the insertion of additional diagonal braces and/or VEDs. With regard to the VEDs, the following cases are examined: absence of dampers; insertion of dampers supported by the existing K‐braces in each of the structures with or without additional diagonal braces; insertion of dampers supported by additional diagonal braces. Dynamic analyses are carried out in the time domain using a step‐by‐step initial stress‐like iterative procedure. For this purpose, the frame members and the VEDs are idealized, respectively, by a bilinear model, which allows the simulation of the nonlinear behaviour under seismic loads, and a six‐element generalized model, which can be considered as an in‐parallel‐combination of two Maxwell models and one Kelvin model. Artificially generated accelerograms, whose response spectra match those adopted by Eurocode 8 for a medium subsoil class and for different levels of peak ground acceleration, are considered to simulate seismic loads. Along‐wind loads are considered assuming, at each storey, time histories of the wind velocity for a return period Tr=5 years, according to an equivalent spectrum technique. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
A methodology for the optimal design of supplemental viscous dampers for framed structures is presented. It addresses the problem of minimizing the added damping subject to a constraint on the maximal interstorey angular drift for an ensemble of realistic ground motion records while assuming linear behaviour of the damped structure. The solution is achieved by actually solving an equivalent optimization problem of minimizing the added damping subject to a constraint on a maximal weighted integral on the squared angular drift. The computational effort is appreciably reduced by first using one ‘active’ ground motion record. If the resulting optimal design fails to satisfy the constraints for other ground motions from the original ensemble, additional ground motions (loading conditions) are added one by one to the ‘active’ set until the optimum is reached. An efficient selecting process which is presented herein will usually require one or two records to attain an optimum design. Examples of optimal designs of supplemental dampers are presented for a 2‐storey shear frame and a 10‐storey industrial frame. The 2‐storey shear frame is required to withstand one given ground motion whereas the 10‐storey frame is required to withstand an ensemble of twenty ground motions. The resulting viscously damped structures have envelope values of interstorey drifts equal or less than the target drifts. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
针对工程中的实际需要,提出一些新型的粘弹性消能支撑型式,分析了它们的受力特点,推导了消能支撑变形的表达式,并给出了其控制力的计算公式;最后,研究了影响结构消能效果的设计参数,给出了设计参数合理的取值范围。  相似文献   

6.
本文将调谐液体阻尼器(TLD)和黏弹性阻尼器(VED)同时作用于结构,构成混合被动控制系统。通过对两类阻尼器分别进行优化设计并考虑两者间的相互影响,在充分发挥两者各自优良控制性能的同时,克服了VED大量使用导致控制系统整体造价过高的问题。算例分析表明,混合控制可以得到令人满意的整体减震效果,同时大大节约了VED用量,提高了控制系统的综合经济性能。  相似文献   

7.
In conventional modal analysis procedures, usually only a few dominant modes are required to describe the dynamic behavior of multi-degrees-of-freedom buildings. The number of modes needed in the dynamic analysis depends on the higher-mode contribution to the structural response, which is called the higher-mode effect. The modal analysis approach, however, may not be directly applied to the dynamic analysis of viscoelastically damped buildings. This is because the dynamic properties of the viscoelastic dampers depend on their vibration frequency. Therefore, the structural stiffness and damping contributed from those dampers would be different for each mode. In this study, the higher-mode effect is referred to as the response difference induced by the frequency-dependent property of viscoelastic dampers at higher modes. Modal analysis procedures for buildings with viscoelastic dampers distributed proportionally and non-proportionally to the stiffness of the buildings are developed to consider the higher-mode effect. Numerical studies on shear-type viscoelastically damped building models are conducted to examine the accuracy of the proposed procedures and to investigate the significance of the higher-mode effect on their seismic response. Two damper models are used to estimate the peak damper forces in the proposed procedures. Study results reveal that the higher-mode effect is significant for long-period viscoelastically damped buildings. The higher-mode effect on base shear is less significant than on story acceleration response. Maximum difference of the seismic response usually occurs at the top story. Also, the higher-mode effect may not be reduced by decreasing the damping ratio provided by the viscoelastic dampers. For practical application, it is realized that the linear viscous damping model without considering the higher-mode effect may predict larger damper forces and hence, is on the conservative side. Supported by: Science Council, Chinese Taipei, grant no. 88-2625-2-002-006  相似文献   

8.
Vibration control systems are being used increasingly worldwide to provide enhanced seismic protection for new and retrofitted buildings. This paper presents a new vibration control system on the basis of a seesaw mechanism with viscoelastic dampers. The proposed vibration control system comprises three parts: brace, seesaw member, and viscoelastic dampers. In this system, only tensile force appears in bracing members. Consequently, the brace buckling problem is negligible, which enables the use of steel rods for bracing members. By introducing pre‐tension in rods, long steel rods are applicable as bracing between the seesaw members and the moment frame connections over some stories. Seesaw mechanisms can magnify the damper deformation according to the damper system configuration. In this paper, first, the magnification factor, that is, the ratio of the damper deformation to the story drift, is delivered, which includes the rod deformation. Results of a case study demonstrate that the magnification factor of the proposed system is greater than unity for some cases. Seismic response analysis is conducted for steel moment frames with the proposed vibration control system. Energy dissipation characteristics are examined using the time‐history response results of energy. The maximum story drift angle distributions and time‐history response results of displacement show that the proposed system can reduce the seismic response of the frames effectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Investigated is the accuracy in estimating the response of asymmetric one‐storey systems with non‐linear viscoelastic (VE) dampers by analysing the corresponding linear viscous system wherein all non‐linear VE dampers are replaced by their energy‐equivalent linear viscous dampers. The response of the corresponding linear viscous system is determined by response history analysis (RHA) and by response spectrum analysis (RSA) extended for non‐classically damped systems. The flexible and stiff edge deformations and plan rotation of the corresponding linear viscous system determined by the extended RSA procedure is shown to be sufficiently accurate for design applications with errors generally between 10 and 20%. Although similar accuracy is also shown for the ‘pseudo‐velocity’ of non‐linear VE dampers, the peak force of the non‐linear VE damper cannot be estimated directly from the peak damper force of the corresponding linear viscous system. A simple correction for damper force is proposed and shown to be accurate (with errors not exceeding 15%). For practical applications, an iterative linear analysis procedure is developed for determining the amplitude‐ and frequency‐dependent supplemental damping properties of the corresponding linear viscous system and for estimating the response of asymmetric one‐storey systems with non‐linear VE dampers from the earthquake design (or response) spectrum. Finally, a procedure is developed for designing non‐linear supplemental damping systems that satisfy given design criteria for a given design spectrum. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
根据黏弹性阻尼器的特点和抗震规范的要求,分别提出了用于黏弹性阻尼器减震结构抗震分析的弹性及弹塑性需求谱,前者是基于黏弹性阻尼器减震结构等效阻尼比的简化计算公式及规范规定的反应谱;后者是基于修正的V id icRμ-μ-T关系。在此基础上,借助模态推覆分析,提出了可以考虑高阶振型影响的黏弹性阻尼器消能减震结构体系的能力谱分析方法,并对一8层钢筋混凝土消能减震框架结构进行了"中震不坏,大震可修"性能水准下的抗震分析。算例结果表明,采用该方法分析黏弹性阻尼器减震结构体系是可行的、有效的。  相似文献   

11.
Investigated are earthquake responses of one‐way symmetric‐plan, one‐storey systems with non‐linear fluid viscous dampers (FVDs) attached in series to a linear brace (i.e. Chevron or inverted V‐shape braces).Thus, the non‐linear damper is viscous when the brace is considered rigid or viscoelastic (VE) when the brace is flexible. The energy dissipation capacity of a non‐linear FVD is characterized by an amplitude‐dependent damping ratio for an energy‐equivalent linear FVD, which is determined assuming the damper undergoes harmonic motion. Although this formulation is shown to be advantageous for single‐degree‐of‐freedom (SDF) systems, it is difficult to extend its application to multi‐degree‐of‐freedom (MDF) systems for two reasons: (1) the assumption that dampers undergo harmonic motion in parameterizing the non‐linear damper is not valid for its earthquake‐induced motion of an MDF system; and (2) ensuring simultaneous convergence of all unknown amplitudes of dampers is difficult in an iterative solution of the non‐linear system. To date, these limitations have precluded the parametric study of the dynamics of MDF systems with non‐linear viscous or VE dampers. However, they are overcome in this investigation using concepts of modal analysis because the system is weakly non‐linear due to supplemental damping. It is found that structural response is only weakly affected by damper non‐linearity and is increased by a small amount due to bracing flexibility. Thus, the effectiveness of supplemental damping in reducing structural responses and its dependence on the planwise distribution of non‐linear VE dampers were found to be similar to that of linear FVDs documented elsewhere. As expected, non‐linear viscous and VE dampers achieve essentially the same reduction in response but with much smaller damper force compared to linear dampers. Finally, the findings in this investigation indicate that the earthquake response of the asymmetric systems with non‐linear viscous or VE dampers can be estimated with sufficient accuracy for design applications by analysing the same asymmetric systems with all non‐linear dampers replaced by energy‐equivalent linear viscous dampers. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
A new method to design multiple tuned mass dampers (multiple TMDs) for minimizing excessive vibration of structures has been developed using a numerical optimizer. It is a very powerful method by which a large number of design variables can be effectively handled without imposing any restriction before the analysis. Its framework is highly flexible and can be easily extended to general structures with different combinations of loading conditions and target controlled quantities. The method has been used to design multiple TMDs for SDOF structures subjected to wide‐band excitation. Some novel results have been obtained. To reduce displacement response of the structure, the optimally designed multiple TMDs have distributed natural frequencies and distinct damping ratios at low damping level. The obtained optimal configuration of TMDs was different from the earlier analytical solutions and was proved to be the most effective. A robustness design of multiple TMDs has also been presented. Robustness is defined as the ability of TMDs to function properly despite the presence of uncertainties in the parameters of the system. Numerical examples of minimizing acceleration structural response have been given where the system parameters are uncertain and are modeled as independent normal variates. It was found that, in case of uncertainties in the structural properties, increasing the TMD damping ratios along with expanding the TMD frequency range make the system more robust. Meanwhile, if TMD parameters themselves are uncertain, it is necessary to design TMDs for higher damping ratios and a narrower frequency range. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

13.
阻尼器参数的确定是利用阻尼器连接相邻结构进行减震设计的关键.根据随机地震反应理论,以相邻结构的频率比和质量比为参数,推导了结构位移反应均方差与连接阻尼比的关系式,得到了相邻结构的地震反应与频率比、质量比以及连接阻尼比的影响规律,从而得到了连接阻尼器的优化设计参数.根据自振频率相等的原则,探讨了将多自由度体系简化为单自由度体系的分析方法.最后在El Centro波、Taft 波及人工波激励下,对比分析了某相邻10层建筑结构有连接和无连接时的地震反应,表明黏滞阻尼器连接相邻结构具有较好的减震效果.本分析方法可供相邻结构减震设计参考.  相似文献   

14.
黏滞阻尼器在单层网壳结构中的优化布置   总被引:1,自引:0,他引:1  
目前采用黏滞阻尼器对单层网壳结构进行减振控制时,阻尼器最优布置位置通过试算确定。针对此问题,推导了地震作用下黏滞阻尼器耗能公式,提出了以能量比例系数为评价指标的阻尼器优化布置准则。以单层球面网壳和单层柱面网壳为例,对比分析了地震作用下分别采用优化布置准则与现有布置方式布置阻尼器时结构最大节点位移减振系数,验证了所提出优化布置准则的正确性及在单层球面网壳和单层柱面网壳中的适用性。  相似文献   

15.
A simplified design procedure (SDP) for preliminary seismic design of frame buildings with structural dampers is presented. The SDP uses elastic‐static analysis and is applicable to structural dampers made from viscoelastic (VE) or high‐damping elastomeric materials. The behaviour of typical VE materials and high‐damping elastomeric materials is often non‐linear, and the SDP idealizes these materials as linear VE materials. With this idealization, structures with VE or high‐damping elastomeric dampers can be designed and analysed using methods based on linear VE theory. As an example, a retrofit design for a typical non‐ductile reinforced concrete (RC) frame building using high‐damping elastomeric dampers is developed using the SDP. To validate the SDP, results from non‐linear dynamic time history analyses (NDTHA) are presented. Results from NDTHA demonstrate that the SDP estimates the seismic response with sufficient accuracy for design. It is shown that a non‐ductile RC frame building can be retrofit with high‐damping elastomeric dampers to remain essentially elastic under the design basis earthquake (DBE). Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

16.
减震结构中的粘弹性阻尼器参数优化   总被引:14,自引:0,他引:14  
研究了粘弹性阻尼器在结构减震控制中的参数优化问题。从性价比的角度提出r优化目标函数,建立了阻尼器的参数优化模型。以一单层框架为例,分别选用非线性规划中的复形法和通过调用MATLAB程序优化工具箱中Fmincon函数(简称Fmincon函数法)两种方法,编制丁相应的优化分析程序,对粘弹性阻尼器在单层框架结构减震控制中的参数优化进行丁分析。研究结果表明,两种优化算法都达到了预期的目标,实现了目标函数最小化。  相似文献   

17.
A method for design of an active control system for multistorey structures using Electrorheological (ER) dampers is presented. Incorporated at various levels of a structural frame, ER dampers are used to improve the response of the structure during earthquakes. Optimal control theory was used to design the ER devices. The aim of the design is to find the most suitable combination of the minimum required forces produced by the ER dampers to obtain the optimal structural response. The mechanical response of ER fluid dampers is regulated by an electric field, depending on the displacements and velocities of the frame. Numerical analysis of an ER damped seven-storey structure is represented as an example. Significant improvement of the structural response was obtained using optimal active controlled ER dampers compared to passive controlled and uncontrolled structures. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

18.
This paper presents an energy‐based theoretical model for a two degree‐of‐freedom mechanical system. After a general formulation in Appendix A, the model is specialized to study tuned mass dampers as a means to substantially increase modal damping in order to induce a consequential decrease of the seismic response of the structures thus provided. Although approximate since it neglects coupling due to damping, it is shown that the model yields a first‐order approximation to the exact frequencies, providing values of optimum damping that closely match exact results proposed by others. In view of this, it is proposed that the model be applied through an iterative numerical procedure that identifies the pertinent optimum parameters. It is also shown that for certain particular benchmark cases the model provides closed‐form equations for the parameters defining the dynamic states related to these special conditions. Despite its approximate nature the model presented in this paper is rational, and due to its explicit consideration of energy balance and overall simplicity, it provides a convenient platform for the study of tuned mass dampers, as well as for other methods of structural passive control. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
This paper studies tuned mass dampers (TMDs) resulting in high modal damping for mechanical systems incorporating such devices for the purpose of seismic response reduction. Focusing on the determination of damping and tuning, the proposed methodology identifies a point of multiplicity of complex eigenvalues and eigenvectors, resulting in different parameters for TMDs according to their location with respect to such multiplicity condition. It is shown that significant equal modal damping and average modal damping can be induced by properly tuning highly damped TMDs, obtaining parameters intrinsic to the mechanical systems, and excitation independent. Further, it is shown that the methodology yields, as particular cases, two proposals by others using TMDs for the same purpose of seismic response abatement. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents a new optimization approach for designing minimum-cost fail-safe distributions of fluid viscous dampers for seismic retrofitting. Failure is modeled as either complete damage of the dampers or partial degradation of the dampers' properties. In general, this leads to optimization problems with large number of constraints. This may result in high computational costs if all the constraints are simultaneously considered during the optimization analysis. Thus, to reduce the computational effort, the use of a working-set optimization algorithm is proposed in this paper. The main idea is to solve a sequence of relaxed optimization subproblems with a small subset of all constraints. The algorithm terminates once a solution of a subproblem is found that satisfies all the constraints of the problem. The retrofitting cost is minimized with constraints on the interstory drifts at the peripheries of frame structures. The structures considered are subjected to a realistic ensemble of ground motions, and their response is evaluated with time-history analyses. The transient optimization problem is efficiently solved with a gradient-based sequential linear programming algorithm. The gradients of the response functions are calculated with a consistent adjoint sensitivity analysis procedure. Promising results attained for 3-D irregular frames are presented and discussed. The numerical results highlight the fact that the optimized layout and size of the dampers can change significantly even for moderate levels of damage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号