首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Superstorm Sandy provided an opportunity to study filamentous fungi (molds) associated with winter storm damage. We collected 36 morphologically distinct fungal isolates from flooded buildings. By combining traditional morphological and cultural characters with an analysis of ITS sequences (the fungal DNA barcode), we identified 24 fungal species that belong to eight genera: Penicillium (11 species), Fusarium (four species), Aspergillus (three species), Trichoderma (two species), and one species each of Metarhizium, Mucor, Pestalotiopsis, and Umbelopsis. Then, we used a Drosophila larval assay to assess possible toxicity of volatile organic compounds (VOCs) emitted by these molds. When cultured in a shared atmosphere with growing cultures of molds isolated after Hurricane Sandy, larval toxicity ranged from 15 to 80%. VOCs from Aspergillus niger 129B were the most toxic yielding 80% mortality to Drosophila after 12 days. The VOCs from Trichoderma longibrachiatum 117, Mucor racemosus 138a, and Metarhizium anisopliae 124 were relatively non‐toxigenic. A preliminary analysis of VOCs was conducted using solid‐phase microextraction‐gas chromatography‐mass spectrometry from two of the most toxic, two of the least toxic, and two species of intermediate toxicity. The more toxic molds produced higher concentrations of 1‐octen‐3‐ol, 3‐octanone, 3‐octanol, 2‐octen‐1‐ol, and 2‐nonanone; while the less toxic molds produced more 3‐methyl‐1‐butanol and 2‐methyl‐1‐propanol, or an overall lower amount of volatiles. Our data support the hypothesis that at certain concentrations, some VOCs emitted by indoor molds are toxigenic.  相似文献   

2.
3.
Typhoon Morakot has been the most severe typhoon disaster to strike Taiwan in recent decades causing tremendous damage to bridge surroundings in 2009. However, we still lack a means of assessing post-typhoon damage for follow-up rebuilding. This paper presents an integrated model that automatically measures changes in rivers, areas of damage to bridge surroundings, and changes in vegetation. The proposed model is based on a neurofuzzy mechanism enhanced by the self-organising map optimisation algorithm and also includes the particular functions of dilation, erosion, and skeletonisation to deal with river imagery. High resolution FORMOSAT-2 satellite imagery from before and after the invasion period is adopted. A bridge is randomly selected from the 129 destroyed due to the typhoon for applications of the model. The recognition results show that the river average width has increased 66% with a maximum increase of over 200%. The ruined segment of the bridge is located exactly in the most scoured region. There has also been a nearly 10% reduction in the vegetation coverage. The results yielded by the proposed model demonstrate a pinpoint accuracy rate of 99.94%. This study successfully develops a tool for large-scale damage assessment as well as for precise measurement after disasters.  相似文献   

4.
Most of human exposure to atmospheric pollutants occurs indoors, and the components of outdoor aerosols may have been changed in the way before reaching indoor spaces. Here we conducted real-time online measurements of mass concentrations and chemical composition of black carbon and the non-refractory species in PM2.5 in an occupied office for approximately one month. The open-close windows and controlled dampness experiments were also performed. Our results show that indoor aerosol species primarily originate from outdoors with indoor/outdoor ratio of these species typically less than unity except for certain organic aerosol (OA) factors. All aerosol species went through filtration upon transport indoors. Ammonium nitrate and fossil fuel OA underwent evaporation or particle-to-gas partitioning, while less oxidized secondary OA (SOA) underwent secondary formation and cooking OA might have indoor sources. With higher particulate matter (PM) mass concentration outdoors than in the office, elevated natural ventilation increased PM exposure indoors and this increased exposure was prolonged when outdoor PM was scavenged. We found that increasing humidity in the office led to higher indoor PM mass concentration particularly more oxidized SOA. Overall, our results highlight that indoor exposure of occupants is substantially different from outdoor in terms of mass concentrations and chemical species.  相似文献   

5.
To evaluate the separate impacts on human health and establish effective control strategies, it is crucial to estimate the contribution of outdoor infiltration and indoor emission to indoor PM2.5 in buildings. This study used an algorithm to automatically estimate the long-term time-resolved indoor PM2.5 of outdoor and indoor origin in real apartments with natural ventilation. The inputs for the algorithm were only the time-resolved indoor/outdoor PM2.5 concentrations and occupants’ window actions, which were easily obtained from the low-cost sensors. This study first applied the algorithm in an apartment in Tianjin, China. The indoor/outdoor contribution to the gross indoor exposure and time-resolved infiltration factor were automatically estimated using the algorithm. The influence of outdoor PM2.5 data source and algorithm parameters on the estimated results was analyzed. The algorithm was then applied in four other apartments located in Chongqing, Shenyang, Xi'an, and Urumqi to further demonstrate its feasibility. The results provided indirect evidence, such as the plausible explanations for seasonal and spatial variation, to partially support the success of the algorithm used in real apartments. Through the analysis, this study also identified several further development directions to facilitate the practical applications of the algorithm, such as robust long-term outdoor PM2.5 monitoring using low-cost light-scattering sensors.  相似文献   

6.
A one-year prospective survey of fungal air contamination was conducted in outdoor air and inside two haematological units of a French hospital. Air was sampled with a portable Air System Impactor. During this period of survey, the mean viable fungal load was 122.1 cfu/m3 in outdoor air samples, and 4.1 and 3.9 cfu/m3 in samples from adult and pediatric haematology units, respectively. In outdoor samples, Cladosporium was the dominant genus (55%) while in the clinical units, Penicillium sp. (23 to 25%), Aspergillus sp. (15 to 23%) and Bjerkandera adusta (11 to 13%) were the most frequently recovered airborne fungi. The outdoor fungal load was far higher in autumn (168 cfu/m3), spring (110 cfu/m3) and summer (138 cfu/m3) than in winter (49 cfu/m3). In indoor air, fungal concentrations were significantly lower in winter (2.7 to 3.1 cfu/m3) than in summer (4.2 to 5.0 cfu/m3) in both haematology units. In the outdoor environment, Penicillium sp. and Aspergillus sp. were more abundant in winter while the levels of Cladosporium were lowest during this season. In the haematological units, the presence of Aspergillus sp. was stable during the year (close to 20%), Bjerkandera sp. was particularly abundant in winter (close to 30%); levels of Penicillium sp. were highest in autumn while levels of Cladosporium sp. were highest in spring and summer.  相似文献   

7.
This study evaluated the interrelations between indoor and outdoor bioaerosols in a bedroom under a living condition. Two wideband integrated bioaerosol sensors were utilized to measure indoor and outdoor particulate matter (PM) and fluorescent biological airborne particles (FBAPs), which were within a size range of 0.5-20 μm. Throughout this one-month case study, the median proportion of FBAPs in PM by number was 19% (5%; the interquartile range, hereafter) and 17% (3%) for indoors and outdoors, respectively, and those by mass were 78% (12%) and 55% (9%). According to the size-resolved data, FBAPs dominated above 2 and 3.5 μm indoors and outdoors, respectively. Comparing indoor upon outdoor ratios among occupancy and window conditions, the indoor FBAPs larger than 3.16 μm were dominated by indoor sources, while non-FBAPs were mainly from outdoors. The occupant dominated the indoor source of both FBAPs and non-FBAPs. Under awake and asleep, count- and mass-based mean emission rates were 45.9 and 18.7 × 106 #/h and 5.02 and 2.83 mg/h, respectively. Based on indoor activities and local outdoor air quality in Singapore, this study recommended opening the window when awake and closing it during sleep to lower indoor bioaerosol exposure.  相似文献   

8.
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5‐year‐old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82 × 104 and 1.32 × 104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15 × 104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17 × 104, 3.28 × 104, and 4.09 × 104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31 × 103, 11.3 × 103, and 7.14 × 103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5‐year‐old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.  相似文献   

9.
Cao JJ  Lee SC  Chow JC  Cheng Y  Ho KF  Fung K  Liu SX  Watson JG 《Indoor air》2005,15(3):197-204
Six residences were selected (two roadside, two urban, and two rural) to evaluate the indoor-outdoor characteristics of PM(2.5) (aerodynamic diameter <2.5 microm) carbonaceous species in Hong Kong during March and April 2004. Twenty-minute-averaged indoor and outdoor PM(2.5) concentrations were recorded by DustTrak samplers simultaneously at each site for 3 days to examine diurnal variability of PM(2.5) mass concentrations and their indoor-to-outdoor (I/O) ratios. Daily (24-h average) indoor/outdoor PM(2.5) samples were collected on pre-fired quartz-fiber filters with battery-powered portable mini-volume samplers and analyzed for organic and elemental carbon (OC, EC) by thermal/optical reflectance (TOR) following the Interagency Monitoring of Protected Visual Environments (IMPROVE) protocol. The average indoor and outdoor concentrations of 24 h PM(2.5) were 56.7 and 43.8 microg/m(3), respectively. The short-term PM(2.5) profiles indicated that the penetration of outdoor particles was an important contributor to indoor PM(2.5), and a household survey indicated that daily activities were also sources of episodic peaks in indoor PM(2.5). The average indoor OC and EC concentrations of 17.1 and 2.8 microg/m(3), respectively, accounted for an average of 29.5 and 5.2%, respectively, of indoor PM(2.5) mass. The average indoor OC/EC ratios were 5.8, 9.1, and 5.0 in roadside, urban, and rural areas, respectively; while average outdoor OC/EC ratios were 4.0, 4.3, and 4.0, respectively. The average I/O ratios of 24 h PM(2.5), OC, and EC were 1.4, 1.8, and 1.2, respectively. High indoor-outdoor correlations (r(2)) were found for PM(2.5) EC (0.96) and mass (0.81), and low correlations were found for OC (0.55), indicative of different organic carbon sources indoors. A simple model implied that about two-thirds of carbonaceous particles in indoor air are originated from outdoor sources. PRACTICAL IMPLICATIONS: Indoor particulate pollution has received more attentions in Asia. This study presents a case study regarding the fine particulate matter and its carbonaceous compositions at six residential homes in Hong Kong. The characteristics and relationship of atmospheric organic and elemental carbon were discussed indoors and outdoors. The distribution of eight carbon fractions was first reported in indoor samples to interpret potential sources of indoor carbonaceous particles. The data set can provide significant scientific basis for indoor air quality and epidemiology study in Hong Kong and China.  相似文献   

10.
This study presents for the first time comprehensive measurements of the particle number size distribution (10 nm to 10 μm) together with next-generation sequencing analysis of airborne bacteria inside a dental clinic. A substantial enrichment of the indoor environment with new particles in all size classes was identified by both activities to background and indoor/outdoor (I/O) ratios. Grinding and drilling were the principal dental activities to produce new particles in the air, closely followed by polishing. Illumina MiSeq sequencing of 16S rRNA of bioaerosol collected indoors revealed the presence of 86 bacterial genera, 26 of them previously characterized as potential human pathogens. Bacterial species richness and concentration determined both by qPCR, and culture-dependent analysis were significantly higher in the treatment room. Bacterial load of the treatment room impacted in the nearby waiting room where no dental procedures took place. I/O ratio of bacterial concentration in the treatment room followed the fluctuation of I/O ratio of airborne particles in the biology-relevant size classes of 1–2.5, 2.5–5, and 5–10 μm. Exposure analysis revealed increased inhaled number of particles and microorganisms during dental procedures. These findings provide a detailed insight on airborne particles of both biotic and abiotic origin in a dental clinic.  相似文献   

11.
Moulds can both degrade the materials and structures they colonise and contribute to the appearance of symptoms and diseases in the inhabitants of contaminated dwellings. Only few data have compared the levels of contamination in urban and rural environments and the results are not consistent. The aim of this study was to use a fungal contamination index, based on the detection of specific Microbial Volatile Organic Compounds (MVOC), to determine the exposure to moulds of individuals living in urban and rural dwellings. For this purpose, 94 dwellings (47 in an urban setting in Clermont-Ferrand and 47 in rural areas of the Auvergne region, France) were studied.By demonstrating marked disparities between the proportion of visible contamination (19%) and that of active, visible and/or hidden contamination (59%) and the fact that almost all visible contamination was identified by MVOC, we were able to show that use of the index seemed relevant to confirm the actual presence of fungal contamination in a dwelling. Furthermore, it was possible to demonstrate a relationship between moulds and the presence of water on surfaces (condensation, infiltrations, water damage, etc.). A higher proportion of positive fungal contamination index in rural homes was observed compared to the proportion in urban ones (68% versus 49%; p < 0.05).  相似文献   

12.
Performance of two widely used air conditioning (AC) systems, variable air volume (VAV) and variable refrigerant flow (VRF), in an existing office building environment under the same indoor and outdoor conditions for an entire cooling season is simulated by using two validated respective models and compared. It was observed that the indoor temperatures could not be maintained properly at the set temperature by the VAV no-reheat boxes. However, it could be maintained by the VAV boxes with reheat with a significant energy consumption penalty. It was found that the secondary components (indoor and ventilation units) of the VRF AC system promised 38.0-83.4% energy-saving potential depending on the system configuration, indoor and outdoor conditions, when compared to the secondary components (heaters and the supply fan) of the VAV AC system. Overall, it was found that the VRF AC system promised 27.1-57.9% energy-saving potentials depending on the system configuration, indoor and outdoor conditions, when compared to the VAV AC system.  相似文献   

13.
The intensity, frequency, duration, and contribution of distinct PM2.5 sources in Asian households have seldom been assessed; these are evaluated in this work with concurrent personal, indoor, and outdoor PM2.5 and PM1 monitoring using novel low-cost sensing (LCS) devices, AS-LUNG. GRIMM-comparable observations were acquired by the corrected AS-LUNG readings, with R2 up to 0.998. Twenty-six non-smoking healthy adults were recruited in Taiwan in 2018 for 7-day personal, home indoor, and home outdoor PM monitoring. The results showed 5-min PM2.5 and PM1 exposures of 11.2 ± 10.9 and 10.5 ± 9.8 µg/m3, respectively. Cooking occurred most frequently; cooking with and without solid fuel contributed to high PM2.5 increments of 76.5 and 183.8 µg/m3 (1 min), respectively. Incense burning had the highest mean PM2.5 indoor/outdoor (1.44 ± 1.44) ratios at home and on average the highest 5-min PM2.5 increments (15.0 µg/m3) to indoor levels, among all single sources. Certain events accounted for 14.0%-39.6% of subjects’ daily exposures. With the high resolution of AS-LUNG data and detailed time-activity diaries, the impacts of sources and ventilations were assessed in detail.  相似文献   

14.
15.
Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon monoxide (CO) and oxides of nitrogen (NO and NO2) concentrations were conducted at three different environments, i.e. rural, urban and roadside in Agra, India, using YES - 205 multigas monitor during the winter season, i.e. October 2002-February 2003. A statistical correlation analysis of indoor concentration levels with outdoor concentrations was carried out. CO was maximum at roadside locations with indoor concentrations 2072.5 +/- 372 p.p.b. and outdoor concentrations 1220 +/- 281 p.p.b. (R2 = 0.005). Oxides of nitrogen were found maximum at urban site; NO concentration was 385 +/- 211 and 637 +/- 269 p.p.b. for indoors and outdoors respectively (R2 = 0.90792), where as NO2 concentration was 255 +/- 146 p.p.b. for indoors and 460 +/- 225 p.p.b. for outdoors (R2 = 0939464). Although indoor concentration at all the houses of the three sites have a positive correlation with outdoor concentration, CO variation indoors was very less due to outdoor sources. An activity schedule of inside and outside these homes were also prepared to see its influence and concentrations of pollutants. As standards for indoor air were not available for the Indian conditions these were compared with the known standards of other countries, where as outdoor concentrations were compared with the standards given by the Central Pollution Control board, which shows that indoor concentrations of both NO(x) and CO lie below permissible limits but outdoor concentrations of NO(x) cross the standard limits. PRACTICAL IMPLICATIONS: 'India currently bears the largest number of indoor air pollution (IAP) related health problems in world. An estimated 500,000 women & children die in India each year due to IAP-related cause--this is 25% of estimated IAP-related deaths worldwide. This study will be useful for policy makers, health related officials, academicians and Scientists who have interest in countries of developing world'.  相似文献   

16.
Hypertension is the leading cause of cardiovascular disease worldwide. Long-term arsenic exposure has been linked to increased risk for hypertension; however, little is known whether a previous exposure has lingering effects on hypertension after the exposure being reduced significantly for decades. The study cohort was established in 1990 in an arseniasis-endemic area of 3 villages — Homei, Fuhsin, and Hsinming in Putai Township located on the southwestern coast of Taiwan, where residents were exposed to artesian well water (median level = 700 to 930 μg/L) until early 1970s. The original cohort consisted of 490 non-hypertensive residents over 30-yrs-old and 352 of them were successfully followed up in 2002/03. Arsenic concentrations in the artesian well water consumed by residents during 1960s were used to indicate the previous exposure while urinary arsenic species measured in 2002/3 was used to represent current exposure. Hypertension incidences were 27.4, 65.6, and 69.1, per 1000 person-years for men aged 35-49, 50-64, and 65-74 years, respectively being higher than the corresponding rates of 25.1, 46.1, and 57.2 in a community-based longitudinal study. Cancer was the major cause of the total deaths (17/30 = 57%). Diastolic blood pressure was shown to increase with an increased cumulative arsenic ingestion from drinking water (β = 0.27, p < 0.001). The incidence was increased by 2.43-fold in subjects of As(V) ≥ 2.67 μg/g creatinine as compared to those of As(V) < 1.20 μg/g creatinine (the third vs. first tertile; p = 0.047) after adjustment for conventional risk factors. This study suggests that three decades after cessation of drinking artesian well water, residents of the endemic area are still at increased risk for developing hypertension, particularly those who excrete high amounts of As(V).  相似文献   

17.
Assessment of indoor air quality in typical classrooms is vital to students’ health and their performance. The present study was designed to monitor indoor and outdoor size-resolved particle concentrations in a naturally ventilated classroom and investigate factors influencing their levels and relationships. The experiments were performed, at normal ventilation condition with doors and windows opened, on the top floor of a public school building near a busy commercial area of Chiang Mai, Thailand. The particle number concentrations were measured using an optical counter with four size intervals between 0.3 and 5.0 μm. The dataset was collected during weekdays and weekends with a 24 h sampling period over November and December 2005. It was observed that the median indoor particle number concentrations during daytime for 0.3–0.5, 0.5–1.0, 1.0–2.5, and 2.5–5.0 μm size intervals were about 1.6×108, 1.7×107, 1.2×106, and 4.1×105 particles/m3, respectively. It was also found that concentrations at weekends were slightly higher those measured on weekdays, and at night, appeared to be higher than daytime. Indoor particles were observed to exhibit similar temporal variation pattern with outdoor particles. Results suggested that a significant contribution to indoor particles was from penetration of outdoor particles, whereas indoor sources generated from occupant activity did not show strong evidence. High outdoor particle loading and high air exchange rate were thought to be predominant causes. Ratios of indoor-to-outdoor (I/O) particle concentrations varied in a relatively narrow range from 0.69 to 0.88 with average values well below 1. The I/O ratios were in the range from 0.74 to 0.88 for submicrometer particles and from 0.69 to 0.80 for supermicrometer particles.  相似文献   

18.
Japanese cedar pollinosis (JCP) caused by allergenic cedar and cypress pollens is one of major economic and health issues in Japan. The present study reported here aimed to provide basic data to understand the status of early life exposures to airborne cedar and cypress pollens in school settings. In particular, the study investigated relationships between indoor and outdoor concentrations of airborne cedar and cypress pollens and total suspended particulates (TSP) in a kindergarten in Japan. Overall, outdoor concentrations of the airborne pollens and TSP were higher than the indoor concentrations, i.e., indoor to outdoor (I/O) ratios of 0.043–0.055 and 0.545 for the airborne pollens and TSP, respectively. The smaller I/O ratios for the pollens were expected because the larger pollen grains (20–30 μm in diameter) were less likely penetrated to indoor environment than for smaller airborne particulates. The present study also found increased TSP concentrations during the pollen season was likely attributed to increased airborne pollen concentrations. By understanding the status of indoor and outdoor concentrations of airborne cedar and cypress pollens in school settings, early life exposures to these allergenic pollens should be effectively minimized to prevent subsequent progression to JCP symptoms.  相似文献   

19.
膜生物反应器在污水深度处理中的技术研究   总被引:1,自引:1,他引:0  
试验研究了以膜生物反应器(MBR)为核心的单元式再生水处理装置(处理能力为30m3/d)在设置成A/O型MBR和A2/O型MBR两种工艺组合和不同运行条件下(如安装BS填料、投加PAC、改变原水条件和增减膜组件数量等)对城市污水的深度处理效果。试验结果表明单元式再生水处理装置具有较高的污泥浓度(MLSS=10000~12000mg/L)和较强的抗冲击负荷(温度、水质变化等)能力。在不同工况下CODcr、BOD5、NH3-N、TN、SS、浊度、色度和粪大肠菌群数等指标均达到或优于国家一级A标准。优化的A2/O型MBR工艺的各项出水指标达到或优于国家一级A标准。BS填料可明显提高生物脱氮效率。  相似文献   

20.
焦艳君 《山西建筑》2009,35(32):367-368
以侯马电厂三期扩建工程为例,介绍了远程I/O和现场总线在该工程中的应用,阐述了远程智能I/O和现场总线的经济价值,并对其应用和发展前景进行了展望,指出其必将成为现代化企业DCS中数据采集发展的趋势,具有强大的生命力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号