首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
2.
Oral Diseases (2010) 16 , 655–660 Objective: To evaluate the efficacy of a novel immunomodulating peptide (SCV‐07) in attenuating the course of radiation‐induced mucositis in an established animal model of oral mucositis (OM). Material and Methods: In three separate experiments, golden Syrian hamsters received either an acute radiation challenge to the buccal mucosa of eight fractionated doses of 7.5 Gy of radiation over a 2‐week‐period, or a combination of acute radiation and cisplatin. In each experiment, animals were treated with varying doses or schedules of SCV‐07 or placebo. OM was scored in a blinded fashion using digital images obtained during the experimental period. Results: We found that SCV‐07 reduced the severity and duration of both acute and fractionated radiation‐induced OM. Similarly, when radiation and chemotherapy were used to induce OM, treatment with SCV‐07 significantly reduced the duration of ulcerative OM. The therapeutic benefit was dependent on both dose and schedule of administration. Conclusion: Taken together, we found SCV‐07 was able to modify the duration and severity of oral mucositis and was dependent on schedule and dose.  相似文献   

3.
4.
Takenouchi Y, Ohshima M, Yamaguchi Y, Nishida T, Senda N, Idesawa M, Otsuka K, Ito K. Insulin‐like growth factor‐binding protein‐2 and ‐3 in gingival crevicular fluid. J Periodont Res 2010; 45: 803–808. © 2010 John Wiley & Sons A/S Background and Objective: Insulin‐like growth factor‐binding proteins (IGFBPs) are crucial regulators of insulin‐like growth factor (IGF). They enhance or inhibit IGF functions, but also exhibit IGF‐independent effects. In a previous study, we detected, qualitatively, IGFBP‐2 and ‐3 in gingival crevicular fluid using a cytokine antibody array. Here we extended these results using an ELISA to determine the concentrations of IGFBP‐2 and ‐3 in gingival crevicular fluid. In addition, we explored whether the expression of IGFBP‐2 and IGFBP‐3 correlates with periodontal disease severity. Material and Methods: Gingival crevicular fluid samples from 92 sites of 12 patients affected with periodontal disease and from 100 sites of 19 healthy volunteers, were collected, divided into two groups and analyzed by ELISA for IGFBP‐2 and ‐3 expression. The potential correlation among probing depth, gingival index and the concentrations of IGFBP‐2 and ‐3 was analyzed. Results: Positive correlations were observed between the concentration of IGFBP‐2 and probing depth and gingival index, but not for IGFBP‐3. The IGFBP‐2 concentrations at bleeding on probing‐positive sites and at sites with a probing depth of ≥ 4 mm were higher than at bleeding on probing‐negative sites and at sites with a probing depth of ≤ 3 mm. Conclusion: These results indicate that IGFBP‐2 is a potential novel marker for periodontal disease progression. As IGFBP‐2 modulates bone metabolism and cell migration, IGFBP‐2 in the gingival crevicular fluid may reflect periodontal disease activity.  相似文献   

5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Purpose: The purpose of this in vitro study was to compare the porcelain fracture resistance between screw‐retained, cement‐retained, and combined screw‐ and cement‐retained metal–ceramic (MC) implant‐supported posterior single crowns; and to investigate the effect of offsetting the occlusal screw‐access opening on porcelain fracture resistance of screw‐retained and cement‐retained MC implant‐supported posterior single crowns. Materials and Methods: Forty standardized MC molar‐shaped restorations were fabricated. The 40 restorations were divided into four groups (SRC, SRO, CRP, and CSC) of 10 specimens each. Group SRC: screw‐retained, screw‐access hole placed in the center of the occlusal surface; Group SRO: screw‐retained, screw access hole placed 1 mm offset from the center of the occlusal surface toward the buccal cusp; Group CRP: cement‐retained, zinc phosphate cement was used; Group CSC: cement‐retained with a screw‐access hole in the center of the occlusal surface. The screw‐retained restorations and abutments were directly attached to 3i implant fixtures embedded in acrylic resin blocks. Subsequently, all test specimens were thermocycled and vertically loaded in a universal testing machine at a crosshead speed of 2 mm/min until fracture. Mean values of load at fracture (in N) were calculated in each group and compared with a one‐way ANOVA and Tukey's Studentized test (α= 0.05). Results: Mean values of loads required to fracture the restorations were as follows (N): Group SRC: 1721 ± 593; Group SRO: 1885 ± 491; Group CRP: 3707 ± 1086; Group CSC: 1700 ± 526. Groups SRC, SRO, and CSC required a significantly lower force to fracture the porcelain than did the CRP group (p < 0.05). Conclusion: The cement‐retained restorations showed significantly higher mean fracture loads than the restorations having screw‐access openings in their occlusal surface. The position of the screw‐access hole within the occlusal surface did not significantly affect the porcelain fracture resistance.  相似文献   

16.
17.
We examined the effect of warm air‐drying on the enamel bond strengths and the surface free‐energy of three single‐step self‐etch adhesives. Bovine mandibular incisors were mounted in self‐curing resin and then wet ground with #600 silicon carbide (SiC) paper. The adhesives were applied according to the instructions of the respective manufacturers and then dried in a stream of normal (23°C) or warm (37°C) air for 5, 10, and 20 s. After visible‐light irradiation of the adhesives, resin composites were condensed into a mold and polymerized. Ten samples per test group were stored in distilled water at 37°C for 24 h and then the bond strengths were measured. The surface free‐energies were determined by measuring the contact angles of three test liquids placed on the cured adhesives. The enamel bond strengths varied according to the air‐drying time and ranged from 15.8 to 19.1 MPa. The trends for the bond strengths were different among the materials. The value of the component increased slightly when drying was performed with a stream of warm air, whereas that of the component decreased significantly. These data suggest that warm air‐drying is essential to obtain adequate enamel bond strengths, although increasing the drying time did not significantly influence the bond strength.  相似文献   

18.
19.
The use of matrix metalloproteinase (MMPs) inhibitors, such as 12‐methacryloyloxy‐dodecyl‐pyridinium‐bromide (MDPB), might improve the adhesion of glass‐fiber (GF) and polyfiber (PF) posts to root dentine. This study assessed the effect of an MDPB‐containing adhesive on the long‐term bond strength of GF or PF posts to bovine dentine. Bovine endodontically treated roots were randomly divided into six groups, according to the post type and adhesive system used, as follows: GF serrated post + MDBP‐free adhesive; GF serrated post + MDPB‐containing adhesive; GF smooth post + MDBP‐free adhesive; GF smooth post + MDPB‐containing adhesive; PF post + MDBP‐free adhesive; PF post + MDPB‐containing adhesive. Specimens were stored in water for 6 months, thermocycled (500 cycles wk?1), and submitted to the pull‐out test and failure pattern analysis. The cement–dentin interface was evaluated using scanning electron microscopy. The pull‐out data were analyzed using anova and Tukey's test (α = 0.05). No significant interaction between the type of post and the adhesive system was found. Polyfiber posts showed lower bond strength than GF posts, whether serrated or smooth, and the bond strength of the serrated and smooth GF posts was not significantly different. Adhesive failures were predominant in all groups. The type of retainer influenced the bond strength, and MDPB‐containing adhesive did not improve the long‐term bond strength of posts to dentine.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号