首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Parallel laboratory investigations were conducted to examine aspects of two distinct but related bioprocess strategies for low sludge production in the treatment of the same TCF kraft pulp mill effluent. The purpose of this article has been to compare the performance results from these two bench-scale trials with respect to nutrient demands, nutrient discharge, COD removal, and waste sludge characteristics. The LSP (Low Sludge Production) process can be used to significantly reduce sludge yield with excellent sludge characteristics. These sludge characteristics seemed to be related to elevated protozoan grazing pressures. The BAS (Biofilm-Activated Sludge) process achieves similar reduced sludge yields and sludge characteristics while at the same time significantly reducing the nutrient demands and discharge levels. For both LSP and BAS process optimization, the selector nutrient loading is critical to the overall process performance. Selector nutrient requirements are distinct from the overall process nutrient requirements.  相似文献   

2.
This paper contains two contributions. First it is shown, in a simulation study using the IAWQ model, that a linear multivariable time-invariant state-space model can be used to predict the ammonium and nitrate concentration in the last aerated zone in a pre-denitrifying activated sludge process. Secondly, using the estimated linear model, a multivariable linear quadratic (LQ) controller is designed and used to control the ammonium and nitrate concentration.  相似文献   

3.
氧化沟工艺污泥膨胀及出水水质影响因素的研究   总被引:1,自引:0,他引:1  
针对丝状菌污泥膨胀造成改良式氧化沟工艺处理城市生活污水超标的问题,通过分析进水水质、溶解氧、温度、污泥膨胀指数、出水水质变化的关系,探讨了导致丝状菌膨胀的主要限制因子以及出水水质的变化.研究结果表明,此工艺中进水BOD5、CODcr、TP浓度和pH值变化不是导致污泥膨胀的原因,进水TN和环境温度对污泥膨胀略有影响,DO、NH3-N变化与SVI有较强的相关性,DO和NH3-N越高,SVI越低.  相似文献   

4.
This study investigated the discrepancies between the BOD removal rates measured during short term assays and those measured during continuous activated sludge treatment of bleached kraft mill effluent (BKME). A combination of batch tests and fed batch tests with oxygen uptake rate (OUR), chemical oxygen demand (COD), biochemical oxygen demand (BOD), and mixed liquor volatile suspended solids (MLVSS) measurements were used to characterize the degradation rates for the activated sludge treatment of BKME and to divide the soluble readily biodegradable substrate into two to five separate fractions based on biodegradation rates. The removal rates varied by over an order of magnitude between the most readily degradable substrates (1 x 10(-3) mg COD/mg MLVSS minute), and the more slowly degradable substrates (2 x 10(-5) mg COD/mg MLVSS minute). If the readily biodegradable fraction of BKME was modeled as one substrate, initial rate kinetic measurements from batch tests were heavily influenced by the fractions with the greatest degradation rates, while any remaining BOD in the treated effluent was predominantly from the slowly degradable fraction, giving inconsistent results. Taking the multi-component nature of the wastewater into account, batch test results can be used to predict fed-batch and continuous activated sludge reactor performance.  相似文献   

5.
This study investigates variations of phosphorus and polyhydroxyalkanoates (PHAs) in a combined activated sludge - biofilm process, operating under various sludge retention times (5, 10 and 15 days) and different dissolved oxygen conditions (0.1, 0.5, 1.0 and 2.0 mg/l in aerobic stage). Experimental results indicate that phosphorus uptake closely corresponds to utilization of PHAs during anoxic and aerobic stages. Moreover, the sludge in the anoxic stage exhibits a higher PHAs utilization efficiency with respect to phosphorus uptake than sludge in the aerobic stage, when it is under low COD-SS loading conditions. The values of rP/PHA, representing sludge capacity on phosphorus uptake, range from 0.1–1.0 mg P/mg PHAs. In addition, analyzing the distribution of 3-hydroxybutyrate (3HB), 3-hydroxy-2-methylbutyrate (3H2MB), 3hydroxyvalerate (3HV) and 3-hydroxy-2-methylvalerate (3H2MV) reveals that 3HB and 3HV are the major components of PHAs. The values of 3HB/PHAs and 3HV/PHAs vary with COD-SS loading of the process. When F/M ratio increases, 3HV/PHAs value increases and 3HB/PHAs value decreases simultaneously. This phenomenon implies that more bacteria accumulated 3HV as storage matter under high COD-SS loading conditions. The kind of bacteria population shift would intensify the competition of “G bacteria” with polyphosphate accumulating organisms, possibly causing process deterioration during phosphorus removal.  相似文献   

6.
The electrochemical advanced oxidation process (EAOP) using boron doped diamond (DiaChem, registered trademark of Condias GmbH) has been studied for wastewater treatment and drinking water disinfection. DiaChem electrodes consist of preferentially metallic base materials coated with a conductive polycrystalline diamond film by hot-filament chemical vapour deposition. They exhibit high overpotential for water electrolysis as well as high chemical inertness and extended lifetime. In particular the high overpotential for water decomposition opens the widest known electrochemical window, allowing the energy efficient production of hydroxyl radicals directly from aqueous solutions. The hydroxyl radicals on the other hand are effectively used for the oxidation of pollutants. The EAOP using DiaChem electrodes thus facilitates the direct and, if necessary, complete decomposition of even hazardous or persistent pollutants in different wastewaters. Current efficiencies of more than 90%, also without the use of additives for hydroxyl radical generation, have been demonstrated. Additionally, for drinking water preparation diamond electrodes facilitate disinfection with and without the support of chlorine.  相似文献   

7.
A full-scale wastewater treatment plant where municipal and winery wastewaters were co-treated was studied for five years. The experimental results showed that suspended solids, COD, nitrogen and phosphorous were effectively removed both during the treatment of municipal wastewater and the cotreatment of municipal and winery wastewater. The sludge production increase from 4 tons to 5.5 tons per day during the harvesting and wine making period. In any case the specific sludge production was 0.2 kgMLVSS per kgCOD(removed) despite the organic loading increasing. About 70% of the COD was removed through respiration. Also the energy demand increased from 6,000 to 7,000 kWh per day. The estimated costs for the treatment of the winery wastewater was 0.2-0.3 Euros per m3 of treated wastewater. With reference to the process efficiency, the nitrogen removal was just 20%. The co-treatment of municipal and winery wastewater in conventional activated sludge processes can be a feasible solution for the treatment of these streams at relatively low costs.  相似文献   

8.
循环式活性污泥法工程设计方法探讨   总被引:1,自引:0,他引:1  
许劲  孙俊贻 《给水排水》2007,33(2):34-38
分析了CASS与CAST工艺的异同点,指出SBR工艺可以模拟多种不同的连续处理工艺,而CAST可以根据连续流A2/O工艺的设计方法进行设计.通过定义(进水 反应)阶段占每个运行周期的比例(§),引入有效污泥龄与有效水力停留时间的概念,分析了CAST同步硝化反硝化功能对主反应区DO的控制要求及对好氧SRT的影响,推荐采用CAST处理城市污水时使用经验值θc厌∶θc缺∶θc好=1∶2∶17;强调系统生物量的衰减由系统总SRT决定,调整(§)即可调整总污泥龄,并影响总产率系数.最后,给出了设计步骤和计算实例.当采用平均日流量设计时,建议采用较长的运行周期(6 h),便于在峰值流量时增加周期数,以保持CAST运行的灵活性.  相似文献   

9.
The diversity of autotrophic ammonia-oxidizing bacteria (AOB) of the b-subdivision of the class Proteobacteria was investigated in a laboratory-scale denitrification-nitrification bioreactor (DNB) treating a synthetic waste stream. 16S ribosomal RNA (rRNA) gene sequences were amplified from DNA extracted from the oxic DNB sludge. Comparative analysis of the rRNA sequences revealed considerable diversity among the AOB-like sequences. The majority of sequences recovered were related to Nitrosomonas spp. but a smaller number of Nitrosospira-like sequences were obtained. Since different AOB may have different kinetic properties the high diversity of AOB, even in a simple laboratory biotreater treating a simple waste stream, has important implications for the operation of nitrifying wastewater treatment processes.  相似文献   

10.
Heterogeneous catalytic ozonation (HCO) of wastewater is gaining both research and industrial interests. It is proved to be an advanced oxidation process since it involves hydroxyl radicals as oxidation species. Few studies have been carried out to test HCO in the treatment of landfill leachates. This work has been carried out to test three types of catalysts: activated carbon (AC), expanded perlite (EP) and titanium dioxide (TiO2) combined with ozone at 80 g/m3 gas concentration for the treatment of a leachate generated by Jebel Chakir landfill site near Tunis-capital of Tunisia. The work has shown a reduction in COD of about 45% and an increase in biodegradability (BOD5/COD) from 0.1 to 0.34. A catalyst concentration of 0.7 g/L was found optimal for the treatment of the leachate.  相似文献   

11.
To treat cutting oil wastewater produced in metal surface treatment industry, Ultrasonication (US)-Fenton process, which is one of the advanced oxidation processes, was used. The optimum conditions to treat non-biodegradable pollutants using the US-Fenton process were that the application rates of H2O2 and FeSO4 were 10% and 3 g/L, respectively, the value of pH was 3, and the ultrasonication time was 30 min. It identified non-degradable pollutants such as ethylene diamine tetraacetic acid (EDTA) and Triethanolamine (TEA) in the cutting oil wastewater. TLC analysis of two compounds of treated water by the coagulation process was similar to that of raw water. However, TLC analysis of two compounds of US-Fenton process was different from that of raw water, meaning that US-Fenton process decomposed the EDTA and TEA. To study the possibility of application with the US-Fenton process to pilot plant, the pollutants treatment efficiency of three different methods, such as US-Fenton process, activated sludge process and coagulation process, in continuous experiments were compared. The removal rate of pollutants by the US-Fenton process according to the effluent time was higher than any other processes. The removal rates of COD, SS, T-N and T-P by US-Fenton process were 98, 93, 75 and 95%, respectively.  相似文献   

12.
以长江陈行水库原水为研究对象,探讨了粉末活性炭—超滤组合工艺对水中CODMn、UV254、浊度、氨氮等去除效果,评价投加粉末活性炭后超滤膜跨膜压差(TMP)的变化情况.结果表明:超滤膜出水CODMn均值为1.10 mg/L,平均去除率为48.7%,UV254均值为0.016 cm-1,平均去除率为76.2%;组合工艺对水中氨氮具有一定的去除效果,对总铁、总锰去除效果显著,出水浊度保持在0.031 NTU以下.粉末活性炭投加于沉淀池之前,对于改善出水水质、减轻膜污染起到了较好的效果.  相似文献   

13.
Odours from wastewater treatment plants comprise a mixture of various gases, of which hydrogen sulphide (H2S) is the main constituent. Microorganisms commonly found in wastewater can degrade sulphurous compounds. Therefore, the use of activated sludge (AS) for odour control offers an alternative to traditional waste gas treatment processes, such as biofilters, bioscrubbers and biotrickling filters, both in practical terms (use of existing facilities) and economically (minimal capital cost). The performance of AS diffusion as a bioscrubber for removing H2S at concentrations at 25, 75 and 150 ppmv was evaluated. Pilot-scale trials were undertaken using parallel 60-L aeration tanks and 20-L clarifier reactors at the Bedford Sewage Treatment Works, Carington, UK. Olfactometry measurements were also carried out to determine whether there was any increase in odour concentration owing to H2S diffusion. Hydrogen sulphide removal rates of 100% were obtained, with no noticeable increase in odour concentration throughout the trials as measured by olfactometry. Odour concentration was highest at the beginning of the trials and lowest during the high H2S dosing period, with similar values being obtained for test and control. It was concluded that AS diffusion is an effective bioscrubber for the removal of H2S odour.  相似文献   

14.
In this paper a model predictive controller (MPC) for ammonia nitrogen is presented and evaluated in a real activated sludge process. A reduced nonlinear mathematical model based on mass balances is used to model the ammonia nitrogen in the activated sludge plant. An MPC algorithm that minimises only the control error at the end of the prediction interval is applied. The results of the ammonia MPC were compared with the results of the ammonia feedforward-PI and ammonia PI controllers from our previous study. The ammonia MPC and ammonia feedforward-PI controller give better results in terms of ammonia removal and aeration energy consumption than the ammonia PI controller because of the measurable disturbances used. On the other hand, with the ammonia MPC, comparable or even slightly poorer results than with the ammonia feedforward-PI controller are obtained. Further improvements to the MPC could be possible with an improved accuracy of the nonlinear reduced model of the ammonia nitrogen, more sophisticated control criteria used inside the controller and the extension of the problem from univariable ammonia to multivariable total nitrogen control.  相似文献   

15.
A catalytic wet peroxide oxidation process was combined with the aerated constructed wetland in order to treat the raw dyehouse wastewater to in acceptable level for reuse as washing process water. More than 90% of BOD and CODs could be removed with the wet peroxide oxidation reactor and the remaining pollutants in the treated water were transformed into biodegradable ones which could have been successfully treated at the following aerated constructed wetland. The highest values of BOD5, CODMn, CODCr, SS and T-N in the treated water were 1.6, 1.8, 2.1, 0.5 and 12.8 mg/L, respectively. These values were low enough for the treated water to be reused at the washing process.  相似文献   

16.
More stringent effluent and cost requirements are increasing the need for better control of wastewater treatment plants. In an activated sludge process, the nitrogen removal efficiency may be improved by adding an external carbon source. In this paper, automatic control of the nitrate level by regulating external carbon flow is discussed. More specifically, an iterative tuning procedure for the controller is outlined. Iterative controller design schemes aim at tuning high performance controllers of low complexity using closed loop data. The basic strategy used in this paper is an iterative pole placement controller design procedure. The suggested approach is compared with conventional design in a simulation study.  相似文献   

17.
吕建伟  李春峰 《给水排水》2005,31(12):54-55
采用UASB-水解酸化-接触氧化法处理阿维菌素废水,其中高浓度废水直接采用UASB处理,出水和综合废水混合经水解酸化后利用接触氧化法进行处理,系统处理效率高,运行稳定,CODCr去除率为97%,出水水质达到<污水综合排放标准>(GB 8978-1996)二级标准.  相似文献   

18.
The effect of rain events on effluent quality dynamics was studied at a full scale activated sludge wastewater treatment plant which has a process solution incorporating pre-denitrification in activated sludge with post-nitrification in trickling filters. The incoming wastewater flow varies significantly due to a combined sewer system. Changed flow conditions have an impact on the whole treatment process since the recirculation to the trickling filters is set by the hydraulic limitations of the secondary settlers. Apart from causing different hydraulic conditions in the plant, increased flow due to rain or snow-melting, changes the properties of the incoming wastewater which affects process performance and effluent quality, especially the particle removal efficiency. A comprehensive set of on-line and laboratory data were collected and analysed to assess the impact of rain events on the plant performance.  相似文献   

19.
The behaviour of As(III), As(V), MMA(v) and DMA(v) in batch activated sludge process were investigated. Experiments were carried out by using aerobic and anoxic reactors with an initial As concentration of 100 microjg I(-1). Under aerobic condition, As(III) was oxidized to As(V) within 9 hours, some part of MMA(v) was methylated to DMA(v) and some other part was demethylated to As(III), which in turn was immediately oxidized to As(V). Under anoxic condition, As(V) was reduced to As(III) within the same time-course. No significant transformation occurred during experiments conducted with DMA(v). It was found that all reactions were biologically mediated. The overall As removal was low (< 20%) during the experiments. Although a relationship seems to exist between the sludge concentration and As removal, it is concluded, under the conditions of our study, that the activated sludge process cannot remove arsenicals efficiently. However, it can control their transformations well. Thus, if associated with an appropriate technology, the activated sludge can be used for As pre-oxidation to treat As contaminated wastewaters. Finally, care must be taken on possible presence of MMA(v) in the influent of any wastewater treatment plant as it can be easily oxidized by the activated sludge.  相似文献   

20.
The degradation of a mixture of phenol, 4-chlorophenol (4CP), 2,4-dichlorophenol (24DCP) and 2,4,6-trichlorophenol (246TCP) by acclimated activated sludge and by isolated bacteria was studied. Activated sludge was acclimated for 70 days to 40 mg phenols/1 then the microorganisms responsible for the CP degradation were isolated and identified. Four types of Gram-negative bacteria (Aeromonas sp., Pseudomonas sp. Flavomonas oryzihabitans, and Chryseomonas luteola) were identified. Also, two acid-fast bacilli with distinct glycolipid patterns were isolated. From their chemical composition and their growth characteristics, both isolates appeared to be mycobacteria closely related to Mycobacterium peregrinum. The degradation kinetics of each phenol by Aeromonas sp., Pseudomonas sp. Flavomonas oryzihabitans, Chrvseomonas luteola and activated sludge were determined. The acclimated activated sludge degradation rates were from one to two orders of magnitude higher than those of pure strains when uptake rates were calculated in terms of the viable biomass (CFU). The specific substrate uptake rate for acclimated activated sludge varied between 8.2 and 15.8 ß 10−7 mg/CFU·d (407-784 mg/BVSS·d). Aeromonas sp. had the highest specific substrate uptake rate of the pure strains, based on a VSS basis (33–57 mg/gVSS·d) but, in terms of viable biomass (5.0–15.6 × 10−8 mg/CFU·d), the Pseudomonas sp. rate was the highest. Specific substrate uptake rates were 1.8 mg chlorinated phenoWg VSS-d for unacclimated activated sludge.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号