首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A modified method is proposed to predict the lateral displacement (δ) of prefabricated vertical drains (PVDs) improved ground under combined vacuum and surcharge loads, which is derived based on a few modified triaxial tests and a series of finite element analyses of PVD unit cells. It is observed that reducing the surcharge load (ps) and loading rate (LR) and increasing the vacuum pressure (pv), pre-vacuum consolidation period (tv), and initial undrained shear strength (su0) could be effective in controlling the outward δ. Variations of the effective stress ratio (Ke) that controlling the δ with ps, pv, LR, tv, and su0 are then presented. A synthetic relationship between the normalized horizontal strain (εh) by a reference one-dimensional vertical strain (εv1) and the normalized Ke by the at-rest earth pressure coefficient (K0) is proposed for cases with and without tv. Further, a modified index parameter (β1) is introduced for quantitatively considering the effect of ps, pv, LR, tv, su0, and consolidation properties of the soil, a relationship between Ke and β1 is then established for evaluating the value of Ke. Combinations of the εh/εv1Ke/K0 and Keβ1 relationships enable modified predictions of the δ from basic preloading conditions and soil parameters.  相似文献   

2.
Surcharge load (e.g. embankment fill) will induce settlement and outward lateral displacement, while vacuum pressure will induce settlement and inward lateral displacement of a ground. Ideally, combination of surcharge load and vacuum pressure can reduce or minimize the lateral displacement. Laboratory large scale model (length: 1.50 m, width: ∼0.62 m, height: 0.85 m) tests and finite element analyses (FEA) were conducted to investigate the main influencing factors on lateral displacement of a soft clayey ground under the combination of vacuum pressure and surcharge load. For the conditions investigated, the results indicate that the outward lateral displacement increases with the increase of the ratio of surcharge load to vacuum pressure (RL) and the loading rate of the surcharge load (LR). Also, it is shown that for a given RL and LR condition, lateral displacement reduces with the increase of the initial undrained shear strength (S u) of the ground. To predict the lateral displacement of a ground under the combination of surcharge load and vacuum pressure, the loading conditions in terms of RL and LR, and S u value of the ground have to be considered.  相似文献   

3.
Clogging effect surrounding prefabricated vertical drains (PVDs) is a typical problem when vacuum preloading is applied to a dredged fill foundation. A large-scale model test was designed to clarify the cause and mechanism of the clogging effect, and the basic physical and mechanical parameters of the soil in the clogging zone were tracked during the test. The results demonstrated that a clogging zone was formed around the PVD in the early stage of improvement with conventional vacuum preloading, and the boundary of the clogging zone was approximately 0.2–0.4 of the boundary radius. The clogging zone surrounding the PVD was formed because of the overall movement of the soil toward the PVD under the high vacuum pressure gradient, rather than fine particle migration. The soil in the clogging zone exhibited permeability anisotropy and equivalent ‘smear’ effect. The permeability ratio (kh/kv) was less than 1, and the ratio of horizontal permeability coefficients at the test distances of 45 cm and 10 cm were 9.6 at a depth of 20 cm and 8.9 at a depth of 80 cm. An analysis of the microstructure of the soil in the clogging zone demonstrated that the clay particles tended to be vertically oriented. The re-orientation of the clay particles reduced the horizontal permeability coefficient and led to the permeability anisotropy of the soil in the clogging zone. Thus, decrease in the horizontal permeability coefficient and equivalent ‘smear’ effect of the soil in the clogging zone affect the consolidation of dredged fill, which leads to the clogging effect. The permeability anisotropy also slightly affects consolidation.  相似文献   

4.
This paper presents the effectiveness of vacuum preloading in accelerating the consolidation of PVD improved soft Bangkok clay by comparing with the corresponding results without vacuum preloading. Laboratory tests were conducted using a large scale consolidometer having diameter of 300 mm and height of 500 mm with reconstituted specimens installed with prefabricated vertical drains (PVD) with and without vacuum preloading. In addition, field data were collected from Second Bangkok International Airport (SBIA) site improved by PVD with and without vacuum pressures. Analyses were carried out to compare the compressibility parameters (Ch and kh/ks) by back-calculation of laboratory and field settlements using Hansbo (1979) method. From the laboratory tests, the horizontal coefficient of consolidation (Ch) values from reconstituted specimens were 1.08 and 1.87 m2/yr for PVD without and with vacuum pressure, respectively and the kh/ks values were 2.7 for PVD only and 2.5 for vacuum-PVD. After the improvement, the water contents of the soft clay were reduced, thereby, increasing its undrained shear strengths. Similarly, the field data analysis based on the back-calculated results showed that the kh/ks were 7.2 and 6.6 for PVD without and with vacuum, respectively. The Ch values increased slightly from 2.17 m2/yr for PVD only to 3.51 m2/yr for vacuum-PVD. The time to reach 90% degree of consolidation for soils with vacuum-PVD was one-third shorter than that for soils with PVD only because of higher Ch values. Thus, the addition of vacuum pressure leads to increase horizontal coefficient of consolidation which shortened the time of preloading. The PVDCON software was found to be useful to predict the settlements of the PVD improved ground with and without vacuum preloading.  相似文献   

5.
为研究排水板在实际工况下的通水特性,研制排水板纵向通水量测试新仪器,采用室内真空预压模型试验、堆载预压模型试验和直接充灌淤泥等方法来制作板土单元体(试样),并开展板土单元体(试样)通水能力测试。试验结果表明:无论是直接充灌淤泥法、堆载预压法还是真空预压法,高性能排水板通水量均大于现行规程试验结果,而普通排水板通水量均小于现行规程试验结果,现行规程方法高估了真空预压后普通排水板的通水能力。对比结果表明:高性能排水板在堆载预压后通水能力与真空预压后通水能力接近,而普通排水板在堆载预压后通水能力明显高于真空预压后通水能力。因此,对于变形大且固结时间长的新近吹填淤泥地基加固工程应优先选用高性能排水板。  相似文献   

6.
Prefabricated vertical drains (PVDs) with embankment preloading (conventional PVDs) and with embankment combined with vacuum preloading (Vacuum-PVDs) are examined using the field data obtained from the site of the Suvarnabhumi Airport, Thailand. The flow parameters were back-analyzed by comparison of measured and predicted or simulated data. The flow parameters were illustrated in terms of the horizontal coefficient of consolidation (Ch) and the ratio between the horizontal hydraulic conductivity in undisturbed zone (kh) and the horizontal hydraulic conductivity in smear zone (ks) or (kh/ks). Numerical simulations using one-dimensional FEM PVDCON software with equivalent vertical permeability, kev, to determine the appropriate Ch and kh/ks of PVDs with conventional embankment preloading and with embankment combined with vacuum preloading schemes were made. Furthermore, numerical simulations using axisymmetric FEM by ABAQUS software, incorporating horizontal (kh) and vertical (kv) permeabilities, to determine the appropriate kh/ks based on back-calculated Ch of conventional PVD and Vacuum-PVD schemes were also done. The Vacuum-PVD scheme indicated faster rate of settlement than conventional PVD scheme by about 1.7–1.8 times with slight reduction of the kh/ks ratios. For conventional PVD, it was demonstrated that the increase in kh/ks ratios reduced the simulated rate of settlement.  相似文献   

7.
Reliably estimating soil vertical compression under vacuum loading is still challenging for geotechnical engineers. In this paper, the soil vertical compression within the prefabricated vertical drain (PVD)-improved zone under vacuum pressure was investigated based on the theoretical analysis, reported laboratory tests and the case histories. A theoretical equation was developed to evaluate the effect of lateral displacement on the soil vertical compression. The observed small overall lateral-to-vertical strain ratio at the perimeter of the PVD-improved zone soil showed that the vertical compression of PVD-improved zone was close to one-dimensional (1-D) state, but 1-D compression method yielded smaller predictions than the measurements from the case histories. The back-analyzed soil modulus of the natural soft clay in Shanghai Disneyland Resort project showed considerable degradation as compared to the corresponding constrained modulus from the laboratory test. Such degradation could be due to the soil disturbance caused by PVD installation. The 1-D compression method was modified by introducing two factors to consider the effect of soil lateral displacement and to correct the constrained modulus due to the soil disturbance caused by PVD installation, respectively. The recommendations were provided after applying the proposed method to a case history.  相似文献   

8.
This paper presents two well-instrumented large-scale field tests of PVD-improved soft soil with vacuum and surcharge preloading, respectively. The two large-scale field tests were conducted adjacent to each other with the same preload. A comparative analysis was performed to investigate the performance of subsoil (i.e., the ground settlement, the layered settlement, the lateral displacement of subsoil and pore water pressure) under vacuum preloading and equivalent surcharge preloading. Some design methods were verified based on the field data. Cone Penetration Tests (CPT) and Vane Shear Tests (VST) were conducted to assess the improvement effects on subsoil after preloading. The results showed that as compared with surcharge preloading, vacuum preloading mitigated the differential settlement of the ground. The vacuum pressure transmitted into the soil with a minor loss through the PVD length. From a practical point of view, the improvement effects by vacuum preloading and surcharge preloading were similar in terms of influence depth and soil strength based on the in-situ tests.  相似文献   

9.
The effectiveness of the prefabricated vertical drains (PVDs) in the consolidation of ultra-soft dredged soil with various soil water contents (W) in Mae Moh mine, Lampang, Thailand was researched via a series of large-scale model tests and numerical analysis. Large settlements with the delay of excess pore pressures is a distinct behavior of ultra-soft soil. The PVD dimensions were found to have a significant effect on the rate of consolidation and the delay of excess pore pressure at low total vertical stress (σv). The smaller PVD dimension resulted in the smaller rate of consolidation and longer delay of excess pore pressure. The undrained shear strength (Su) of ultra-soft clay at various degrees of consolidation could be approximated by the vertical effective stress (σv) based on the SHANSEP where the σv was determined from the Asaoka's observational method. The finite element analysis with axisymmetric and plane strain models showed that the axisymmetric model produced an excellent settlement prediction. However, the excess pore pressures were not well predicted by the axisymmetric model, due to the delay of excess pore pressures at the early stages of consolidation. In practice, the plane strain models proposed by Chai et al. and Indraratna and Redana's methods are suggested to predict the consolidation settlement of the Mae Moh dredged soil improved with PVD. The outcome of this research will facilitate the geotechnical design of reclamation of ultra-soft dredged soil in Mae Moh mine and other similar soils.  相似文献   

10.
Stabilising soft marine clay and estuarine soils via vacuum preloading has become very popular in Australasia over the past decades because it is a cost-effective and time-efficient approach. In recent times, new land on areas outside but adjacent to existing port amenities, the Fisherman Islands at the Port of Brisbane(POB), was reclaimed to cater for an increase in trade activities. A vacuum preloading method combined with surcharge to stabilise the deep layers of soil was used to enhance the application of prefabricated vertical drains(PVDs). This paper describes the performance of this combined surcharge fill and vacuum system under the embankment and also compares it with a surcharge loading system to demonstrate the benefits of vacuum pressure over conventional fill. The performance of this embankment is also presented in terms of field monitoring data, and the relative performance of the vacuum together with non-vacuum systems is evaluated. An analytical solution to radial consolidation with time-dependent surcharge loading and vacuum pressure is also presented in order to predict the settlement and associated excess pore water pressure(EPWP) of deposits of thick soft clay.  相似文献   

11.
Surcharge combined with vacuum preloading is a common technique for accelerating the consolidation process in ground improvement. A unit cell model for the axisymmetric consolidation of a soft soil using a prefabricated vertical drain (PVD) under a surcharge, combined with vacuum preloading, is investigated in this study. Based on this model, analytical solutions for a multi-layer soil system are put forward and the explicit expressions for two-layer and one-layer systems are presented. The accuracy of the proposed solution is verified using an analytical solution available in the literature. In the parametric study, the influencing factors on the consolidation process, such as, the smear zone, the PVD spacing, the hydraulic conductivity in the radial direction, the coefficient of vacuum decrease, are taken into account. The water flow in the radial direction plays an important role in the consolidation process while the impact of the vertical flow mainly develops around the interfaces between two adjacent layers. In addition, the proposed analytical solution is applied in a case history with three different layers and the results are reasonable.  相似文献   

12.
Prefabricated vertical drains (PVDs) with the surcharge preloading and vacuum consolidation has become considerably popular for ground improvement projects. A simple solution that incorporates the fundamental embankment features, such as the average degree of consolidation and excess pore pressure, are essential for the design of soft ground improvements by PVDs with vacuum preloading. However, most of the solutions for vertical drains with vacuum consolidation require numerical simulations, whose implementation tends to be laborious. In contrast, a simple solution for vacuum consolidation under time-dependent loading has not yet been proposed. In this study, a simple solution that can be easily incorporated into a conventional spreadsheet is derived for PVDs with vacuum preloading by applying the Laplace transform technique. The proposed solution accounts for several actual construction conditions, such as initial surcharge load, vacuum pump trial period, variations of radial permeability, and time-dependent loading. The results obtained from this proposed approach were validated with those from the finite element method and field data from the case study of the Cai Mep International Terminal project in southern Vietnam. The derived solutions, including the excess pore pressures and average degrees of consolidation, were in good agreement with the predicted and observed data.  相似文献   

13.
无砂真空预压吹填软土在国内造地工程中广泛应用,但实践表明传统固结解析解已不足以预测其加固性状和加固效果。从固结方程出发,在原有的等应变假设基础上,在定解条件中增加了吹填土特有的高度欠固结特性和无砂真空预压特别明显的真空度损耗,重新推导得到径向和竖向完全协调的新的等应变解析解——JJJ解答,以解决无砂真空预压吹填软土的排水固结设计理论问题。JJJ法作为固结方程的原生解答,兼容以往所有该类解析解的同时,增加了针对高度欠固结土类和排水板真空度损耗严重的排水固结问题的解决能力。经现场和试验验证,JJJ解析解可相当精确预测无砂真空预压吹填软土的复杂固结过程和加固土体超孔压分布和孔压消散分布,该解答同时也适用于堆载和真空预压的工况。  相似文献   

14.
The paper presents a numerical study on the undrained lateral response of a single, free-head, reinforced concrete pile in soft clays. Soil conditions simulating normally consolidated clays are examined—undrained shear strength increasing with depth—and the pile-soil interaction under static lateral loading is analyzed. The nonlinear p-y curves proposed in literature for soft clays are imported into a beam-on-nonlinear-Winkler-foundation simulation in order to predict the pile head lateral load—displacement curve and the distribution of the horizontal displacement and bending moment along the pile. The striking differences among these methods require further investigation via 3D finite element analyses. The determination of the ultimate soil resistance p ult from the results of the finite element analyses aims at providing the estimation of a range of values for the ultimate soil resistance coefficient N p with depth and the comparison of the derived values to the corresponding ones proposed by existing methodologies.  相似文献   

15.
An extensive program of laboratory model tests was undertaken to study the effect of slope on p-y curves due to surcharge load in dry sand. The paper concerns the method developed in a series of laboratory model tests to experimentally determine p-y curves. Bending moment curves are differentiated by using curve fitting method of cubic polynomial function. The study includes effect of slope angle and relative density on bending moment, lateral soil resistance, lateral deflection and non-dimensional p-y curves. The non-dimensional p-y curves for piles on sloping ground under surcharge load are developed modifying API RP 2A (2000) method by including a Reduction Factor (R) using the experimental results.  相似文献   

16.
Pile foundations are used to support both vertical and horizontal loads in many geotechnical projects, such as the coastal and offshore engineering. The responses of piles under vertical-horizontal combined loading are separately analyzed and then superposed in current design practice. This simplified analysis approach does not take the coupling effect of the combined loads into consideration. The research on this topic is limited and the results reported to date are inconclusive with regard to the influence of vertical loads on the horizontal response of piles. In this paper, a series of centrifuge model tests under different vertical-horizontal combined loading conditions was performed to investigate the influence rules and mechanism of the combined loads on the response of piles in sand. The vertical load is shown to densify the soil near the pile and therefore decrease the horizontal displacement and bending moment of the pile: this is termed the “soil densification effect”. The vertical load induces an additional bending moment of the pile due to the lateral deformation of the pile: this is termed the “P-Δ effect”. The soil densification effect plays a dominant role in the early horizontal loading while the P-Δ effect is strengthened as the horizontal loads increases. These compound effect of these two seemingly opposing effects is a decrease in the bending moment of the pile decrease first then increase as the horizontal load increases. Additional settlement of the pile is caused by horizontal loading and isa positively correlated with the pre-vertical loads.  相似文献   

17.
This paper presents the study of PVD improved reconstituted specimen with and without vacuum preloading on large-scale consolidometer in the laboratory tests. Subsequently, the results of the laboratory tests were analyzed and simulated by 2D (axisymmetric) finite element method (FEM) to back-analyze and confirm the related design parameters which were used further in subsequent numerical experiments. The laboratory test results indicated that the increased hydraulic conductivity in the smear zone of PVD with vacuum preloading (Vacuum-PVD) resulted in the increase in the coefficient of horizontal consolidation (Ch) by 16% as well as the decrease in the ratio between the horizontal hydraulic conductivity of the undisturbed zone (Kh) to the horizontal hydraulic conductivity in the smear zone (Ks) or (Kh/Ks) of about 10%. The Vacuum-PVD and PVD only have the same settlement magnitudes with similar equivalent loads.  相似文献   

18.
A series of centrifuge model tests was conducted on a nail-reinforced slope under vertical surface loading conditions considering different slope gradients and nail lengths. The ultimate load of the slope decreased significantly with the increasing gradient of the slope or the decreasing nail length. The slope exhibited significant progressive failure that was captured by a displacement-based analysis. At first, the vertical load caused local slippage near the slope toe and the inner edge of the loading plate. Then, it extended to the interior of the slope and eventually to an entire slip surface. The H-surface was obtained according to the measured displacement to distinguish the zone where the surface load influenced the horizontal displacement of the slope. The H-surface and the position where the peak vertical displacement occurred in a horizontal line moved from the internal slope to the slope surface from the slope top to the slope bottom. This demonstrates the dispersion of the surface load application within the slope. The deflections of nails can be obtained from the corresponding soil deformation. The deflection of nails increased with the increasing load pressure, and exhibited diverse features in its distribution in the upper and the lower parts of the slope.  相似文献   

19.
《Soils and Foundations》2007,47(4):783-797
This study concerns the determination of the seismic bearing capacity of a circular footing resting on a purely cohesive heterogeneous soil layer. The problem is treated using the kinematic approach of the Yield Design theory. The soil strength is modelled by the Tresca criterion with C0 the cohesion at the soil surface and G the vertical cohesion gradient. The loading process of the system is described by four loading parameters: an inclined force (N: vertical component, V: horizontal component), a moment (M) acting at the center of the footing and horizontal uniform inertial forces (Fh) acting in the soil volume during the seismic excitation. Two cases are considered for the soil: a soil with an infinite tensile strength and a soil with zero tensile strength. The soil-footing interface is considered purely cohesive with zero tensile strength. The study presents optimal upper bounds for the ultimate combinations of the dimensionless loading parameters (N, V, M, Fh) by the examination of a series of three-dimensional virtual kinematic mechanisms of failure. The results are presented in the form of surfaces in the space of the parameters (N, V, M) for a range of values of Fh.  相似文献   

20.
In this paper, an analytical method to compute the uplift capacity of an obliquely loaded horizontal strip anchor under both static and seismic conditions is described using the limit equilibrium method. The distribution of the soil reactions on a simple planar failure surface is obtained through the use of Kötter's equation, and the pseudo-dynamic approach is used to obtain the net seismic vertical uplift capacity factor for the unit weight component of the soil (Fγd). The results for the static and seismic vertical uplift capacity factors are determined for various combinations of input parameters, such as the load inclination, the soil friction angle, the embedment ratio, the soil amplification and both horizontal and vertical pseudo-dynamic seismic accelerations. It is observed that the orientation of the load significantly affects the seismic uplift capacity of the horizontal strip anchor. Fγd is seen to decrease with an increase in both horizontal and vertical seismic accelerations and soil amplification, whereas it is seen to increase with an increase in the embedment ratio and the soil friction angle, as expected. The results in terms of the non-dimensional net seismic uplift capacity factor are presented in graphical and tabular forms. The present results are compared and found to be in good agreement with similar results available in literature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号