首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The separation of various carboxylic acids was performed on a polymethacrylate-based weakly acidic cation-exchange resin (TSKgel OApak-A) using ion-exclusion chromatography under the acidic elution conditions. When a diluted sulfuric acid solution was used as the eluent, highly sensitive conductimetric detection of carboxylic acids was achieved without increasing the background conductance of the eluent. This method was more sensitive than using benzoic acid eluent and enabled a good resolution of dicarboxylic as well as monocarboxylic acids. The addition of 5–20% methanol to the eluent considerably reduced the retention times of carboxylic acids with hydrophobic nature.  相似文献   

2.
The determination of seven aliphatic carboxylic acids, formic, acetic, propionic, isobutyric, n-butyric, isovaleric and n-valeric acids in anaerobic digestion process waters was examined using ion-exclusion chromatography with conductimetric detection. The analysis of these biologically important carboxylic acids is necessary as a measure for evaluating and controlling the process. The ion-exclusion chromatography system employed consisted of polymethacrylate-based weakly acidic cation-exchange resin columns (TSKgel OApak-A or TSKgel Super IC-A/C). weakly acidic eluent (benzoic acid), and conductimetric detection. Particle size and cation-exchange capacity were 5 microm and 0.1 meq./ml for TSKgel OApak-A and 3 microm and 0.2 meq./ml for TSKgel Super IC-A/C, respectively. A dilute eluent (1.0-2.0 mM) of benzoic acid was effective for the high resolution and highly conductimetric detection of the carboxylic acids. The good separation of isobutyric and n-butyric acids was performed using the TSKgel Super IC-A/C column (150 mm x 6.0 mm i.d. x 2). The simple and good chromatograms were obtained by the optimized ion-exclusion chromatography conditions for real samples from mesophilic anaerobic digestors, thus the aliphatic carboxylic acids were successfully determined without any interferences.  相似文献   

3.
A simple, selective and sensitive method for the determination of carboxylic acids has been developed. A mixture of formic, acetic, propionic, valeric, isovaleric, isobutyric, and isocaproic acids has been separated on a polymethacrylate-based weak acidic cation-exchange resin (TSK gel OA pak-A) based on an ion-exclusion chromatographic mechanism with detection using UV-photodiode array, conductivity and atmospheric pressure chemical ionization mass spectrometry (APCI-MS). A mobile phase consisting of 0.85 mM benzoic acid in 10% aqueous methanol (pH 3.89) was used to separate the above carboxylic acids in about 40 min. For LC-MS, the APCI interface was used in the negative ionization mode. Linear plots of peak area versus concentration were obtained over the range 1-30 mM (r2=0.9982) and 1-30 mM (r2=0.9958) for conductimetric and MS detection, respectively. The detection limits of the target carboxylic acids calculated at S/N=3 ranged from 0.078 to 2.3 microM for conductimetric and photometric detection and from 0.66 to 3.82 microM for ion-exclusion chromatography-APCI-MS. The reproducibility of retention times was 0.12-0.16% relative standard deviation for ion-exclusion chromatography and 1.21-2.5% for ion-exclusion chromatography-APCI-MS. The method was applied to the determination of carboxylic acids in red wine, white wine, apple vinegar, and Japanese rice wine.  相似文献   

4.
2,6-Pyridinedicarboxylic acid (PDCA) was evaluated as an eluent for indirect UV and non-suppressed conductivity detection of carboxylic acids in ion-exclusion chromatography. The effect of PDCA concentration on the separation and detection sensitivity was investigated. The reasonable resolutions between carboxylic acids were achieved using 1 mM PDCA eluent. Detection limits were 1.0-7.0 microM for conductivity detection and 8-30 microM for UV detection. Compared to the eluent containing 1 mM sulfuric acid, the method offers a high resolution and high detection sensitivity for both detectors due to its high molar absorptivity and low background conductance. The proposed method was demonstrated to be useful for the determination of carboxylic acids in environmental samples with direct sample injection.  相似文献   

5.
This paper describes an ion-exclusion chromatographic system for the rapid and selective determination of ammonium ion. The optimized ion-exclusion chromatographic system was established with a polymethacrylate-based weakly basic anion-exchange resin column (TSKgel DEAE-5PW) as the separation column, an aqueous solution containing 0.05 mM tetramethylammonium hydroxide (pH 9.10) as eluent with conductimetric detection for the analyte determination. Under the optimum chromatographic conditions, ammonium ion was determined within 2.3 min with a detection limit (S/N=3) better than 0.125 microM. Ammonium ion in rain and river waters was precisely determined using this ion-exclusion chromatographic system.  相似文献   

6.
Ion-exclusion chromatography of aliphatic car☐ylic acids of different acidity (pKa) and hydrophobicity was investigated on a polystyrene-divinylbenzene (PS-DVB) based strongly acidic cation-exchange resin in the H+ form and conductivity detection by elution with polyvinyl alcohol (PVA). When water was used as an eluent, the resolution of the car☐ylic acids was very low and the peak accompanied a fronting depending on their hydrophobicities. Therefore, to improve the peak shape and the peak resolution, aqueous eluents containing PVAs (degrees of polymerization, n=500, 1500and2000) with many OH groups were tested for the ion-exclusion chromatographic separation of the car☐ylic acids. When aqueous eluents containing PVA were used, the fronting was decreased dramatically by the effect of increased hydrophilicity of the PS-DVB cation-exchange resin surface due to adsorption of OH group in PVA. The high resolution ion-exclusion chromatographic separation without the fronting and highly sensitive conductimetric detection of the car☐ylic acids was accomplished successfully by elution with a 0.2% PVA (n=1500)-10% methanol-water.  相似文献   

7.
Ion-exclusion chromatography has been successfully applied to the separation of a number of polyfluorocarboxylic acids. The separation of various mono- and dibasic polyfluorocarboxylic acids having a different alkyl group was investigated using a polymethacrylate-based weakly acidic cation-exchange resin (TSK gel OApak-A) in the H -form and conductimetric detection. When water was used as the eluent, polyfluorocarboxylic acids could not be resolved. When an aqueous solution of sulfuric acid, benzoic acid, o-phthalic acid, 1,3,5-benzenetricarboxylic acid, 1,2,4,5-benzenetetracarboxylic acid, and tartaric acid was used, the separation of polyfluorocarboxylic acids occurred for monobasic ones. While, for fluorine-containing dibasic acids, imperfect separation of peaks occurred. In order to improve their separation, the effect of an addition of organic modifiers such as methanol, 2,2,2-trifluoroethanol and 2H-hexafluoro-2-propanol in the eluent was also investigated.  相似文献   

8.
The addition of C1-C7 alcohols (methanol, ethanol, propanol, butanol, heptanol, hexanol and heptanol) to dilute sulfuric acid as eluent in ion-exclusion chromatography using a highly sulfonated styrene-divinylbenzene co-polymer resin (TSKgel SCX) in the H+ form as the stationary phase was carried out for the simultaneous separations of both (a) C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, isobutyric, butyric, isovaleric, valeric, 2-methylvaleric, isocaproic, caproic, 2,2-dimethyl-n-valeric, 2-methylhexanoic, 5-methylhexanoic and heptanoic acids) and (b) benzenecarboxylic acids (pyromellitic, hemimellitic, trimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic and salicylic acids and phenol). Heptanol was the most effective modifier in ion-exclusion chromatography for the improvement of peak shapes and a reduction in retention volumes for higher aliphatic carboxylic acids and benzenecarboxylic acids. Excellent simultaneous separation and relatively highly sensitive conductimetric detection for these C1-C7 aliphatic carboxylic acids were achieved on the TSKgel SCX column (150 x 6 mm I.D.) in 30 min using 0.5 mM sulfuric acid containing 0.025% heptanol as eluent. Excellent simultaneous separation and highly sensitive UV detection at 200 nm for these benzenecarboxylic acids were also achieved on the TSKgel SCX column in 30 min using 5 mM sulfuric acid containing 0.075% heptanol as eluent.  相似文献   

9.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

10.
The use of sulfonated cation-exchange resins based on hypercrosslinked polystyrene (HCPS) and highly cross-linked polystyrene–divinylbenzene (80% divinylbenzene) for the separation of organic acids was studied. The influence of the concentration of the eluent, temperature of the chromatographic column, and concentration of acetonitrile in the eluent on the retention of aliphatic carboxylic acids in ion-exclusion chromatography was examined. The optimal separation of organic acids on the HCPS sorbent is attained at 65°C with the use of 10 mM H2SO4with or without acetonitrile addition as the eluent. The sorbent based on HCPS in combination with spectrophotometric detection is promising for the determination of organic acids and other weakly ionized and neutral compounds with low molecular mass in samples of complex composition (juices and beer).  相似文献   

11.
Ion-exclusion chromatography has been successfully applied to the separation of a number of perfluoroalkylsulfinic acids and perfluoroalkylsulfonic acids. The separation of various perfluoroalkylsulfinic and perfluoroalkylsulfonic acids, with different alkyl groups, was investigated on a polymethacrylate-based, weakly acidic, cation-exchange resin (TSK gel OApak-A) in the H+-form and using conductimetric detection. When water was used as the eluent, these perfluoroalkylsulfinic and perfluoroalkylsulfonic acids could not be resolved. When an aqueous solution of benzoic acid and o-phthalic acid was used, the separation of each of these acids occurred. In order to improve their separation, the effect of the addition of methanol and 2,2,2-trifluoroethanol, as organic modifiers, was also investigated.  相似文献   

12.
The analysis of seven aliphatic carboxylic acids(formic,acetic,propionic,iso-butyric,n-butyric,iso-valeric and n-valeric acid) in anaerobic digestion process waters for biogas production was examined by ion-exclusion chromatography with dilute acidic eluents(benzoic acid,perfluorobutyric acid(PFBA) and sulfuric acid) and non-suppressed conductivity/ultraviolet(UV) detection.The columns used were a styrene/divinylbenzene-based strongly acidic cation-exchange resin column(TSKgel SCX) and a polymethacrylate-based weakly acidic cation-exchange resin column(TSKgel Super IC-A/C).Good separation was performed on the TSKgel SCX in shorter retention times.For the TSKgel Super IC-A/C,peak shape of the acids was sharp and symmetrical in spite of longer retention times.In addition,the mutual separation of the acids was good except for iso-and n-butyric acids.The better separation and good detection was achieved by using the two columns(TSKgel SCX and TSKgel Super IC-A/C connected in series),lower concentrations of PFBA and sulfuric acid as eluents,non-suppressed conductivity detection and UV detection at 210 nm.This analysis was applied to anaerobic digestion process waters.The chromatograms with conductivity detection were relatively simpler compared with those of UV detection.The use of two columns with different selectivities for the aliphatic carboxylic acids and the two detection modes was effective for the determination and identification of the analytes in anaerobic digestion process waters containing complex matrices.  相似文献   

13.
In this study, a cation-exchange resin (CEX) of the K+-form, i.e., an enhancer resin, is used as a postcolumn conductimetric enhancer in the ion-exclusion chromatography of aliphatic carboxylic acids. The enhancer resin is filled in the switching valve of an ion chromatograph; this valve is usually used as a suppressor valve in ion-exchange chromatography. An aliphatic carboxylic acid (e.g., CH3COOH) separated by a weakly acidic CEX column of the H+-form converts into that of the K+-form (e.g., CH3COOK) by passing through the enhancer resin. In contrast, the background conductivity decreases because a strong acid (e.g., HNO3) with a higher conductimetric response in an eluent converts into a salt (e.g., KNO3) with a lower conductimetric response. Since the pH of the eluent containing the resin enhancer increases from 3.27 to 5.85, the enhancer accelerates the dissociations of analyte acids. Consequently, peak heights and peak areas of aliphatic carboxylic acids (e.g., acetic acid, propionic acid, butyric acid, and valeric acid) with the enhancer resin are 6.3-8.0 times higher and 7.2-9.2 times larger, respectively, than those without the enhancer resin. Calibrations of peak areas for injected analytes are linear in the concentration range of 0.01-1.0 mM. The detection limits (signal-to-noise ratio = 3) range from 0.10 μM to 0.39 μM in this system, as opposed to those in the range of 0.24-7.1 μM in the separation column alone. The developed system is successfully applied to the determination of aliphatic carboxylic acids in a chicken droppings sample.  相似文献   

14.
A simple, sensitive and rapid ion-exclusion chromatographic method for the simultaneous separation of carbonic acid and short chain organic acids (formic acid, acetic acid, and propionic acid) has been developed. A weakly acidic cation exchange resin column TSKgel OApak-A was used for the separation; pure water, owing to its lower background conductance, was employed as eluent in order to obtain high detection sensitivity. A good separation of these weak acids was achieved in 16 min. The linear range of the peak area calibration curve for carbonic acid was from 3.0 mg/L to 500 mg/L. The conductivity detection limit calculated at S/N = 3 was 0.084 mg/L for carbonic acid. The method developed in this work was successfully applied to the determination of carbonic acid in several environmental water samples without any pretreatment.  相似文献   

15.
In this preliminary study, a new approach to ion-exclusion chromatography is proposed to overcome the relatively poor conductivity detection response which occurs in ion-exclusion chromatography when acids are added to the eluent in order to improve peak shape. This approach, termed vacancy ion-exclusion chromatography, requires the sample to be used as eluent and a sample of water to be injected onto a weakly acidic cation-exchange column (TSKgel OApak-A). Vacancy peaks for each of the analytes appear at the retention times of these analytes. Highly sensitive conductivity detection is possible and sharp, well-shaped peaks are produced, leading to efficient separations. Retention times were found to be affected by the concentration of the analytes in the eluent, and also by the presence of an organic modifier such as methanol in the eluent. Detection limits for oxalic, formic, acetic, propionic, butyric and valeric acids were 0.1, 0.2, 0.3, 0.3, 0.4 and 0.5 microM, respectively, and linear ranges for some acids extended over two orders of magnitude. Precision values for retention times were 0.21% and for peak areas were <1.90%. The vacancy ion-exclusion chromatography method was found to give detection responses four to 10 times higher than conventional ion-exclusion chromatography using sulfuric acid eluent and two to five times higher than conventional ion-exclusion chromatography using benzoic acid eluent.  相似文献   

16.
Vacancy ion-exclusion chromatography (VIEC) for inorganic acids such as H(2)SO(4), HCl, H(3)PO(4), HNO(3), HI and HF is tested on a polymethacrylate-based weakly acidic cation-exchange resin column in the H(+)-form. That is, mixture of inorganic acids in the mobile phase is adsorbed to the resin phase passing through the separation column, and each vacant peak induced by injecting water is determined. Retention times are dependent on the degrees of retention for each analyte in the resin phase. In VIEC, well-shaped peaks of inorganic acids are produced, leading to efficient separations. However, retention behaviors of inorganic acids were strongly affected by the concentrations of the acids in the mobile phase. Sulfosalicylic acid was mixed with inorganic acids in the mobile phase prior to the introduction of a separation column in order to obtain the well-resolutions in the lower concentrations of the acids. By using this method, the separations of inorganic acids could be achieved in the range of 0.01-1 mM, and the linear ranges could be extended over two-orders of magnitude. This is considered since the protonated carboxylic groups fixed on the resin phase were increased with increasing the acid concentrations in the mobile phase, and the penetration effects for the acids to the resin phase were thus enhanced. The detection limits (S/N=3) were below 1.0 microM for all analyte acids. Precision values for retention times were below 0.32% and for peak area were below 0.91%.  相似文献   

17.
The simultaneous ion-exclusion/cation-exchange separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin of 3 microm particle size was used to achieve the simultaneous high-speed separation of anions and cations (Cl(-), NO3(-), SO4(2-), Na(+), K(+), NH4(+), Ca(2+) and Mg(2+)) commonly found in environmental samples. The high-speed simultaneous separation is based on a combination of the ion-exclusion mechanism for the anions and the cation-exchange mechanism for cations. The complete separation of the anions and cations was achieved in 5 min by elution with 15 mM tartaric acid-2.5 mM 18-crown-6 at a flow-rate of 1.5 ml/min. Detection limits at S/N=3 ranged from 0.36 to 0.68 microM for anions and 0.63-0.99 microM for cations. This method has been applied to the simultaneous determination of anions and cations in several environmental waters with satisfactory results.  相似文献   

18.
Determination of aromatic carboxylic acids by conventional ion-exclusion chromatography is relatively difficult and methods generally rely on hydrophobic interaction between the solute and the resin. To overcome the difficulties in determining aromatic carboxylic acids a new approach is presented, termed vacancy ion-exclusion chromatography, which is based on use of the sample as mobile phase and an injection of aqueous 10% methanol onto a weakly acidic cation-exchange column (TSKgel OApak-A). Highly sensitive conductivity detection occurred with sharp and well-shaped peaks, leading to very efficient separations. The effects of sulfuric acid concentration added to the mobile phase, flow-rate, and column temperature on the retention volume of tested aromatic carboxylic acids was investigated. Retention times were found to be affected by the concentration of the analytes in the mobile phase and to some extent also by the addition of an organic modifier such as methanol to the injected water sample. Separation of sulfuric acid (SA), naphthalenetetracarboxylic acid (NTCA), phthalic acid (PA) and benzoic acid (BA) was satisfactory using this new approach. Detection limits were 0.66, 0.67, 0.42 and 0.86 microM and detector responses were linear in the range 1-100, 1-80, 2.5-100 and 10-40 microM, for SA, NTCA, PA and BA, respectively. Precision for retention times was 0.36% and for peak areas was 1.5%.  相似文献   

19.
Mori M  Tanaka K  Taoda H  Ikedo M  Itabashi H 《Talanta》2006,70(1):169-173
Ion-exclusion/adsorption chromatography of dimethylsulfoxide (DMSO) and its derivatives, i.e., methanesulfinic acid (MSI), methanesulfonic acid (MSA) and sulfuric acid (SA), was developed in order to clear the decomposition mechanism of DMSO on quality-test of TiO2-photocatalyst in water. The separation was achieved by the adsorption effect for DMSO and ion-exclusion effect for MSI, MSA and SA under optimum conditions, using a weakly acidic cation-exchange resin column with 20 mM succinic acid as the eluent. In this system, DMSO and MSI with UV at 195 nm and MSA and SA with conductivity detection were consecutively determined by single injection and single separation column. This method was used to monitor the artificial decomposition of DMSO induced by a photocatalyst. The concentration of DMSO by active oxygens (e.g., OH radical) generated from surface of photocatalyst was found to be decreased through the stoichiometric reaction in the order of MSI, MSA and SA.  相似文献   

20.
A new method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was investigated using high-performance ion-exclusion/cation-exchange chromatography with conductimetric detection on a separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the hydrogen-form and an eluent comprising 1.5 mM sulfosalicylic acid–6 mM 18-crown-6 at pH 2.6, operated at 1.5 ml/min. Effective separation and highly sensitive conductimetric detection for the anions and the cations was achieved in about 14 min. Since the ionic balance (equivalents of anions/equivalents of cations) of acid rain waters of different pH (4.40–4.67) ranged from 0.97 to 0.94, evaluation of the water quality of acid rain was possible. This method was successfully applied to the simultaneous determination of the anions and the cations in acid rain transported from mainland China and North Korea to central Japan monitored by a meteorological satellite data analyzer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号