首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
To provide possible laboratory support to health risk evaluation associated with long-term, low-intensity magnetic field exposure, 256 male albino rats and an equal number of control animals (initial age 12 weeks) were exposed 22 h/day to a 50 Hz magnetic flux density of 5 μmT for 32 weeks (a total of about 5000 h). Hematology was studied from blood samples before exposure to the field and at 12 week intervals. Morphology and histology of liver, heart, mesenteric lymph nodes, and testes as well as brain neurotransmitters were assessed at the end of the exposure period. In two identical sets of experiments, no significant differences in the investigated variables were found between exposed and sham-exposed animals. It is concluded that continuous exposure to a 50 Hz magnetic field of 5 μT from week 12 to week 44, which makes up ?70% of the life span of the rat before sacrifice, does not cause changes in growth rate, in the morphology and histology of liver, heart, mesenteric lymph nodes, testes, and bone marrow, in hematology and hematochemistry, or in the neurotransmitters dopamine and serotonin. © 1995 Wiley-Liss, Inc.  相似文献   

2.
Groups of adult male Sprague Dawley rats (64 rats each) were exposed for 8 months to electromagnetic fields (EMF) of two different field strength combinations: 5μT - 1kV/m and 100μT - 5kV/m. A third group was sham exposed. Field exposure was 8 hrs/day for 5 days/week. Blood samples were collected for hematology determinations before the onset of exposure and at 12 week intervals. At sacrifice, liver, heart, mesenteric lymph nodes, bone marrow, and testes were collected for morphology and histology assessments, while the pineal gland and brain were collected for biochemical determinations. At both field strength combinations, no pathological changes were observed in animal growth rate, in morphology and histology of the collected tissue specimens (liver, heart, mesenteric lymph nodes, testes, bone marrow), and in serum chemistry. An increase in norepinephrine levels occurred in the pineal gland of rats exposed to the higher field strength. The major changes in the brain involved the opioid system in frontal cortex, parietal cortex, and hippocampus. From the present findings it may be hypothesized that EMF may cause alteration of some brain functions. Bioelectromagnetics 19:57–66, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

3.
Adult male rats were exposed or sham-exposed to 60-Hz electric fields without spark discharges, ozone, or significant levels of other secondary variables. No effects were observed on body weights or plasma hormone levels after 30 days of exposure at an effective field strength of 68 kV/m. After 120 days of exposure (effective field strength = 64 kV/m), effects were inconsistent, with significant reductions in body weight and plasma levels of follicle-stimulating hormone and corticosterone occurring in one replicate experiment but not in the other. Plasma testosterone levels were significantly reduced after 120 days of exposure in one experiment, with a similar but not statistically significant reduction in a replicate experiment. Weanling rats, exposed or sham-exposed in electric fields with an effective field strength of 80 kV/m from 20 to 56 days of age, exhibited identical or closely similar growth trends in body and organ weights. Hormone levels in exposed and sham-exposed groups were also similar. However, there was an apparent phase shift between the two groups in the cyclic variations of concentrations of hormones at different stages of development, particularly with respect to follicle-stimulating hormone and corticosterone. We concluded that 60-Hz electric fields may bring about subtle changes in the endocrine system of rats, and that these changes may be related to alterations in episodic rhythms.  相似文献   

4.
Pregnant CD1 mice were exposed or sham-exposed from day 0 to day 17 of gestation to a 50 Hz sinusoidal magnetic field at 20 mT (rms). Preimplantation and postimplantation survival were assessed and fetuses examined for the presence of gross external, internal, and skeletal abnormalities. There were no statistically significant field-dependent effects on preimplantation or postimplantation survival, sex ratio, or the incidence of fetuses with internal or skeletal abnormalities. Magnetic field exposure was, however, associated with longer and heavier fetuses at term, with fewer external abnormalities. The results lend no support to suggestions of increased rates of spontaneous abortion or congenital malformation following prenatal exposure to power frequency magnetic fields. © 1994 Wiley-Liss, Inc.  相似文献   

5.
We conducted a pilot study to assess magnetic field levels in electric compared to gasoline‐powered vehicles, and established a methodology that would provide valid data for further assessments. The sample consisted of 14 vehicles, all manufactured between January 2000 and April 2009; 6 were gasoline‐powered vehicles and 8 were electric vehicles of various types. Of the eight models available, three were represented by a gasoline‐powered vehicle and at least one electric vehicle, enabling intra‐model comparisons. Vehicles were driven over a 16.3 km test route. Each vehicle was equipped with six EMDEX Lite broadband meters with a 40–1,000 Hz bandwidth programmed to sample every 4 s. Standard statistical testing was based on the fact that the autocorrelation statistic damped quickly with time. For seven electric cars, the geometric mean (GM) of all measurements (N = 18,318) was 0.095 µT with a geometric standard deviation (GSD) of 2.66, compared to 0.051 µT (N = 9,301; GSD = 2.11) for four gasoline‐powered cars (P < 0.0001). Using the data from a previous exposure assessment of residential exposure in eight geographic regions in the United States as a basis for comparison (N = 218), the broadband magnetic fields in electric vehicles covered the same range as personal exposure levels recorded in that study. All fields measured in all vehicles were much less than the exposure limits published by the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) and the Institute of Electrical and Electronics Engineers (IEEE). Future studies should include larger sample sizes representative of a greater cross‐section of electric‐type vehicles. Bioelectromagnetics 34:156–161, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

6.
Short-circuit currents, surface electric fields, and axial current densities were measured in electrically grounded guinea pigs exposed to a uniform, vertical, ELF electric field. These data are 70–110% of corresponding values obtained in grounded rats exposed to the same electric field.  相似文献   

7.
Numerous hematologic and serum chemistry variables were examined in rats exposed to unperturbed 60-Hz electric fields at 100 kV/m for 15, 30, 60, or 120 days. Each study was replicated once. Rigorous statistical evaluations of these data did not detect any consistent effect of the electric field for exposures of up to 120 days. It was, however, not unusual in any individual study to detect certain variables that were significantly different between the exposed and sham-exposed animals. This emphasizes the need for replicate designs and appropriate statistical analyses when investigating chemical or physical insults that may have minimal influence on biologic function.  相似文献   

8.
9.
A system is described that uses an oscillating magnetic field to produce power-frequency electric fields with strengths in excess of those produced in an animal or human standing under a high-voltage electric-power transmission line. In contrast to other types of exposure systems capable of generating fields of this size, no electrodes are placed in the conducting growth media: the possibility of electrode contamination of the exposed suspension is thereby eliminated. Electric fields in the range 0.02–3.5 V/m can be produced in a cell culture with total harmonic distortions less than 1.5%. The magnetic field used to produce electric fields for exposure is largely confined within a closed ferromagnetic circuit, and experimental and control cells are exposed to leakage magnetic flux densities less than 5 μT. The temperatures of the experimental and control cell suspensions are held fixed within ±0.1°C by a water bath. Special chambers were developed to hold cell cultures during exposure and sham exposure. Chinese hamster ovary (CHO) cells incubated in these chambers grew for at least 48 h and had population doubling times of 16–17 h, approximately the same as for CHO cells grown under standard cell-culture conditions.  相似文献   

10.
11.
Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32–95 Hz. When the rats were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface (where induced fields were maximal). Within the body, or in different directions relative to the applied field, the induced fields were reduced (reaching zero at the center of the animal). The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals. Bioelectromagnetics 18:317–323, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

12.
An acceleration of differentiation, at the expense of proliferation, is observed after exposure of various biological models to low frequency and low amplitude electric and electromagnetic fields. Following these results showing significant modifications, we try to identify the biological mechanism involved at the cell level through microarray screening. For this study, we use epidermis cultures harvested from human abdominoplasty. Two platinum electrodes are used to apply the electric signal. The gene expressions of 38,500 well‐characterized human genes are analyzed using Affymetrix® microarray U133 Plus 2.0 chips. The protocol is repeated on three different patients. After three periods of exposure, a total of 24 chips have been processed. After the application of ELF electric fields, the microarray analysis confirms a modification of the gene expression of epidermis cells. Particularly, four up‐regulated genes (DKK1, TXNRD1, ATF3, and MME) and one down‐regulated gene (MACF1) are involved in the regulation of proliferation and differentiation. Expression of these five genes was also confirmed by real‐time rtPCR in all samples used for microarray analysis. These results corroborate an acceleration of cell differentiation at the expense of cell proliferation. Bioelectromagnetics 32:28–36, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

13.
The effect of exposure to 50 Hz electromagnetic field on a human T-leukaemia cell line (Jurkat) was investigated by evaluating the reactive oxygen species (ROS) production and apoptosis, both spontaneous and induced by a specific anti Fas/CD95 monoclonal antibody (anti-Fas). Our results suggest that 1 h intermittent (5 min field on/10 min field off) exposure does not affect ROS formation, while a slight but statistically significant decrease of both spontaneous and anti-Fas-induced apoptosis was observed.  相似文献   

14.
Effects of the electromagnetic fields on living bodies, bones in particular, are among the relevant issues of contemporary life. In this study, we report the influences of 50 Hz and 0 Hz (static) electric fields (EF), on intact rat bones, as evaluated by dual energy X-ray absorbtion (DEXA) measurements on bone content and density when these animals (n = 27) are continuously exposed in utero and neonatally to EFs (10 kV/m) 14 days before and 14 days after their birth, for 28 days in total. Differences between 50 Hz EF and static EF groups are found to be significant (95% confidence level) for total bone mineral content (BMC), TBMC (P = .002). Differences between 50 Hz and control groups are found to be significant for total bone mineral density (BMD), TBMD (P = .002), lumbar BMC, LBMC (P = .023), and TBMC (P = .001). Differences between static EF and control groups are found to be significant for femoral BMD, FBMD (P = .009), TBMD (P = .002), LBMC (P = .001), and TBMC (P = .001). Note that TBMC parameters are jointly significant for all differences between the three groups of test animals. These results have shown that both static and 50 Hz EFs influence the early development of rat bones. However, the influence of static EFs is more pronounced than that of the 50 Hz field.  相似文献   

15.
16.
The facility consists of a 12 × 11.5 × 2.4 m high room containing six sets of exposure apparatus and the other equipment necessary to maintain a pathogen-free system. The apparatus sets produced 5 mT (rms), 0.5 mT, or a sham exposure. The apparatus was arranged in the room to minimize the fringing field of the 5 mT set at the sham position. Each set was 3.85 × 1.80 × 0.66 m in outside dimension, containing 24 cages in the magnetically homogeneous region. The apparatus was designed using Harvey's figure-eight-configuration and generated a horizontal sinusoidal alternating field. In order to save electric power, the coil of the apparatus constituted a 50 Hz LC resonance circuit with a condensor bank to which electric power was supplied to compensate losses. Magnetic flux density was kept constant by controlling the coil current. Although mild steel was used in the skeleton of the building, the fringing flux at the sham was as low as 0.1 to 1 μT. Stainless steel was used for ventilating ducts, racks for the cages, cage covers, feeder baskets, and watering nozzles. The homogeneity of the field was measured to be ± 10% in the animal residence area, and food and water consumption was found to be unaffected by the field. At 5 mT, the coil current was 370 A, and the hollow coil was cooled by a stream of 20°C water to prevent both heat and dew on the coil surface. Vibration and acoustic noise was prevented by fiber reinforced plastic framework of the coil. High harmonic distortion was not observed at the output terminal of the coil driver. The facility has operated without trouble for 2 years. © 1993 Wiley-Liss, Inc.  相似文献   

17.
This study tests the capacity of 50 Hz magnetic and electric fields to stimulate neurite outgrowth in PC-12D cells, a cell line which originated from a pheochromocytoma in rat adrenal medulla. The cells were plated on collagen-coated, plastic petri dishes and exposed to sinusoidal 50 Hz magnetic fields for 22 h in a 5% CO2 incubator at 37°C. Two 1,000 turn coils, 20 cm in diameter, were assembled in a Helmholtz configuration to generate a magnetic field in a vertical orientation, thereby inducing a companion electric field in the dish with intensity proportional to radius. A magnetic-field shield housed the control samples in the same incubator. Total cells and number of cells with neurites at least as long as one cell diameter or having a growth cone were counted within a radius of 0.3 cm of the dish center and within an annulus of 1.7–1.8 cm radii in 60 mm dishes, at 3.6 cm radius in 100 mm dishes, and between 1.9 and 2.1 cm radii in the outer well of organ culture dishes, which are physically separated into two concentric wells. Sham exposure demonstrated no difference in percentage of cells with neurites between the exposed and control locations in the incubator. Exposures were done at 4.0. 8.9, 22, 29, 40, 120, 236, and 400 milliGauss (mG). At dish radii of 1.7–1.8 cm in the 60 mm dishes these magnetic flux densities induced electric fields of 1.1, 2.5, 5.9, 8.1, 11, 33, 65, and 110 μV/m, respectively, while within a radius of 0.3 cm, the induced electric fields were less than 0.2, 0.4, 1.0, 1.5, 1.9, 6.0, 11, and 19 μV/m, respectively. For other dishes, the larger radii produced proportionally larger induced electric fields. At each field strength, there were two control dishes and four to nine exposed dishes: 100 or more cells were counted at each location on the dishes. The results demonstrate that magnetic fields stimulate neurite outgrowth in a flux-density-dependent manner between 22 and 40 mG, reaching an apparent stimulation plateau between 40 and 400 mG; no effects were seen at 8.9 mG or lower. There was no apparent neurite stimulation due to the electric field. Although relatively low intensity (?22mG) magnetic fields alone can stimulate a morphological response in a cell which is normally stimulated by nerve growth factor molecules binding to membrane receptors, the chemical basis of this response is unknown. © 1993 Wiley-Liss. Inc.  相似文献   

18.
Electric fields induced in a conductive body by the magnetic field of a current-carrying wire were analyzed theoretically and experimentally to assess the dosimetric importance of highly nonuniform, field-exposure conditions. Experimentation revealed that a 60-Hz magnetic field was inversely proportional to the radius of a wire bundle carrying 100 A within a 0.5-m2 test area. A miniaturized electric field probe was used to measure the electric fields induced in 5-cm-deep, saline-filled models. In the theoretical analysis, numerical estimates of induced fields were made by a spreadsheet method. The theoretical calculations and the measured values of induced electric fields were generally in good agreement. The induced fields were in a plane perpendicular to a vertically incident magnetic field; the maximally induced fields were in areas nearest the wire bundle. The strength of the induced field increased with model size: from 96 microV/cm in a 10 x 10 cm model to 176 microV/cm in a 40 x 40 cm model. The strength of the field induced in a 20 x 20 cm model decreased with increasing model-to-wire spacing: from 132 microV/cm for a 1-cm spacing (2-mT maximum, incident field) to 50 microV/cm for a 6-cm spacing (0.33-mT maximum). The results indicate that increases in local values of nonuniformly incident fields produce relatively small increases in induced electric fields. This finding may be important in dosimetric consideration of circumstances, such as use of electric blankets, in which fields of low average strength are accompanied by intense local fields.  相似文献   

19.
Dutch rabbits were acutely exposed to electromagnetic pulsed (EMP) fields (pulse duration 0.4μs, field strengths of 1–2 kV/cm and pulse repetition rates in the range of 10 to 38 Hz) for periods of up to two hours. The dependent variables investigated were pentobarbital-induced sleeping time and serum chemistry (including serum triglycerides, creatine phosphokinase (CPK) isoenzymes, and sodium and potassium). Core temperature measured immediately pre-exposure and postexposure revealed no exposure-related alterations. Over the range of field strengths and pulse durations investigated no consistent, statistically significant alterations were found in the end-points investigated.  相似文献   

20.
This human exposure study examined the relationship between field strength and biological response and tested whether the exposure levels at which the greatest effects occur differ for different endpoints. Three matched groups of 18 men each participated in two 6 h exposure test sessions. All subjects were sham exposed in one session. In the other session, each group of subjects was exposed at a different level of combined electric and magnetic field strength (low group: 6 kV/m, 10 μT; medium group: 9 kV/m, 20 μT; and high group: 12 kV/m, 30 μT). The study was performed double blind, with exposure order counterbalanced. Significant slowing of heart rate, as well as alterations in the latency and amplitude of event-related brain potential measures derived from the electro encephalogram (EEG), occurred in the group exposed to the 9 kV/m, 20 μT combined field (medium group). Exposure at the other field strength levels had no influence on cardiac measures and differential effects on EEG activity. Significant decrements in reaction time and in performance accuracy on a time estimation task were observed only in the low group. These results provide support for the hypothesis that humans may be more responsive to some combinations or levels of field strength than to others and that such differences in responsivity may depend, in part, on the endpoint of interest. © 1994 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号