首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Fourteen full-scale cover systems were constructed at a site in Cincinnati, Ohio, to understand better the strength capability of various GCLs as a component in cover systems. Four different geosynthetic clay liner (GCL) products were installed in full-scale cover systems on two different slopes. The main objective of the project was to monitor the internal shear strength of the GCLs over time. This required in-situ yet economic instrumentation. Instruments were designed, calibrated and installed in the test plots in order to monitor the moisture content of the subsoil and moisture content within the bentonite component of the GCL. In addition, total and differential deformations of the GCLs were monitored. The focus of'this paper is to report the details of instrumenting the GCLs rather than to report on specific GCL performance.  相似文献   

2.
土工膨润土防水毯(GCL)的内部剪切强度是影响复合防渗衬里边坡稳定性的关键因素,加筋纤维的存在使针刺GCL的内部剪切强度明显高于非加筋GCL。含水化GCL的复合防渗衬里结构剪切试验会发生应力小峰值现象,但大都被研究人员忽视;加筋纤维对GCL峰值剪切强度的贡献处于定性阶段。通过开展GCL内夹钠基膨润土的饱和剪切试验和理论分析,证实应力小峰值现象为水化针刺GCL应力位移曲线的固有特征,并且小峰值应力代表了GCL内夹膨润土的抗剪强度贡献。以应力位移曲线上的应力小峰值现象为基础,将加筋纤维对GCL峰值剪切强度的贡献定量化,结合破坏机理分析了针刺GCL内部剪切破坏和应力位移发展过程。考虑针刺GCL剪切强度各部分贡献,提出了一种能反映针刺GCL破坏机理的峰值强度准则。  相似文献   

3.
Geosynthetic clay liners (GCLs) are typically used for widening sections of an embankment. They are also used as low permeability liners to minimize water leakage from reservoirs such as irrigation ponds. However, few investigations have been carried out on the specific properties of GCLs, such as granulated bentonite sandwiched between geotextiles, their internal shear strength, and the shear strength at the interface between a GCL and an embankment body. In this study, a series of direct box shear tests were performed to determine the shear strength properties of bentonite and compacted soils as well as at the interface between a GCL and bentonite or compacted soil. In addition, a series of field-loading tests were conducted to investigate the failure behaviour of an embankment body containing a GCL when changes in the water content of the bentonite of the GCL in a real embankment occur. Furthermore, the stability of widened embankment bodies that incorporated GCLs were evaluated. The main conclusions of this study are as follows: (1) The shear strength of the interface between the covering soil and geotextiles varied according to the soil type, geotextile type, and the submergence period, (2) the maximum safety factor was observed at the interface between decomposed granite soil and the geotextiles, while the minimum safety factor was observed at the interface between the bentonite and the geotextiles, and (3) the influence of GCLs on the instability of a widened embankment was extremely small.  相似文献   

4.
This paper is the second of a two-paper set on stress-controlled direct shear testing of geosynthetic clay liners (GCLs). Design of the apparatus, preliminary experiments, and shear deformation mechanisms in heat-treated and non-heat treated needle-punched (NP) GCLs were discussed in Part I. The objective of Part II (this paper) was to evaluate the effects of physical factors (i.e., peel strength and initial normal stress, σni), environmental factors (i.e., temperature and hydration solution), and creep on the internal shear behavior of NP GCLs. In addition, failure conditions of GCLs in the stress-controlled direct shear tests were compared to displacement-controlled direct shear tests to verify results. An increase in internal shear strength developed from increased GCL peel strength or increased normal stress. Elevated temperatures were observed to decrease internal shear strength for both non-heat treated and heat-treated NP GCLs. Specimens hydrated with a calcium-rich synthetic mining solution experienced increased internal shear strength due to cation exchange in the bentonite, whereas specimens hydrated with a highly alkaline synthetic mining solution experienced decreased internal shear strength. Creep tests revealed an increase in time-to-failure with decrease in applied shear stress. Finally, stress states at failure from stress-controlled and displacement-controlled shear tests corresponded to a unique failure envelope, which validates the efficacy of using stress-controlled direct shear tests to assess internal shear behavior and shear strength of NP GCLs.  相似文献   

5.
The use of geosynthetic clay liners (GCLs) in waste containment applications can induce long-term normal and shear stresses as well as expose GCLs to elevated temperatures and non-standard hydration solutions. Considering the importance of GCL internal shear strength to the design and integrity of waste containment barrier systems, innovative laboratory testing methods are needed to assess shear behavior of GCLs. There were two main objectives of this study: (i) develop a stress-controlled direct shear apparatus capable of testing GCLs exposed to elevated temperatures and hydrated in non-standard solutions; and (ii) assess internal shear behavior of GCLs under varying experimental conditions (e.g., stress, temperature, solution). These two objectives were partitioned into a two-paper set, whereby Part I (this paper) focuses on the shear box design and Part II focuses on an assessment of shear behavior. The direct shear apparatus includes a reaction frame to mitigate specimen rotation that develops from an internal moment within needle-punched reinforced GCLs. Rapid-loading shear tests were conducted to assess functionality of the apparatus and document baseline shear behavior for a heat-treated and a non-heat treated needle-punched GCL with comparable peel strength. These two GCLs failed at comparable applied shear stress; however, the heat-treated GCL yielded lower shear deformation and failure occurred via rupture of reinforcement fiber anchors, whereas the non-heat treated GCL yielded larger shear deformation and failure via pullout of reinforcement fibers.  相似文献   

6.
A study was conducted to investigate (1) physicochemical factors that influence polymer elution from GCLs containing a blend of bentonite and linear (water-soluble) polymer (LPB GCLs) and (2) the mechanism that controls the chemical compatibility of LPB GCLs when polymer elutes. A series of hydraulic conductivity (k), free swell and viscosity tests were performed on a commercial LPB GCL using DI water, varying concentrations of NaCl and CaCl?. Comparable tests were also performed on a conventional bentonite (CB) GCL containing the same untreated bentonite and the same physical properties as the LPB GCL. The LPB GCL showed improved swelling and hydraulic performance compared to the CB GCL when permeated with salt solutions. Total organic carbon analysis of the effluents showed that polymer eluted from the LPB GCL regardless of the permeant solution. However, the rate at which polymer eluted increased as the concentration and valence of the dominant cation increased. The rate at which polymer eluted also increased with hydraulic gradient. The mass of polymer retained inside the GCL matrix did not correlate with the k of the LPB GCL. Free swell tests coupled with chemical analysis suggest that, the improved chemical compatibility of the LPB GCL was due to the ability of the polymer to scavenge cations from the solution which allows the bentonite to undergo adequate swelling during the initial hydration period. Analogous to water-prehydrated CB GCLs, the dispersed structure of the bentonite fabric and increased adsorbed water molecules attained during initial swelling controls the k of the LPB GCL when polymer elutes.  相似文献   

7.
A laboratory investigation of the interface transmissivity is reported for five different geosynthetic clay liners (GCLs) and a range of different geomembranes (GMBs) for a range of stresses from 10 to 150?kPa. The GCLs were prehydrated under normal stress before permeation. The GCLs examined comprised three multicomponent (a smooth coated, a smooth laminated, and textured coated) and two conventional (one with granular and one with powdered sodium bentonite) GCLs. The effect of a 4?mm circular defect in the coating of a multicomponent GCL directly below the 10?mm diameter hole in the GMB is investigated. The effect of GMB stiffness and texture is examined. Additionally, the effect of hydration and permeation of smooth coated GCL with highly saline solution and synthetic landfill leachate (SL3) is presented. It is shown that the 2-week interface transmissivity (θ2-week) can be one to two orders of magnitude higher than steady-state interface transmissivity (θ steady-state) at low stresses (10?kPa–50?kPa), whereas at high stresses (150?kPa) the variation is substantially less. For a smooth coated GCL hydrated and permeated with reverse osmosis (RO) water, GMB stiffness and texture has a limited effect on interface transmissivity when the coating is placed in contact with GMB at normal stresses of 10?kPa–150?kPa, whereas coating indentations result in much high interface transmissivity when placed in contact with GMB. GCL prehydration and permeation with highly saline solutions leads to higher interface transmissivity compared to RO water. With a 4.0?mm defect in the coating, the interface transmissivity between the coating and woven geotextile is higher than that between the coating and GMB for the stress levels and GCL examined.  相似文献   

8.
A modified osmotic suction control technique for monitoring apparent transient weight changes was successfully adapted to the wetting and drying paths of geosynthetic clay liners (GCLs). Reasonable control was possible, enabling suction equilibrium to be achieved without disruption to the test. The results provide unique insight into the time-dependent changes in water retention properties and the semi-permeable membrane behaviour of the bentonite component in GCLs. The stages of suction equilibrium, related to the tri-modal pore structure of GCLs and the point of capillary break, could also be monitored. While the osmotic method has been traditionally used to control matric suction (up to 10 MPa) in soils, the overall results presented in this paper indicate that its application for total suction control in GCLs is largely due to the membrane behaviour of their bentonite component. Furthermore, because of capillary break between the GCL and the osmotic solution at the water entry (or residual) suction value of a GCL, an upper limit of 2.8 MPa suction is recommended for the application of the osmotic method to measure the water retention properties of GCLs.  相似文献   

9.
The effect of a gravel subgrade on the hydraulic performance of GCLs is investigated. Laboratory test results show that the GCL specimens exhibit significant variation in thickness when compressed against gravel. The maximum and minimum thicknesses of the specimen were about 20 and 3 mm, respectively, after consolidation by an effective stress up to 138 kPa. However, the permittivity of GCLs remained very low. The permittivity of both needle-punched and adhesive-bonded geotextile-supported GCLs decreased with increasing confining stress, regardless of the type of subgrade materials. In general, larger particles led to more significant migration of bentonite. Nevertheless, there was no significant difference in the degree of bentonite migration between the two GCLs investigated.  相似文献   

10.
Water retention and hydration tests are reported for three needle punched geosynthetic clay liners (GCLs). GCLs hydration and their maximum hydration capacity were assessed against subgrade soils prepared at different initial gravimetric water contents. The subgrade soil mineralogy and particle size distribution, as well as the carrier geotextiles used in GCLs, are shown to have a significant impact on the GCLs hydration behaviour. This work highlights the need to consider the unsaturated properties of both the GCLs and the subgrade soil when assessing the hydration of the GCLs. At gravimetric water contents above the GCL water entry value (≈30%), some forms of GCL configuration may be better than others with respect to ability to hydrate from a given soil. However, the partial hydration of GCL is mostly controlled by the bentonite microstructure for gravimetric water contents below the water entry value of the GCLs.  相似文献   

11.
A laboratory investigation on the hydration behavior of GCLs from lateritic soils was conducted under isothermal and thermal conditions (tropical climate), varying subsoil moisture contents, GCLs bentonite particle size and mineralogy. GCL hydration levels from lateritic subsoils under isothermal conditions (55%) were similar to literature findings. A slight decrease in water content of some GCLs after long periods of contact with the lateritic soils indicates that equilibrium can demand long time in these soils. GCL with granular bentonites were less efficient to hydrate from lateritic subsoils. GCLs with activated-calcium bentonites maintained hydration levels in long-term. Nonwoven geotextile facing down favored capillary effects. Thermal cycles significantly influenced GCLs hydration from subsoils. Capillary connections developed during hydration under isothermal conditions due to suction gradient reductions. Post-hydration tests under isothermal conditions showed more alterations in GCLs swelling and cation exchange properties than thermal cycles test. An increase in the saturated hydraulic conductivity of GCLs was observed in both lateritic soils, mainly for isothermal condition, although continued attending hydraulic conductivity requirements for barrier applications.  相似文献   

12.
The effects of the silt aggregation, compaction density, and water content of the subgrade on the hydration of five different geosynthetic clay liner (GCL) products is reported based on a series of laboratory column experiments conducted over a six-year period. GCLs meeting typical specifications in terms of minimum hydraulic conductivity and swell index are hydrated to equilibrium from the same subgrade soil with sufficient cations to cause cation exchange during hydration. It is then shown that the GCL bentonite granularity and GCL structure can have a significant (~four orders of magnitude) effect on hydraulic conductivity under the same test conditions (from 8 × 10−12 m/s for one GCL to 6 × 10−8 m/s for another GCL product). The effect of subgrade water content on the hydraulic performance of GCLs are not self-evident and quite dependent on the bentonite granularity, GCL structure, and permeant. Varying the subgrade water content from 5 to 16% and allowing the GCL to hydrate to equilibrium before permeation led to up to 5-fold difference in hydraulic conductivity when permeated with tap water and up to 60-fold difference when the same product is permeated with synthetic municipal solid waste leachate. When permeated with synthetic leachate, increasing stress from 70 kPa to 150 kPa led to a slight (average 37%; maximum 2.7-fold) decrease in hydraulic conductivity due to a decrease in bulk void ratio. It is shown that hydraulic conductivity is lower for GCLs with a scrim-reinforced geotextile, and/or with finer bentonite. It is shown that selecting a GCL based on the initial hydraulic conductivity and swell index in a manufacturers product sheet provides no assurance of good performance in field applications and it is recommended that designers pay more attention to selection of a GCL and preparation of the subgrade for important projects.  相似文献   

13.
Geosynthetic clay liners (GCLs) are placed at the bottom of waste disposal facilities where they hydrate from the subsoil and eventually from a hydraulic head on geomembranes (GMs) defects. Predicting hydration behavior of GCLs requires knowledge of the water-retention properties of the GCL along wetting paths. Given that GCLs could be subjected to different ranges of vertical stresses that are induced by the weight of the supported waste, the confining stress could affect water-retention properties of GCLs and should be investigated. To do so, a laboratory methodology to establish the water-retention curves (WRCs) of needlepunched GCLs under stress was undertaken. Various constant vertical stresses corresponding to different weights of the supported waste were applied to GCL specimens placed in controlled-suction oedometers. Suction values were selected so as to mimic a wetting path from the initial dry state to zero suction. Suction was controlled by using controlled suction techniques with controlled humidity imposed by a saturated saline solutions and using the osmotic technique with polyethylene glycol (PEG) solutions. Measurements were undertaken on oedometer systems as to apply confining stresses and have been complemented by standard saturated oedometer swelling tests. The data obtained confirm that increasing the stress on to the GCL results in less, albeit faster, water uptake, which could emphasize on recommendations about rapidly covering GCLs after they are placed at the bottom of a waste disposal facilities. Finally, the potential validity of the state-surface concept, which was developed in unsaturated soil mechanics, is discussed using van Guenuchten's and Fredlund and Xing's equations for water retention curves.  相似文献   

14.
In composite liners made of geomembrane (GMB)-geosynthetics clay liners (GCLs), maintaining bentonite in the GCL in a suitably hydrated state is critical for their performance. Hydration of GCL from subsoil, following industry best practice, is time consuming and conditional on suitable water chemistry in subsoil. In addition, under thermal gradients, dehydration occurs, with moisture migrating downwards to the subsoil, leading to the development of cracks in the bentonite and hence loss of performance.Two novel ideas are proposed in this paper, namely hydration of GCLs by artificial irrigation and hydraulic separation of the liner system from the underlying subsoil. Three new composite liner designs allowing for actively irrigating a geosynthetic clay liner (GCL) through a geocomposite layer were investigated. In two of the three designs, the hydraulic connection between the GCL and the subsoil was broken by placing an additional GMB between them. The new designs were tested in column experiments under 20 kPa overburden pressure and temperatures of up to 78 °C applied to the top of the liner. The performances of the new designs were compared to that of a standard GCL-GMB design where GCL was allowed to hydrate from a well-graded sandy subsoil. Three scenarios for the staging of hydration and thermal load application were investigated.Under active hydration of the composite liners, it took less than 14 days for the GCLs to reach a gravimetric water content ω of 110–130%, compared to 49 days taken to reach ω~95% under hydration from the subsoil. GCLs in the new designs in which the hydraulic connection with the subsoil was broken, remained well-hydrated (ω>100%) after 14 days of heating and no cracks appeared in the bentonite. On the other hand, the GCL in the conventional design experienced severe desiccation under the same conditions. The new designs hence offer a viable solution to the problem of slow hydration and/or thermal desiccation of GCLs.  相似文献   

15.
Torsional ring shear tests were performed on composite specimens that simulate the field alignment of municipal solid waste (MSW) landfill liner and cover system components. Simultaneous shearing was provided to each test specimen without forcing failure to occur through a pre-determined plane. Composite liner specimens consisted of a textured geomembrane (GM) underlain by a needle-punched geosynthetic clay liner (GCL) which in turn underlain by a compacted silty clay. Hydrated specimens were sheared at eleven different normal stress levels. Test results revealed that shear strength of the composite liner system can be controlled by different failure modes depending on the magnitude of normal stress and the comparative values of the GCL interface and internal shear strength. Failure following these modes may result in a bilinear or trilinear peak strength envelope and a corresponding stepped residual strength envelope. Composite cover specimens that comprised textured GM placed on unreinforced smooth GM-backed GCL resting on compacted sand were sheared at five different GCL hydration conditions and a normal stress that is usually imposed on MSW landfill cover geosynthetic components. Test results showed that increasing the GCL hydration moves the shearing plane from the GCL smooth GM backing/sand interface to that of the textured GM/hydrated bentonite. Effects of these interactive shear strength behaviors of composite liner and cover system components on the possibility of developing progressive failure in landfill slopes were discussed. Recommendations for designing landfill geosynthetic-lined slopes were subsequently given. Three-dimensional stability analysis of well-documented case history of failed composite system slope was presented to support the introduced results and recommendations.  相似文献   

16.
Flow in an idealized geosynthetic clay liner (GCL) containing bentonite comprised of equisized and equispaced square granules was simulated using a hydrodynamic model to quantitatively evaluate the premise that the hydraulic conductivity of GCLs diminishes as the bentonite granules hydrate and swell into adjacent intergranular pores, creating smaller and tortuous intergranular flow paths. Predictions with the model indicate that hydraulic conductivity decreases as granules swell and intergranular pores become smaller, and that greater granule swelling during hydration is required to achieve low hydraulic conductivity when the bentonite is comprised of larger granules, or the bentonite density is lower (lower bentonite mass per unit area). Predictions made with the model indicate that intergranular pores become extremely small (<1 μm) as the hydraulic conductivity approaches 10−11 m/s. These outcomes are consistent with experimental data showing that GCLs are more permeable when hydrated and permeated with solutions that suppress swelling of the bentonite granules, and that the hydraulic conductivity of GCLs with bentonite having smaller intergranular pores (e.g., GCLs with smaller bentonite granules, more broadly graded particles, or higher bentonite density) is less sensitive to solutions that suppress swelling.  相似文献   

17.
《Soils and Foundations》2007,47(1):79-96
To investigate systematically the effects of electrolytic solutions on the barrier performance of geosynthetic clay liners (GCLs), a long-term hydraulic conductivity test for 3 years at longest was conducted on a nonprehydrated GCL permeated with inorganic chemical solutions. The hydraulic conductivity test for waste leachates was also conducted. The results of the test show that the hydraulic conductivity of GCLs significantly correlates with the swelling capacity of bentonite contained in GCLs. GCLs have excellent barrier performance of k<1.0×10-8 cm/s when the free swell is larger than 15 mL/2 g-solid regardless of the type and concentration of the permeant solution. In addition, when the results of the hydraulic conductivity test with chemical inorganic solutions were compared to those with waste leachates, the hydraulic conductivity of GCL permeated with chemical solution was almost the same within the electric conductivity of 0-25 S/m as that permeated with waste leachate having similar electric conductivity. The hydraulic conductivity of GCLs to be used in landfill bottom liners can be estimated by the hydraulic conductivity values obtained from the experiment using chemical solutions having the similar electric conductivity values, if the chemical solution had the electric conductivity within=25 S/m.  相似文献   

18.
The performance of five different GCLs (two GCLs with standard sodium bentonite and three GCLs with polymer enhanced bentonite) subjected to three different climatic modes of wet-dry cycles simulating conditions to which a GCL might expose in cover systems over a prolonged time is reported. The wetting cycles lasted for 8 h, while the drying cycles varied between 16 h, seven days, and 14 days. It is shown that after around a year of accelerated aging, the hydraulic conductivity of the aged GCLs increased notably when permeated with tap water at an applied effective stress of 15 kPa for a range of heads (0.07, 0.14, 0.21, 0.49, and 1.2 m). The combined effects of the number and the duration of the wet-dry cycles, the GCL's mass per unit area, the carrier geotextile, the size and the number of the needle punch bundles, and the thermal treatment to bond the needle-punch bundles to the carrier geotextile are discussed. The poor hydraulic performance of the polymer-amended/modified bentonite GCLs is discussed.  相似文献   

19.
This paper examines two needle-punched geosynthetic clay liners' water retention behaviour at high suction ranges using the vapour equilibrium technique where super-saturated salt solutions controlled the relative humidity. This study shows that the bentonite form and its mineralogy affect the absorption/desorption of GCLs and their corresponding water retention curves. In particular, a granular bentonite-based GCL was found to absorb more and release less water than a powdered bentonite-based GCL due to its higher montmorillonite content and larger pores. The water retention curves of both GCLs exhibited very little hysteretic behaviour at high suction. Repeated wetting-drying cycles shifted the WRCs of both GCLs slightly downward with minimal impact on their degree of hysteresis.  相似文献   

20.
The effect of water salinity on the water retention curve of geosynthetic clay liners (GCLs), under constant volume condition is examined. The results indicate that at a constant gravimetric moisture content the total suction increases as the salinity of the wetting liquid increases. Furthermore, the difference in total suction between the GCL hydrated by saline water and distilled water is greater than the difference in the osmotic potential of the wetting water. This behaviour is possibly caused by the matric suction being affected by the expected chemically induced pore size change of the bentonite component of the GCL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号