首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
One fundamental requirement for many lead optimization processes is the need for bioanalytical support within pharmaceutical drug discovery and development. Currently, most bioanalytical methods for pharmaceutical analysis employ HPLC coupled with MS/MS. The combination of HPLC and MS/MS detection frequently offers the complete resolution of the dosed compounds from their metabolites and the endogenous interferences to avoid extra efforts for chemical separation and sample clean-up procedures resulting in higher-throughput assays for a series of new chemical entities (NCEs). Hydrophilic interaction chromatography (HILIC) has been demonstrated to be a powerful technique for the retention of polar analytes offering a difference in selectivity compared to traditional RP chromatography. This review summarizes the HILIC-MS/MS methods for the trace quantitative determinations of the drug compounds and their metabolites to support both in vitro and in vivo experiments. The challenges on performing HILIC-MS/MS assays such as matrix ionization suppression and the potential for endogenous interferences are also presented.  相似文献   

2.
In the present study, hydrophilic interaction liquid chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) combined with tandem mass spectrometric detection (MS/MS) were evaluated and compared for the determination of donepezil, cetirizine and loratadine in human plasma, in terms of sensitivity and sample preparation procedure. A retention study for the above compounds of various polarities was performed, using both C(18) and silica columns, with several aqueous-organic mobile phase ratios, in order to investigate their retention mechanism profile under HILIC and RPLC. Both chromatographic conditions were compared for chromatographic analysis of plasma samples processed with a liquid-liquid extraction (LLE) method for donepezil determination, resulting in significantly higher sensitivity under HILIC. Furthermore, HILIC and RPLC were compared for direct injection, and novel methods including LLE, solid-phase extraction and protein precipitation protocols were developed. Direct injection technique significantly reduced sample preparation time, increasing at the same time method sensitivity. The current study contributes to broadening the range of analyzable compounds by HILIC-MS/MS to molecules of medium polarity.  相似文献   

3.
建立了牛奶和奶粉中三聚氰胺及其3种衍生物(三聚氰酸、三聚氰酸一酰胺、三聚氰酸二酰胺)的亲水色谱-串联质谱检测方法(HILIC-MS/MS)。牛奶样品直接用乙腈超声波提取;奶粉样品先用水溶解后再加乙腈超声波提取,高速离心后以乙腈-水为流动相,采用亲水作用色谱柱分离这4种化合物,在电喷雾正、负电离切换多反应监测模式下进行定性与定量分析,三聚氰酸一酰胺与三聚氰酸二酰胺含量在50~10000μg/kg之间、三聚氰胺与三聚氰酸在25~5000μg/kg之间,均获得良好的线性。方法检出限(LOD)为5~20μg/kg,定量下限(LOQ)为50~100μg/kg,3个添加水平的平均回收率为81%~97%。该方法简便、快速、准确,可满足牛奶及奶粉中三聚氰胺、三聚氰酸、三聚氰酸一酰胺、三聚氰酸二酰胺测定的需要。  相似文献   

4.
This paper presents a systematic study of the retention behavior of a model bisdioxopiperazine drug, dexrazoxane (DEX) and its three polar metabolites (two single open-ring intermediates-B and C and an EDTA-like active compound ADR-925) on different stationary phases intended for hydrophilic interaction liquid chromatography (HILIC). The main aim was to estimate advantages and limitations of HILIC in the simultaneous analysis of a moderately lipophilic parent drug and its highly polar metabolites, including positional isomers, under MS compatible conditions. The study involved two bare silica columns (Ascentic Express HILIC, Atlantis HILIC) and two stationary phases with distinct zwitterionic properties (Obelisc N and ZIC HILIC). The chromatographic conditions (mobile phase strength and pH, column temperature) were systematically modified to assess their impact on retention and separation of the studied compounds. It was found that the bare silica phases were unable to separate the positional isomers (intermediates B and C), whereas both columns with zwitterionic properties (Obelisc N and ZIC HILIC) were able to separate these structurally very similar compounds. However, only ZIC HILIC phase allowed appropriate separation of DEX and all its metabolites to a base line within a single run. A mobile phase composed of a mixture of ammonium formate (0.5 mM) and acetonitrile (25:75, v/v) was suggested as optimal for the simultaneous analysis of DEX and its metabolites on ZIC HILIC. Thereafter, HILIC-LC-MS analysis of DEX and all its metabolites was performed for the first time to obtain basic data about the applicability of the suggested chromatographic conditions. Hence, this study demonstrates that HILIC could be a viable solution for the challenging analysis of moderately polar parent drug along with its highly polar metabolites including the ability to separate structurally very similar compounds, such as positional isomers.  相似文献   

5.
A selective and sensitive HILIC‐MS/MS method for the simultaneous quantification of nicotine and its metabolites in human maternal and cord sera was developed and validated. After solid‐phase extraction, LC separation was achieved on a hydrophilic interaction chromatography. The validated method is capable of selective identification as well as accurate and sensitive quantification. Analyte recovery ranged from 86.2 to 107.7% and intra‐ and inter‐day assay precision were less than 15% relative standard deviation. This sensitive HILIC‐MS/MS method can be used to determine nicotine and its metabolic profile in smokers. This validated method is useful for the determination of nicotine and its metabolites in human serum in future studies of the effects of nicotine exposure on neonatal outcome. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
刘艳明  薛霞  刘国强  任雪梅  胡梅  祝建华 《色谱》2015,33(9):943-945
建立了亲水作用色谱-串联四极杆质谱测定乳及乳制品中左旋肉碱的分析方法。样品经2%(v/v)乙酸水溶液提取、乙腈沉淀蛋白质净化,以乙酸铵和乙腈为流动相,经Acquity UPLC BEH HILIC色谱柱分离后采用电喷雾质谱多反应监测(MRM)方式扫描,外标法定量。结果表明,左旋肉碱的质量浓度在1~100 μg/L范围内线性关系良好(r2> 0.99),定量限为0.01 mg/kg。标准加入法测定左旋肉碱在高、中、低3个加标水平的回收率为96.0%~103.4%,相对标准偏差(RSD)为1.2%~4.3%。该方法前处理简单、快速,检测结果准确、灵敏,可为各类乳及乳制品中左旋肉碱的含量水平测定、研究和控制提供技术支持。  相似文献   

7.
Hydrophilic interaction liquid chromatography (HILIC) interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of dasatinib, imatinib and nilotinib in mouse plasma samples. The retention profiles of all analytes on several silica stationary phases under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of all analytes in positive ion mode were investigated. The applicability of the proposed HILIC/MS/MS approach following a protein precipitation procedure for the quantitative determination of dasatinib, imatinib and nilotinib at low nano‐mole levels was examined with respect to assay specificity and linearity. The analytical results obtained by various HILIC/MS/MS approaches were found to be in good agreement with those obtained by reversed‐phase liquid chromatography/tandem mass spectrometry (RPLC/MS/MS) methods in terms of assay sample throughputs, sensitivity and accuracy. Furthermore, the potential of matrix ionization suppression on the proposed HILIC/MS/MS systems was investigated using the post‐column infusion technique. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Hydrophilic interaction LC with MS/MS (HILIC-MS/MS) was described as a rapid, sensitive, and selective method for the quantification of doxazosin in human plasma. Doxazosin and cisapride (internal standard) were extracted from human plasma with ethyl acetate at alkaline pH and analyzed on an Atlantis HILIC Silica column with the mobile phase of ACN/ammonium formate (100 mM, pH 4.5) (93:7 v/v). The analytes were detected using an ESI MS/MS in the selective-reaction-monitoring mode. The standard curve was linear (r = 0.9994) over the concentration range of 0.2-50 ng/mL. The LOQ for doxazosin was 0.2 ng/mL using 100 microL plasma sample. The CV and relative error for intra- and interassay at four QC levels were 3.7-8.7% and 0.0-9.8%, respectively. The matrix effect for doxazosin and cisapride were practically absent. The recoveries of doxazosin and cisapride were 67.4 and 61.7%, respectively. This method was successfully applied to the pharmacokinetic study of doxazosin in humans.  相似文献   

9.
Hydrophilic interaction liquid chromatography (HILIC) is here successfully coupled to negative-ion electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) for the analysis of synthetic and chemically modified oligonucleotides. Separation was performed on a 2.1 mm × 100 mm PEEK ZIC® HILIC column packed with hydrophilic stationary phase with a permanent zwitterionic functional group and a particle size of 3.5 μm with an average pore diameter of 200 Å. A method was developed to separate homogeneous and heterogeneous oligonucleotides as well as methylated oligonucleotides using a quaternary pumping system containing ammonium acetate and water with an acetonitrile gradient. Analyses of oligonucleotides were performed by LC/MS with a detection limit of 2.5 picomole (20 mer) with signal to noise ratio (S/N) of 4.12. The influence of the eluent composition, type of buffer and its concentration, and organic modifier were also evaluated. The HILIC LC/MS method presented in this paper used common, ‘MS friendly’, mobile phases achieving sensitive and selective oligonucleotide analysis.  相似文献   

10.
11.
亲水作用色谱固定相及其在中药分离中的应用   总被引:4,自引:0,他引:4  
郭志谋  张秀莉  徐青  梁鑫淼 《色谱》2009,27(5):675-681
亲水作用色谱(HILIC)作为一种分离极性化合物的液相色谱模式,近年来越来越受到关注和重视。一方面是因为强极性化合物的分离问题引起了各个研究领域的重视,如药物分析、代谢组学、蛋白质组学等研究领域都不同程度地涉及强极性化合物的分离问题;另一方面是由于HILIC具有流动相组成简单、分离效率较高、与质谱兼容以及反压较低等优势。固定相是HILIC发展和应用的基础,本文主要从固定相分子结构的角度对HILIC固定相的结构特征、保留特性以及应用概况等进行了综述。对传统正相色谱固定相用于HILIC以及专门设计的HILIC固定相进行了介绍,评述了各自的优缺点和应用概况;对近年来HILIC固定相在中药分离中的应用进行了介绍;并对HILIC固定相的发展进行了展望。  相似文献   

12.
Levosimendan (Simdax) is an approved drug in approximately 40 countries and currently in phase III clinical studies in the USA and Europe. An accurate, high-throughput and rugged assay is critical to support these clinical trials. Due to the mechanism of drug metabolism, the drug and its active metabolites often have significant differences in their chemical properties. In order to achieve high assay throughput and low sample volumes, a single bioanalytical assay for the drug and its metabolites is preferred. However, this need may prevent the optimization of both high-performance liquid chromatography (HPLC) and mass spectrometric ionization conditions. The chemical properties of levosimendan are significantly different from those of its two active metabolites, OR-1855 and OR-1896. Here, we present a novel strategy for high-throughput analysis of levosimendan and its metabolites. A 96-well liquid/liquid extraction procedure was developed for sample preparation. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) system with two separate mobile phases, shared backwash solvent and conditioning solvent, was developed to perform sequential LC separation for levosimendan and the metabolites. Levosimendan was eluted by 5 mM ammonium acetate in 33.3% acetonitrile and detected using negative ionization mode MS/MS monitoring. The metabolites were eluted by 5 mM ammonium acetate and 0.2% acetic acid in 20% acetonitrile and detected with positive ionization mode MS/MS monitoring. The method has been demonstrated to have excellent precision and accuracy, with high assay ruggedness during method validation and clinical sample analysis. The linear dynamic ranges were approximately 200-50,000 pg/mL for levosimendan and approximately 500-130,000 pg/mL for both metabolites. The coefficient of determination (r2) for all analytes was greater than 0.9985. The intra-assay %CVs for QC samples were from 0.9% to 2.0% for levosimendan, 0.9% to 3.2% for OR-1855, and 0.4% to 4.9% for OR-1896. The inter-assay %CVs for QC samples were from 1.2% to 1.8% for levosimendan, 1.3% to 2.7% for OR-1855, and 1.4% to 3.4% for OR-1896. The mean % biases for QC samples were from 1.5% to 5.5% for levosimendan, -1.4% to 2.6% for OR-1855, and -0.3% to 4.5% for OR-1896. By using a single extraction approach coupled with sequential LC/MS/MS analysis for levosimendan and its metabolites, the assay maintained high throughput and low sample volume usage.  相似文献   

13.
Asymmetric N(G),-N(G)-dimethylarginine (ADMA) increases in diseases such as renal failure, diabetes mellitus, and hypercholesterolemia. The feasibility and utility of a hydrophilic interaction chromatography (HILIC) method for the separation of free L-arginine (Arg), ADMA, and symmetric N(G),-N(G')-dimethylarginine (SDMA) on a typical silica column were explored and the impact of some experimental parameters on the chromatographic behavior of these analytes was investigated. The effect of water and TFA content in mobile phase and of column temperature was investigated during the development of a fast and simple HILIC-MS/MS method that might be suitable for the quantification of free Arg, ADMA, and SDMA in plasma for routine analysis. Our results show that a good compromise between efficiency and peak shape with acceptable retention and total chromatographic run time is achieved using an ACN/water (90:10) mobile phase with TFA% as additive ranging from 0.015 to 0.025% and column temperature ranging from 25 to 30 degrees C.  相似文献   

14.
Sun  Mingqian  Sun  Lei  Miao  Lan  Lin  Li  Huang  Shuo  Yang  Bin  Fu  Jianhua  Ge  Zhengyan  Jin  Long  Liu  Jianxun 《Chromatographia》2016,79(19):1309-1316

In this study, a metabonomics analysis of heart homogenates from myocardial ischemic rats was performed by LC–TOF–MS. Hydrophilic interaction chromatography (HILIC) was used to separate the endogenous metabolites in heart homogenates. Partial least squares to latent structure-discriminant analysis (PLS-DA) was used for data analysis. Good separations were observed between the normal and model groups and 15 potential biomarkers were identified. The major disturbed metabolic pathways were purine metabolism, pyrimidine metabolism, urea cycle, and energy metabolism. The results demonstrated that a metabonomics approach based on HILIC-MS was useful for studying metabolic mechanism on target tissue of the myocardial infarction rat.

  相似文献   

15.
刘永  唐英斐  宋金凤  胡志伟 《色谱》2014,32(2):139-144
在蔬菜种植中经常使用的有机磷农药马拉硫磷、甲基对硫磷、敌百虫及乙酰甲胺磷可能转化的主要代谢产物分别为O,O-二甲基二硫代磷酸酯、对硝基酚、敌敌畏及甲胺磷。根据蔬菜色素等基质的含量不同采用不同的净化方法,色素含量高的蔬菜采用活性炭和弗罗里硅土串联固相萃取小柱净化,其他蔬菜采用弗罗里硅土固相萃取小柱净化。色谱分离选择ACQUITY UPLC BEH HILIC色谱柱,以乙腈和5 mmol/L乙酸铵水溶液为流动相进行梯度洗脱,得到的分离效果较好;质谱采用电喷雾正或负离子电离、多反应监测模式检测。液相色谱-质谱检测的基质效应为15.3%~45.1%;4种有机磷农药及其代谢物的方法回收率为76.9%~102.8%,相对标准偏差为5.92%~10.19%;定量限范围为0.001~0.01 mg/L;在0.01~1.00 mg/L范围内线性相关系数为0.9982~0.9999。方法具有良好的回收率、相对标准偏差、定量限及线性关系,适合蔬菜中有机磷及代谢物的检测,应用该检测方法对农贸市场购买的白菜、辣椒、西红柿及洋葱进行了检测。  相似文献   

16.
亲水作用色谱-串联四极杆质谱测定液态奶中舒巴坦   总被引:1,自引:0,他引:1  
建立了亲水作用色谱-串联四极杆质谱测定液态奶中微量舒巴坦的分析方法。样品经0.2%乙酸水溶液提取,HLB固相萃取柱净化、富集,以甲酸铵-乙腈为流动相,经Acquity UPLC BEH HILIC色谱柱分离后采用电喷雾质谱多反应监测方式(MRM)扫描,外标法定量。结果表明,舒巴坦的质量浓度在1~100μg/L范围内线性关系良好,r2大于0.99,定量下限为1.0μg/kg。加标水平在1.0~50.0μg/kg范围时,回收率为82%~102%,相对标准偏差(RSD)为1.6%~4.7%。该方法前处理简便快捷、灵敏度高、回收率和重现性良好,适用于液态奶中舒巴坦的测定。  相似文献   

17.
A hydrophilic interaction chromatography (HILIC) and reverse‐phase liquid chromatography (RPLC) coupled with electrospray TOF MS method was developed for the analysis and characterization of constituents in the radix of Cyathula officinalis Kuan. Separation parameters of HILIC such as buffer pH, mobile phase strength, and organic modifier were evaluated. Fructose, glucose, and sucrose were identified by HILIC‐ESI/TOF MS. Reverse‐phase liquid chromatography‐ESI/TOF MS were applied for quick and sensitive identification of major saponins in Cyathula officinalis. In‐source collision‐induced dissociation has been performed to elucidate the fragmentation pathways of oleanane‐, hederagenin‐, and gypsogmin‐type saponins. Twelve saponins were characterized in this plant for the first time, and four of them were presumed to be new compounds. In addition, one phytoecdysteroid (cyasterone) and one coumarin (6,7‐dimethoxycoumarin) were detected at the same time. The present method was capable of rapid characterizing and providing structure information of constituents from herbal drugs.  相似文献   

18.
A hydrophilic interaction chromatographic (HILIC) system interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of nicotinic acid (NiAc) and its metabolites in dog plasma in support of a pharmacokinetic study. A silica column was adapted for separation of NiAc and its two metabolites, nicotinamide (NiNH2) and nicotinuric acid (NiUAc), under HILIC conditions. The influence of experimental factors such as the composition of mobile phase on ionization efficiency and chromatographic performance of all analytes was investigated. The feasibility of the proposed HILIC/MS/MS methods was explored by comparing the plasma levels of NiAc, NiNH2, and NiUAc in dog obtained by using either electrospray ionization or atmospheric pressure chemical ionization interfaces in positive ion mode. The methods were partially validated in terms of inter-day accuracy and precision, extraction recovery, benchtop and freeze/thaw stability. Further, the potential of ionization suppression resulting from endogenous components of the biological matrixes on the HILIC/API-MS/MS methods were investigated using the post-column infusion technique.  相似文献   

19.
Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.  相似文献   

20.
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI‐MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile–ammonium formate (10 mm , pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号