首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
激光重熔纳米氧化锆热障涂层的抗热冲击性能   总被引:2,自引:1,他引:1       下载免费PDF全文
采用纳米氧化锆团聚粉末和等离子喷涂技术制备了纳米氧化锆涂层,试验研究了激光重熔工艺参数(激光比能量)对纳米氧化锆涂层抗热冲击性能的影响.试验结果表明,激光重熔工艺参数对重熔涂层的抗热冲击性能影响显著,采用合适的工艺参数(激光比能量),可以使重熔涂层获得最佳的抗热冲击性能.不同激光重熔工艺参数处理的涂层形成的组织结构不同,使得涂层的抗热冲击性能不同.合适的激光重熔工艺参数下涂层表现出高的抗热冲击性能,主要是因为重熔后的涂层组织结构有利于热应力的释放以及其相结构在高温冲击下具有良好的稳定性.  相似文献   

2.
Nanostructured zirconia top coat was deposited by air plasma spray and NiCoCrAlTaY bond coat was deposited on Ni substrate by low pressure plasma spray.Nanostructured and conventional thermal barrier coatings were heat-treated at temperature varying from 1050 to 1 250oC for 2-20 h.The results show that obvious grain growth was found in both nanostructured and conventional thermal barrier coatings(TBCs)after high temperature heat treatment.Monoclinic/tetragonal phases were transformed into cubic phase in the agglomerated nano-powder after calcination.The cubic phase content increased with increasing calcination temperature.Calcination of the powder made the yttria distributed on the surface of the nanocrystalline particles dissolve in zirconia when grains grew.Different from the phase constituent of the as-sprayed conventional TBC which consisted of diffusionlesstransformed tetragonal,the as-sprayed nanostructured TBC consisted of cubic phase.  相似文献   

3.
采用多种方法制备不同类型的Al2O3-13%TiO2热障涂层,即等离子喷涂常规涂层、纳米结构涂层及激光熔覆纳米结构涂层.在分析三类涂层微观组织的基础上,对其隔热性能进行了比较.结果表明,即等离子喷涂常规陶瓷涂层呈典型的层状堆积特征,纳米结构涂层都为特殊的两相结构,其中部分熔化区由类似的残留纳米粒子组成,等离子喷涂纳米结构涂层的完全熔化区为片层状结构,而相应的激光熔覆涂层的完全熔化区则为细小等轴晶.在相同条件下,等离子喷涂纳米结构热障涂层具有最好的隔热性能,而激光熔覆纳米结构涂层的隔热性能要好于等离子喷涂常规涂层.  相似文献   

4.
采用大气等离子喷涂技术制备了纳米氧化锆热障涂层和常规热障涂层.利用FESEM和XRD对纳米氧化锆热障涂层的组织结构和物相组成进行分析.系统研究了两种热障涂层的抗热冲击性能.微观组织分析结果表明,纳米氧化锆热障涂层展现出独特的纳米—微米复合结构,包括柱状晶和未熔融或部分熔融纳米颗粒.非平衡四方相是涂层的主要物相.抗热冲击性能试验结果表明,纳米氧化锆热障涂层拥有更为优越的抗热冲击性能,这主要得益于其相对致密的结构以及微裂纹、纳米晶粒、小孔径孔隙的应力缓释作用.热应力失效是涂层失效的主要原因.  相似文献   

5.
6.
Phase composition in an air plasma-sprayed Y2O3-stabilized ZrO2 (YSZ) top coating of a thermal barrier coating (TBC) system was characterized. Both the bulk phase content and localized pockets of monoclinic zirconia were measured with Raman spectroscopy. The starting powder consisted of ∼15 vol.% monoclinic zirconia, which decreased to ∼2 vol.% in the as-sprayed coating. Monoclinic zirconia was concentrated in porous pockets that were evenly distributed throughout the TBC. The pockets resulted from the presence of unmelted granules in the starting powder. The potential effect of the distributed monoclinic pockets on TBC performance is discussed.  相似文献   

7.
Anisotropic thermal conductivities of the plasma-sprayed ceramic coating are explicitly expressed in terms of the microstructural parameters. The dominant features of the porous space are identified as strongly oblate (cracklike) pores that tend to be either parallel or normal to the substrate. The scatter in pore orientations is shown to have a pronounced effect on the effective conductivities. The established quantitative microstructure-property relations, if combined with the knowledge of the processing parameters-resulting microstructure connections, can be utilized for controlling the conductivities in the desired way.  相似文献   

8.
Acoustic emission has been used as a nondestructive evaluation technique to examine the thermal shock response of thermal barrier coatings. In this study, samples of partially stabilized zirconia powder were sprayed and acoustic emission (AE) data were taken in a series of thermal shock tests in an effort to correlate AE with a given failure mechanism. Microstructural evidence was examined using parallel beam x-ray diffraction and optical microscopy. The AE data are discussed in terms of cumulative amplitude distributions and the use of this technique to characterize fracture events.  相似文献   

9.
The oxidation and hot corrosion behaviors of HVAF-sprayed conventional and nanostructured NiCrC coatings were studied. The oxidation experiment was conducted in air, and the hot corrosion was conducted in the Na2SO4–30%K2SO4 environment, in the temperature range of 550–750 °C for periods up to 160 h. The corrosion kinetics was tested with the thermogravimetric method. The corrosion products were characterized by scanning electron microscopy(SEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffractometry (XRD). As indicated by the results, both types of coatings possess high corrosion resistance, especially the nanostructured NiCrC coating. The enhanced grain boundary diffusion in the nanostructured coating not only promotes the formation of a denser Cr2O3 scale with a higher rate, but also helps to mitigate the Cr depletion at the metal/scale interface. The less porosity of the nanostructured coating is also thought to be beneficial to the anti-corrosion properties.  相似文献   

10.
Several studies have been undertaken recently to adapt yttria partially stabilized zirconia (YPSZ) thermal barrier coating (TBC) characteristics during their manufacturing process. Thermal spraying implementing laser irradiation appears to be a possibility for modifying the coating morphology. This study aims to present the results of in situ (i.e., simultaneous treatment) and a posteriori (i.e., post-treatment) laser treatments implementing a high-power laser diode. In both cases, the coatings underwent atmospheric plasma spraying (APS). Laser irradiation was achieved using a 3 kW, average-power laser diode exhibiting an 848 nm wavelength. Experiments were performed to reach two goals. First, laser post-treatments aimed at building a map of the laser-processing parameter effects on the coating microstructure to estimate the laser-processing parameters, which seem to be suited to the change into in situ coating remelting. Second, in situ coating remelting aimed at quantifying the involved phenomena. In that case, the coating was treated layer by layer as it was manufactured. The input energy effect was studied by varying the scanning velocity (i.e., between 35 and 60 m/min), and consequently the irradiation time (i.e., between 1.8 and 3.1 ms, respectively). Experiments showed that coating thermal conductivity was lowered by more than 20% and that coating resistance to isothermal shocks was increased very significantly.  相似文献   

11.
Thermal barrier coatings (TBCs), consisting of physical vapor deposited (PVD) partially stabilized zirconia (PSZ, 8 wt.%Y2O3) and a diffusion aluminide bond coat, were characterized as a function of time after oxidative isothermal heat treatment at 1373 K in air. The experimental characterizations was conducted by X-ray diffraction analysis and scanning electron microscopy (SEM) with energy-dispersive spectroscopy. During cooling to room temperature, spallation of the PSZ ceramic coatings occurred after 200 and 350 h of isothermal heat treatment. This failure was always sudden and violent, with the TBC popping from the substrate. The monoclinic phase of zirconia was first observed on the bottom surface of the PVD PSZ after 200 h of isothermal heat treatment. The failure of TBCs occurred either in the bond coat oxidation products of αAl2O3 and rutile TiO2 or at the interface between the oxidation products and the diffusion aluminide bond coat or the PSZ coating.  相似文献   

12.
The influence of secondary hydrogen and current on the deposition efficiency (DE) and microstructure of yttria-stabilized zirconia (YSZ) coatings was evaluated. To better understand the influence of the spray process on coating consistency, a YSZ powder, −125 +44 μm, was sprayed with nitrogen/hydrogen parameters and a 9 MB plasma gun from Sulzer Metco. DE and coating porosity, which were produced using two different spray gun conditions yielding the same input power, were compared. Amperage was allowed to vary between 500 and 560 A, and hydrogen was adjusted to maintain constant power, while nitrogen flow was kept at a fixed level. Several power conditions, ranging from 32 to 39 kW, were tested. Different injection geometries (i.e., radial with and without a backward component) were also compared. The latter was found to produce higher in-flight temperatures due to a longer residence time of the powder particles in the hotter portion of the plasma. Porosity was based on cross-sectional micrographs. In-flight particle temperature and velocity measurements were also carried out with a special sensor for each condition. Test results showed that DE and coating density could vary significantly when a different hydrogen flow rate was used to maintain constant input power. On the other hand, DE was found to correlate very well with the temperature of the in-flight particles. Therefore, to obtain more consistent and reproducible DE and microstructures, it is preferable to maintain the in-flight particle temperature around a constant value instead of keeping a constant input power by adjusting the secondary hydrogen flow rate.  相似文献   

13.
Thermal shock characteristics of plasma sprayed mullite coatings   总被引:2,自引:0,他引:2  
Commercially available mullite (3Al2O3·2SiO2) powders containing oxides of calcium and iron as impurities, have been made suitable for plasma spraying by using an organic binder. Stainless steel substrates covered with Ni-22Cr-10Al-1.0Y bond coat were spray coated with mullite. The 425 μm thick coatings were subjected to thermal shock cycling under burner rig conditions between 1000 and 1200 °C and less than 200 °C with holding times of 1, 5, and 30 min. While the coatings withstood as high as 1000 shock cycles without failure between 1000 and 200 °C, spallation occurred early at 120 cycles when shocked from 1200 °C. The coatings appeared to go through a process of self erosion at high temperatures resulting in loss of material. Also observed were changes attributable to melting of the silicate grains, which smooth down the surface. Oxidation of the bond coat did not appear to influence the failure. These observations were supported by detailed scanning electron microscopy and quantitative chemical composition analysis, differential thermal analysis, and surface roughness measurements.  相似文献   

14.
This research aims to develop advanced thermal plasma spraying technology for the next-generation thermal barrier coatings (TBCs) with a high power hybrid plasma spraying system. By using thermal plasma physical vapor deposition (TP-PVD), various functional structured yttria-stabilized zirconia (YSZ) coatings were deposited. Parameters, such as powder feeding rate, hydrogen gas concentration, and total mass flow rate of the plasma gas, were optimized, and their influences on the evaporation of YSZ powder were investigated. Ultrafast deposition of a thick coating was achieved at a rate of over 150 μm/min. The deposited porous coating has a low thermal conductivity of 0.7W/mK and the dense coating with interlaced t′ domains possesses a high nanohardness of 27.85 GPa and a high reflectance. These characteristics show that the TP-PVD technique is a very valuable process for manufacturing novel TBCs.  相似文献   

15.
In application as a thermal barrier coating (TBC), partially stabilized zirconia (Zr) approaches some limits of performance. To further enhance the efficiency of gas turbines, higher temperature capability and a longer lifetime of the coating are needed for the next generation of TBCs. This paper presents the development of new materials and concepts for application as TBC. Materials whose compositions have the pyrochlore structure or doped Zr are presented in contrast with new concepts like nanolayers between the top and bond coat, metal-glass composites, and double-layer structures. In the last concept, the new compositions are used in a combination with Zr, as a double, multi, or graded layer coating. In this case, the benefits of Zr will be combined with the promising properties of the new top coating. In the case of metal-glass composites, the paper will be focused on the influences of different plasma spraying processes on the microstructure. The performance of all these different coating systems has been evaluated by burner rig tests. The results will be presented and discussed.  相似文献   

16.
The conductivity of a thermal-barrier coating composed of atmospheric plasma sprayed 8 mass percent yttria partially stabilized zirconia has been measured. This coating was sprayed on a substrate of 410 stainless steel. An absolute, steady-state measurement method was used to measure thermal conductivity from 400 to 800 K. The thermal conductivity of the coating is 0.62 W/(m×K). This measurement has shown to be temperature independent.  相似文献   

17.
等离子喷涂热障涂层的隔热性分析   总被引:4,自引:0,他引:4  
采用大气等离子喷涂方法制备不同类型的氧化钇部分稳定氧化锆热障涂层:传统涂层、纳米团聚粉末制备的纳米涂层和空心球粉末制备的空心球涂层。通过扫描电镜、透射电镜、压汞仪和激光脉冲法观察和测试各种涂层的组织形貌、空隙分布和导热系数,并在相同条件下测试各种涂层的隔热性能。结果表明:纳米涂层空隙率最低,内部孔洞细小。空心球涂层组织相对疏松,内部层片更薄,有最高的空隙率和最大的平均空隙大小。传统涂层介于二者之间。纳米涂层和传统涂层均表现出双态空隙大小分布。涂层的导热系数均随着温度的上升而升高。传统涂层的热导率最高,纳米涂层与空心球涂层的热导率相接近。纳米涂层具有最好的隔热性能,空心球涂层接近纳米涂层的隔热效果。隔热效果与涂层厚度呈线性关系。随着厚度增加,导热系数低的纳米涂层和空心球涂层的隔热效果增长幅度高于传统涂层。  相似文献   

18.
Gas turbines provide one of the most severe environments challenging material systems nowadays. Only an appropriate coating system can supply protection particularly for turbine blades. This study was made by comparison of properties of two different types of thermal barrier coatings (TBCs) in order to improve the surface characteristics of high temperature components. These TBCs consisted of a duplex TBC and a five layered functionally graded TBC. In duplex TBCs, 0.35 mm thick yittria partially stabilized zirconia top coat (YSZ) was deposited by air plasma spraying and ~0.15 mm thick NiCrAlY bond coat was deposited by high velocity oxyfuel spraying. ~0.5 mm thick functionally graded TBC was sprayed by varying the feeding ratio of YSZ/NiCrAlY powders. Both coatings were deposited on IN 738LC alloy as a substrate. Microstructural characterization was performed by SEM and optical microscopy whereas phase analysis and chemical composition changes of the coatings and oxides formed during the tests were studied by XRD and EDX. The performance of the coatings fabricated with the optimum processing conditions was evaluated as a function of intense thermal cycling test at 1100 °C. During thermal shock test, FGM coating failed after 150 and duplex coating failed after 85 cycles. The adhesion strength of the coatings to the substrate was also measured. Finally, it is found that FGM coating has a larger lifetime than the duplex TBC, especially with regard to the adhesion strength of the coatings.  相似文献   

19.
The influence of bond coat composition on the spallation resistance of plasma-sprayed thermal barrier coatings (TBCs) on single-crystal René N5 substrates was assessed by furnace thermal cycle testing of TBCs with various vacuum plasma spray (VPS) or air plasma-spray (APS) MCrAlX (M=Ni and/or Co; and X=Y, Hf, and/or Si) bond coats. The TBC specimens with VPS bond coats were fabricated using identical parameters, with the exception of bond coat composition. The TBC lifetimes were compared with respect to MCrAlX composition (before and after oxidation testing) and MCrAlX properties (surface roughness, thermal expansion, hardness, and Young’s modulus). The average TBC spallation lifetimes varied significantly (from 174 to 344 1 h cycles at 1150 °C) as a function of bond coat composition. Results suggested a relationship between TBC durability and bond coat thermal expansion behavior below 900 °C. Although there were only slight differences in their relative rates of cyclic oxidation weight gain, VPS MCrAlX bond coats with better oxide scale adhesion provided superior TBC lifetimes.  相似文献   

20.
ZrO2-7 wt.% Y2O3 plasma-sprayed (PS) coatings were applied on high-temperature Ni-based alloys precoated by physical vapor deposition with a thin, dense, stabilized zirconia coating (PVD bond coat). The PS coatings were applied by atmospheric plasma spraying (APS) and inert gas plasma spraying (IPS) at 2 bar for different substrate temperatures. The thermal barrier coatings (TBCs) were tested by furnace isothermal cycling and flame thermal cycling at maximum temperatures between 1000 and 1150 °C. The temperature gradients within the duplex PVD/PS thermal barrier coatings during the thermal cycling process were modeled using an unsteady heat transfer program. This modeling enables calculation of the transient thermal strains and stresses, which contributes to a better understanding of the failure mechanisms of the TBC during thermal cycling. The adherence and failure modes of these coating systems were experimentally studied during the high-temperature testing. The TBC failure mechanism during thermal cycling is discussed in light of coating transient stresses and substrate oxidation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号