首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Complex matrices and rather high acidity in environmental samples are often the impelling challenges for the used running buffers of capillary electrophoresis. Twelve binary acid-base buffers were evaluated for separation of Cr(VI)/Cr(III), Co2+ and Zn2+ in a sample containing various salts by capillary electrophoresis with contactless conductivity detector. The malic acid (MA) systems including MA-His (histidine), MA-Arg (arginine) and MA-Tris (tris(hydroxymethyl)aminomethane) were selected as the candidates with powerful separation efficiency and good response sensitivity. In the MA-Tris buffer, optimization were further carried out in terms of the pH value and the concentration of MA, and the optimal conditions were obtained as 6 mM MA-Tris and 2 mM 18-crown-6 at pH 3.5. Furthermore, a real application was demonstrated by analyzing the plating rinse water (pH 0.8), in which the Ca2+, Na+, Cr(VI)/Cr(III), Co2+ and Zn2+ were all detected by adjusting at pH 3.5 with 5% (v/v) diluent ammonia. Both the cations, e.g., K+, Ca2+, Na+, Mg2+, and the common high concentration anions in the sample, e.g., Cl, SO42− and NO3 did not cause any disturbance to the concerned analytes.  相似文献   

2.
Iridium oxide nanoparticles are grown on a glassy carbon electrode by electrodepositing method. The electrochemical behavior and electrocatalytic activity of modified electrode towards reduction of iodate and periodate are studied. The reductions of both ions occur at the unusual positive peak potential of 0.7 V vs. reference electrode. The modified electrode is employed successfully for iodate and periodates detection using cyclic voltammetry, hydrodynamic amperometry and flow injection analysis (FIA). In the performed experiments, flow injection amperometric determination of iodate and periodate yielded calibration curves with the following characteristics: linear dynamic range up to 100 and 80 μM, sensitivity of 140.9 and 150.6 nA μM−1 and detection limits of 5 and 36 nM, respectively. The repeatability of the modified electrode for 21 injections of 1.5 μM of iodate solution is 1.5%. The interference effects of NO2, NO3, ClO3, BrO3, ClO4, SO42−, Cu2+, Zn2+, Mn2+, Mg2+, Cd2+, Ca2+, Na+, K+, NH4+ and K+, CH3COO and glucose were negligible at the concentration ratio of more than 1000. The obtained attractive analytical performance together with high selectivity and simplicity of the proposed method provide an effective and e novel modified electrode to develop an iodate and periodate sensor. Sensitivity, selectivity, the liner concentration range and the detection limit of the developed sensor are all much better than all known similar sensors in the literature for iodate and periodate determination.  相似文献   

3.
The paper presents a new method for a simultaneous determination of inorganic nitrogen species in the oxidized (NO2, NO3) and reduced (NH4+) form in rain water samples. The method is based on a system of nitrogen species separation employing ion exchange and diode-array detection. The ions are separated in a strong ion-exchanger, nitrites and nitrates are determined directly at 208 and 205 nm, respectively, while the ammonium ions are determined in the column hold-up time after a post-column derivatization by the Nessler reagent, at 425 nm. The use of a diode-array detector permits a simultaneous identification of the inorganic nitrogen species in 8 min. The detection limits obtained are: NO2, 0.1 mg L−1; NO3, 0.05 mg L−1; NH4+, 1 mg L−1. The method proposed has been successfully used for speciation analysis of inorganic nitrogen in precipitation.  相似文献   

4.
The present paper deals with data interpretation of monitoring of various atmospheric events (cloud water, aerosol and rainwater) at three different elevation levels at Achenkirch profile in an Alpine valley, Tyrol, Austria (Christlumkopf-1758 m, Christlumalm-1280 m and Talboden-930 m a.s.l.) by the use of principal components analysis. From October 1995 to September 1996 sampling sessions for all sites from the profile and for all events were performed for the major ions NH4+, Na+, K+, Ca2+, Mg2+, Cl, NO3, SO42−-44 cases with eight variables for rainwater; 117 cases with eight variables for cloud water samples and 50 cases with seven variables for aerosol (the major ions as in rain- and cloud water but without magnesium) at any of the elevations. The aim of the multivariate statistical treatment was to extract information about latent factors determining the data structure in all of the cases in order to compare and interpret similarities and dissimilarities with respect to the elevation or the type of the atmospheric event. Four latent factors seem to explain over 85% of the total variance for almost all sites and events but the factors have different identification for the different events or sites (e.g. ‘anthropogenic’, ‘crustal’, ‘neutralization’, ‘salt’). Thus, a comparison between sites and between events becomes possible. It was found that cloud water and aerosol events are much more similar with respect to data structure (relevant to emission sources or processes of formation) than the same events and rainwater. Further, the upper sites of the profile (Christlumkopf and Christlumalm) also reveal data structure similarity differing from that of the lowest site Talboden.  相似文献   

5.
Crea F  Milea D  Sammartano S 《Talanta》2005,65(1):229-238
In order to analyze the formation of hetero-metal polynuclear hydrolytic species, in this paper, we reported some results of an investigation (at I = 0.16 mol L−1 in NaNO3, at t = 25 °C by potentiometry, ISE-H+, glass electrode) on the hydrolysis of several mixtures (in different ratios) of two couples of cations: dioxouranium(VI)/copper(II) and dioxouranium(VI)/diethyltin(IV). The elevated total concentrations of cations 0.005 ≤ ΣCM mol L−1 ≤ 0.05) adopted in these measurements induced us to study again the hydrolysis of uranyl, for which no suitable literature data are available in these particular experimental conditions. All measurements were performed by two different operators, using completely independent instruments and reagents. Many different speciation models were considered in the calculations, including the simultaneous refinement of homo- and hetero-metal species, and a statistical analysis of obtained results was proposed too. Main results can be summarized as follows: UO22+ and Cu2+ form three hetero-metal polynuclear hydrolytic species [(UO2)Cu(OH)3+, (UO2)Cu2(OH)2+ and (UO2)2Cu4(OH)2+, with log βpqr = −2.93 ± 0.01, −7.34 ± 0.03 and −13.78 ± 0.03, respectively], all those common to their simple speciation without the other cation; UO22+ and (C2H5)2Sn2+ form seven mixed hydrolytic species [(UO2)(DET)(OH)3+, (UO2)(DET)2(OH)2+, (UO2)2(DET)4(OH)2+, (UO2)(DET)24(OH)2+, (UO2)2(DET)+5(OH), (UO2)(DET)2+5(OH) and (UO2)2(DET)7(OH), with log βpqr = −2.5 ± 0.2, −4.74 ± 0.02, −10.70 ± 0.06, −10.34 ± 0.03, −15.70 ± 0.06, −15.58 ± 0.06 and −27.9 ± 0.1, respectively] that are of the same kind of those formed by uranyl; formation of mixed hydrolytic species causes a significant enhancement of the percentage of hydrolyzed metal cations, modifying the solubility and, therefore, the bioavailability of these cations. We also determined, for dioxouranium(VI)/copper(II) system, the corresponding complex formation enthalpies and entropies by direct calorimetric measurements. We obtained ΔH112 = 47.9 ± 0.6 and ΔH214 = 92.9 ± 0.5 kJ mol−1, TΔS112 = 6 ± 1 and TΔS214 = 14 ± 1 kJ mol−1 (±S.D.), respectively, for the formation of (UO2)(Cu)2(OH)2+ and (UO2)2(Cu)4(OH)2+ species (according to reaction 2). We also calculated the single enthalpic and entropic contributes to the extra-stability that these species show with respect to the corresponding homo polynuclear ones.  相似文献   

6.
A gas chromatography–tandem mass spectrometric (GC–MS/MS) method has been established for the determination of cyanide in surface water. This method is based on the derivatization of cyanide with 2-(dimethylamino)ethanethiol in surface water. The following optimum reaction conditions were established: reagent dosage, 0.7 g L−1 of 2-(dimethylamino)ethanethiol; pH 6; reaction carried out for 20 min at 60 °C. The organic derivative was extracted with 3 mL of ethyl acetate, and then measured by using GC–MS/MS. Under the established conditions, the detection and quantification limits were 0.02 μg L−1 and 0.07 μg L−1 in 10-mL of surface water, respectively. The calibration curve had a linear relationship relationship with y = 0.7140x + 0.1997 and r2 = 0.9963 (for a working range of 0.07–10 μg L−1) and the accuracy was in a range of 98–102%; the precision of the assay was less than 7% in surface water. The common ions Cl, F, Br, NO3, SO42−, PO43−, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+, Fe2+ and sea water did not interfere in cyanide detection, even when present in 1000-fold excess over the species. Cyanide was detected in a concentration range of 0.07–0.11 μg L−1 in 6 of 10 surface water samples.  相似文献   

7.
Enass M. Ghoneim 《Talanta》2010,82(2):646-652
A simple and precise square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for simultaneous determination of Mn(II), Cu(II) and Fe(III) in water samples using a carbon paste electrode. In 0.1 mol L−1 acetate buffer (pH 5) containing 50 μmol L−1 of 2-(5′-bromo-2′-pyridylazo)-5-diethylaminophenol (5-Br-PADAP), Mn(II), Cu(II) and Fe(III) were simultaneously determined as metal-complexes with 5-Br-PADAP following preconcentration onto the carbon paste electrode by adsorptive accumulation at +1.0 V (vs. Ag/AgCl/3 M KCl). Insignificant interference from various cations (K+, Na+, Mg2+, Ca2+, Al3+, Bi3+, Sb3+, Se4+, Zn2+, Ni2+, Co2+, Cd2+, Pb2+, V5+, Ti4+ and NH4+), anions (HCO3, Cl, NO3−, SO42− and PO43−) and ascorbic acid was noticed. Limits of detection of 0.066, 0.108 and 0.093 μg L−1 and limits of quantitation of 0.22, 0.36 and 0.31 μg L−1 Mn(II), Cu(II) and Fe(III), respectively, were achieved by the described method. The described stripping voltammetry method was successfully applied for simultaneous determination of Mn(II), Cu(II) and Fe(III) in ground, tap and bottled natural water samples.  相似文献   

8.
A robotic method has been established for the determination of bromate in sea water and drinking deep-sea water. Bromate in water was converted into volatile derivative, which was measured with headspace solid-phase micro extraction and gas chromatography–mass spectrometry (HS-SPME GC–MS). Derivatization reagent and the HS-SPME parameters (selection of fibre, extraction/derivatization temperature, heating time and; the morality of HCl) were optimized and selected. Under the established conditions, the detection and the quantification limits were 0.016 μg L−1 and 0.051 μg L−1, respectively, and the intra- and inter-day relative standard deviation was less than 7% at concentrations of 1.0 and 10.0 μg L−1. The calibration curve showed good linearity with r2 = 0.9998. The common ions Cl, NO3, SO42−, HPO42−, H2PO4, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+ and Fe2+ did not interfere even when present in 1000-fold excess over the active species. The method was successfully applied to the determination of bromate in sea water and drinking deep-sea water.  相似文献   

9.
A sensitive and highly selective spectrophotometric method is described for the determination of cyanide. It is based on a reaction of cyanide with aquacyanocobyrinic acid heptamethyl ester (ACCbs) reagent (orange color) at pH 9.5 to give dicyanocobester (DCCbs) (violet color). The increase of the absorption bands of the reaction product at 368 and 580 nm and the decrease of the reagent band at 353 nm are linearly proportional to the cyanide concentration. The method is used in static mode for determining cyanide over the concentration range 0.04-1.20 μg ml−1 with a detection limit of 0.02 μg ml−1 and for hydrodynamic analysis of 0.4-5.2 μg ml−1 cyanide. Application for batch and flow injection monitoring of cyanide in electroplating wastewater samples gives results agree within ± 1.2% with those obtained by the standard potentiometry using the cyanide ion selective electrode. The method is practically free from interferences by PO43−, NO3, NO2, SO42−, F, Cl, Br, I, S2− and SCN ions and gives results with average recoveries of 97.6-99.2%. Advantages offered by using ACCbs as a chromogen for cyanide assay are: (i) high selectivity and sensitivity of the coordination site of the reagent towards cyanide ion; (ii) fast reaction, since legation takes place at the axial position of the reagent; (iii) good solubility and stability of the reagent in aqueous solutions over a wide pH range; (iv) high stability of the reagent (ACCbs) and the colored complex product (DCCbs) and (v) possible absorbance measurements at three different wavelengths.  相似文献   

10.
The use of ion chromatography (IC) in conjunction with ultrasonic extraction is described for the routine analysis of water-soluble major inorganic ions and organic acids in atmospheric fine particles (PM2.5). Both the extraction method and the IC analysis were validated using NIST SRM 1648 (urban particulate matter). In addition, the reliability of the IC method was established by intercomparison of results obtained with those from suitable alternative analytical techniques (atomic absorption spectrometry (AAS), proton-induced X-ray emission (PIXE) spectrometry, and UV-Visible spectrophotometry). The validated IC method was successfully applied for field monitoring of PM2.5 particles collected in Singapore over an extended period of time. The IC analysis revealed that the concentrations of individual ions were in the order, SO42− > NH4+ > NO3 > Na+ > K+ > Cl, respectively. Among the major ionic components, SO42− contributed 50% to the measured water-soluble aerosol mass followed by NH4+ (16.5%) and NO3 (9.0%). The cations Na+, K+, Mg2+, and Ca2+ accounted for 24% of the total water-soluble mass. The IC analysis was performed to quantify the organic acids, which typically account for a small fraction of water-soluble organic compounds in PM2.5. Oxalate was found to be the dominant species among the organic acids measured in this work.  相似文献   

11.
In this paper, we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl, NO3, SO42−, Na+, NH4+, Mg2+, Ca2+) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM10 and PM2.5 identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP.  相似文献   

12.
Studies of IR and Raman spectra of monohydrates MI2[MIIICl5(H2O)] (where MI=K+, Rb+, Cs+ and MIII=Fe3+, In3+) at 1400-1900 cm−1 have been carried out. The medium intensity band, detected in the region 1580-1595 cm−1 was assigned to bending vibrations of water molecules (δHOH). The shift of the δHOH band towards low wavenumbers (1580-1595 cm−1) is a main sign of the water molecule interactions in the chain hydrates. Additionally in the IR and Raman spectra of these salts, the appearance of the low intensity band between 1750 and 1810 cm−1 (νx(H2O)) was observed. In the presented paper we also discuss the influence of MI and MIII cations on the position and splitting of these bands.  相似文献   

13.
Pipes are the primary structural elements used for transporting fluid in various industries. The most common damage mechanism is corrosion, which occurs in pipes surface of turbine. The corrosive compounds for pipes are inorganic ion (Na+, Cl?, NH4+, NO3?, etc.) and grinding oil. For rapid and quantitative detection of inorganic ions on site, more reliable and reproducible analytical methods are demanded. A highly efficient solid–liquid sampling collection system is introduced in this work. Papering on the sample surface, inorganic cations and anions were simultaneously collected and analyzed by capillary electrophoresis with indirect ultraviolet detection. As a result, five cations (Na+, K+, NH4+, Ca2+, Mg2+) and three anions (Cl?, NO3?, SO42?) were completely separated. The efficiency of the sampling and ability of capillary electrophoresis analysis were presented by the determination of trace‐level (mg/m2) contaminants. The recoveries of cations and anions on the paper from metal surface were between 86.6 and 107.2%, and the relative standard deviations were less than 12.85%.  相似文献   

14.
A recently developed atmospheric pressure ionization source, a distributed plasma ionization source (DPIS), was characterized and compared to commonly used atmospheric pressure ionization sources with both mass spectrometry (MS) and ion mobility spectrometry (IMS). The source consisted of two electrodes of different sizes separated by a thin dielectric. Application of a high RF voltage across the electrodes generated plasma in air yielding both positive and negative ions. These reactant ions subsequently ionized the analyte vapors. The reactant ions generated were similar to those created in a conventional point-to-plane corona discharge ion source. The positive reactant ions generated by the source were mass identified as being solvated protons of general formula (H2O)nH+ with (H2O)2H+ as the most abundant reactant ion. The negative reactant ions produced were mass identified primarily as CO3, NO3, NO2, O3 and O2 of various relative intensities. The predominant ion and relative ion ratios varied depending upon source construction and supporting gas flow rates. A few compounds including drugs, explosives and amines were selected to evaluate the new ionization source. The source was operated continuously for 3 months and although surface deterioration was observed visually, the source continued to produce ions at a rate similar that of the initial conditions.  相似文献   

15.
In the time period from June 2005 to May 2006 in 42 sampling campaigns 84 filter samples of airborne particulate matter, coarse (PM10–2.5) and fine (PM2.5), were collected using a Gent stacked filter unit in the coastal industrial area of Aspropyrgos in Attica, Greece. The average PM10 (PM10–2.5 + PM2.5) concentration was found to be 66 μg · m−3, exceeding more than 1.6 times the annual limit of 40 μg · m−3. The samples were analysed for Cl, NO3 , SO4 2−, Ca2+, Mg2+, Na+, K+ and NH4 + using ion chromatography. The data were compared with results obtained with other spectrometric methods, such as inductively coupled plasma-atomic emission spectrometry, atomic absorption spectrometry, energy dispersive X-ray fluorescence and reflectometry. The determined average ionic content comprised about 44% of the PM10 mass. The ionic composition, as well as the possible matrix compounds in both fractions were evaluated by dividing the sampling period into summer and winter season. In the PM10–2.5/PM2.5 fraction in summer time the concentrations of Ca2+, Mg2+ and NO3 were enriched in the coarse fraction. In winter time all species were enriched in the coarse fraction, especially Ca2+, Cl and NO3 . NH4 + was constantly higher in the fine fraction in summer as well as in winter time. Factor analysis was applied to obtain correlations between cations and anions leading to matrix compounds in both fractions. From the evaluation of the results obtained, some of the local air pollution sources could be identified. Correspondence: Klaus-Michael Ochsenkühn, Laboratory for Trace Element Studies, Institute of Physical Chemistry, NCSR “Demokritos”, Aghia Paraskevi 15310, Athens, Greece  相似文献   

16.
Three new calixarene Tl+ ionophores have been utilized in Tl+ ion-selective electrodes (ISEs) yielding Nernstian response in the concentration range of 10−2–10−6 M TlNO3 with a non-optimized filling solution in a conventional liquid contact ISE configuration. The complex formation constants (log βIL) for two of the calixarene derivatives with thallium(I) (i.e. 6.44 and 5.85) were measured using the sandwich membrane technique, with the other ionophore immeasurable due to eventual precipitation of the ionophore during these long-term experiments. Furthermore, the unbiased selectivity coefficients for these ionophores displayed excellent selectivity against Zn2+, Ca2+, Ba2+, Cu2+, Cd2+ and Al3+ with moderate selectivity against Pb2+, Li+, Na+, H+, K+, NH4+ and Cs+, noting that silver was the only significant interferent with these calixarene-based ionophores. When optimizing the filling solution in a liquid contact ISE, it was possible to achieve a lower limit of detection of approximately 8 nM according to the IUPAC definition. Last, the new ionophores were also evaluated in four solid-contact (SC) designs leading to Nernstian response, with the best response noted with a SC electrode utilizing a gold substrate, a poly(3-octylthiophene) (POT) ion-to-electron transducer and a poly(methyl methacrylate)–poly(decyl methacrylate) (PMMA–PDMA) co-polymer membrane. This electrode exhibited a slope of 58.4 mV decade−1 and a lower detection limit of 30.2 nM. Due to the presence of an undesirable water layer and/or leaching of redox mediator from the graphite redox buffered SC, a coated wire electrode on gold and graphite redox buffered SC yielded grossly inferior detection limits against the polypyrrole/PVC SC and POT/PMMA–PDMA SC ISEs that did not display signs of a water layer or leaching of SC ingredients into the membrane.  相似文献   

17.
A new microflow injection chemiluminescence (μFI-CL) system was described for the determination of cisplatin in human serum. By using the microchip with double spiral channel configuration, the sensitivity was greatly enhanced due to more efficient mixing of the analyte and reagent solutions. Experimental results revealed that common ions in human serum, such as Mn2+, Co2+, Fe3+, Cu2+, Zn2+, Ni2+, Na+, K+, Ca2+, Cl, NO3, Ac, CO32−, PO43−, SO42− did not cause interference with the detection of Pt(II) by using 1,10-phenanthroline as the masking agent. Under the optimized conditions, a linear calibration curve (R2 = 0.998) over the range 2.0 × 10−8 to 2.0 × 10−6 mol L−1 was obtained with the detection limit of 1.24 × 10−9 mol L−1. The relative standard deviation was found to be 3.46% (n = 12) for 2.0 × 10−7 mol L−1. The sample consumption was only 2 μL with the sample throughput of 72 h−1. It had been used for trace platinum determination in cisplatin injection and human serum samples after the dosage of cisplatin. The recovery varied from 97.6 to 103.9%. The results proved that the proposed μFI-CL system had the advantages of high sensitivity and precision, low sample and reagents consumption, and high analytical throughput.  相似文献   

18.
Dimethyl-4,4-dimethoxy-5,6,5′,6′-dimethylene dioxy biphenyl-2,2-dicarboxylate (DDB) liver drug is used as a novel ionophore in plasticized poly (vinyl chloride) (PVC) matrix membrane sensors for barium ions. Optimum performance characteristics are displayed by membrane sensor incorporating DDB ionophore, potassium tetrakis(4-chlorophenyl)borate as lipophilic salt, and o-nitrophenyloctyl ether as plasticizer. The sensor exhibits a linear response over the concentration range 10−1-10−5 mol l−1 BaCl2 with a Nernstian slope of 30 mV per decade and high selectivity towards Ba2+ with respect to Li+, Na+, K+, Rb+, NH4+, Mg2+, Ca2+, Sr2+, Mn2+, Co2+, Ni2+, Cd2+, Al3+, La3+, and Ce3+ ions. The sensor response is stable over a wide pH range (4-9) and the lifetime is about 2 months. The proposed sensor is successfully applied to the determination of Ba2+contents of some rocks.  相似文献   

19.
Spatial structures of complexes [DyAc]2+, [DyBz]2+, [DyAc2]+ and [DyBz2]+ in aqueous solutions (Ac and Bz, acetate and benzoate anions, respectively) are studied using the paramagnetic double refraction method. The polyhedra of [DyAc(H2O)6]2+ and [DyBz(H2O)6]2+ are dodecahedra with ligands coordinated at one of the edges. In the complexes [DyAc2(H2O)4]+ and [DyBz2(H2O)4]+ the ligands are coordinated at the edges of a square antiprism at an angle of 50 (55)° to the local symmetry axis of higher symmetry.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 6, pp. 1038–1040, June, 1993.  相似文献   

20.
Somer G  Sezer S  Doğan M  Kalaycı S  Sendil O 《Talanta》2011,85(3):1461-1465
A new borate ion selective electrode using solid salts of Ag3BO3, Ag2S and Cu2S has been developed. Detailed information is provided concerning the composition, working pH and conditioning of the electrode. An analytically useful potential change occurred from 1 × 10−6 to 1 × 10−1 M borate ion. The slope of the linear portion was 31 ± 2 mV/10-fold changes in borate concentration. The measurements were made at constant ionic strength (0.1 M NaNO3) and at room temperature. The effect of Cl, Br, NO3, SO=4, H2PO4 anions and K+, Na+, Cu2+, Ag+, Ca2+ cations on borate response is evaluated and it was found that only Ag+ had a small interference effect. The lifetime of the electrode was more than two years, when used at least 4-5 times a day, and the response time was about 20-30 s. Borate content in waste water of borax factory, tap water of a town situated near to the borax factory and city tap water far from these mines were also determined. The validation was made with differential pulse polarography for the same water sample, and high consistency was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号