首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Thermal response tests (TRTs) are crucial for the estimation of the ground thermal properties and thermal performance of the borehole heat exchanger (BHE) of the ground-coupled heat pump (GCHP) system. In this article, a TRT apparatus was designed and built to measure the temperature response of inlet and outlet sections of BHE in the test borehole, the apparatus can effectively operate under both constant heating flux modes and heat injection and extraction modes with a constant inlet temperature. A TRT for a project of GCHP located in the Jiangsu province of China was carried out by the experimental apparatus. Based on the experimental data, the heat transfer performances of BHE under heating and cooling modes were evaluated, and the ground thermal properties, which include the ground thermal conductivity, ground volumetric specific heat, borehole thermal resistance and effective soil thermal resistance, were determined by the line source model. The results indicate that the experimental device and analysis model proposed in this article can be effectively applied to estimate the ground thermal properties and thermal performance of BHE. During the process of thermal response of ground, the fluid temperatures vary acutely at the start-stage of 8 h, and then tend to be a steady state after 40 h. The test data during the start-stage should be discarded for improving the estimation accuracy of ground thermal properties. At the same time, the effective soil thermal resistance increases continuously with time and a steady-state value would be reached after the start-time, and this steady-state thermal resistance can be used to evaluate the required length of BHE. In addition, the heat transfer rate of the BHE under different operating conditions can be used for the further evaluation on long-term operation performance of GCHPs.  相似文献   

2.
A simulation was performed, which concerned the feasibility of seasonal underground thermal energy storage (UTES) in Tianjin, China. The investigated system consisted of 8 boreholes. In summer, residual solar thermal energy was emitted into the soil surrounding the borehole heat exchangers through which the stored energy was extracted in winter with a ground coupled heat pump (GCHP) to provide a proper heating temperature. A simulation study was performed to study the influence of system operation modes on thermal recovery based on the experimental data of a GCHP system, local meteorological conditions and soil properties in Tianjin. The results indicate a thermal recovery ratio of less than 67% and different temperature distributions under three modes. Finally, an operation mode was suggested based on both lower loss and better thermal recovery in the UTES.  相似文献   

3.
When the ground coupled heat pump (GCHP) system is utilized for air conditioning in cooling load dominated buildings, the heat rejected into ground will accumulate around the ground heat exchangers (GHE) and results in system performance degradation. A novel hybrid ground coupled heat pump (HGCHP) system with nocturnal cooling radiator (NCR) works as supplemental heat rejecter is proposed in this paper to resolve this problem. The practical analytical model of NCR and novel HGCHP system are established. The computer program based on established model is developed to simulate the system operation performance. The novel HGCHP system is designed and simulated for a sample building located in Hong Kong, and a simple life cycle cost comparisons are carried out between this system and conventional GCHP system. The results indicate that it is feasible to use NCR serves as supplemental heat rejecter of the novel HGCHP system for cooling load dominated buildings even those located in humid subtropical climate areas. This novel HGCHP system provides a new valuable choice for air conditioning in cooling load dominated buildings, and it is especially suitable for buildings with limited surface land areas.  相似文献   

4.
The objective of this study is to show the temperature distribution development in the borehole of the ground-coupled heat pump systems (GCHPs) with time. The time interval for the study is 48 h. The vertical GCHP system using R-22 as refrigerant has a three single U-tube ground heat exchanger (GHE) made of polyethylene pipe with a 40 mm outside diameter. The GHE was placed in a vertical borehole (VB) with 30 (VB1), 60 (VB2) and 90 (VB3) m depths and 150 mm diameters. The experimental results were obtained in cooling and heating seasons of 2006–2007. A two-dimensional finite element model (FEM) was developed to simulate temperature distribution development in the soil surrounding the GHEs of GCHPs operating in the cooling and the heating modes. The finite element modelling of the GCHP system was performed using the ANSYS code. The FEM incorporated pipes, the grout and the surrounding formation. From the cases studied, this approach appears to be the most promising for estimation the temperature distribution response of GHEs to thermal loading.  相似文献   

5.
This article experimentally investigates the thermal performances of a heat pipe with phase change material for electronic cooling. The adiabatic section of heat pipe is covered by a storage container with phase change material (PCM), which can store and release thermal energy depending upon the heating powers of evaporator and fan speeds of condenser. Experimental investigations are conducted to obtain the system temperature distributions from the charge, discharge and simultaneous charge/discharge performance tests. The parameters in this study include three kinds of PCMs, different filling PCM volumes, fan speeds, and heating powers in the PCM cooling module. The cooling module with tricosane as PCM can save 46% of the fan power consumption compared with the traditional heat pipe.  相似文献   

6.
R&D of the ground-coupled heat pump technology in China   总被引:1,自引:0,他引:1  
The ground-coupled heat pump (GCHP) systems have been identified as one of the best sustainable energy technologies for space heating and cooling in residential and commercial buildings. In this paper, research on and development of the GCHP technology in China are summarized. New models are presented for efficient thermal analysis of ground heat exchangers, of which one- and two-dimensional solid cylindrical source models and their analytical solutions are devised to deal with pile ground heat exchangers. Analytical solutions are also derived for vertical and inclined finite line source models as well as for a groundwater advection model. Explicit solutions of a quasi-three-dimensional model can be used to better evaluate the thermal resistance inside boreholes. Studies on hybrid GCHP systems and the thermal response test in China are also commented.  相似文献   

7.
The ground-coupled heat pump (GCHP) systems have been identified as one of the best sustainable energy technologies for space heating and cooling in residential and commercial buildings. In this paper, research on and development of the GCHP technology in China are summarized. New models are presented for efficient thermal analysis of ground heat exchangers, of which one- and two-dimensional solid cylindrical source models and their analytical solutions are devised to deal with pile ground heat exchangers. Analytical solutions are also derived for vertical and inclined finite line source models as well as for a groundwater advection model. Explicit solutions of a quasi-three-dimensional model can be used to better evaluate the thermal resistance inside boreholes. Studies on hybrid GCHP systems and the thermal response test in China are also commented.  相似文献   

8.
Dong Chen 《传热工程》2020,41(9-10):800-813
Abstract

A new method was developed and validated against numerical simulations for the calculation of ground heat transfer via floors with vertical edge insulations along the external side of walls. Using the new method, heating and cooling energy demand for two typical houses in the eight capital cities of Australian state and territory were evaluated with different vertical edge insulations and full horizontal floor insulations. It was found that for tropical regions such as Darwin, both vertical edge and full horizontal floor insulation have no or little effect on house heating and cooling energy demand. In cooling dominated climates such as Brisbane, full horizontal floor insulation may increase the total heating and cooling energy demand due to the decoupling between the relatively cool ground and the rooms above. For heating dominated climates such as Melbourne, Canberra and Hobart, ground heat loss can contribute up to around half of the total house heating and cooling energy demand. Full horizontal floor insulation can be very effective in these heating dominated climates. For heating and cooling balanced climates such as Adelaide, Perth and Sydney, vertical edge insulation along the external side of the walls is more effective than full floor insulation.  相似文献   

9.
The ground-coupled heat pump (GCHP) system is a type of renewable energy technology providing space heating and cooling as well as domestic hot water. However, experimental studies on GCHP systems are still insufficient. This paper first presents an energy-operational optimisation device for a GCHP system involving insertion of a buffer tank between the heat pump unit and fan coil units and consumer supply using quantitative adjustment with a variable speed circulating pump. Then, the experimental measurements are used to test the performance of the GCHP system in different operating modes. The main performance parameters (energy efficiency and CO2 emissions) are obtained for one month of operation using both classical and optimised adjustment of the GCHP system, and a comparative analysis of these performances is performed. In addition, using TRNSYS (Transient Systems Simulation) software, two simulation models of thermal energy consumption in heating, cooling and domestic hot-water operation are developed. Finally, the simulations obtained using TRNSYS are analysed and compared to experimental data, resulting in good agreement and thus the simulation models are validated.  相似文献   

10.
Design of a seasonal thermal energy storage in the ground   总被引:1,自引:0,他引:1  
M. Reuss  M. Beck  J. P. Müller 《Solar Energy》1997,59(4-6):247-257
Longterm storage of high quantities of thermal energy is one of the key problems for a widespread and successful implementation of solar district heating and for more efficient use of conventional energy sources. Seasonal storage in the ground in the temperature range of up to 90°C seems to be favourable from a technical and economical point of view. Preferably duct systems with vertical heat exchangers can be built in areas without ground water or low flow velocity compared with the geometry of the store and the storage period.

The thermal performance of such systems is influenced by the heat and moisture movement in the area surrounding the heat exchangers. Thermal conductivity and heat capacity are strongly dependent on the water content. This combined heat and moisture transport was simulated on the computer for temperatures up to 90°C. This model calculates the effective heat transfer coefficient and the heat capacity of the soil depending on water content, mineral composition, dry bulk density and shape of soil components. The computer simulation was validated by a number of laboratory and field experiments.

Based on this theoretical work a pilot plant was designed for seasonal storage of industrial waste heat. A heat and power cogeneration unit (174 kWth) delivers waste heat during summer to the ground storage of about 15 000 m3 with 140 vertical heat exchangers of 30 m depth. About 418 MWh/a will be charged into the ground at a temperature level of 80°C, about 266 MWh/a should be extracted at temperatures between 40°C and 70°C and delivered directly to the space heating system. With this design an economic calculation gave energy prices of 39 US$/MWh which is of the same order as conventional energy prices.  相似文献   


11.
Vertical-borehole ground-coupled heat pumps: A review of models and systems   总被引:3,自引:0,他引:3  
H. Yang  P. Cui  Z. Fang   《Applied Energy》2010,87(1):16-27
A large number of ground-coupled heat pump (GCHP) systems have been used in residential and commercial buildings throughout the world due to the attractive advantages of high efficiency and environmental friendliness. This paper gives a detailed literature review of the research and developments of the vertical-borehole GCHP technology for applications in air-conditioning. A general introduction on the ground source heat pump system and its development is briefly presented first. Then, the most typical simulation models of the vertical ground heat exchangers currently available are summarized in detail including the heat transfer processes outside and inside the boreholes. The various design/simulation programs for vertical GCHP systems primarily based on the typical simulation models are also reviewed in this paper. Finally, the various hybrid GCHP systems for cooling or heating-dominated buildings are well described. It is found that the GCHP technology can be used both in cold and hot weather areas and the energy saving potential is significant.  相似文献   

12.
For the purpose of decreasing the peak electricity, balancing the on and off-peak electric load and utilizing the renewable geothermal energy, a new integrated system with cooling storage in soil and a ground-coupled heat pump is presented. In the integrated system, the moist soil acts as the material for cooling storage, and pipes serve as the cooling storage devices and geothermal heat exchangers simultaneously. In the cooling season, the cooling energy is stored in soil during the off-peak period and is extracted for space cooling during the on-peak period. While in other seasons, the system works as a ground-coupled heat pump for heating or cooling. A mathematical model which describes the charging and discharging processes of the integrated system has been developed and validated, and a computer code has been implemented to simulate the operational performance of cooling charging and discharging in soil. A parametric study indicates that the charging inlet temperature, tube diameter, moisture content of soil and pipe distance are important factors in determining the cyclic performance of the integrated system.  相似文献   

13.
如何保证地源热泵式沼气池加温系统长期稳定运行   总被引:1,自引:1,他引:0  
针对地源热泵式沼气池加温系统中出现的冬夏季取排热不平衡从而影响其长期稳定运行的问题,本文在采取控制运行方式、增加辅助热源和蓄热系统解决方法的分析基础上,从充分利用可再生能源和地源热泵设备的角度出发,提出热泵供热和制冷互补模式与太阳能-地源热泵多功能互补模式,并对其可行性进行分析。  相似文献   

14.
A simulation was performed, which concerned the feasibility of seasonal underground thermal energy storage (UTES) in Tianjin, China. The investigated system consisted of 8 boreholes. In summer, residual solar thermal energy was emitted into the soil surrounding the borehole heat exchangers through which the stored energy was extracted in winter with a ground coupled heat pump (GCHP) to provide a proper heating temperature. A simulation study was performed to study the influence of system operation modes on thermal recovery based on the experimental data of a GCHP system, local meteorological conditions and soil properties in Tianjin. The results indicate a thermal recovery ratio of less than 67% and different temperature distributions under three modes. Finally, an operation mode was suggested based on both lower loss and better thermal recovery in the UTES. __________ Translated from Journal of North China Electric Power University, 2007, 34(2): 74–77 [译自: 华北电力大学学报]  相似文献   

15.
In this paper, an experimental performance evaluation of a direct expansion ground‐coupled heat pump (DX‐GCHP) system in heating mode is presented. The DX‐GCHP uses R134a as the refrigerant, and consists of three single U‐tube copper ground heat exchangers (GHEs) placed in three 30 m vertical boreholes. During the on–off operations from December 25, 2007, to February 6, 2008, the heat pump supplied hot water to fan‐coil at around 50.4°C, and its heating capacity was about 6.43 kW. The energy‐based heating coefficient of performance (COP) values of the heat pump and the whole system were found to be on average 3.55 and 3.28 at an evaporating temperature of 3.14°C and a condensing temperature of 53.4°C, respectively. The second law efficiency on the DX‐GCHP unit basis was around 0.36. The exergetic COP values of the heat pump and the whole system were obtained to be 0.599 and 0.553 (the reference state temperature was set equal to the average outdoor temperature of ?1.66°C during the tests), respectively. The authors also discussed some practical points such as the heat extraction rate from the ground, refrigerant charge and two possible new configurations to simultaneously deal with maldistribution and instability of parallel GHE evaporators. This paper may reveal insights that will aid more efficient design and improvement for potential investigators, designers and operators of such DX‐GCHP systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
基于寒冷地区地源热泵运行的实验数据,建立了串联式太阳能辅助地源热泵供暖系统优化数学模型,并用约束变尺度法获得最优解。根据优化方法,以综合考虑系统运行性能和经济性为原则,对一实际工程进行了最优化研究。结果表明,采用优化设计后,系统总投资与采用传统设计时大致相当,但机组供暖运行性能有明显提高,COP提高了约16.7%,总功耗下降了17.2%,年均总成本降低了11.8%。  相似文献   

17.
The ground-coupled heat pump (GCHP) system is becoming attractive for air-conditioning in some moderate-weather regions due to its high energy efficiency and reliable operation capability. However, when the technology is used in buildings where there is only cooling load in hot-weather areas like Hong Kong, the heat rejected into the ground by the GCHP systems will accumulate around the ground heat exchangers (GHE). This heat accumulation will result in degradation of system performance and increment of system operating costs. This problem can be resolved by using the hybrid ground-coupled heat pump (HGCHP) system, which uses supplemental heat rejecters to reject the accumulated heat. This paper presents a practical hourly simulation model of the HGCHP system by modeling the heat transfer process of the system’s main components. The computer program based on this hourly simulation model can be used to calculate the hour-by-hour operation data of the HGCHP system. As a case study, both a HGCHP system and a traditional GCHP system are designed for a hypothetic private residential building located in Hong Kong, and the economic comparisons are conducted between these two types of systems. The simulation results show that the HGCHP system can effectively solve the heat accumulation problem and reduce both the initial costs and operating costs of the air-conditioning system in the building.  相似文献   

18.
土壤蓄冷与耦合热泵集成系统中土壤蓄冷的模拟研究   总被引:5,自引:2,他引:5  
结合土壤耦合热泵技术及冻土蓄冷技术的优点,提出一种全新的热泵空调系统形式一土壤蓄冷与土壤耦合热泵集成系统。该系统将土壤耦合热泵系统(GCHP)的地下埋管换热器与蓄冷装置合二为一,在电力低谷期将冷量贮存到土壤中,以满足高峰电力期空调负荷的需要。在能量平衡的基础上建立了土壤蓄冷释冷过程的数学模型,并采用固相增量法模型对其进行了模拟计算,分析其应用的技术可行性,为土壤蓄冷与土壤耦合热泵集成系统的应用提供理论支持。  相似文献   

19.
Storage of heat is seen as a major issue for the development of solar energy for house heating and cooling under all climates. Most of the storage systems available on the market use water as the storage medium. The idea studied here was to add a phase change material (PCM) module at the top of a hot-water storage tank with stratification. An experimental solar pilot plant was constructed to test the PCM behaviour in real conditions. The PCM module geometry adopted was to use several cylinders. A granular PCM–graphite compound was chosen as the PCM for the experiments presented here.  相似文献   

20.
We present a three-dimensional numerical model for seasonal heat storage in the ground using vertical heat exchanger pipes. The model also accounts for convective heat flows in the ground. The storage is employed in a district solar heating system with a heat pump. The effects of storage volume, storage medium, collector area, and collector type on system performances are studied for the Helsinki (60°N) climate. Economic optimization of the storage and collector installation is also briefly discussed. For a 500-house community, a collector area of 35 m2 per house and a rock storage volume of 550 m3 per house would provide a solar fraction of 70%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23