首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multi-walled carbon nanotubes (MWNTs) supported platinum nanoparticles with narrow size distribution were prepared by an organic colloidal process with sodium citrate as the coordination reagent and stabilizer, and ethylene glycol as the reduction reagent. A nonenzymatic glucose sensor with high sensitivity based on the Pt/MWNTs electrode was demonstrated. Transmission electron microscopy (TEM) and X-ray diffraction (XRD) were employed to investigate the size distributions and the crystal structure of Pt nanoparticles on the MWNTs. The TEM images show that the Pt nanoparticles with about 2–4 nm in diameter are well dispersed on the MWNTs. The Pt/MWNTs shows high electrocatalytic activity towards the oxidation of glucose in 0.1 M NaOH solution. At +0.5 V, the Pt/MWNTs nanocomposite electrode exhibits linearity in the range of 1 mM to 23 mM (R > 0.998) glucose with a response time of 11.6 s. The detection limit is 50 μM (S/N = 3). It was demonstrated that the Pt/MWNTs electrode with high electrocatalytic activity to glucose oxidation could find application in nonenzymatic detection of glucose.  相似文献   

2.
A nonenzymatic amperometric sensor for sensitive and selective detection of glucose has been constructed by using highly dispersed Pt nanoparticles supported onto mesoporous carbons (MCs). The Pt nanoparticles/mesoporous carbons (Pt/MCs) composites modified electrode displayed high electrocatalytic activity towards the oxidation of glucose. At an applied potential of 0.1 V, the Pt/MCs electrode has a linear dependence (R=0.996) in the glucose concentration up to 7.5 mM with a sensitivity of 8.52 mA M?1 cm?2. The Pt/MCs electrode has also shown highly resistant toward poisoning by chloride ions and without interference from the oxidation of common interfering species.  相似文献   

3.
In this communication, an amperometric glucose biosensor based on MnO2/MWNTs electrode was reported. MnO2 was homogeneously coated on vertically aligned MWNTs by electrodeposition. The MnO2/MWNTs electrode displayed high electrocatalytic activity towards the oxidation of glucose in alkaline solution, showing about 0.30 V negative shift in peak potential with oxidation starting at ca. −0.20 V (vs. 3 M KCl–Ag/AgCl) as compared with bare MWNTs electrode. At an applied potential of +0.30 V, the MnO2/MWNTs electrode gives a linear dependence (R = 0.995) in the glucose concentration up to 28 mM with a sensitivity of 33.19 μA mM−1. Meanwhile, the MnO2/MWNTs electrode is also highly resistant toward poisoning by chloride ions. In addition, interference from the oxidation of common interfering species such as ascorbic acid, dopamine, and uric acid is effectively avoided. The MnO2/MWNTs electrode allows highly sensitive, low-potential, stable, and fast amperometric sensing of glucose, which is promising for the development of nonenzymatic glucose sensor.  相似文献   

4.
Electrochemical behavior of dopamine at the RuO2‐modified vertically aligned carbon nanotubes electrode was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The RuO2‐modified carbon nanotube electrode showed higher electrocatalytic activity towards the oxidation of dopamine than the MWNTs electrode in 0.10 M phosphate buffer solution. At an applied potential of +0.4 V, the RuO2/MWNTs electrode exhibited a wide detection range up to 3.6×10?3 M with detection limit of 6.0×10?8 M (signal/noise=3) for dopamine determination. Meanwhile, the optimized sensor for dopamine displayed a sensitivity of 83.8 μA mM?1 and response time of 5 s with addition of 0.20 mM dopamine. In addition, DPV experiment revealed that interfering species such as ascorbic acid and uric acid could be effectively avoided. The RuO2/MWNTs electrode presents stable, highly sensitive, favorable selectivity and fast amperometric response of dopamine.  相似文献   

5.
A highly sensitive and selective glucose biosensor has been constructed by using highly dispersed NiO nanoparticles supported on well-aligned MWCNTs (NiO/MWCNTs) as sensing interface. The NiO/MWCNTs nanocomposite was synthesized by magnetron sputtering deposition of NiO nanoparticles on vertically aligned carbon nanotubes. The nanocomposite electrode showed high electrochemical activity towards the oxidation of glucose in 0.20 M NaOH solution. At an applied potential of +0.50 V, it gives a fast response time (< 5 s) and a linear dependence (R?=?0.997) on the glucose concentration up to 7.0 mM with an extraordinarily high sensitivity of 1.77 mA mM-1 cm-2 and a detection limit of 2 μM. The interference by the oxidation of common interfering species such as ascorbic acid, dopamine, uric acid, lactose, and fructose is effectively avoided. The electrode was used to analyze glucose concentration in human serum samples. It allows highly sensitive, stable, and fast amperometric sensing of glucose, which is promising for the development of nonenzymatic glucose sensors.  相似文献   

6.
Nanoparticles containing platinum and gold supported on MWNTs (Pt@Au/MWNTs) were successfully prepared by successive reduction. A novel sensor was fabricated with Pt@Au/MWNTs nanocomposite modified glassy carbon electrode coating with nafion. Compared with the previous reports, the electrode exhibited greatly improved performance towards the oxidation and determination of dopamine in the presence of ascorbic acid. A higher sensitivity of 1.16 mA cm?2 mM?1 with a wider linear concentration range of dopamine up to 120 μM and a low detection limit of 8.0×10?8 M were obtained in neutral solution. Moreover, the modified electrode presented high stability and reproducibility. The interference of ascorbic acid can be eliminated effectively. The present work provides a simple and practical approach to selective detection of dopamine in the presence of ascorbic acid.  相似文献   

7.
Titanium‐supported nanoscale flaky nickel electrode (nanoNi/Ti) was prepared by a hydrothermal process using hydrazine hydrate as a reduction agent. Its electrocatalytic activity as an electrocatalyst for the electrooxidation of glucose was evaluated in alkaline solutions using cyclic voltammetry (CV), chronoamperometric responses (CA) and electrochemical impedance spectra (EIS). The nanoNi/Ti electrode exhibits significantly high current density of glucose oxidation. A high catalytic rate constant of 1.67×106 cm3 mol?1 s?1 was calculated from amperometric responses on the nanoNi/Ti electrode. Low charge transfer resistances on the nanoNi/Ti in 0.5 M NaOH containing various concentrations of glucose were obtained according to the analysis for EIS. Furthermore, amperometric data show a linear dependence of the current density for glucose oxidation upon glucose concentration in the range of 0.05–0.6 mM with a sensitivity of 7.32 mA cm?2 mM?1. A detection limit of 0.0012 mM (1.2 μM) M glucose was found. Results show that the prepared nanoNi/Ti electrode presents high electrocatalytic activity for glucose oxidation.  相似文献   

8.
建立了多壁碳纳米管(MWNTs)负载铂二二氧化钌纳米颗粒的液相化学还原法.以Nafion为固定剂,将Pt-RuO2/MWNTs复合材料修饰于玻碳电极的表面,制备了一种无酶型葡萄糖传感器.实验表明:复合材料修饰的电极对葡萄糖响应电流明显,并且受抗坏血酸(AA)、多巴胺(DA)和尿酸(UA)的干扰小.本实验采用安培法测定葡萄糖,线性范围为2 0×10 3~1.0×10-2 mol/L(R~0.9965);灵敏度为119.26 μA cm-2(mmol/L)-1;检出限为1.25×10 -5 mol/L(信噪比为3);响应时间为4.8 s.PtRuO2/MWNTs修饰电极可作为性能良好的无酶型葡萄糖传感器.  相似文献   

9.
Sangeun Cho  Chan Kang 《Electroanalysis》2007,19(22):2315-2320
A nonenzymatic glucose sensor with good selectivity for the ascorbic acid oxidation is presented. After the gold polycrystalline electrode was subjected to amalgamation treatment, two advantageous effects were observed. One is the enhancement of the surface roughness and the other is an increase in the catalytic current in the glucose oxidation. Besides the known first effect, the latter provided another advantageous effect in a fabrication of nonenzymatic glucose sensor. Using a gold electrode subjected to amalgamation treatment for 60 s, two calibration curves for glucose oxidation at two different potentials of ?0.1 V and 0.25 V were obtained and compared. At the potential of ?0.1 V, at which no ascorbic acid was oxidized and no interference effect was observed, a current sensitivity of 16 μA cm?2 mM?1 from zero to 10 mM glucose concentration range was obtained. At the other potential of 0.25 V, at which ascorbic acid was easily oxidized, a satisfactory calibration curve with negligible ascorbic acid interference was also obtained together with a more enhanced current sensitivity of 32 μA cm?2 mM?1.  相似文献   

10.
A glassy carbon electrode (GCE) was modified with nickel(II) hydroxide nanoparticles and a film of molybdenum sulfide. The nanocomposite was prepared by two-step electrodeposition. Scanning electron microscopy reveals that the nanoparticles are uniformly deposited on the film. Cyclic voltammetry and chronoamperometry indicate that this modified GCE displays a remarkable electrocatalytic activity towards nonenzymatic oxidation of glucose. Response is linear in the 10–1,300 μM concentration range (R 2 ?=?0.9987), the detection limit is very low (5.8 μM), response is rapid (< 2 s), and selectivity over ascorbic acid, dopamine, uric acid, fructose and galactose is very good.
Figure
An efficient nonenzymatic glucose sensor based on Ni(OH)2/MoSx nanocomposite modified glassy carbon electrode has been fabricated via a two-step electrodeposition approach. The resulting nonenzymatic sensor exhibits excellent properties toward glucose detection, such as low detection limit, fast response and noticeable selectivity.  相似文献   

11.
Commercially available copper foam (CF) was used as a 3D porous electrochemical sensing platform for nonenzymatic glucose detection. CF shows high electrocatalytic activity towards glucose oxidation and can be used directly for glucose electrochemical sensing without any pretreatment. The sensor exhibits high performance towards glucose in 0.1 M NaOH solution with the linear range from 1 μM to 0.5 mM, the sensitivity of 5.85 mA mM?1 cm?2 and the detection limit of 0.5 μM (S/N=3) simultaneously. Furthermore, the sensor shows a high selectivity for glucose against the common interferences and good reliability for glucose detection in human serum samples.  相似文献   

12.
《Analytical letters》2012,45(5):913-926
Abstract

A new nanocomposite was developed by combination of prussian blue (PB) nanoparticles and multiwalled carbon nanotubes (MWNTs) in the matrix of biopolymer chitosan (CHIT). The PB and MWNTs had a synergistic electrocatalytic effect toward the reduction of hydrogen peroxide. The CHIT/MWNTs/PB nanocomposite‐modified glassy carbon (GC) electrode could amplify the reduction current of hydrogen peroxide by ~35 times compared with that of CHIT/MWNTs/GC electrode and reduce the response time from ~60 s for CHIT/PB/GC to 3 s. Besides, the CHIT/MWNTs/PB nanocomposite‐modified GC electrode could reduce hydrogen peroxide at a much lower applied potential and inhibit the responses of interferents such as ascorbic acid (AA) uric acid (UA) and acetaminophen (AC). With glucose oxidase (GOx) as an enzyme model, a new glucose biosensor was fabricated. The biosensor exhibited excellent sensitivity (the detection limit is down to 2.5 µM), fast response time (less than 5 s), wide linear range (from 4 µM to 2 mM), and good selection.  相似文献   

13.
《Analytical letters》2012,45(8):1610-1621
Abstract

Cobalt hexacyanoferrate (CoHCF) film was formed on multiwalled carbon nanotubes (MWNTs) modified gold electrode by electrodeposition from 0.5 M KCl solution containing CoCl2 and K3Fe(CN)6. The electrochemical behavior and the electrocatalytic property of the modified electrode were investigated. Compared with CoHCF/gold electrode, the CoHCF/MWNTs/gold electrode exhibits greatly improved stability and enhanced electrocatalytic activity toward the oxidation of thiosulfate. A linear range from 5.0×10?5 to 6.5×10?3 M (r=0.9990) for thiosulfate detection at the CoHCF/MWNTs/gold electrode was obtained, with a detection limit of 2.0×10?5 M (S/N=3).  相似文献   

14.
In this study, an available and inexpensive graphite substrate, was easily modified with Ni/Cr nanoparticles via electrodeposition technique in a very short time (3 min) and used as an electrocatalyst for glucose oxidation in alkaline solution. Graphite electrode modified with Ni/Cr nanoparticles demonstrated an outstanding electrocatalytic performance to glucose oxidation in comparison to examined Ni‐based electrodes or even different materials in other reports. It is noteworthy to mention that adding a little Cr led to a synergistic effect with Ni; accordingly, the presence of Cr not only resulted in a greater adsorption of glucose molecules by chromium oxide but also boosted conductivity of the nickel oxide because of the enhancement of Ni(III) amount. The electrochemical studies were performed by cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The morphology and structure of catalyst layer was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X‐ray diffraction (XRD) and energy dispersive x‐ray spectroscopy (EDS). The linear range of the electrode by cyclic voltammetry was between 2–31 mM with a high sensitivity of 2094 μA cm?2 mM?1. The repeatability and reproducibility of the proposed electrode was examined in glucose solution which were 0.3 % and 4.7 %, respectively. According to the low cost, ease and fast preparation, good repeatability and high sensitivity, this electrode can be a good candidate for nonenzymatic glucose oxidation.  相似文献   

15.
A non-enzymatic sensor was developed for the determination of glucose in alkaline medium by anodisation of copper in sodium potassium tartrate solution. The morphology of the modified copper electrode was studied by scanning electron microscopy, and its electrochemical behavior by cyclic voltammetry and electrochemical impedance spectroscopy. The electrode enables direct electrocatalytic oxidation of glucose on a CuO/Cu electrode at 0.7 V in 0.1 M sodium hydroxide. At this potential, the sensor is highly selective to glucose even in the presence of ascorbic acid, uric acid, or dopamine which are common interfering species. The sensor displays a sensitivity of 761.9 μA mM?1 cm?2, a linear detection range from 2 μM to 20 mM, a response time of <1 s, and a detection limit of 1 μM (S/N = 3). It was tested for determination of glucose level in blood serum.  相似文献   

16.
《Analytical letters》2012,45(5):775-789
Abstract

In this work, we report the development of a highly sensitive and stable uric acid sensor based on the synergic action of multiwalled carbon nanotubes (MWNTs) and ZnO nanoparticles. MWNTs were first cast on pyrolytic graphite (PG) wafers. ZnO nanoparticles were then decorated onto the negatively charged MWNTs via the Vapor Liquid Solid (VLS) growth. Uricase was immobilized on the ZnO nanoparticles surface because of their large differences in the isoelectric point (IEP). Last, a cationic polydiallyldimethylammonium chloride (PDDA) layer was coated onto the uricase-contained ZnO nanoparticle layer and resulted in the PDDA/uricase/ZnO/MWNTs multilayer structure. The unique multilayer structure provides a favorable microenvironment to keep the bioactivity of uricase, which led to rapid amperometric response toward uric acid. Amperometric detection of uric acid was carried out at 320 mV (vs. SCE) in 0.05 mol/L (M) phosphate buffer solution (pH 6.8). For the sensor, a wide linear response range of 5.0 µM to 1 mM with a linear sensitivity of 393 mA cm?2M?1, a detection limit of 2.0 µM (3σ), and a long-term stability of 160 days can be obtained by using differential pulse voltammetry (DPV). Testing results in human urine obtained from the sensors were also compared with the data obtained by spectrometry. For five samples with different concentrations of urine, the relative deviations between them were smaller than 3.8%. The recovery was between 96.5 and 104.0%.  相似文献   

17.
《Electroanalysis》2005,17(9):749-754
A sensitive electrochemical method for the determination of simvastatin (SV) was established, based on the enhanced oxidation of SV at a multi‐walled carbon nanotubes‐dihexadecyl hydrogen phosphate composite modified glassy carbon electrode (MWNTs‐DHP/GCE). The voltammetric studies showed that MWNTs instead of DHP or GCE could effectively catalyze the oxidation of SV. The dependence of oxidation current on SV concentration was explored under optimal conditions, which exhibited a good linear relationship in the range of 1.0×10?7–7.5×10?6 M. The detection limit of SV was also examined and a low value of 5.0×10?8 M was obtained for 5 min accumulation (σ=3). This electrode was applied to the detection of SV in drug forms and the results were in accordance with those obtained by UV spectroscopy.  相似文献   

18.
A nonenzymatic glucose sensor was successfully established by electrochemically decorating cobalt oxides (CoOx) on a nanoporous gold electrode (NPG) using cobalt hexacyanoferrate (CoHCF) as a precursor. It exhibited high sensitivity and long‐term stability as well as satisfactory quantification of glucose concentration in human serum samples. The morphology and surface analysis of the resulting CoOx/NPG were carefully characterized. Two detection methods, cyclic voltammetry and amperometry, were employed to evaluate the performance of CoOx/NPG towards glucose sensing in alkaline solution. Using cyclic voltammetry, at ?0.5 V, the glucose partial oxidation peak current is linear to the glucose concentration up to 14 mM with a sensitivity of 283.7 µA mM?1 cm?2. A linear amperometric response at 0.55 V was obtained in the glucose concentration range from 2 µM to 2 mM with a sensitivity of 2025 µA mM?1 cm?2 and a response time <3 s.  相似文献   

19.
A novel nonenzymatic glucose sensor was developed based on well‐dispersed gold nanoparticles, which were in situ grown under direction of protein on a reduced graphene oxide modified electrode. This electrode exhibited high electrocatalytic activity towards glucose oxidation without use of any enzyme or mediator. In application for the amperometric detection of glucose, a wide linear range of 0.02–16.6 mM, low detection limit of 5 µM and good selectivity were obtained. The attractive analytical performances of the proposed glucose sensor, coupled with the facile preparation method, provide a promising electrochemical platform for the development of effective nonenzymatic sensors.  相似文献   

20.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号