 共查询到20条相似文献,搜索用时 328 毫秒
1.
The present paper discusses design and development of a force transducer of octagonal ring shape, which is a modified version of ring shaped force transducer. Nominal capacity of the force transducer designed and developed is 25 kN. This force transducer has been investigated for its utilization as force transfer standard for static force measurement and related applications. This force transducer is studied using dial gauge and strain gauges for its metrological characterization according to the calibration procedure based on standard ISO 376:2011/IS 4169:1988 (reaffirmed 2003) and is found to have good metrological results as compared to the existing ring shaped force transducers.  相似文献   

2.
《Measurement》2007,40(7-8):754-761
A comparison in the quantity of force was carried out among the Interamerican Metrology System (SIM) national laboratories in order to estimate the level of agreement for the realization of the quantity and the uncertainty associated to its measurement. This comparison was carried out up to 10 kN. The equipment used consisted on two force transducers (load cells); both with the same measuring range (10 kN). With the purpose of obtaining maximum accuracy on the transducers, the comparison range was selected from 4 kN up to 10 kN. This comparison (SIM comparison number SIM 7.7) has an overlap with the force steps used in the CIPM key comparison CCM.F-K1.a and CCM.F-K1.b. The results obtained, as well as the reference values selected for the comparison are included in this document. Two different methods were used to analyze the level of agreement and to state the conformity declaration.  相似文献   

3.
The Korea Research Institute of Standards and Science (KRISS) has developed a 20 N deadweight force standard machine. The machine consists of a weight stack, a loading frame, a taring system, a main body and a control system. The taring system has the role of compensating the initial force generated by the loading frame. With two motors, a displacement sensor, several limit switches, and a synthetic control system consisting of a programmable logic controller and an operating PC, the machine can be operated almost fully automatically. The machine can generate a compressive force in the range of 0.5–22 N with a relative expanded uncertainty of 1.0 × 10–4. The machine was compared with a 200 N deadweight force standard machine. In the comparison, the relative deviation was 5.8 × 10–5, less than the declared expanded uncertainty of the force standard machines, therefore confirming the machine’s accuracy.  相似文献   

4.
《Ultramicroscopy》2011,111(1):11-19
We present a new method to improve the accuracy of force application and hardness measurements in hard surfaces by using low-force (<50 μN) nanoindentation technique with a cube-corner diamond tip mounted on an atomic force microscopy (AFM) sapphire cantilever. A force calibration procedure based on the force-matching method, which explicitly includes the tip geometry and the tip-substrate deformation during calibration, is proposed. A computer algorithm to automate this calibration procedure is also made available. The proposed methodology is verified experimentally by conducting AFM nanoindentations on fused quartz, Si(1 0 0) and a 100-nm-thick film of gold deposited on Si(1 0 0). Comparison of experimental results with finite element simulations and literature data yields excellent agreement. In particular, hardness measurements using AFM nanoindentation in fused quartz show a systematic error less than 2% when applying the force-matching method, as opposed to 37% with the standard protocol. Furthermore, the residual impressions left in the different substrates are examined in detail using non-contact AFM imaging with the same diamond probe. The uncertainty of method to measure the projected area of contact at maximum force due to elastic recovery effects is also discussed.  相似文献   

5.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

6.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

7.
《Measurement》2007,40(7-8):741-745
In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of 0–1.6 μN by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), but the force vs. deflection is not as linear as the force vs. sensor output curve. The force constant of the cantilever was measured to 0.26 N/m with a standard deviation of 0.01 N/m. It shows that there is big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer’s specifications.  相似文献   

8.
A 50 N dead-weight type force standard machine (DWM) was developed by the National Metrology Institute of Japan to expand the lower end of calibration force from 10 N to 1 N. The weights of the DWM consisted of a loading frame and a linkage-weight stack. The loading frame applied a gravitational force of 1 N to a force transducer under calibration. The calibration and measurement capability of the 50 N DWM was verified to be 2 × 10−5 relative using a tuning-fork type force transducer in accordance with ISO 376. The equivalence between the 50 N and 500 N DWMs was confirmed by performing an intralaboratory comparison using the tuning-fork type force transducer. Moreover, the competence of the transducer for the evaluation of DWMs was demonstrated.  相似文献   

9.
The paper presents the accuracy and precision associated with realization of primary standard of sound using the reciprocity method. An experimental determination of the front cavity volume on Universal Measuring Machine has lead to reaffirmation of measurement uncertainty in pressure sensitivity determination to 0.04–0.15 dB in frequency range 31.5 Hz to 25 kHz. The reduced measurement uncertainty has also been validated from the results of the recent APMP Key comparison and also by comparison to the manufacturer’s value for LS2P microphones. The use of optical method for measuring the front cavity volume has refined the measurement methodology followed with adaptation of a self reliant, traceable and systematic measurement procedure in comparison to the earlier use of nominal values for sensitivity fitting exercise conducted on MP.EXE program. Consequently, the measurement uncertainty associated with the calibration of working standard microphones, multifunction acoustic calibrator and A-weighted sound pressure level measurements is also reduced.  相似文献   

10.
The presented 3D-ball plate is used for testing machine tools with a workspace of 500 mm × 500 mm × 320 mm. The artefact consists of a 2D-ball plate which is either located by a kinematic correct coupling on a base plate or on a spacer. The spacers are placed between the base plate and the ball plate and are also kinematic coupled to the other elements of the artefact. The kinematic couplings provide a high repeatability of the measurement setup. Because of the specific application the known calibration procedures for 2D-ball plates are not applicable.A calibration method for the pseudo-3D-artefact on a coordinate measuring machine (CMM) is presented, with the aim to minimise the influence of geometric CMM errors. Therefore a computer simulation is used to analyse the effects of these disturbing errors on the calibration of the ball plate and the spacers. Using a reversal method, the plate is measured at four different horizontal positions after rotating the ball plate around its vertical axis. A couple of the CMM errors, e.g., a squareness error C0Y between the X- and Y-axis of the CMM, can be eliminated by that method—others have to be determined with additional measurements, e.g., the positioning errors EXX or EYY of the X- and Y-axis, respectively. The paper also contains a measurement uncertainty estimation for the calibration by use of experiments, tolerances and Monte Carlo-simulations. The achieved uncertainty for ball positions in the working volume is less than 2.1 μm (coverage factor k = 2).  相似文献   

11.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

12.
Bilateral comparisons of the calibration of low nominal capacity torque measuring devices (TMDs) were conducted between NMIJ and PTB for the first time. A 10 N m deadweight torque standard machine (TSM) newly developed at NMIJ was compared with PTB’s two TSMs with nominal capacities of 1 N m and 1 kN m, in the range from 0.1 N m to 10 N m. The transfer measurement devices used had nominal capacities of 1 N m and 10 N m. The comparisons were made using two calibration procedures: one based on the CCM.T-K2 Key Comparison procedure and the other according to the daily calibration procedure adopted at each institute. As a result, the torque realized by the TSM at NMIJ was shown to be equivalent to that realized by the two TSMs at PTB. In addition, it was confirmed that the daily calibration procedures of both institutes yielded consistent results in the calibration of low nominal capacity TMDs.  相似文献   

13.
A motorized 5 m tape comparator was constructed in TUBITAK UME for calibration of tapes and rules up to 5 m length in one set-up and further lengths in multiple set-ups. The system is a practical development and provides a cost effective solution for calibration of tapes in which the highest grade’s accuracy requirement in OIML R35-1 e.g. is 600 μm for 5 m length and 1100 μm for 10 m length. It is mainly composed of 6 m rail system, mechanical parts, optical units and an integrated 6 m incremental linear encoder as a reference measurement axis for traceable measurements. The rails are kinematically located on a heavy marble construction and a motorized carriage, which employs a camera for probing of the scales on the tapes, is moved along the rails during the measurement. The image of the scale taken by the camera is viewed on the monitor screen together with the running software. The operator can perform the probing process by simply moving the carriage over the measured scales (tapes or rules) using a joystick. The carriage movement is measured by the incremental linear encoder previously calibrated by a laser interferometer and the software automatically takes the measurement results from the incremental linear encoder, applies correction values previously defined and determines the length of the tapes and rules as well as deviations from nominal lengths. The estimated expanded uncertainty of the steel tape measurement is U = 54 μm in one set-up (for 5 m length) and U = 77 μm in two set-ups (for 10 m length) at the confidence level of approximately 95%. Uncertainty budget for calibration of the device itself and for calibration of the test tapes are explained in detail. The results of extensive experimental work and analysis are provided by demonstrating application of science and technology of measurement and instrumentation. Investigations for long term stability of the system are given with the reported test results for the years of 2003-2011 and participated intercomparison results to validate the device scientifically are illustrated.  相似文献   

14.
To solve the problem of calibrating the radius of a ball indenter in a hardness tester, a laser confocal radius measurement and calibration method for the ball indenter is proposed without separating the ball from the body of the indenter. The laser confocal radius measurement and calibration method uses the maximum of the confocal axial intensity curve to precisely identify the cat’s eye and confocal position of the test ball indenter. The distance between these two positions is then measured to achieve high-precision radius measurement. The theoretical analyses and experimental results indicate that the radius measurement uncertainty of the ball indenter with a diameter of 1.5875 mm is within 0.12 μm.  相似文献   

15.
Transmission-line scattering parameters becomes unpractical to calculate as one includes more interfaces. Thus, to get an analytical expression, approximations are required. In this paper, an approximation methodology for the calculation of scattering parameters of transmission-line transducers is presented. The transducer cell is partitioned at each interface and the partial scattering equations are calculated, considering two interfaces at a time. Next, standard techniques are applied to solve the signal-flow diagrams to obtain the full scattering equations. Transmission-line transducers are used for the measurement of power absorption and reflection of different materials, such as: liquids, granular medium, and ground, in the RF/microwave range. Such measurements are used to extract materials properties. The proposed methodology has been applied to a coaxial transducer cell filled with different low-loss liquids. The results have been validated with computer simulations and experimental measurements. Measurements and simulations were carried out in the 300 kHz to 3 GHz frequency range.  相似文献   

16.
A displacement metrology and control system using an optical frequency comb generator and a dual Fabry-Perot cavity is developed with sub-nm accuracy. The optical frequency comb generator has expanded the displacement measurement range and the dual cavity system has suppressed the environmental fluctuation. We evaluated the absolute uncertainty of the developed displacement measurement system to be approximately 190 pm for the displacement of 14 μm and the accurate displacement control using a phase-locked loop was demonstrated with a resolution of approximately 24 pm.  相似文献   

17.
Measurement uncertainty is an important parameter to express measurement results including means and reliability. The uncertainty analysis of the biomedical measurement system needs to be established. A perspiration measurement system composed of several sensors was developed. We aim to estimate the measurement uncertainty of this system with several uncertainty sources, including airflow rate, air density, and inlet and outlet absolute humidity. Measurement uncertainty was evaluated and compared by the Guide to the expression of the uncertainty in measurement (GUM) method and Monte Carlo simulation. The standard uncertainty for the perspiration measurement system was 6.81 × 10−6 kg/s and the uncertainty percentage <10%. The major source of the uncertainty was airflow rate, and inlet and outlet absolute humidity. The Monte Carlo simulation could be executed easily with available spreadsheet software programs of the Microsoft Excel. GUM and Monte Carlo simulation did not differ in measurement uncertainty with precision to two decimal places. However, the sensitivity coefficient derived by GUM provided useful information to improve measurement performance, which was not evaluated with the Monte Carlo simulation method.  相似文献   

18.
In order to solve the shortcomings of the traditional transducers for monitoring the structural progressive collapse, this paper proposes to adopt the high-speed videogrammetric measurement technique to monitor the structural progressive collapse. First, the videogrammetric hardware components are presented. Second, three key issues about the stereo videogrammetric technique are studied in the paper, including camera calibration and placement, movable network control and tracking targets layout and image sequences processing. At last, three different kinds structural progressive collapse of five-story reinforced concrete frame-wall are performed, and the absolute accuracy of 0.43 mm, 0.87 mm and 0.65 mm and the relative accuracy of 0.61 mm, 0.29 mm and 0.62 mm are achieved in the X, Y and Z direction. The results show that the non-contacted videogrammetry is an alternative technique to monitor the structural progressive collapse.  相似文献   

19.
We developed a promising shearing force sensor that is small in size and can measure shearing force along two axes independently. This sensor consists of an elastic gum frame and an optical sensor chip (6 mm × 6 mm × 8 mm). From the experimental results, the resolutions of the sensor along the x- and y-axes are found to be 0.070 N and 0.063 N. We also experimentally demonstrated that the sensor can separately measure shearing force along two axes. Finally, we demonstrated that the scale factor which correspond to resolution and linear portion which correspond to measuring range of the signals can be changed easily by using three types of elastic gum frame. This sensor can be embedded in the finger of a robot hand and use it to not only measure shearing force but also detect the slip phenomenon.  相似文献   

20.
A shear mode micro-probing system was constructed for gap measurement of a precision slot die coater with a nominal gap width of 90 μm and a length of 200 mm. A glass micro-stylus with a nominal tip ball diameter of 52.6 μm was oscillated by a tuning fork quartz crystal resonator with its oscillation direction parallel to the measurement surfaces. An on-line qualification setup was established to compensate for the influences of the uncertainty sources, including the water layers on the measurement surfaces. The measurement uncertainty of the measured gap width was estimated to be less than 100 nm.  相似文献   