首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 64 毫秒
1.
Precise and accurate methods are required to measure nickel in urine and serum samples to identify clinical states of either deficiency or toxicity. This paper presents an isotope dilution gas chromatography/mass spectrometry method for the measurement of nickel in biological samples. The method involves the preparation of a thermally stable and volatile nickel chelate using lithium bis(trifluoroethyl)dithiocarbamate as the chelating agent. Conditions were optimized for the digestion of the sample and quantitative preparation of chelate as well as the precise and accurate measurements of the isotope ratios using a capillary column gas chromatograph with a general purpose mass spectrometer. The memory effect between samples of different isotope ratios was evaluated and was found to be negligible. The quantitative accuracy of isotope dilution was validated by measuring nickel in the NIST freeze-dried urine reference material, SRM 2670, with comparison to the recommended value.  相似文献   

2.
We describe a new chemical separation method to isolate Ca from other matrix elements in biological samples, developed with the long-term goal of making high-precision measurement of natural stable Ca isotope variations a clinically applicable tool to assess bone mineral balance. A new two-column procedure utilizing HBr achieves the purity required to accurately and precisely measure two Ca isotope ratios ((44)Ca/(42)Ca and (44)Ca/(43)Ca) on a Neptune multiple collector inductively coupled plasma mass spectrometer (MC-ICPMS) in urine. Purification requirements for Sr, Ti, and K (Ca/Sr > 10?000; Ca/Ti > 10?000?000; and Ca/K > 10) were determined by addition of these elements to Ca standards of known isotopic composition. Accuracy was determined by (1) comparing Ca isotope results for samples and standards to published data obtained using thermal ionization mass spectrometry (TIMS), (2) adding a Ca standard of known isotopic composition to a urine sample purified of Ca, and (3) analyzing mixtures of urine samples and standards in varying proportions. The accuracy and precision of δ(44/42)Ca measurements of purified samples containing 25 μg of Ca can be determined with typical errors less than ±0.2‰ (2σ).  相似文献   

3.
Analysis of perchlorate in water and soil by electrospray LC/MS/MS   总被引:1,自引:0,他引:1  
A method has been developed for the determination of perchlorate in water and soil matrixes using electrospray liquid chromatography/mass spectrometry/mass spectrometry. Perchlorate is quantitated by monitoring the ion signal from mass 83, which is formed by a loss of an oxygen atom from the perchlorate molecular ion. The method was developed to be effective and economical in production laboratory analysis of perchlorate in environmental water and soil samples. Data were gathered to define method sensitivity, performance, selectivity, and robustness. Analyte stability, method susceptibility to interferences, and the reliability of the chlorine isotope ratio as an identification tool were examined. The aqueous method detection limit (MDL) is 0.05 microg/L and was determined using an actual groundwater matrix. The soil MDL is 0.5 microg/kg and was determined using Ottawa sand. The stability study was performed by spiking water samples at 0.25, 10, and 20 microg/L and analyzing them 50 days later. Acceptable recoveries were obtained for all samples. The relative standard deviation (RSD) for the replicate analyses in the stability study indicates that the method is capable of RSD values less than 5% in a relatively clean groundwater matrix. The ionization suppression study was performed by spiking water samples containing 1000 mg/L carbonate, chloride, and sulfate with 0.05 and 0.5 microg/L perchlorate and then measuring the recovery of the spike. The results indicate that the procedure does not have significant suppression effects at the high salt levels tested. Calibration, quality control sample, field sample, and suppression study data were combined to examine isotope ratio reliability. The results of that work show that chlorine isotope ratios can be used to define statistical process control limits for use as an additional analyte identification tool.  相似文献   

4.
Intramolecular carbon isotope ratios reflect the source of a compound and the reaction conditions prevailing during synthesis and degradation. We report here a method for determination of relative (Deltadelta13C) and absolute (delta13C) intramolecular isotope ratios using the volatile lactic acid analogue propylene glycol as a model compound, measured by on-line gas chromatography-pyrolysis coupled to GC-combustion-isotope ratio mass spectrometry. Pyrolytic fragmentation of about one-third of the analyte mass produces optimal fragments for isotopic analysis, from which relative isotope ratios (Deltadelta13C) are calculated according to guidelines presented previously. Calibration to obtain absolute isotope ratios is achieved by quantifying isotope fractionation during pyrolysis with an average fractionation factor, alpha, and evaluated by considering extremes in isotopic fractionation behavior. The method is demonstrated by calculating ranges of absolute intramolecular isotope ratios in four samples of propylene glycol. Relative and absolute isotope ratios were calculated with average precisions of SD(Deltadelta13C) <0.84 per thousand and SD(delta13C) <3.0 per thousand, respectively. The various fractionation scenarios produce an average delta(13)C range of 2 per thousand for each position in each sample. Relative isotope ratios revealed all four samples originated from unique sources, with samples A, B, and D only distinguishable at the position-specific level. Regardless of pyrolysis fractionation distribution, absolute isotope ratios showed a consistent pattern for all samples, with delta13C(3) > delta13C(2) > delta13C(1). The validity of the method was determined by examining the difference in relative isotope ratios calculated through two independent methods: Deltadelta13C calculated directly using previous methods and Deltadelta13C extracted from absolute isotope ratios. Deviation between the two Deltadelta13C values for all positions averaged 0.1-0.2 per thousand, with the smallest deviation obtained assuming equal fractionation across all fragment positions. This approach applies generally to all compounds analyzed by pyrolytic PSIA.  相似文献   

5.
N-Methyl- and N-ethyl-2-pyrollidone (NMP and NEP) are frequently used industrial solvents and were shown to be embryotoxic in animal experiments. We developed a sensitive, specific, and robust analytical method based on cooled-injection (CIS) gas chromatography and isotope dilution mass spectrometry to analyze 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), two newly identified presumed metabolites of NEP, and their corresponding methyl counterparts (5-HNMP, 2-HMSI) in human urine. The urine was spiked with deuterium-labeled analogues of these metabolites. The analytes were separated from urinary matrix by solid-phase extraction and silylated prior to quantification. Validation of this method was carried out by using both, spiked pooled urine samples and urine samples from 56 individuals of the general population with no known occupational exposure to NMP and NEP. Interday and intraday imprecision was better than 8% for all metabolites, while the limits of detection were between 5 and 20 μg/L depending on the analyte. The high sensitivity of the method enables us to quantify NMP and NEP metabolites at current environmental exposures by human biomonitoring.  相似文献   

6.
Davis WE  Li Y 《Analytical chemistry》2008,80(14):5449-5453
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.  相似文献   

7.
A new method was developed for rapid and precise simultaneous determination of Mg/Ca, Sr/Ca, Mn/Ca, Cd/Ca, Ba/Ca and U/Ca ratios in foraminiferal shells using sector field inductively coupled plasma mass spectrometry (ICPMS). Element/calcium ratios were determined directly from intensity ratios using external, matrix-matched standard to correct for instrumental mass discrimination. Because of large differences in the abundance of chemical constituents of the foraminiferal shell, major elemental ratios were determined in analog mode (using (24)Mg, (43)Ca, (44)Ca, (55)Mn, and (88)Sr) whereas trace elemental ratios were determined in pulse-counting mode (using (111)Cd, (138)Ba, (238)U, and the low-abundance (46)Ca isotope). Matrix-induced variations in mass discrimination over a calcium concentration range of 2.0-24.5 mM were observed only for Mg/Ca and Cd/Ca ratios. However, these effects are negligible if the samples and standard calcium concentration are within a factor of 2-3. Multiratio method reproducibility was better than previously reported for other ICPMS methods yielding precision (1σ) of Sr/Ca = 0.45%; Mg/Ca = 0.45%, Mn/Ca = 0.8%, Cd/Ca = 1.7%, Ba/Ca = 0.7%, and U/Ca = 1.4% for foraminifera samples as small as 25 μg. Using this approach for a single-ratio analysis, Sr/Ca ratios were determined with precision of 0.06% (1σ) on carbonate samples as small as a single foraminifera shell (<10 μg). The new method is more sensitive, more precise, and simpler to use than previously available ICPMS techniques. It provides an efficient tool for simultaneous determination of several elemental ratios of paleoceanographic interest in a single foraminiferal sample, thereby reducing overall sample size requirement and analysis time.  相似文献   

8.
Determination of platinum in blood by adsorptive voltammetry   总被引:2,自引:0,他引:2  
This work describes a sensitive method for the determination of platinum in blood, which can be used for determining the natural levels of platinum in human blood, for monitoring patients treated with platinum cytotoxic drugs, and for monitoring occupational exposure to these drugs and other platinum compounds. The method involves dry ashing of blood samples in a muffle furnace and determination of platinum by adsorptive voltammetric (AV) measurement of the catalytic reduction of protons by the platinum-formazone complex. The detection limit for a 100-microL sample of blood is 0.017 micrograms/L, with a recovery of 94% and a relative standard deviation of 7% at a platinum level of 1 microgram/L. By using this method, the natural levels of platinum in human blood were found to be in the range 0.1-2.8 micrograms/L (median = 0.6 micrograms/L). These results were verified by inductively coupled plasma mass spectrometry (ICP-MS) with blood prepared by wet ashing and using gold as an internal standard.  相似文献   

9.
Down-scaling of a cocondensation method to produce volatile pentakis(trifluorophosphine)iron(0) for measuring isotope ratios by gas source mass spectrometry is described. Starting from 10 mg of iron, this method allows synthesis of a sufficient amount of Fe(PF(3))(5) that can be used to measure iron content and/or isotope ratios in real-life samples. The advantage over thermal ionisation mass spectrometry is that more precise determinations of ratios/amounts are possible. Reproducibilities for n((54)Fe)/n((56)Fe) and n((57)Fe)/n((56)Fe) are (1-3) × 10(-4), while those obtained by thermal ionization mass spectrometry are at the 10(-3) level.  相似文献   

10.
We have developed an isotope dilution high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method for quantifying the urinary metabolites of the pesticides atrazine, malathion, and 2,4-dichlorophenoxyacetic acid (2,4-D). Urine samples are extracted with an organic solvent, and the organic fraction is concentrated. The concentrate is then analyzed using HPLC/MS/MS. The limits of detection for the metabolites are less than 0.5 microgram/L (parts per billion) in 10 mL of urine, with a high degree of accuracy and precision.  相似文献   

11.
Chu S  Metcalfe CD 《Analytical chemistry》2007,79(13):5093-5096
Acrylamide is a probable human carcinogen, and the drinking water quality guideline for this compound is 0.5 mg/L. However, analysis of this compound in water is difficult because of its very high water solubility, which limits the efficiency of sample preconcentration prior to analysis. We developed a robust and sensitive analytical method for the determination of trace quantities of acrylamide in samples of water using a novel preparative technique and isotope dilution liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization as the ion source (LC-APCI-MS/MS). The preparative method involves coevaporation of acrylamide with water at pH 10 using a rotary evaporator, followed by acidification to pH 3.0 and concentration of the sample prior to analysis by LC-APCI-MS/MS. To compensate for the loss of the analyte during sample preparation and signal suppression due to interference from the sample matrix, isotope dilution with acrylamide-d3 was used for quantitation. Using this method, analyte recoveries ranged from 74 to 103% for acrylamide spiked into water at a concentration of 0.4 ng/mL. The limit of detection and limit of quantification (LOQ) for acrylamide in water were 0.02 and 0.06 ng/mL, respectively. This method was successfully applied to determine trace levels of acrylamide in samples of river water and in runoff from an agricultural field to which municipal biosolids (i.e., sludge) had been applied. Concentrations of acrylamide in these samples ranged from 相似文献   

12.
A new approach to the search for residues of known and unknown estrogens in calf urine is presented. Following enzymatic deconjugation and solid-phase extraction, a minor part of the samples is screened for estrogen activity using a recently developed rapid reporter gene bioassay. The remainder of the bioactive extracts is analyzed by gradient liquid chromatography (LC) with, in parallel, bioactivity and mass spectrometric detection via effluent splitting toward a 96-well fraction collector and an electrospray quadrupole time-of-flight mass spectrometer (QTOFMS). The LC fractions in the 96-well plate are used for the detection of estrogen activity using the bioassay. The biogram obtained features a 20-s time resolution, and the suspect well numbers can be easily correlated with the LC/QTOFMS retention time. The mass spectral data from the thus assigned relevant parts of the chromatograms are background subtracted, followed by accurate mass measurement, element composition calculation, and identification. The method allows estrogen activity detection and identification of (un)known estrogens in urine at the 1-2 ng/L level, in compliance with current residue analysis performance for hormone abuse in cattle. The applicability of this LC/bioassay/QTOFMS approach for the identification of estrogens in real-life samples is demonstrated by the analysis of several calf urine samples, and preliminary data from a pig feed sample.  相似文献   

13.
Chlorine stable isotope ratios, 37Cl/35Cl, currently are measured using dual-inlet and thermal-ionization mass spectrometry. These two different analytical techniques, however, have never been cross calibrated. A set of samples with chlorine stable isotope delta values ranging from -4.4 to +0.3 % relative to standard mean ocean water chloride has been analyzed using both of these techniques. Our data show that both techniques can yield similar results within analytical uncertainty. CsCl thermal ionization data are extremely sensitive to the amount of chlorine being measured and cannot be used to determine absolute ratios without an independent means of correcting for machine-induced mass fractionation. As long as standards and samples are of equivalent size, however, the differences between samples measured by thermal ionization remain constant Dual inlet stable isotope mass spectrometry is suited best for samples of > 10 micromol Cl, yielding chlorine stable isotope data with < or =0.1% reproducibilities (2sigma). Thermal ionization mass spectrometry easily accommodates samples of approximately0.1-0.3 micromol Cl, with achievable uncertainties of < or =0.2% (2sigma).  相似文献   

14.
A new method for the measurement of SI traceable carbon isotope amount ratios using a multicollector inductively coupled mass spectrometer (MC-ICPMS) is reported for the first time. Carbon (13)C/(12)C isotope amount ratios have been measured for four reference materials with carbon isotope amount ratios ranging from 0.010659 (delta(13)C(VPDB) = -46.6 per thousand) to 0.011601 (delta(13)C(VPDB) = +37 per thousand). Internal normalization by measuring boron (11)B/(10)B isotope amount ratios has been used to correct for the effects of instrumental mass bias. Absolute (13)C/(12)C ratios have been measured and corrected for instrumental mass bias and full uncertainty budgets have been calculated using the Kragten approach. Corrected (13)C/(12)C ratios for NIST RM8545 (Lithium Carbonate LSVEC), NIST RM8573 (L-Glutamic Acid USGS40), NIST RM8542 (IAEA-CH6 Sucrose) and NIST RM8574 (L-Glutamic Acid USGS41) differed from reference values by 0.06-0.20%. Excellent linear correlation (R = 0.9997) was obtained between corrected carbon isotope amount ratios and expected carbon isotope amount ratios of the four chosen NIST RMs. The method has proved to be linear within this range (from (13)C/(12)C = 0.010659 to (13)C/(12)C =0.011601), and therefore, it is suitable for the measurement of carbon isotope amount ratios within the natural range of variation of organic carbon compounds, carbonates, elemental carbon, carbon monoxide, and carbon dioxide. In addition, a CO2 gas sample previously characterized in-house by conventional dual inlet isotope ratio mass spectrometry has been analyzed and excellent agreement has been found between the carbon isotope amount ratio value measured by MC-ICPMS and the IRMS measurements. Absolute values for carbon isotope amount ratios traceable to the SI are given for each NIST RM, and the combined uncertainty budget (including instrumental error and each parameter contributing to Russell expression for mass bias correction) has been found to be < 0.1% for the four materials. The advantage of the method versus conventional gas source isotope ratio mass spectrometry measurements is that carbon isotope amount ratios are measured as C(+) instead of CO2(+), and therefore, an oxygen (17)O correction due to the presence of (12)C(17)O(16)O(+) is not required. Organic compounds in solution can be measured without previous derivatization, combustion steps, or both, thus making the process simple. The novel methodology opens new avenues for the measurement of absolute carbon isotope amount ratios in a wide range of samples.  相似文献   

15.
The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of 238U in 20 wells and lake water samples were checked from the viewpoint of internal radiation exposure for South Serbian subjects. We have measured 238U concentration using inductively coupled plasma mass spectrometry, whereas thermal ionisation mass spectrometry has been used for the measurement of isotope ratios, e.g. 234U/238U and 235U/238U. The concentration of uranium in water samples varies in the range 1.37-63.18 mBq/L. 234U belongs to the 238U natural radioactive decay series, and at secular equilibrium, the abundance ratio, 234U/238U, corresponds to the ratio of their half-lives. The 234U/238U activity ratio varies in the range 0.88-2.2 and 235U/238U isotope ratio varies from 0.00698 to 0.00745. These findings indicate that uranium in water was a mixture of natural and anthropogenic origin. The annual effective dose due to 238U was estimated to be in the range 9.2 x 10(-5)-2.1 x 10(-3) mSv.  相似文献   

16.
The direct injection high efficiency nebulizer (DIHEN) was explored for the ultrasensitive determination of long-lived radionuclides ((226)Ra, (230)Th, (237)Np, (238)U, (239)Pu, and (241)Am) and for precise isotope analysis by inductively coupled plasma mass spectrometry (ICPMS). The DIHEN was used at low solution uptake rates (1-100 μL/min) without a spray chamber. Optimal sensitivity (e.g., (238)U, 230 MHz/ppm; (230)Th, 190 MHz/ppm; and (239)Pu, 184 MHz/ppm) was achieved at low nebulizer gas flow rates (0.16 L/min), high rf power (1450 W), and low solution uptake rates (100 μL/min). The optimum parameters varied slightly for the two DIHENs tested. The detection limits of long-lived radionuclides in aqueous solutions varied from 0.012 to 0.11 ng/L. The sensitivity of the DIHEN was improved by a factor of 3 to 5 compared with that of a microconcentric nebulizer (MicroMist used with a minicyclonic spray chamber at a solution uptake rate of 85 μL/min) and a factor of 1.5 to 4 compared with that of a conventional nebulizer (cross-flow used with a Scott type spray chamber at a solution uptake rate of 1 mL/min). The precision of the DIHEN ranged from 0.5 to 1.7% RSD (N = 3) for all measurements at the 10 ng/L concentration level (~3 pg sample size). The sensitivity decreased to 10 MHz/ppm at a solution uptake rate of 1 μL/min. The precision was about 5% RSD at a sample size of 30 fg for each long-lived radionuclide by the DIHEN-ICPMS method. The oxide to atom ratios were less than 0.05 (except ThO(+)/Th(+) ) and decreased under the optimum conditions in the following sequence: ThO(+)/Th(+) > UO(+)/U(+) > NpO(+)/Np(+) > PuO(+)/Pu(+) > AmO(+)/Am(+) > RaO(+)/Ra(+). Atomic and oxide ions were used as analyte ions for ultratrace and isotope analyses of long-lived radionuclides in environmental and radioactive waste samples. The analytical methods developed were applied to the determination of long-lived radionuclides and isotope ratio measurements in different radioactive waste and environmental samples using the DIHEN in combination with quadrupole ICPMS. For instance, the (240)Pu/(239)Pu isotope ratio was measured in a radioactive waste sample at a plutonium concentration of 12 ng/L. This demonstrates a main advantage of DIHEN-ICPMS compared with α-spectrometry, which cannot be used to selectively determine (239)Pu and (240)Pu because of similar α energies (5.244 and 5.255 MeV, respectively).  相似文献   

17.
19-Norandrosterone (19-NA) is the major metabolite of the steroid nandrolone, one of the most commonly abused anabolic androgenic agents. 19-NA exists mainly as the glucuronide form in human urine. A candidate reference measurement procedure for 19-NA in urine involving isotope dilution coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The 19-NA glucuronide was enzymatically hydrolyzed, and the 19-NA along with its internal standard (deuterated 19-NA) was extracted from urine using liquid-liquid extraction prior to reversed-phase LC/MS/MS. The accuracy of the measurement of 19-NA was evaluated by a recovery study of added 19-NA. The recovery of the added 19-NA ranged from 99.1 to 101.4%. This method was applied to the determination of 19-NA in urine samples fortified with 19-NA glucuronide at three different concentrations (equivalent to 1, 2, and 10 ng/mL 19-NA). Excellent reproducibility was obtained with within-set coefficients of variation (CVs) ranging from 0.2 to 1.2%, and between-set CVs ranging from 0.1 to 0.5%. Excellent linearity was also obtained with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.9997 to 0.9999. The detection limit for 19-NA at a signal-to-noise ratio of approximately 3 was 16 pg. The mean results of 19-NA yielded from hydrolysis of 19-NA glucuronide compared well with the theoretical values (calculated from the conversion of 19-NA glucuronide to 19-NA) with absolute relative differences ranging from 0.2 to 1.4%. This candidate reference measurement procedure for 19-NA in urine, which demonstrates good accuracy and precision and low susceptibility to interferences, can be used to provide an accuracy base to which routine methods for 19-NA can be compared and that will serve as a standard of higher order for measurement traceability.  相似文献   

18.
We applied a photoacoustic spectroscopy technique to isotope ratio measurements of (16)O and (18)O in water-vapor samples, using a pulsed tunable dye laser pumped by a Nd:YAG laser. The fourth overtone bands (4nu(OH)) of water molecules near 720 nm were investigated. We identified the absorption lines of H(2)(16)O and H(2)(18)O in the photoacoustic spectra that we measured by using an (18)O-enriched water sample and the HITRAN database. We measured the difference in the (18)O/(16)O isotope ratios for normal distilled water and Antarctic ice, using the photoacoustic method. The value obtained for the difference between the two samples is delta(18)O = -32 ? 16 per thousand, where the indicated deviation was a 1varsigma value among 240-s measurements, whereas the value measured with a conventional isotope mass spectrometer was delta(18)O = -28 ? 2 per thousand. This method is demonstrated to have the potential of a transportable system for in situ and quick measurements of the H(2)(18)O/H(2)(16)O ratio in the environment.  相似文献   

19.
Solidified floating organic drop microextraction (SFODME) method in combination with graphite furnace atomic absorption spectrometry (GFAAS) has been used for the determination of chromium species in water and urine samples. 1-undecanol containing 2-thenoyltrifluoroacetone (TTA) was used as a selective chelating agent for the extraction of Cr(III). The total Cr was determined after the reduction of Cr(VI) to Cr(III) with hydroxylamine. The concentration of Cr(VI) was determined from the difference between the concentration of total chromium and the Cr(III). Several variables such as the sample pH, concentration of TTA, salt concentration, extraction time and the sample volume were investigated in detail. Under the optimum conditions, the limit of detection of the proposed method was 0.006 μg l(-1) for Cr(III) and the relative standard deviation for six replicate determinations at 0.1 μg l(-1) Cr(III) was 5.1%. The proposed method was successfully applied for the determination of chromium species in tap water, well water, mineral water, and urine samples.  相似文献   

20.
This work introduces a newly developed on-line flow injection (FI) Sr/Rb separation method as an alternative to the common, manual Sr/matrix batch separation procedure, since total analysis time is often limited by sample preparation despite the fast rate of data acquisition possible by inductively coupled plasma-mass spectrometers (ICPMS). Separation columns containing approximately 100 muL of Sr-specific resin were used for on-line FI Sr/matrix separation with subsequent determination of (87)Sr/(86)Sr isotope ratios by multiple collector ICPMS. The occurrence of memory effects exhibited by the Sr-specific resin, a major restriction to the repetitive use of this costly material, could successfully be overcome. The method was fully validated by means of certified reference materials. A set of two biological and six geological Sr- and Rb-bearing samples was successfully characterized for its (87)Sr/(86)Sr isotope ratios with precisions of 0.01-0.04% 2 RSD (n = 5-10). Based on our measurements we suggest (87)Sr/(86)Sr isotope ratios of 0.713 15 +/- 0.000 16 (2 SD) and 0.709 31 +/- 0.000 06 (2 SD) for the NIST SRM 1400 bone ash and the NIST SRM 1486 bone meal, respectively. Measured (87)Sr/(86)Sr isotope ratios for five basalt samples are in excellent agreement with published data with deviations from the published value ranging from 0 to 0.03%. A mica sample with a Rb/Sr ratio of approximately 1 was successfully characterized for its (87)Sr/(86)Sr isotope signature to be 0.718 24 +/- 0.000 29 (2 SD) by the proposed method. Synthetic samples with Rb/Sr ratios of up to 10/1 could successfully be measured without significant interferences on mass 87, which would otherwise bias the accuracy and uncertainty of the obtained data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号