首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for the characterization of aromatic compounds present in extra heavy gas oil (EHGO) from Brazil. Individual identification of EHGO compounds was successfully achieved in addition to group-type separation on the chromatographic plane. Many aromatic hydrocarbons, especially polycyclic aromatic hydrocarbons and sulfur compounds, were detected and identified, such as chrysenes, phenanthrenes, perylenes, benzonaphthothiophenes and alkylbenzonaphthothiophenes. In addition, triaromatic steroids, methyl-triaromatic steroids, tetrahydrochrysenes and tetraromatic pentacyclic compounds were present in the EHGO aromatic fractions. Considering the roof-tile effect observed for many of these compound classes and the high number of individual compounds identified, GC×GC-TOFMS is an excellent technique to characterize the molecular composition of the aromatic fraction from EHGO samples. Moreover, data processing allowed the quantification of aromatic compounds, in class and individually, using external standards. EHGO data were obtained in μgg(-1), e.g., benzo[a]pyrene were in the range 351 to 1164μgg(-1). Thus, GC×GC-TOFMS was successfully applied in EHGO quantitative analysis.  相似文献   

2.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration.  相似文献   

3.
Polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) are listed as persistent organic pollutants (POPs) under the Stockholm Convention. Because they have similar physical and chemical properties, they are coeluted and are usually analyzed separately by different gas chromatography high-resolution mass spectrometry (GC-HRMS) methods. In this study, a novel method was developed for simultaneous analysis of six indicator PCBs, 12 dioxin-like PCBs, and 16 PCNs using isotope dilution comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HRTOF-MS). The method parameters, including the type of GC column, oven temperature program, and modulation period, were systematically optimized. Complete separation of all target analytes and the matrix was achieved with a DB-XLB column in the first dimension and a BPX-70 column in the second dimension. The isotope dilution method was used for quantification of the PCBs and PCNs by GC × GC-HRTOF-MS. The method showed good linearity from 5 to 500 pg μL−1 for all the target compounds. The instrumental limit of detection ranged from 0.03 to 0.3 pg μL−1 for the 18 PCB congeners and from 0.09 to 0.6 pg μL−1 for the 16 PCN congeners. Repeatability for triplicate injections was always lower than 20%. The method was successfully applied to the determination of 18 PCBs present at 0.9–2054 pg g−1 and 16 PCNs present at 0.2–15.7 pg g−1 in three species of fish. The GC × GC-HRTOF-MS results agreed with those obtained by GC-HRMS. The GC × GC-HRTOF-MS method proved to be a sensitive and accurate technique for simultaneous analysis of the selected PCBs and PCNs. With the excellent chromatographic separation offered by GC × GC and accurate mass measurements offered by HRTOF-MS, this method allowed identification of non-target contaminants in the fish samples, including organochlorine pesticides and polycyclic aromatic hydrocarbons.  相似文献   

4.
Reichenbach SE  Tian X  Tao Q  Ledford EB  Wu Z  Fiehn O 《Talanta》2011,83(4):1279-1288
This paper describes informatics for cross-sample analysis with comprehensive two-dimensional gas chromatography (GCxGC) and high-resolution mass spectrometry (HRMS). GCxGC-HRMS analysis produces large data sets that are rich with information, but highly complex. The size of the data and volume of information requires automated processing for comprehensive cross-sample analysis, but the complexity poses a challenge for developing robust methods. The approach developed here analyzes GCxGC-HRMS data from multiple samples to extract a feature template that comprehensively captures the pattern of peaks detected in the retention-times plane. Then, for each sample chromatogram, the template is geometrically transformed to align with the detected peak pattern and generate a set of feature measurements for cross-sample analyses such as sample classification and biomarker discovery. The approach avoids the intractable problem of comprehensive peak matching by using a few reliable peaks for alignment and peak-based retention-plane windows to define comprehensive features that can be reliably matched for cross-sample analysis. The informatics are demonstrated with a set of 18 samples from breast-cancer tumors, each from different individuals, six each for Grades 1-3. The features allow classification that matches grading by a cancer pathologist with 78% success in leave-one-out cross-validation experiments. The HRMS signatures of the features of interest can be examined for determining elemental compositions and identifying compounds.  相似文献   

5.
A method for the analysis of chlorinated and brominated polycyclic aromatic hydrocarbon (Cl-/Br-PAHs) congeners in environmental samples, such as a soil extract, by comprehensive two-dimensional gas chromatography coupled to a high resolution time-of-flight mass spectrometry (GC×GC-HRTOF-MS) is described. The GC×GC-HRTOF-MS method allowed highly selective group type analysis in the two-dimensional (2D) mass chromatograms with a very narrow mass window (e.g. 0.02Da), accurate mass measurements for the full mass range (m/z 35-600) in GC×GC mode, and the calculation of the elemental composition for the detected Cl-/Br-PAH congeners in the real-world sample. Thirty Cl-/Br-PAHs including higher chlorinated 10 PAHs (e.g. penta, hexa and hepta substitution) and ClBr-PAHs (without analytical standards) were identified with high probability in the soil extract. To our knowledge, highly chlorinated PAHs, such as C(14)H(3)Cl(7) and C(16)H(3)Cl(7), and ClBr-PAHs, such as C(14)H(7)Cl(2)Br and C(16)H(8)ClBr, were found in the environmental samples for the first time. Other organohalogen compounds; e.g. polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), and polychlorinated dibenzofurans (PCDFs) were also detected. This technique provides exhaustive analysis and powerful identification for the unknown and unconfirmed Cl-/Br-PAH congeners in environmental samples.  相似文献   

6.
A new method has been developed to detect 36 pesticides that may contaminate tea samples (green, black and fruit tea). The hyphenation of solid-phase microextraction in head-space mode with a comprehensive two-dimensional gas chromatography coupled with high-speed time-of-flight mass spectrometry (HS-SPME-GC × GC/TOF MS) proved to be a quick alternative to conventional GC/MS methodology which employs solvent-based extraction. The key parameters for controlling HS-SPME performance were optimized, including fiber coating type, temperature and absorption time settings and tea matrix modification by adding water. Quantification was carried out using matrix-matched calibration. The repeatability of measurements, expressed as relative standard deviation (R.S.D.), was less than 24% for all analytes. The limits of quantification ranged from 1 to 28 μg kg−1. The optimized method was applied to analyze real life samples obtained from a retail market. Results generated by the new SPME procedure and those obtained by using a conventional one involving ethyl acetate extraction and high-performance gel permeation chromatography (HPGPC) clean up agreed with each other for positive (containing residue) samples.  相似文献   

7.
The estimation of physicochemical parameters such as distillation points and relative densities still plays an important role in the quality control of gasoline and similar fuels. Their measurements according to standard ASTM procedures demands specific equipments and are time and work consuming. An alternative method to predict distillation points and relativity density by multivariate analysis of comprehensive two-dimensional gas chromatography with flame ionization detection (GC×GC-FID) data is presented here. Gasoline samples, previously tested according to standard methods, were used to build regression models, which were evaluated by external validation. The models for distillation points were built using variable selection methods, while the model for relativity density was built using the whole chromatograms. The root mean square prediction differences (RMSPD) obtained were 0.85%, 0.48%, 1.07% and 1.71% for 10, 50 and 90% v/v of distillation and for the final point of distillation, respectively. For relative density, the RMSPD was 0.24%. These results suggest that GC×GC-FID combined with multivariate analysis can be used to predict these physicochemical properties of gasoline.  相似文献   

8.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

9.
First, standard mixtures of trimethylsilyl (TMS) derivatives of amino acid and organic acid are analyzed by comprehensive two-dimensional (2D) gas chromatography (GC) coupled to time-of-flight mass spectrometry (GC × GC/TOFMS) in order to illustrate important issues regarding application of the technique. Specifically of interest is the extent to which the peak capacity of the 2D separation space has been utilized and the procedure by which the derivative standards are identified in the 2D separations using the mass spectral information. The resulting 2D separation is found to make extensive use of the GC × GC separation space provided by the complementary stationary phases employed.Second, in order to demonstrate GC × GC/TOFMS on two real sample types, trimethylsilyl metabolite derivatives were analyzed from extracts of common lawn grass samples (i.e., perennial rye grass), as a means to provide insight into both the pre and post harvest physiology. Various chemical components in the two rye grass extract samples were found to either emerge or disappear in relation to the trauma response. For example, a significant difference in the peak for the TMS derivative of malic acid was found. The successful analysis of various components was readily facilitated by the 2D separation, while a 1D separation would have produced too much peak overlap, thus impeding the analysis. The importance of using a GC × GC separation approach for the analysis of complex samples, such as metabolite extracts, is therefore demonstrated. The real-time analysis capability of GC × GC/TOFMS for multidimensional metabolite analysis makes this technique well suited to the high-throughput analysis of metabolomic samples, especially compared to slower, stopped-flow type separation approaches.  相似文献   

10.
The present research is focused on the development of a comprehensive two-dimensional gas chromatography–rapid scanning quadrupole mass spectrometric (GC x GC-qMS) methodology for the analysis of trace-amount pesticides contained in a complex real-world sample. Reliable peak assignment was carried out by using a recently developed, dedicated pesticide MS library (for comprehensive GC analysis), characterized by a twin-filter search procedure, the first based on a minimum degree of spectral similarity and the second on the interactive use of linear retention indices (LRI). The library was constructed by subjecting mixtures of commonly used pesticides to GC x GC-qMS analysis and then deriving their pure mass spectra and LRI values. In order to verify the effectiveness of the approach, a pesticide-contaminated red grapefruit extract was analysed. The certainty of peak assignment was attained by exploiting both the enhanced separation power of dual-oven GC x GC and the highly effective search procedure.  相似文献   

11.
The applicability of comprehensive two-dimensional gas chromatography (GC×GC) for flavonoids analysis was investigated by separation and identification of flavonoids in standards, and a complex matrix natural sample. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of flavonoids was compared on two complementary column sets. Whilst the BPX5/BPX50 (NP/P) column set offers better overall separation, BPX50/BPX5 (P/NP) provides better peak shape and sensitivity. Comparison of the identification power of GC×GC-TOFMS against both the NIST05 MS library and a laboratory (created in-house) TOFMS library was carried out on a flavonoid mixture. The basic retention index information on high-performance capillary columns with a non-polar stationary phase was established and database of mass spectra of trimethylsilyl derivatives of flavonoids was compiled. TOFMS coupled to GC×GC enabled satisfactory identification of flavonoids in complex matrix samples at their LOD over a range of 0.5-10 μg/mL. Detection of all compounds was based on full-scan mass spectra and for each compound a characteristic ion was chosen for further quantification. This study shows that GC×GC-TOFMS yields high specificity for flavonoids derived from real natural samples, dark chocolate, propolis, and chrysanthemum.  相似文献   

12.
A method was developed to calculate the second dimension retention index of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) data using n-alkanes as reference compounds. The retention times of the C(7)-C(31) alkanes acquired during 24 isothermal experiments cover the 0-6s retention time area in the second dimension retention time space, which makes it possible to calculate the retention indices of target compounds from the corresponding retention time values without the extension of the retention space of the reference compounds. An empirical function was proposed to show the relationship among the second dimension retention time, the temperature of the second dimension column, and the carbon number of the n-alkanes. The proposed function is able to extend the second dimension retention time beyond the reference n-alkanes by increasing the carbon number. The extension of carbon numbers in reference n-alkanes up to two more carbon atoms introduces <10 retention index units (iu) of deviation. The effectiveness of using the proposed method was demonstrated by analyzing a mixture of compound standards in temperature programmed experiments using 6 different initial column temperatures. The standard deviation of the calculated retention index values of the compound standards fluctuated from 1 to 12 iu with a mean standard deviation of 5 iu.  相似文献   

13.
Abstract

Punica granatum L., commonly known as pomegranate, is an ancient fruit widely consumed all over the world as fresh fruit or juice. In addition, it is extensively used in therapeutic formulas, cosmetics and food seasonings. The fruit is native to Afghanistan, Iran, China and the Indian sub-continent. The pomegranate market has steadily grown, presumably due to the increasing demand of health-conscious consumers for products with potential beneficial effects on human health, due to the synergistic presence of a unique and complex phytochemical composition that enclose anthocyanins, phenolic acids and hydrolysable tannins. Conventionally, for their analysis liquid chromatography is employed even though it can present some drawbacks in terms of resolving power. In this contribution, as a valuable alternative, comprehensive two-dimensional liquid chromatography with “shifted gradients” in the second dimension, was applied for the characterization of three pomegranate samples, leading to the identification of 37 different polyphenolic compounds.  相似文献   

14.
Multidimensional gas-chromatographical analysis of various tensides of natural or synthetic origin in cosmetic products is demonstrated. Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry allows the qualitative and quantitative determination of alkyl polyglucosides (AG), fatty alcohol ethoxylates (FAEO), fatty alcohol sulfates (FAS), fatty alcohol ether sulfates (FAES) and cocamidopropyl betaines (CAPB) in shower gel and cleaning agents. The samples were aliquoted in two parts. The first part was silylated, diluted and analysed; then, in order to detect anionic tensides (FAES, FAS) too, the second aliquot was hydrolysed before being silylated for analysis. Because of their amphoteric character, the betaines can only be analysed by gas chromatography after thermal decomposition in the injector, which leads to the corresponding amidoamines among other products.  相似文献   

15.
Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples.  相似文献   

16.
In this work the higher peak capacity and resolution of comprehensive two-dimensional gas chromatography (GCxGC) has been successfully applied, for the first time, to tentatively identify several polar organic compounds of organic extracts of aqueous phases resulting from microwave demulsification process of water-in-crude oil emulsions. Results have shown that higher temperatures and longer exposure time to microwave irradiation produced water phases with a wider variety of polar organic compounds. The microwave process showed to be suitable for the extraction of several polar compounds classes of petroleum. The proposed microwave extraction method and GCxGC identification of polar compounds of petroleum samples are of practical interest for the petrochemical industry due to corrosion and related problems associated with these polar compounds in refinery equipments. The GCxGC/time-of-flight MS technique shows to be very important in the total separation of different classes of compounds and allows the identification of many compounds in these classes.  相似文献   

17.
A previously constructed semi-rotating cryogenic modulator was modified for comprehensive two-dimensional gas chromatography (GC×GC). The retention time repeatability was improved by replacing the modulator control program unit with a new system. Peak widths obtained with the modified modulator were comparable with those obtained with the previous modulator and other modulator types. The modulator was easy to construct and it can be installed in any commercial GC system. The constructed GC×GC–FID system and data obtained by gas chromatography–mass spectrometry (GC–MS) were used for identification of unknowns in forest aerosol samples. Figure A semi-rotating cryogenic modulator in which modulation is based on two-step cryogenic trapping with continuously flowing carbon dioxide has been developed for comprehensive two-dimensional gas chromatography  相似文献   

18.
Comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS) is a powerful tool for comprehensive analysis of organic pollutants. In this study, we developed a powerful analytical method using GC × GC for rapid and accurate identification and quantification of compounds in environmental samples with complex matrices. Specifically, we have developed an automatic peak sentinel tool, T-SEN, with free programming software, R. The tool, which consists of a simple algorithm for on peak finding and peak shape identification, allows rapid screening of target compounds, even for large data sets from GC × GC coupled to high resolution time of flight mass spectrometry (HRTOFMS). The software tool automatically assigns and quantifies compounds that are listed in user databases. T-SEN works on a typical 64 bit workstation, and the reference calculation speed is 10–20 min for approximately 170 compounds for peak finding (five ion count setting) and integration from 1–2 GB of sample data acquired by GC × GC–HRTOFMS. We analyzed and quantified 17 PCDD/F congeners and 24 PCB congeners in a crude lake sediment extract by both GC × GC coupled to quadrupole mass spectrometry (qMS) and GC × GC–HRTOFMS with T-SEN. While GC × GC–qMS with T-SEN resulted in false identification and inaccurate quantification, GC × GC–HRTOFMS with T-SEN provided correct identification and accurate quantification of compounds without sample pre-treatment. The differences between the values measured by GC × GC–HRTOFMS with T-SEN and the certified values for the certified reference material ranged from 7.3 to 36.9% for compounds with concentrations above the limit of quantification. False positives/negatives were not observed, except for when co-elution occurred. The technique of GC × GC–HRTOFMS in combination with T-SEN provides rapid and accurate screening and represents a powerful new approach for comprehensive analysis.  相似文献   

19.
Future understanding of differences in the composition and sensory attributes of wines require improved analytical methods which allow the monitoring of a large number of volatiles including those present at low concentrations. This study presents the optimization and application of a headspace solid-phase microextraction (HS-SPME) method for analysis of wine volatiles by comprehensive two-dimensional gas chromatography (GC×GC) time-of-flight mass spectrometry (TOFMS). This study demonstrates an important advancement in wine volatile analysis as the method allows for the simultaneous analysis of a significantly larger number of compounds found in the wine headspace compared to other current single dimensional GC-MS methodologies. The methodology allowed for the simultaneous analysis of over 350 different tentatively identified volatile and semi-volatile compounds found in the wine headspace. These included potent aroma compound classes such as monoterpenes, norisoprenoids, sesquiterpenes, and alkyl-methoxypyrazines which have been documented to contribute to wine aroma. It is intended that wine aroma research and wine sensory research will utilize this non-targeted method to assess compositional differences in the wine volatile profile.  相似文献   

20.
A method is presented to facilitate the non-target analysis of data obtained in temperature-programmed comprehensive two-dimensional (2D) gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-ToF-MS). One main difficulty of GC×GC data analysis is that each peak is usually modulated several times and therefore appears as a series of peaks (or peaklets) in the one-dimensionally recorded data. The proposed method, 2DAid, uses basic chromatographic laws to calculate the theoretical shape of a 2D peak (a cluster of peaklets originating from the same analyte) in order to define the area in which the peaklets of each individual compound can be expected to show up. Based on analyte-identity information obtained by means of mass spectral library searching, the individual peaklets are then combined into a single 2D peak. The method is applied, amongst others, to a complex mixture containing 362 analytes. It is demonstrated that the 2D peak shapes can be accurately predicted and that clustering and further processing can reduce the final peak list to a manageable size.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号

京公网安备 11010802026262号