 共查询到20条相似文献,搜索用时 15 毫秒
1.
Treatment of fresh air in ventilation systems for air-conditioned offices consumes a significant amount of energy and affects the indoor air quality (IAQ). In this study, energy impact on the ventilation systems was examined against certain IAQ objectives for indoor airborne bacteria exposure risk in air-conditioned offices of Hong Kong. The relationship between thermal energy consumptions and indoor airborne bacteria exposure levels based on regional surveys was investigated. The thermal energy consumptions of ventilation systems operating for carbon dioxide (CO2) exposure concentrations between 800 and 1200 ppmv for typical office buildings and the corresponding failure probability against some target bacteria exposure levels were evaluated. The results showed that, for a reference indoor environment at a CO2 exposure concentration of 1000 ppmv, the predicted average thermal energy saving of ventilation system for a unit increment of the expected risk of unsatisfactory IAQ of 1% was 55 MJ m−2 yr−1 and for a unit decrement of 1%, the predicted additional thermal energy consumption was 58 MJ m−2 yr−1 respectively. This study would be a useful source of reference in evaluation of the energy performance of ventilation strategies in air-conditioned offices at a quantified exposure risk of airborne bacteria.  相似文献   

2.
Wang GP  Liu JS  Tang J 《Water research》2004,38(20):1927-4474
Sediment cores, representing a range of watershed characteristics and anthropogenic impacts, were collected from two freshwater marshes at the Xianghai wetlands (Ramsar site no. 548) in order to trace the historical variation of nutrient accumulation. Cores were 210Pb- and 137Cs-dated, and these data were used to calculate sedimentation rates and sediment accumulation rates. Ranges of dry mass accumulation rates and sedimentation rates were 0.27–0.96 g m−2 yr−1 and 0.27–0.90 cm yr−1, respectively. The effect of human activities on increased sediment accumulation rates was observed. Nutrients (TOC, N, P, and S) in sediment were analyzed and nutrient concentration and accumulation were compared in two marshes with different hydrologic regime: an “open” marsh (E-0) and a partly “closed” marsh (F-0). Differences in physical and chemical characteristics between sediments of “open” and partly “closed” marsh were also observed. The “open” marsh sequestered much higher amounts of TOC (1.82%), N (981.1 mg kg−1), P (212.17 mg kg−1), and S (759.32 mg kg−1) than partly “closed” marsh (TOC: 0.32%, N: 415.35 mg kg−1, P: 139.64 mg kg−1, and S: 624.45 mg kg−1), and the “open” marsh indicated a rather large historical variability of TOC, N, P, and S inputs from alluvial deposits. Nutrient inputs (2.16–251.80 g TOC m−2 yr−1, 0.43–20.12 g N m−2 yr−1, 0.39–3.03 g P m−2 yr−1, 1.60–15.13 g S m−2 yr−1) into the Xianghai wetlands of China are in the high range compared with reported nutrient accumulation rates for freshwater marshes in USA. The vertical variation, particularly for N, P, and S indicated the input history of the nutrients of the Xianghai wetlands developed in three periods—before 1950s, 1950–1980s, and after 1980s. The ratios between anthropogenic and natural inputs showed that the relative anthropogenic inputs of TOC, N, P, and S have been severalfold (TOC: 1.68–11.21, N: 0.47–3.67, P: 0.24–1.36, and S: 1.46–2.96) greater than values of their natural inputs after 1980s. The result is probably attributable, in part, to two decades of surface coal mining activities, urban sewage, and agriculture runoff within the upstream region of the Huolin River. Our findings suggest that the degree of anthropogenic disturbance within the surrounding watershed regulates wetland sediment, TOC, N, P, and S accumulation.  相似文献   

3.
Adjustment of the indoor air temperature and relative humidity set points for energy conservation is adopted in many air-conditioned offices in the subtropics. This study examines the environmental risks in an air-conditioned office with a ‘readjusted’ thermal environment from the perspective of the probable airborne bacteria level exceeding certain limits. In particular, a cross-sectional study of bacteria concentrations in 422 air-conditioned offices in Hong Kong was conducted, and a mathematical expression was proposed to correlate the indoor bacteria level with the indoor air temperature and relative humidity in an air-conditioned office. With the proposed correlation, the probability of an air-conditioned office having an unsatisfactory airborne bacteria level could be determined. The model results were verified with the measurement results from some other studies. This model would be a useful tool for preliminary assessment of the environmental risks, regarding the airborne bacteria level while balancing some energy conservation measures, in an air-conditioned office in the subtropics. The study also provides a template for developing an environmental risk assessment model in air-conditioned spaces elsewhere.  相似文献   

4.
Average annual electricity use per gross floor area is 236kWh/m2yr for offices and 366kWh/m2yr for hotels. HVAC and lighting account for 70-80% of total energy in fully air-conditioned commercial buildings in Hong Kong and should be a priority for energy management programmes.  相似文献   

5.
The aims of this study were to demonstrate the (1) feasibility of psychrophilic, or low-temperature, anaerobic digestion (PAD) of phenolic wastewaters at 10–15 °C; (2) economic attractiveness of PAD for the treatment of phenol as measured by daily biogas yields and (3) impact on bioreactor performance of phenol loading rates (PLRs) in excess of those previously documented (1.2 kg phenol m−3 d−1). Two expanded granular sludge bed (EGSB)-based bioreactors, R1 and R2, were employed to mineralise a volatile fatty acid-based wastewater. R2 influent wastewater was supplemented with phenol at an initial concentration of 500 mg l−1 (PLR, 1 kg m−3 d−1). Reactor performance was measured by chemical oxygen demand (COD) removal efficiency, CH4 composition of biogas and phenol removal (R2 only). Specific methanogenic activity, biodegradability and toxicity assays were employed to monitor the physiological capacity of reactor biomass samples. The applied PLR was increased to 2 kg m−3 d−1 on day 147 and phenol removal by day 415 was 99% efficient, with 4 mg l−1 present in R2 effluent. The operational temperature of R1 (control) and R2 was reduced by stepwise decrements from 15 °C through to a final operating temperature of 9.5 °C. COD removal efficiencies of c. 90% were recorded in both bioreactors at the conclusion of the trial (day 673), when the phenol concentration in R2 effluent was below 30 mg l−1. Daily biogas yields were determined during the final (9.5 °C) operating period, when typical daily R2 CH4 yields of c. 3.3 l CH4 g−1 CODremoved d−1 were recorded. The rate of phenol depletion and methanation by R2 biomass by day 673 were 68 mg phenol g VSS−1 d−1 and 12–20 ml CH4 g VSS−1 d−1, respectively.  相似文献   

6.
《Energy and Buildings》2001,33(8):793-803
Lighting control integrated with daylighting is recognised as an important and useful strategy in energy-efficient building designs and operations. It is believed that proper daylighting schemes can help reduce the electrical demand and contribute to achieving environmentally sustainable building development. This paper presents field measurements on daylighting for a fully air-conditioned office building in Hong Kong. Electricity consumption by the fluorescent luminaires, indoor illuminance levels and the room parameters affecting daylighting designs were recorded and analysed. The measurements covered several cellular offices facing opposite orientations with and without daylighting controls. The findings suggest that daylighting schemes can result in substantial energy savings in air-conditioned office buildings in Hong Kong. Results are presented and the design implications are discussed.  相似文献   

7.
Phytoplankton biomass and production in the river meuse (Belgium)   总被引:8,自引:0,他引:8  
The biomass and production of the phytoplankton in a relatively unpolluted reach of the River Meuse (Belgium) were followed through two years (1983 and 1984). Chlorophyll a varied from 0.2 to about 120 mg m−3, and production ranged between 0.05 and 5.78 gC m−2 d−1. The mean photosynthetic quotient (PQ) was 1.25.

The parameters of the light-photosynthesis relationship (Popt and lk) were calculated and related to the variations of temperature and light in the water column. A simple model allowed calculations of the annual production, which was estimated to be 494 gC m−2 yr−1 in 1983 and 547 gC m−2 yr−1 in 1984.

Finally, a simple model is developed, which explains the relationship between phytoplankton development and discharge; this model shows how the effect of discharge can be described by a “dilution rate” of the plankton growing in the river water.  相似文献   


8.
S. Krner  J. E. Vermaat 《Water research》1998,32(12):3651-3661
To arrive at detailed nutrient balances for duckweed-covered wastewater treatment systems, five laboratory-scale experiments were carried out in shallow (3.3 cm), 1 l batch systems to assess separately the contributions of duckweed itself, attached and suspended bacteria as well as algae to N- and P-removal in domestic wastewater. Depending on the initial concentrations, our duckweed-covered systems removed 120–590 mg N m−2 d−1 (73–97% of the initial Kjeldahl-nitrogen) and 14–74 mg P m−2 d−1 (63–99% of the initial total phosphorus) in 3 days. Duckweed (Lemna gibba L.) itself was directly responsible for 30–47% of the total N-loss by uptake of ammonium and, probably dependent on the initial P-concentrations, for up to 52% of the total P-loss. The indirect contribution of duckweed to the total nutrient removal was also considerable and included the uptake (and adsorption) of ammonium and ortho-phosphate by algae and bacteria in the attached biofilm and the removal of N through nitrification/denitrification by bacteria attached to the duckweed. Together these accounted for 35–46 and 31–71% of the total N- and P-loss, respectively. Therefore, approximately of the total N- and P-loss could be attributed to the duckweed mat. The remaining quarter is due to non-duckweed related components: uptake and nitrification/denitrification by algae and bacteria attached to the walls and the sediment of the system (including sedimentation). Other processes, like NH3-volatilisation, N-fixation and nutrient uptake as well as nitrification/denitrification by suspended microorganisms did not influence the N- and P-balance of our systems, but could become important with increasing water depths and retention times.  相似文献   

9.
More and more studies reported that there were insufficient ventilation and excessive CO_2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO_2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO_2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO_2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO_2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.  相似文献   

10.
In down-flow fluidization, particles with a specific density smaller than the liquid are fluidized downward by a concurrent flow of liquid. This paper describes the application of the down-flow (or inverse) fluidization technology for the anaerobic digestion of red wine distillery wastewater. The carrier employed was ground perlite, an expanded volcanic rock. Before starting-up the reactor, physical and fluidization properties of the carrier material were determined. 0.968 mm perlite particles were found to have a specific density of 280 kg m−3 and a minimum fluidization velocity of 2.3 m h−1. Once the down-flow anaerobic fluidized bed system reached the steady-state, organic load was increased stepwise by reducing HRT, from 3.3–1.3 days, while maintaining constant the feed TOC concentration. The system achieved 85% TOC removal, at an organic loading rate of 4.5 kg TOC m3 d−1. It was found that the main advantages of this system are: low energy requirement, because of the low fluidization velocities required; there is no need of a settling device, because solids accumulate at the bottom of the reactor so they can be easily drawn out, and particles with high-biomass content, whose specific density have become larger than 1000 kg m−3 can be easily recovered.  相似文献   

11.
A study was conducted into the ventilation effectiveness of a ventilation system within a public transport interchange (PTI) in Hong Kong. A computational fluid dynamics (CFD), steady state computational model of the PTI was used to investigate and predict the typical pollutant emission pattern for buses. In Hong Kong, the displacement ventilation (DV) scheme is often employed for the PTI. The numerical simulation investigates the effectiveness of the DV system in removing pollutants from the occupied zone. An alternative model is proposed where the supply is located at the ceiling and the exhausts are located at the lower part of the columns. It was found that both systems could adequately ventilate the PTI; however, the ceiling based air supply system is able to provide improved thermal comfort and indoor air quality (IAQ).  相似文献   

12.
《Energy and Buildings》2006,38(11):1302-1307
This paper reports on the results of a questionnaire survey on sleeping thermal environment and bedroom air conditioning in high-rise residential buildings in Hong Kong. The survey aimed at investigating the current situation of sleeping thermal environment and bedroom air conditioning, in order to gather relevant background information to develop strategies for bedroom air conditioning in the subtropics. It focused on the use patterns and types of bedroom air conditioning systems used, human factors such as the use of bedding and sleepwear during sleep, preference for indoor air temperature settings in bedrooms, ventilation control at nighttime with room air conditioner (RAC) turned on, etc. The results of the survey showed that most of the respondents would prefer a relatively low indoor air temperature at below 24 °C. Most of the respondents might however not be satisfied with the indoor air quality (IAQ) in bedrooms in Hong Kong. On the other hand, 68% of the respondents did not use any ventilation control intentionally during their sleep with their RACs turned on. A lack of knowledge of the ventilation control devices provided on window type room air conditioners (WRACs) indicated an urgent need for user education.  相似文献   

13.
The uncertainties of professional choice of ‘representative’ sampling locations for general indoor air quality (IAQ) assessment are reported from the perspective of probable errors deviated from the sample-spatial average pollutant concentration of an indoor environment. In this study, associations between the professional choices of the sampling locations and attributes of the assessors were examined to quantify the uncertainties of the IAQ assessment results for a typical air-conditioned office in Hong Kong. In particular, a long-term (one-year) measurement result of the spatial indoor carbon dioxide (CO2) concentrations in this office was used as a basis to investigate the probable errors due to the choices of sampling locations. Comparing with the random choices, the assessment accuracy with the expert choices would be significantly improved for coarse sampling point densities at certain engineering acceptable error limits. It was reported that the location choices and assessment accuracy would be significantly influenced by the academic background of the assessors. An assessor group with higher academic level would make a choice leaning towards more accurate assessment results. To avoid an inappropriate level of reliance on the assessment results, uncertainties must be quantified for IAQ assessment. This study provided a template for further investigations into the uncertainties of IAQ assessment results involving professional choice of ‘representative’ sampling locations and the results might be a useful reference for assessing indoor environment elsewhere.  相似文献   

14.
The thermal environment for air-conditioned offices in subtropical climates is examined from the prospect of maintaining an optimum operative temperature for the occupants. In this study, the optimum neutral temperature is evaluated from 422 occupants’ responses towards the perceiving thermal environment in 61 air-conditioned offices and 186 complaints of thermal discomfort in an air-conditioned office building on an electronic questionnaire, using a semantic differential evaluation scale and a dichotomous assessment scale. In particular, physical parameters for the thermal comfort study were measured by an indoor environmental quality (IEQ) logger, and the operative temperature was correlated with the occupants’ thermal responses. The probability of accepting an operative temperature for the thermal comfort of the occupants was correlated with logistic regression curves; the optimum operative temperature was derived in order to maximize the probability of thermal comfort expressed by the occupants. The results showed that the thermal neutral temperatures for air-conditioned offices in subtropical climates were 23.6 and 21.4 °C in summer and winter, respectively. The preferred thermal environment in Hong Kong should be slightly cool, corresponding to about 1 °C below the neutral temperature, in order to satisfy most of the occupants in the office space.  相似文献   

15.
Sekhar SC  Tham KW  Cheong KW 《Indoor air》2003,13(4):315-331
An integrated indoor air quality (IAQ)-energy audit methodology has been developed in this study in Singapore, which provides a rigorous and systematic method of obtaining the status-quo assessment of an 'IAQ signature' in a building. The methodology entails a multi-disciplinary model in obtaining measured data pertaining to different dimensions within the built environment such as the physical, chemical, biological, ventilation, and occupant response characteristics. This paper describes the audit methodology and presents the findings from five air-conditioned office buildings in Singapore. The research has also led to the development of an indoor pollutant standard index (IPSI), which is discussed in this paper. Other performance indicators such as, the ventilation index and the energy index as well as the building symptom index (BSI) are also presented and discussed in the context of an integrated approach to IAQ and energy. Several correlation attempts were made on the various symptoms, indoor air acceptability, thermal comfort, BSI and IPSI, and while BSI values are found to correlate among them as well as with IAQ and THERMAL COMFORT acceptability, no such correlation was observed between BSI and IPSI. This would suggest that the occupants' perception of symptoms experienced as well as environmental acceptability is quite distinct from IAQ acceptability determined from empirical measurements of indoor pollutants, which reinforces the complex nature of IAQ issues.  相似文献   

16.
Chan P 《Indoor air》1999,9(4):290-296
With the greater use of air-conditioned offices in Singapore, achieving good indoor air quality has become an important issue. The laws that impose duties upon designers and contractors with respect to the design and construction of air-conditioning and mechanical ventilation (ACMV) systems are set out in the Building Control Regulations and the Singapore Standard Code of Practice for Mechanical Ventilation and Air-conditioning in Buildings (hereinafter "SS CP 13:1980"). ACMV maintenance is governed by the Environmental Public Health Act, the Building and Common Property (Maintenance and Management) Act, and the Land Titles (Strata) Act, as well as by lease or tenancy agreements. Designers, contractors, developers, building owners and management corporations may also be liable to the workers, occupants and other premises users for indoor air quality (IAQ)-related injuries under the general principles of contract and tort. Recently, the Guidelines for Good Indoor Air Quality in Office Premises was issued by the Ministry of Environment to complement SS CP 13:1980 toward improving the indoor air quality of air-conditioned office premises. Although the Guidelines have no statutory effect, they may be adopted as contractual requirements in construction, lease and maintenance contracts. They may also be used to determine the relevant standard of duty of care required to discharge tortious liability. This paper looks at the existing laws and rules affecting the design, construction and maintenance of air-conditioned offices in light of Part III of the Ministry's Guidelines.  相似文献   

17.
Zuraimi MS  Tham KW  Chew FT  Ooi PL 《Indoor air》2007,17(4):317-327
This paper reports the effects of ventilation strategies on indoor air quality (IAQ) and respiratory health of children within 104 child care centers (CCCs) in a hot and humid climate. The CCCs were categorized by ventilation strategies: natural (NV), air-conditioned and mechanically ventilated (ACMV), air-conditioned using split units (AC), and hybrid (NV and AC operated intermittently). The concentration levels of IAQ parameters in NV CCCs are characterized by the influence of the outdoors and good dilution of indoor pollutants. The lower ventilation rates in air-conditioned CCCs result in higher concentrations of occupant-related pollutants but lower outdoor pollutant ingress. This study also revealed lower prevalence for most asthma and allergy, and respiratory symptoms in children attending NV CCCs. In multivariate analyses controlled for the effects of confounders, the risk of current rhinitis among children is significantly higher if they attend mechanically ventilated CCCs compared to NV CCCs. Air-conditioned CCCs were also associated with higher adjusted prevalence ratio of severe phlegm and cough symptoms and lower respiratory illness. Finally, children attending CCCs with hybrid ventilation are at high risk for almost all the respiratory symptoms studied. PRACTICAL IMPLICATIONS: This large field study indicates that different ventilation strategies employed by child care centers can cause significant variations in the indoor air quality and prevalence of asthma, allergies and respiratory symptoms of attending children. The higher prevalence rates of allergic and respiratory symptoms among young children, whose immune system is still under-developed, in child care centers, whether fully or partially air-conditioned, suggest that ventilation and plausible growth and propagation mechanisms of allergens and infectious agents be further investigated.  相似文献   

18.
《Energy and Buildings》1998,27(2):207-219
The Hong Kong Building Environmental Assessment Method (HK-BEAM), an environmental assessment method for air-conditioned office buildings, has been developed by the Real Estate Developers Association (REDA) for use in Hong Kong. Two versions of the scheme have been developed; one for new office premises and the other for existing office premises. HK-BEAM embraces a variety of issues related to the global, local and indoor environments. The efficient use of electricity forms a major part of the assessment. The basis for the energy performance assessment method, and the criteria for obtaining the relevant credits are described and discussed.  相似文献   

19.
Indoor air quality at nine shopping malls in Hong Kong.   总被引:5,自引:0,他引:5  
Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.  相似文献   

20.
Ventilation is important because it affects indoor environmental conditions, including air pollutant concentrations that may modify the health of the occupants of a building, or their perceptions and comfort. This paper reports, first of all, on field studies monitoring indoor overnight CO2 levels and outdoor ventilation rates in bedrooms employing room air conditioners (RACs), so the current situation of ventilation in actual high-rise residential buildings in Hong Kong can be appreciated. This is followed by a report of the results of laboratory experiments where two typical RACs were used in an examination of outdoor air ventilation characteristics in rooms employing RACs. The results of field studies showed that the outdoor ventilation rates in the measured bedrooms equipped with RACs in high-rise residential buildings in Hong Kong could not meet the ventilation requirement specified in the ASHRAE standard 62-2001 even if there was only one occupant in a bedroom. Although the use of a window-type air conditioner (WRAC) may provide a higher outdoor ventilation rate than the use of a split-type air conditioner (SARC), this may be ascribed to the fact there is more natural infiltration when a WRAC is used. The ventilation damper currently available in a WRAC does not significantly affect the outdoor ventilation rate. Therefore, such a damper cannot be expected to provide the ventilation rate as required by a ventilation code and its intended function of controlling ventilation is limited. In addition, the air exhausted from indoors to outdoors through the ventilation outlet in a WRAC is air that has just been cooled by the cooling coil (evaporator). This is unreasonable, because exhausting just-cooled and dehumidified air is a waste of energy. Therefore, an improved design for a WRAC has been suggested. Finally, the outdoor ventilation requirement for bedrooms at nighttime, when occupants are asleep, is discussed. A new ventilation rate of 3.0 l/s per person for the sleeping environment in high-rise residential buildings is proposed.  相似文献   