首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到12条相似文献,搜索用时 62 毫秒
1.
全桥单元作为子模块且主电路采用三角形连接的拓扑(single-delta bridge cells,SDBC)和半桥单元作为子模块且主电路采用双星形连接的拓扑(double-star chopper cells,DSCC)都可应用于负序电流的补偿,但两种拓扑负序电流补偿机理不同,哪种拓扑更具优势尚待研究。文中分别阐明了SDBC型静止无功发生器(static var generator,SVG)和双星形连接的拓扑(double-star chopper cells,DSCC)型SVG的负序补偿原理,对环流和桥臂电流进行了数学推导,并进行了仿真验证。对比分析了两种模块化多电平SVG的负序补偿特性,分析表明在相同的负序补偿情况下,DSCC型SVG的桥臂电流应力和安装容量均小于SDBC型SVG。所得结论为工程应用时合理选择负序补偿拓扑提供了理论依据。  相似文献   

2.
考虑负序补偿的角型链式SVG指令电流提取方法   总被引:1,自引:0,他引:1  
角型链式静止无功发生器(static var generator,SVG)理论上能够进行负序、无功和谐波电流的综合补偿。针对角型补偿器指令电流提取的难题,通过对补偿电路相量图进行几何分析,根据瞬时无功功率理论,推导出dq/Δ变换矩阵。三相电流瞬时值经 abc/dq 变换、滤波,得到两相旋转坐标系下的负序有功电流分量和负序无功电流分量;再经 dq/Δ变换矩阵,可得到角型链式SVG负序补偿所需的相电流指令信号。该变换矩阵可应用于负序补偿系统,也可应用于负序、无功和谐波电流综合补偿系统。所提指令电流提取方法物理意义清晰,算法简单;采用电流瞬时值进行运算,负荷变化时,可实时更新指令电流,动态调节速度快。最后,通过PSIM仿真验证了所提方法的正确性。  相似文献   

3.
基于同步旋转变换及DFT的SVG指令电流检测法   总被引:1,自引:0,他引:1       下载免费PDF全文
为使静止无功发生器(Static Var Generator,SVG)具备无功、谐波及不对称电流综合补偿能力,提出了一种基于同步旋转坐标变换及离散傅立叶变换(Discrete Fourier Transform,DFT)的SVG指令电流检测方法。该方法通过在同步旋转坐标系下进行递归离散傅立叶变换,能够实时检测出负载电流中的无功分量、不对称分量以及特征谐波。利用该方法只用一个控制器就能同时对两种特征谐波分量进行补偿,相对于其他方法运算量大大减小,便于工程实现。仿真和实验验证证明了该方法的有效性。  相似文献   

4.
级联固态变压器可以直接接入高压配电网,但其存在的直流电压不平衡和功率不均衡问题,将严重影响装置可靠运行。针对三角形级联固态变压器提出了一种多直流电压平衡控制方法,并在建立装置的平均功率模型的基础上,对比分析了其在不同控制方法下的相内和相间功率特性。所提出的方法在满足直流电压平衡和功率均衡调节的同时消除了传统方法中直流变换环节的电流传感器。通过仿真和实验对所提方法的有效性进行了验证,结果表明该方法大幅简化了控制系统,并给装置带来了更好的不平衡无功补偿能力。  相似文献   

5.
新能源技术的发展要求电力电子设备不断提高功率,促使了电力电子设备并联系统的产生。文中通过分析多个变流器并联系统的平均值模型,对多变流器并联系统的零序电流产生的原因进行了简单的分析,给出了两种可行的零序环流抑制方法。为了进一步分析两种方法的效果,文中建立了SIMULINK仿真模型。仿真结果表明,PI控制和无差拍控制均可对零序环流有较好的抑制作用。但是PI控制的抑制效果更加稳定,更加适合实际应用。  相似文献   

6.
针对传统星接链式STATCOM较难实现不平衡补偿的问题,提出了一种星接链式STATCOM实现不平衡补偿功能的新拓扑结构,即增加一台接地变压器,将STATCOM和接地变压器的中点相连,实现负序补偿所需的零序电流通路。通过功率分析,分析了这种新拓扑结构下参考电流和零序电流生成方法,并推导了该结构下相间直流电压平衡的控制方法。仿真波形和整机实验数据表明,采用所提结构和控制方法后,负荷中的负序电流得到了较好的补偿,相间直流电压平衡的效果较好。工程分析表明,所提方法与增加△/Y连接变压器实现不平衡补偿的方式相比,在成本和占地上都有较大优势。  相似文献   

7.

Object

Eddy current compensation by dynamic reference phase modulation (eDREAM) is a compensation method for eddy current fields induced by B 0 field-cycling which occur in delta relaxation enhanced MR (dreMR) imaging. The presented method is based on a dynamic frequency adjustment and prevents eddy current related artifacts. It is easy to implement and can be completely realized in software for any imaging sequence.

Materials and methods

In this paper, the theory of eDREAM is derived and two applications are demonstrated. The theory describes how to model the behavior of the eddy currents and how to implement the compensation. Phantom and in vivo measurements are carried out and demonstrate the benefits of eDREAM.

Results

A comparison of images acquired with and without eDREAM shows a significant improvement in dreMR image quality. Images without eDREAM suffer from severe artifacts and do not allow proper interpretation while images with eDREAM are artifact free. In vivo experiments demonstrate that dreMR imaging without eDREAM is not feasible as artifacts completely change the image contrast.

Conclusion

eDREAM is a flexible eddy current compensation for dreMR. It is capable of completely removing the influence of eddy currents such that the dreMR images do not suffer from artifacts.  相似文献   

8.
330 kV及以上超高压大容量自耦变压器常配有零序电流差动保护,以提高接地故障时保护动作的灵敏性.对一座330 kV变电站的360 MVA自耦变压器在空载投运时和用中压侧开关向110 kV母线充电时,微机保护记录的采样值及波形数据进行分析,阐明了零序电流差动保护用工作电压和负荷电流检验其电流二次接线正确性的方法.该变压器保护投运至今已经受了多次区外故障的考验,该方法具有一定的工程实用价值.  相似文献   

9.
以常见的WXH-11X型微机保护装置为例,讨论了电力系统常见的单相接地故障的零序电流、零序电压极性问题以及回路接线方法,介绍了借助于微机保护装置判定电源与负荷相序的方法和通过测定有效值来判定常见接地故障形式的手段.  相似文献   

10.
自耦变压器零差保护二次接线正确性判断   总被引:1,自引:0,他引:1       下载免费PDF全文
330 kV及以上超高压大容量自耦变压器常配有零序电流差动保护,以提高接地故障时保护动作的灵敏性。对一座330 kV变电站的360 MVA自耦变压器在空载投运时和用中压侧开关向110 kV母线充电时,微机保护记录的采样值及波形数据进行分析,阐明了零序电流差动保护用工作电压和负荷电流检验其电流二次接线正确性的方法。该变压器保护投运至今已经受了多次区外故障的考验,该方法具有一定的工程实用价值。  相似文献   

11.
通过对接地故障零序电流分布的分析,讨论了特殊电网方式下输电线零序反时限电流保护不能保证选择性的问题.即在某些情况下,相邻线路中的零序电流不一定小于故障线中的零序电流.从而可能造成相邻线路反时限零序保护的误动,即使考虑相继动作也不能保证其选择性.作为零序保护简化的一种选择,宜在反时限特性中增加一段附加延时,将反时限零序保护作为接地距离保护的补充,用以反应高阻接地故障.  相似文献   

12.
针对灵活接地系统高阻接地故障选线困难的问题,提出一种基于零序电流幅值比倍增系数的灵活接地系统故障选线方法。首先,分析了系统单相接地故障时并联小电阻投入前后中性点与线路零序电流幅值比的变化特征,即:中性点与健全线路零序电流幅值比增大,而中性点与故障线路零序电流幅值比减小。其次,通过引进倍增系数定量刻画幅值比变化趋势,继而构造故障选线自适应判据。此外,利用中性点电感和电阻间接求解小电阻投入后零序电流幅值微弱的健全线路倍增系数,有效降低因零序CT精度限制所导致的选线误判概率。理论分析和仿真结果表明,该方法耐过渡电阻能力可达3000?,无需零序电压信息,可靠且适用性强。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号