首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We studied two children born to a myasthenic mother. The first child, a female, had multiple flexion contractures. She died 1 h after birth. In the second pregnancy, 3 years later, ultra-sonographic examination at 20 weeks showed decreased fetal movements and multiple flexion contractures. The pregnancy was interrupted. Eight other cases of congenital rnyasthenia with arthrogryposis are known; four of them are siblings. The recurrence risk may be as high as 100 per cent. Our second case demonstrates that prenatal diagnosis is possible early enough to allow termination of pregnancy.  相似文献   

3.
A case of fetal pleural effusion in a fetus affected with Duchenne muscular dystrophy (DMD) is reported. This case is discussed in the context of the previous observation of frequent stillbirths among male fetuses in DMD families.  相似文献   

4.
Two fetuses with extreme growth retardation (IUGR) of 31 and 34 weeks gestation were studied using a combination of two dimensional echocardiography (2DE), pulse wave Doppler (PWD) and differential measurement of the instantaneous vessel diameter techniques. The first fetus was diagnosed as having univentricular heart or possible double outlet right ventricle (DORV). Descending aorta blood flow was reduced as was indexing for weight. The second fetus was diagnosed as having univentricular heart with periodic bigeminal and trigeminal rhythm. Descending aorta blood flow was measured on two occasions and was reduced both times. Indexing for weight was within normal limits the first time and showed gross reduction on the second occasion prior to fetal demise. Fetal death occurred in both cases at 34 weeks gestation. Cardiovascular evaluation in fetuses with IUGR is useful as the detection of severe congenital cardiac abnormalities may substantially alter the management of these pregnancies, in particular caesarean section may be avoided when the prognosis for the fetus is considered hopeless.  相似文献   

5.
6.
We report the first positive prenatal diagnosis ofcongenital non-bullous ichthyosiform erythroderma or lamellar ichthyosis. Fetal skin samples were obtained by fetoscopy at 21 weeks' gestation and examined by light and electron microscopy. Light microscopy revealed a thickened interfollicular epidermis with multiple layers of flattened cells and excessive keratinization of the epidermal lining of the follicular infundibulum. Electron microscopy of the thickened epidermis revealed granular cells that contained larger-than-normal keratohyalin granules and multiple layers of parakeratotic cornified cells. Although there was regional variation in the degree of interfollicular keratinization, follicles from all regions showed greater and more complete keratinization, indicating that they express the abnormality early enough in development to permit prenatal diagnosis at about 20 weeks' gestation.  相似文献   

7.
The close genetic linkage between HLA-B and congenital adrenal hyperplasia due to 21-hydroxylase deficiency permits prenatal diagnosis of an affected fetus by HLA typing of amniotic fluid cells in pregnancies at risk. Some families at risk, especially those with an affected girl with ambiguous genitalia, will only plan another pregnancy if a prenatal diagnosis is possible. After HLA typing of the index case, parents and eventually grandparents, the family were informed of the possibility of a prenatal diagnosis. Fibroblast cell lines were initiated from skin biopsies of the index cases and parents and were used as controls in the tests. HLA typing of the fetus was done on amniotic fluid cells grown in vitro using first, a microcytotoxicity test and second quantitative microabsorption test. Ten prenatal diagnoses are reported. In two cases the HLA genotype indicated an affected fetus, examination of the aborted fetuses was in agreement with the diagnosis. In one case an affected male fetus was diagnosed, the pregnancy is in progress. In seven cases an unaffected infant was predicted (four carriers and three homozygous normal infants).  相似文献   

8.
Prenatal diagnosis of congenital enzymopenic methaemoglobinaemia (CEM) with mental retardation was performed in two fetuses at risk for generalized NADH-cytochrome b5 reductase deficiency. In the first case the enzyme activity of cultured amniotic cells was in the heterozygous to normal range. The mother delivered a normal baby with normal enzyme activity in cord blood cells. In the second case, the amniotic cells were almost completely enzyme deficient. The pregnancy was terminated, and the diagnosis of homozygous NADH-cytochrome b5 reductase deficiency was confirmed in cord blood cells, in several different tissues and in cultured fibroblasts from the aborted fetus.  相似文献   

9.
The prenatal diagnosis by ultrasound of congenital chylothorax is described allowing early intervention immediately after delivery. Unilateral fluid collection in the right lung with marked displacement of the heart to the left were the most prominent sonographic signs. Post partum thoracocentesis and chylus fluid drainage served as a life saving procedure.  相似文献   

10.
In 3 fetuses affected by congenital chloride diarrhoea there were characteristic prenatal ultrasonic findings. In all cases the fetal abdominal cavity was filled with distended loops of fetal intestine, the fetal stomach was of normal size and polyhydramnios was present. The prenatal ultrasonic findings in this metabolic inherited disease are identical to those caused by mechanical obstruction of the distal fetal intestine. Whenever these findings are encountered prenatally, the possibility of chloride diarrhoea should be considered, because therapy with electrolytes is needed rather than the surgical intervention required in mechanical intestinal obstruction.  相似文献   

11.
Fifteen fetuses at risk of congenital human cytomegalovirus (HCMV) infection underwent prenatal diagnosis at 16–30 weeks' gestation by a combination of amniocentesis and fetal blood sampling. HCMV was isolated from the amniotic fluid in six patients, but HCMV-specific IgM was detected in only three of them. Two of the nine neonates, who were delivered following a negative prenatal diagnosis, had congenital HCMV infection diagnosed by virus isolation in the urine. The interval from infection to prenatal testing was 3 and 4 weeks in the two false-negative cases and ⩾ 7 weeks in the true-positive cases. Although timely testing for HCMV infection allows the option of termination of pregnancy, it may be flawed by false-negative results.  相似文献   

12.
13.
The concentration of 17OH-progesterone was measured in second trimester amniotic fluid samples from 12 mothers who previously had had an infant with congenital adrenal hyper-plasia due to 21-hydroxylase deficiency. In 4 affected pregnancies, the concentrations were more than 2 S.D. higher than those determined in 44 samples from normal pregnancies (mean ± S.D., 8·1 ± 2·4 nmol/1). The remaining 8 pregnancies were predicted to be unaffected based on the results of amniotic fluid concentrations within the normal range. In each instance, the infant was normal. The results indicate that measurement of amniotic fluid 17OH-progester-one concentrations during the second trimester is an accurate prenatal test for 21-hydroxylase deficiency. The results should be supplemented with determination of fetal sex by karyotype analysis on the amniotic fluid cells.  相似文献   

14.
Fetal pleural effusion, a nonspecific accumulation of fluid in the pleural space, is an uncommon anomaly which can be associated with aneuploidy and a range of other structural malformations or genetic syndromes. Spontaneous resolution is not rare and confers a good prognosis. Perinatal outcome is better for those fetuses without hydrops than those presenting with hydrops. A detailed review of the literature indicates that, for fetuses with persistent effusions, in utero intervention (repeated thoracocentesis, intrauterine shunting and pleurodesis) may improve the chances of survival. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

15.
16.
Congenital hypophosphatasia is an autosomal recessive disorder, which usually has a fatal outcome during the neonatal period. This report presents the prenatal diagnosis of hypophosphatasia at 16 weeks of gestation. The characteristic ultrasonic findings in this abnormality demonstrate the superiority of ultrasound as compared with radiography.  相似文献   

17.
Fluid from pleural effusion (n=2) and cystic hygroma (n=7) was obtained from eight fetuses, between 13 and 32 weeks of pregnancy at the time when a conventional prenatal diagnosis procedure was carried out. As these fluids contain lymphocytes, they were processed like peripheral blood. A karyotype was obtained in 4 days in both cases of pleural effusion and in four out of seven samples of cystic hygroma. An abnormal karyotype was detected in three of the four samples of cystic hygroma: two trisomies 21 and a monosomy X. Different parameters were evaluated in order to predict the feasibility of obtaining a cytogenetic diagnosis. Our data showed that if the amount of fluid obtained was ⩾4 ml and the initial lymphocyte count (ILC) was >0.2 × 106 cells/ml, a cytogenetic diagnosis was possible from an initial concentration of cultured lymphocytes )ICCL) of >0.06 × 106 cells/ml.  相似文献   

18.
Prenatal diagnosis performed by fetal ultrasound scan is now a routine part of antenatal care in many countries. That an increasing number of fetal anomalies may be detected on prenatal ultrasound is beyond doubt. What is possible is not, however, always practical, especially when congenital heart diseases (CHDs) are concerned and when whole antenatal populations are screened rather than high-risk groups. Thanks to our registry of congenital anomalies, a retrospective study was undertaken to evaluate the prenatal detection of CHDs by ultrasound scan in 131 760 consecutive pregnancies of known outcome from 1979 to 1988. Only 84 out of 912 malformed fetuses with CHDs without chromosomal anomalies were detected (9.2 per cent). The sensitivity of detection varied from around 38 per cent for malformations such as hypoplastic left heart and single ventricle to around 5 per cent for ventricular and atrial septal defects. The effectiveness of the detection of some forms of major congenital heart disease has increased dramatically since 1987 by including routine examination of the four-chamber view and of the inflow and outflow tracts of the fetal heart. Our results stress the need to obtain a definite clear four-chamber view, to perform scans at ⩾ 18 weeks of gestation, and to train sonographers in order to improve the prenatal detection of CHDs.  相似文献   

19.
We report on a new case of ultrasonographic prenatal diagnosis of Fryns' syndrome during the second pregnancy of a young woman whose first child died 90 min after birth and was diagnosed as having this autosomal recessive condition. The feasibility of diagnosis in utero and timing in the phenotypic expression of this multimalformation syndrome are discussed.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号