首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Several non‐invasive Raman spectroscopy‐based assays have been reported for rapid and sensitive detection of pathogens. We developed a novel statistical model for the detection of RNA viruses in saliva, based on an unbiased selection of a set of 65 Raman spectral features that mostly attribute to the RNA moieties, with a prediction accuracy of 91.6% (92.5% sensitivity and 88.8% specificity). Furthermore, to minimize variability and automate the downstream analysis of the Raman spectra, we developed a GUI‐based analytical tool “RNA Virus Detector (RVD).” This conceptual framework to detect RNA viruses in saliva could form the basis for field application of Raman Spectroscopy in managing viral outbreaks, such as the ongoing COVID‐19 pandemic. ( http://www.actrec.gov.in/pi-webpages/AmitDutt/RVD/RVD.html ).  相似文献   

2.
Surface-enhanced Raman scattering (SERS) is highly sensitive and label-free analytical technique based on Raman spectroscopy aided by field-multiplying plasmonic nanostructures. We report the use of SERS measurements of patient urine in conjunction with biostatistical algorithms to assess the treatment response of prostate cancer (PCa) in 12 recurrent (Re) and 63 nonrecurrent (NRe) patient cohorts. Multiple Raman spectra are collected from each urine sample using monodisperse silver nanoparticles (AgNPs) for Raman signal enhancement. Genetic algorithms-partial least squares-linear discriminant analysis (GA-PLS-LDA) was employed to analyze the Raman spectra. Comprehensive GA-PLS-LDA analyses of these Raman spectral features (p = 3.50 × 10−16 ) yield an accuracy of 86.6%, sensitivity of 86.0%, and specificity 87.1% in differentiating the Re and NRe cohorts. Our study suggests that SERS combined with multivariate GA-PLS-LDA algorithm can potentially be used to detect and monitor the risk of PCa relapse and to aid with decision-making for optimal intermediate secondary therapy to recurred patients.  相似文献   

3.
Monte Carlo (MC) modeling is a valuable tool to gain fundamental understanding of light-tissue interactions, provide guidance and assessment to optical instrument designs, and help analyze experimental data. It has been a major challenge to efficiently extend MC towards modeling of bulk-tissue Raman spectroscopy (RS) due to the wide spectral range, relatively sharp spectral features, and presence of background autofluorescence. Here, we report a computationally efficient MC approach for RS by adapting the massively-parallel Monte Carlo eXtreme (MCX) simulator. Simulation efficiency is achieved through “isoweight,” a novel approach that combines the statistical generation of Raman scattered and Fluorescence emission with a lookup-table-based technique well-suited for parallelization. The MC model uses a graphics processor to produce dense Raman and fluorescence spectra over a range of 800 − 2000 cm−1 with an approximately 100× increase in speed over prior RS Monte Carlo methods. The simulated RS signals are compared against experimentally collected spectra from gelatin phantoms, showing a strong correlation.  相似文献   

4.
Malignant melanoma is an aggressive form of skin cancer, which develops from the genetic mutations of melanocytes – the most frequent involving BRAF and NRAS genes. The choice and the effectiveness of the therapeutic approach depend on tumour mutation; therefore, its assessment is of paramount importance. Current methods for mutation analysis are destructive and take a long time; instead, Raman spectroscopy could provide a fast, label-free and non-destructive alternative. In this study, confocal Raman microscopy has been used for examining three in vitro melanoma cell lines, harbouring different molecular profiles and, in particular, specific BRAF and NRAS driver mutations. The molecular information obtained from Raman spectra has served for developing two alternative classification algorithms based on linear discriminant analysis and artificial neural network. Both methods provide high accuracy (≥90%) in discriminating all cell types, suggesting that Raman spectroscopy may be an effective tool for detecting molecular differences between melanoma mutations.  相似文献   

5.
We herein report a novel, reliable and inexpensive method for detecting esophageal cancer using blood plasma resonance Raman spectroscopy combined with multivariate analysis methods. The blood plasma samples were divided into late stage cancer group (n = 164), early stage cancer group (n = 35) and normal group (n = 135) based on clinical pathological diagnosis. Using a specially designed quartz capillary tube as sample holder, we obtained higher quality resonance Raman spectra of blood plasma than existing method. The study demonstrated that the carotenoids levels in blood plasma were reduced in esophageal cancer patients. The area under the receiver operating characteristic curve (and 95% confidence interval) calculated by wavenumber selection and principal component analysis combined with linear discriminant analysis (PC-LDA) algorithm were 0.894 (0.858-0.929), 0.901 (0.841-0.960) and 0.871 (0.799-0.942) for differentiating late cancer from normal, late cancer from early cancer, and early cancer from normal respectively. The contribution from the two carotenoids wavenumber regions of 1155 and 1515 cm−1 were more than 84.2%. The results show that the plasma carotenoids could be a potential biomarker for screening esophageal cancer using resonance Raman spectroscopy combined with wavenumber selection and PC-LDA algorithms.   相似文献   

6.
Rapid and early identification of pathogens is critical to guide antibiotic therapy. Raman spectroscopy as a noninvasive diagnostic technique provides rapid and accurate detection of pathogens. Raman spectrum of single cells serves as the “fingerprint” of the cell, revealing its metabolic characteristics. Rapid identification of pathogens can be achieved by combining Raman spectroscopy and deep learning. Traditional classification techniques frequently require lots of data for training, which is time costing to collect Raman spectra. For trace samples and strains that are difficult to culture, it is difficult to provide an accurate classification model. In order to reduce the number of samples collected and improve the accuracy of the classification model, a new pathogen detection method integrating Raman spectroscopy, variational auto-encoder (VAE), and long short-term memory network (LSTM) is proposed in this paper. We collect the Raman signals of pathogens and input them to VAE for training. VAE will generate a large number of Raman spectral data that cannot be distinguished from the real spectrum, and the signal-to-noise ratio is higher than that of the real spectrum. These spectra are input into the LSTM together with the real spectrum for training, and a good classification model is obtained. The results of the experiments reveal that this method not only improves the average accuracy of pathogen classification to 96.9% but also reduces the number of Raman spectra collected from 1000 to 200. With this technology, the number of Raman spectra collected can be greatly reduced, so that strains that are difficult to culture or trace can be rapidly identified.  相似文献   

7.
We demonstrate a novel bio‐spectroscopic technique, “simultaneous Raman/GFP microspectroscopy”. It enables organelle specific Raman microspectroscopy of living cells. Fission yeast, Schizosaccharomyces pombe, whose mitochondria are green fluorescence protein (GFP) labeled, is used as a test model system. Raman excitation laser and GFP excitation light irradiate the sample yeast cells simultaneously. GFP signal is monitored in the anti‐Stokes region where interference from Raman scattering is negligibly small. Of note, 13 568 Raman spectra measured from different points of 19 living yeast cells are categorized according to their GFP fluorescence intensities, with the use of a two‐component multivariate curve resolution with alternate least squares (MCR‐ALS) analysis in the anti‐Stokes region. This categorization allows us to know whether or not Raman spectra are taken from mitochondria. Raman spectra specific to mitochondria are obtained by an MCR‐ALS analysis in the Stokes region of 1389 strongly GFP positive spectra. Two mitochondria specific Raman spectra have been obtained. The first one is dominated by protein Raman bands and the second by lipid Raman bands, being consistent with the known molecular composition of mitochondria. In addition, the second spectrum shows a strong band of ergosterol at 1602 cm?1, previously reported as “Raman spectroscopic signature of life of yeast.”  相似文献   

8.
Hemolysis is a very common phenomenon and is referred as the release of intracellular components from red blood cells to the extracellular fluid. Hemolyzed samples are often rejected in clinics due to the interference of hemoglobin and intracellular components in laboratory measurements. Plasma and serum based vibrational spectroscopy studies are extensively applied to generate spectral biomarkers for various diseases. However, no studies have reported the effect of hemolysis in blood based vibrational spectroscopy studies. This study was undertaken to evaluate the effect of hemolysis on infrared and Raman spectra of blood plasma. In this study, prostate cancer plasma samples (n = 30) were divided into three groups (nonhemolyzed, mildly hemolyzed, and moderately hemolyzed) based on the degree of hemolysis and FTIR and Raman spectra were recorded using high throughput (HT)‐FTIR and HT‐Raman spectroscopy. Discrimination was observed between the infrared and Raman spectra of nonhemolyzed and hemolyzed plasma samples using principal component analysis. A classical least square fitting analysis showed differences in the weighting of pure components in nonhemolyzed and hemolyzed plasma samples. Therefore, it is worth to consider the changes in spectral features due to hemolysis when comparing the results within and between experiments.  相似文献   

9.
The key moment for efficiently and accurately diagnosing dementia occurs during the early stages. This is particularly true for Alzheimer's disease (AD). In this proof‐of‐concept study, we applied near infrared (NIR) Raman microspectroscopy of blood serum together with advanced multivariate statistics for the selective identification of AD. We analyzed data from 20 AD patients, 18 patients with other neurodegenerative dementias (OD) and 10 healthy control (HC) subjects. NIR Raman microspectroscopy differentiated patients with more than 95% sensitivity and specificity. We demonstrated the high discriminative power of artificial neural network (ANN) classification models, thus revealing the high potential of this developed methodology for the differential diagnosis of AD. Raman spectroscopic, blood‐based tests may aid clinical assessments for the effective and accurate differential diagnosis of AD, decrease the labor, time and cost of diagnosis, and be useful for screening patient populations for AD development and progression.

Multivariate data analysis of blood serum Raman spectra allows for the differentiation between patients with Alzheimer's disease, other types of dementia and healthy individuals.  相似文献   


10.
The object of this paper is in vivo study of skin spectral-characteristics in patients with kidney failure by conventional Raman spectroscopy in near infrared region. The experimental dataset was subjected to discriminant analysis with the projection on latent structures (PLS-DA). Application of Raman spectroscopy to investigate the forearm skin in 85 adult patients with kidney failure (90 spectra) and 40 healthy adult volunteers (80 spectra) has yielded the accuracy of 0.96, sensitivity of 0.94 and specificity of 0.99 in terms of identifying the target subjects with kidney failure. The autofluorescence analysis in the near infrared region identified the patients with kidney failure among healthy volunteers of the same age group with specificity, sensitivity, and accuracy of 0.91, 0.84, and 0.88, respectively. When classifying subjects by the presence of kidney failure using the PLS-DA method, the most informative Raman spectral bands are 1315 to 1330, 1450 to 1460, 1700 to 1800 cm−1. In general, the performed study demonstrates that for in vivo skin analysis, the conventional Raman spectroscopy can provide the basis for cost-effective and accurate detection of kidney failure and associated metabolic changes in the skin.  相似文献   

11.
Identifying persistent or relapsing disease in anti-neutrophil cytoplasmic autoantibody- associated vasculitis (AAV) remains a clinical challenge with an unmet need for a reliable biomarker of multisystem disease. In this study, we confirm for the first time that Raman spectroscopy offers a novel cost-effective candidate biomarker to discriminate active disease from remission in AAV with excellent accuracy. Spectrochemical interrogation of plasma and serum samples demonstrated equal ability to discriminate disease activity with good group separation on PC1 direction and a high degree of accuracy on validation testing using blind predictive modelling: F-score 80% for plasma (specificity 93.3%, sensitivity 70%, AUC 0.95) and 80% for serum (specificity 80%, sensitivity 80%, AUC 0.92). Similar findings were seen on analysis of paired remission samples following successful remission-induction therapy. A larger study with longitudinal data is required to validate these findings with the potential to aid patient care.  相似文献   

12.
Stimulated Raman scattering (SRS) microscopy is a label‐free method generating images based on chemical contrast within samples, and has already shown its great potential for high‐sensitivity and fast imaging of biological specimens. The capability of SRS to collect molecular vibrational signatures in bio‐samples, coupled with the availability of powerful statistical analysis methods, allows quantitative chemical imaging of live cells with sub‐cellular resolution. This application has substantially driven the development of new SRS microscopy platforms. Indeed, in recent years, there has been a constant effort on devising configurations able to rapidly collect Raman spectra from samples over a wide vibrational spectral range, as needed for quantitative analysis by using chemometric methods. In this paper, an SRS microscope which exploits spectral shaping by a narrowband and rapidly tunable acousto‐optical tunable filter (AOTF) is presented. This microscope enables spectral scanning from the Raman fingerprint region to the Carbon‐Hydrogen (CH)‐stretch region without any modification of the optical setup. Moreover, it features also a high enough spectral resolution to allow resolving Raman peaks in the crowded fingerprint region. Finally, application of the developed SRS microscope to broadband hyperspectral imaging of biological samples over a large spectral range from 800 to 3600 cm?1, is demonstrated.  相似文献   

13.
Infrared spectra obtained from cell or tissue specimen have commonly been observed to involve a significant degree of scattering effects, often Mie scattering, which probably overshadows biochemically relevant spectral information by a nonlinear, nonadditive spectral component in Fourier transform infrared (FTIR) spectroscopic measurements. Correspondingly, many successful machine learning approaches for FTIR spectra have relied on preprocessing procedures that computationally remove the scattering components from an infrared spectrum. We propose an approach to approximate this complex preprocessing function using deep neural networks. As we demonstrate, the resulting model is not just several orders of magnitudes faster, which is important for real-time clinical applications, but also generalizes strongly across different tissue types. Using Bayesian machine learning approaches, our approach unveils model uncertainty that coincides with a band shift in the amide I region that occurs when scattering is removed computationally based on an established physical model. Furthermore, our proposed method overcomes the trade-off between computation time and the corrected spectrum being biased towards an artificial reference spectrum.  相似文献   

14.
The main components of the stratum corneum (SC), water, lipids, and proteins, are non-homogeneously distributed throughout the depth. The quantitative determination of their concentration profiles and penetration depth of topically applied substances are urgent topics of dermatological and cosmetic research. Confocal Raman micro-spectroscopy has distinct advantages when determining semi-quantitative concentrations of SC components and topically applied substances non-invasively and in vivo. In this work, we applied a tailored multivariate curve resolution-alternating least squares (tMCR-ALS) method to analyze Raman spectra of the SC in the 2000–4000 cm−1 region for quantitatively determining the concentrations of water, lipids, proteins, and topically applied oils using substance-related spectral loadings which were allowed to change depth-dependently from the SC's surface toward its bottom. tMCR-ALS makes matching of depth-dependent signal attenuation, that is, the normalization on keratin, unnecessary and requires only a few additional experiments for calibration – Raman spectra of the pure materials and their densities.  相似文献   

15.
A Raman‐based, strain‐independent, semi‐automated method is presented that allows the rapid (<3 hours) determination of antibiotic susceptibility of bacterial pathogens isolated from clinical samples. Applying a priori knowledge about the mode of action of the respective antibiotic, we identified characteristic Raman marker bands in the spectrum and calculated batch‐wise weighted sum scores from standardized Raman intensity differences between spectra of antibiotic exposed and nonexposed samples of the same strains. The lead substances for three relevant antibiotic classes (fluoroquinolone ciprofloxacin, third‐generation cephalosporin cefotaxime, ureidopenicillin piperacillin) against multidrug‐resistant Gram‐negative bacteria (MRGN) revealed a high sensitivity and specificity for the susceptibility testing of two Escherichia coli laboratory strains and 12 clinical isolates. The method benefits from the parallel incubation of control and treated samples, which reduces the variance due to alterations in cultivation conditions and the standardization of differences between batches leading to long‐term comparability of Raman measurements.  相似文献   

16.
Using the shifted-excitation Raman difference spectroscopy technique and an optical fibre featuring a negative curvature excitation core and a coaxial ring of high numerical aperture collection cores, we have developed a portable, background and fluorescence free, endoscopic Raman probe. The probe consists of a single fibre with a diameter of less than 0.25 mm packaged in a sub-millimetre tubing, making it compatible with standard bronchoscopes. The Raman excitation light in the fibre is guided in air and therefore interacts little with silica, enabling an almost background free transmission of the excitation light. In addition, we used the shifted-excitation Raman difference spectroscopy technique and a tunable 785 nm laser to separate the fluorescence and the Raman spectrum from highly fluorescent samples, demonstrating the suitability of the probe for biomedical applications. Using this probe we also acquired fluorescence free human lung tissue data.  相似文献   

17.
18.
Crohn's disease (CD) and spondyloarthritis (SpA) are two inflammatory diseases sharing many common features (genetic polymorphism, armamentarium). Both diseases lack diagnostic markers of certainty. While the diagnosis of CD is made by a combination of clinical, and biological criteria, the diagnosis of SpA may take several years to be confirmed. Based on the hypothesis that CD and SpA alter the biochemical profile of plasma, the objective of this study was to evaluate the analytical capability of Fourier transform infrared spectroscopy (FTIR) in identifying spectral biomarkers. Plasma from 104 patients was analyzed. After data processing of the spectra by Extended Multiplicative Signal Correction and linear discriminant analysis, we demonstrated that it was possible to distinguish CD and SpA from controls with an accuracy of 97% and 85% respectively. Spectral differences were mainly associated with proteins and lipids. This study showed that FTIR analysis is efficient to identify plasma biosignatures specific to CD or SpA.  相似文献   

19.
The helical nature of human sweat ducts, combined with the morphological and dielectric properties of skin, suggests electromagnetic activity in the sub-THz frequency band. A detailed electromagnetic simulation model of the skin, with embedded sweat ducts, was created. The model includes realistic dielectric properties based on the measured water content of each layer of skin, derived from Raman Spectroscopy. The model was verified by comparing it to measurements of the reflection coefficient of the palms of 13 volunteers in the frequency band 350–410 GHz. They were subjected to a measurement protocol intended to induce mental stress, thereby also activating the sweat glands. The Galvanic Skin Response was concurrently measured. Using the simulation model the optimal ac-conductivity for each measurement was found. The range of variation for all subjects was found to be from 100 S/m to a maximum value of 6000 S/m with averages of 1000 S/m. These are one order of magnitude increase from the accepted values for water at these frequencies (~100 s/m at 100 GHz). Considering the known biochemical mechanism for inducing perspiration, we conclude that these ac-conductivity levels are probably valid, even though the real time measurements of sweat ac-conductivity levels inside the duct are inaccessible.  相似文献   

20.
Articular cartilage posesses unique material properties due to a complex depth-dependent composition of sub-components. Raman spectroscopy has proven valuable in quantifying this composition through cartilage cross-sections. However, cross-sectioning requires tissue destruction and is not practical in situ. In this work, Raman spectroscopy-based multivariate curve resolution (MCR) was employed in porcine cartilage samples (n = 12) to measure collagen, glycosaminoglycan, and water distributions through the surface for the first time; these were compared against cross-section standards. Through the surface Raman measurements proved reliable in predicting composition distribution up to a depth of approximately 0.5 mm. A fructose-based optical clearing agent (OCA) was also used in an attempt to further improve depth of resolution of this measurement method. However, it did not; mainly due to a high-spectral overlap with the Raman spectra of main cartilage sub-components. This measurement technique potentially could be used in situ, to better understand the etiology of joint diseases such as osteoarthritis (OA).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号